Products Products marked Relay for control panel of 1 A to 10 A (1c/2c/3c/4c) Standard type Amber sealed type HC RELAYS FEATURES TYPICAL APPLICATIONS 1. Standard type, Amber sealed type and Keep type 2. Rich lineup includes relays with operating indication, with diode and with CR circuit 3. Full range of types Plug-in type, PC board type and TM type 4. Sockets and terminal sockets are available. 1. Factory automation equipment and automotive devices 2. Control panels, power supply equipment, molding equipment, machine tools, welding equipment, agricultural equipment, etc. 3. Office equipment, automatic vending machines, telecommunications equipment, disaster prevention equipment, copiers, measuring devices, medical equipment, amusement devices, etc. 4. All types of household appliance With CR circuit type Keep relay HC are discontinued as of August 31, 2012 With diode type Product to be discontinued. ORDERING INFORMATION HC Contact arrangement 1: 1 Form C 2: 2 Form C 3: 3 Form C 4: 4 Form C 4D: Bifurcated contact (twin) Nil: Standard type E: Amber sealed type (Only 1 Form C and 2 Form C) ED: Amber sealed type bifurcated contact (twin) (Only 4 Form C) K: Keep type Terminal arrangement H: Plug-in type HL: Plug-in with LED indication L: Plug-in with LED indication (Amber sealed type) HP: PC board type PL: PC board with LED indication HPL: PC board with LED indication (Amber sealed type) HTM: TM type Nominal coil voltage AC 6, 12, 24, 48, 100 (100/110), 120 (110/120), 200 (200/220), 240 (220/240) V DC 6, 12, 24, 48, 100 (100/110) V Surge suppression D: With diode R: With CR curcuit Contact material Contact material Contact arrangement 1 Form C 2 Form C 3 Form C 4 Form C 4-pole bifurcated (twin) AgSnO2 type AgNi type F F F Nil Nil Notes: Certified by UL and CSA (except for keep type) Please consult us about VDE (1 Form C, 2 Form C, and 4 Form C only) and TV-3 (1 Form C and 2 Form C only) approved products. ds_61C04_en_hc: 220512D 1 HC Products marked are discontinued as of August 31, 2012 LINEUP Type Contact arrangement Remarks Plug-in terminal type HC relay Standard type Without LED With LED Without LED With LED Top mounting type (TM type) 1 Form C A A A A A 2 Form C A A A A A 3 Form C A A A A A 4 Form C A A A A A 4 Form C A A A A A 1 Form C A A A A A 2 Form C A A A A A 4 Form C A A A A A Bifurcated (Twin) 4 Form C A A A A A Single side stable 2 Form C A (With operating indication) -- A (With operating indication) -- -- Single side stable Bifurcated (Twin) HC relay Amber sealed type HC keep (latching) relay DC type with surge absorbing diode Single side stable Single side stable Bifurcated (Twin) AC type with surge absorbing CR circuit PC board terminal type Single side stable Bifurcated (Twin) 1 Form C A A -- -- -- 2 Form C A A -- -- -- 3 Form C A A -- -- -- 4 Form C A A -- -- -- 4 Form C A A -- -- -- 1 Form C A A -- -- -- 2 Form C A A -- -- -- 3 Form C A A -- -- -- 4 Form C A A -- -- -- 4 Form C A A -- -- -- Amber sealed type also available 17 mm higher than standard type A: Available Notes: 1. HC relays with ground terminals also available. 2. HC relays with 0.9 mm wide PC board terminals also available. HC RELAY CONTACT ARRANGEMENT Type Single side stable contact Part number HC Features 4-pole bifurcated (twin) contact HC4D Suitable for high-capacity load switching Standard type HC relays have high single-contact capacity; 1 Form C: 10 A 2 Form C and 3 Form C: 7 A 4 Form C: 5 A Bifurcated (twin) contact ensures high contact reliability Suitable for low level loads Minimum switching capability: 100 A 100m V DC (reference value) LED INDICATION TYPE Type With LED indication type Part number HC-HL Features LED lights up when relay is operating Inspection and detection of trouble is easy. LEDs are green for DC types and red for AC types. All types are available with LED indication. 2 3 4 5 6 7 8 9 10 11 12 13 - +14 LED * LED colors indicate the type of relay: red for AC type and green for DC type. 2 1 Protection diode (Bottom view) ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 HC RELAY SERIES PRODUCT TYPES Type Amber sealed type HC relay Part number HCE Features HC keep (Latching) relay HC relay with diode type (for DC) HC--V-D HC2K Relay is completely sealed with resin. Provides high reliability in adverse surroundings. Suitable for use in dusty conditions or where organic gases are present Has built-in diode to absorb surge when the coil goes to the off state (for DC type). Magnetic latching relay Suitable for protecting relay driver circuits and Suitable for nominal operating power saving of for noise suppression operating circuits and for memory circuits Diode characteristics: Has operating indication (mechanical indicator). Reverse breakdown voltage 1,000 V Forward current 1 A Type HC relay with CR circuit (for AC) -- -- Part number HC--V-R -- -- -- -- Features Has built-in CR circuit to absorb surge when the coil goes to the off state (for AC). Relay with CR circuit is 17 mm higher than standard type relay. 4-pole bifurcated (twin) type and Relay with LED indication are available. TYPES 1. Standard type 1) Plug-in type Nominal coil voltage 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1-H-AC6V-F HC2-H-AC6V-F HC3-H-AC6V-F HC4-H-AC6V HC4D-H-AC6V 12V AC HC1-H-AC12V-F HC2-H-AC12V-F HC3-H-AC12V-F HC4-H-AC12V HC4D-H-AC12V 24V AC HC1-H-AC24V-F HC2-H-AC24V-F HC3-H-AC24V-F HC4-H-AC24V HC4D-H-AC24V 48V AC HC1-H-AC48V-F HC2-H-AC48V-F HC3-H-AC48V-F HC4-H-AC48V HC4D-H-AC48V 100/110V AC HC1-H-AC100V-F HC2-H-AC100V-F HC3-H-AC100V-F HC4-H-AC100V HC4D-H-AC100V 110/120V AC HC1-H-AC120V-F HC2-H-AC120V-F HC3-H-AC120V-F HC4-H-AC120V HC4D-H-AC120V 200/220V AC HC1-H-AC200V-F HC2-H-AC200V-F HC3-H-AC200V-F HC4-H-AC200V HC4D-H-AC200V 220/240V AC HC1-H-AC240V-F HC2-H-AC240V-F HC3-H-AC240V-F HC4-H-AC240V HC4D-H-AC240V 6V DC HC1-H-DC6V-F HC2-H-DC6V-F HC3-H-DC6V-F HC4-H-DC6V HC4D-H-DC6V 12V DC HC1-H-DC12V-F HC2-H-DC12V-F HC3-H-DC12V-F HC4-H-DC12V HC4D-H-DC12V 24V DC HC1-H-DC24V-F HC2-H-DC24V-F HC3-H-DC24V-F HC4-H-DC24V HC4D-H-DC24V 48V DC HC1-H-DC48V-F HC2-H-DC48V-F HC3-H-DC48V-F HC4-H-DC48V HC4D-H-DC48V 100/110V DC HC1-H-DC100V-F HC2-H-DC100V-F HC3-H-DC100V-F HC4-H-DC100V HC4D-H-DC100V 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (with LED indication) Nominal coil voltage 4 Form C (twin) Part No. 6V AC HC1-HL-AC6V-F HC2-HL-AC6V-F HC3-HL-AC6V-F HC4-HL-AC6V HC4D-HL-AC6V 12V AC HC1-HL-AC12V-F HC2-HL-AC12V-F HC3-HL-AC12V-F HC4-HL-AC12V HC4D-HL-AC12V 24V AC HC1-HL-AC24V-F HC2-HL-AC24V-F HC3-HL-AC24V-F HC4-HL-AC24V HC4D-HL-AC24V 100/110V AC HC1-HL-AC100V-F HC2-HL-AC100V-F HC3-HL-AC100V-F HC4-HL-AC100V HC4D-HL-AC100V 110/120V AC HC1-HL-AC120V-F HC2-HL-AC120V-F HC3-HL-AC120V-F HC4-HL-AC120V HC4D-HL-AC120V 200/220V AC HC1-HL-AC200V-F HC2-HL-AC200V-F HC3-HL-AC200V-F HC4-HL-AC200V HC4D-HL-AC200V 220/240V AC HC1-HL-AC240V-F HC2-HL-AC240V-F HC3-HL-AC240V-F HC4-HL-AC240V HC4D-HL-AC240V 6V DC HC1-HL-DC6V-F HC2-HL-DC6V-F HC3-HL-DC6V-F HC4-HL-DC6V HC4D-HL-DC6V 12V DC HC1-HL-DC12V-F HC2-HL-DC12V-F HC3-HL-DC12V-F HC4-HL-DC12V HC4D-HL-DC12V 24V DC HC1-HL-DC24V-F HC2-HL-DC24V-F HC3-HL-DC24V-F HC4-HL-DC24V HC4D-HL-DC24V 48V DC HC1-HL-DC48V-F HC2-HL-DC48V-F HC3-HL-DC48V-F HC4-HL-DC48V HC4D-HL-DC48V 100/110V DC HC1-HL-DC100V-F HC2-HL-DC100V-F HC3-HL-DC100V-F HC4-HL-DC100V HC4D-HL-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. ds_61C04_en_hc: 220512D 3 HC Products marked are discontinued as of August 31, 2012 3) PC board type Nominal coil voltage 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1-HP-AC6V-F HC2-HP-AC6V-F HC3-HP-AC6V-F HC4-HP-AC6V HC4D-HP-AC6V 12V AC HC1-HP-AC12V-F HC2-HP-AC12V-F HC3-HP-AC12V-F HC4-HP-AC12V HC4D-HP-AC12V 24V AC HC1-HP-AC24V-F HC2-HP-AC24V-F HC3-HP-AC24V-F HC4-HP-AC24V HC4D-HP-AC24V 48V AC HC1-HP-AC48V-F HC2-HP-AC48V-F HC3-HP-AC48V-F HC4-HP-AC48V HC4D-HP-AC48V 100/110V AC HC1-HP-AC100V-F HC2-HP-AC100V-F HC3-HP-AC100V-F HC4-HP-AC100V HC4D-HP-AC100V 110/120V AC HC1-HP-AC120V-F HC2-HP-AC120V-F HC3-HP-AC120V-F HC4-HP-AC120V HC4D-HP-AC120V 200/220V AC HC1-HP-AC200V-F HC2-HP-AC200V-F HC3-HP-AC200V-F HC4-HP-AC200V HC4D-HP-AC200V 220/240V AC HC1-HP-AC240V-F HC2-HP-AC240V-F HC3-HP-AC240V-F HC4-HP-AC240V HC4D-HP-AC240V 6V DC HC1-HP-DC6V-F HC2-HP-DC6V-F HC3-HP-DC6V-F HC4-HP-DC6V HC4D-HP-DC6V 12V DC HC1-HP-DC12V-F HC2-HP-DC12V-F HC3-HP-DC12V-F HC4-HP-DC12V HC4D-HP-DC12V 24V DC HC1-HP-DC24V-F HC2-HP-DC24V-F HC3-HP-DC24V-F HC4-HP-DC24V HC4D-HP-DC24V 48V DC HC1-HP-DC48V-F HC2-HP-DC48V-F HC3-HP-DC48V-F HC4-HP-DC48V HC4D-HP-DC48V 100/110V DC HC1-HP-DC100V-F HC2-HP-DC100V-F HC3-HP-DC100V-F HC4-HP-DC100V HC4D-HP-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add "-31" before "-F" in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HP-AC6V-31-F. 4) PC board type (with LED indication) Nominal coil voltage 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1-HPL-AC6V-F HC2-HPL-AC6V-F HC3-HPL-AC6V-F HC4-HPL-AC6V HC4D-HPL-AC6V 12V AC HC1-HPL-AC12V-F HC2-HPL-AC12V-F HC3-HPL-AC12V-F HC4-HPL-AC12V HC4D-HPL-AC12V 24V AC HC1-HPL-AC24V-F HC2-HPL-AC24V-F HC3-HPL-AC24V-F HC4-HPL-AC24V HC4D-HPL-AC24V 100/110V AC HC1-HPL-AC100V-F HC2-HPL-AC100V-F HC3-HPL-AC100V-F HC4-HPL-AC100V HC4D-HPL-AC100V 110/120V AC HC1-HPL-AC120V-F HC2-HPL-AC120V-F HC3-HPL-AC120V-F HC4-HPL-AC120V HC4D-HPL-AC120V 200/220V AC HC4D-HPL-AC200V HC1-HPL-AC200V-F HC2-HPL-AC200V-F HC3-HPL-AC200V-F HC4-HPL-AC200V 6V DC HC1-HPL-DC6V-F HC2-HPL-DC6V-F HC3-HPL-DC6V-F HC4-HPL-DC6V HC4D-HPL-DC6V 12V DC HC1-HPL-DC12V-F HC2-HPL-DC12V-F HC3-HPL-DC12V-F HC4-HPL-DC12V HC4D-HPL-DC12V 24V DC HC1-HPL-DC24V-F HC2-HPL-DC24V-F HC3-HPL-DC24V-F HC4-HPL-DC24V HC4D-HPL-DC24V 48V DC HC1-HPL-DC48V-F HC2-HPL-DC48V-F HC3-HPL-DC48V-F HC4-HPL-DC48V HC4D-HPL-DC48V 100/110V DC HC1-HPL-DC100V-F HC2-HPL-DC100V-F HC3-HPL-DC100V-F HC4-HPL-DC100V HC4D-HPL-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add "-31" before "-F" in the part number when ordering the PC board type 0.9 mm width terminal (ex) HC1-HPL-AC6V-31-F. 5) TM type Nominal coil voltage 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1-HTM-AC6V-F HC2-HTM-AC6V-F HC3-HTM-AC6V-F HC4-HTM-AC6V HC4D-HTM-AC6V 12V AC HC1-HTM-AC12V-F HC2-HTM-AC12V-F HC3-HTM-AC12V-F HC4-HTM-AC12V HC4D-HTM-AC12V 24V AC HC1-HTM-AC24V-F HC2-HTM-AC24V-F HC3-HTM-AC24V-F HC4-HTM-AC24V HC4D-HTM-AC24V 48V AC HC1-HTM-AC48V-F HC2-HTM-AC48V-F HC3-HTM-AC48V-F HC4-HTM-AC48V HC4D-HTM-AC48V 100/110V AC HC1-HTM-AC100V-F HC2-HTM-AC100V-F HC3-HTM-AC100V-F HC4-HTM-AC100V HC4D-HTM-AC100V 110/120V AC HC1-HTM-AC120V-F HC2-HTM-AC120V-F HC3-HTM-AC120V-F HC4-HTM-AC120V HC4D-HTM-AC120V 200/220V AC HC1-HTM-AC200V-F HC2-HTM-AC200V-F HC3-HTM-AC200V-F HC4-HTM-AC200V HC4D-HTM-AC200V 6V DC HC1-HTM-DC6V-F HC2-HTM-DC6V-F HC3-HTM-DC6V-F HC4-HTM-DC6V HC4D-HTM-DC6V 12V DC HC1-HTM-DC12V-F HC2-HTM-DC12V-F HC3-HTM-DC12V-F HC4-HTM-DC12V HC4D-HTM-DC12V 24V DC HC1-HTM-DC24V-F HC2-HTM-DC24V-F HC3-HTM-DC24V-F HC4-HTM-DC24V HC4D-HTM-DC24V 48V DC HC1-HTM-DC48V-F HC2-HTM-DC48V-F HC3-HTM-DC48V-F HC4-HTM-DC48V HC4D-HTM-DC48V 100/110V DC HC1-HTM-DC100V-F HC2-HTM-DC100V-F HC3-HTM-DC100V-F HC4-HTM-DC100V HC4D-HTM-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 4 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 2. Amber sealed type 1) Plug-in type Nominal coil voltage 1 Form C 2 Form C 4 Form C Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1E-H-AC6V-F HC2E-H-AC6V-F HC4E-H-AC6V HC4ED-H-AC6V 12V AC HC1E-H-AC12V-F HC2E-H-AC12V-F HC4E-H-AC12V HC4ED-H-AC12V 24V AC HC1E-H-AC24V-F HC2E-H-AC24V-F HC4E-H-AC24V HC4ED-H-AC24V 48V AC HC1E-H-AC48V-F HC2E-H-AC48V-F HC4E-H-AC48V HC4ED-H-AC48V 100/110V AC HC1E-H-AC100V-F HC2E-H-AC100V-F HC4E-H-AC100V HC4ED-H-AC100V 110/120V AC HC1E-H-AC120V-F HC2E-H-AC120V-F HC4E-H-AC120V HC4ED-H-AC120V 200/220V AC HC1E-H-AC200V-F HC2E-H-AC200V-F HC4E-H-AC200V HC4ED-H-AC200V 220/240V AC HC4ED-H-AC240V HC1E-H-AC240V-F HC2E-H-AC240V-F HC4E-H-AC240V 6V DC HC1E-H-DC6V-F HC2E-H-DC6V-F HC4E-H-DC6V HC4ED-H-DC6V 12V DC HC1E-H-DC12V-F HC2E-H-DC12V-F HC4E-H-DC12V HC4ED-H-DC12V 24V DC HC1E-H-DC24V-F HC2E-H-DC24V-F HC4E-H-DC24V HC4ED-H-DC24V 48V DC HC1E-H-DC48V-F HC2E-H-DC48V-F HC4E-H-DC48V HC4ED-H-DC48V 100/110V DC HC1E-H-DC100V-F HC2E-H-DC100V-F HC4E-H-DC100V HC4ED-H-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (With LED indication) Nominal coil voltage 1 Form C 2 Form C 4 Form C Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1E-L-AC6V-F HC2E-L-AC6V-F HC4E-L-AC6V HC4ED-L-AC6V 12V AC HC1E-L-AC12V-F HC2E-L-AC12V-F HC4E-L-AC12V HC4ED-L-AC12V 24V AC HC1E-L-AC24V-F HC2E-L-AC24V-F HC4E-L-AC24V HC4ED-L-AC24V 48V AC HC1E-L-AC48V-F HC2E-L-AC48V-F HC4E-L-AC48V HC4ED-L-AC48V 100/110V AC HC1E-L-AC100V-F HC2E-L-AC100V-F HC4E-L-AC100V HC4ED-L-AC100V 110/120V AC HC1E-L-AC120V-F HC2E-L-AC120V-F HC4E-L-AC120V HC4ED-L-AC120V 200/220V AC HC1E-L-AC200V-F HC2E-L-AC200V-F HC4E-L-AC200V HC4ED-L-AC200V 220/240V AC HC1E-L-AC240V-F HC2E-L-AC240V-F HC4E-L-AC240V HC4ED-L-AC240V 6V DC HC1E-L-DC6V-F HC2E-L-DC6V-F HC4E-L-DC6V HC4ED-L-DC6V 12V DC HC1E-L-DC12V-F HC2E-L-DC12V-F HC4E-L-DC12V HC4ED-L-DC12V 24V DC HC1E-L-DC24V-F HC2E-L-DC24V-F HC4E-L-DC24V HC4ED-L-DC24V 48V DC HC1E-L-DC48V-F HC2E-L-DC48V-F HC4E-L-DC48V HC4ED-L-DC48V 100/110V DC HC1E-L-DC100V-F HC2E-L-DC100V-F HC4E-L-DC100V HC4ED-L-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 3) PC board type 1 Form C 2 Form C 4 Form C Part No. Part No. Part No. 6V AC HC1E-HP-AC6V-F HC2E-HP-AC6V-F HC4E-HP-AC6V HC4ED-HP-AC6V 12V AC HC1E-HP-AC12V-F HC2E-HP-AC12V-F HC4E-HP-AC12V HC4ED-HP-AC12V 24V AC HC1E-HP-AC24V-F HC2E-HP-AC24V-F HC4E-HP-AC24V HC4ED-HP-AC24V 48V AC HC1E-HP-AC48V-F HC2E-HP-AC48V-F HC4E-HP-AC48V HC4ED-HP-AC48V 100/110V AC HC1E-HP-AC100V-F HC2E-HP-AC100V-F HC4E-HP-AC100V HC4ED-HP-AC100V 110/120V AC HC1E-HP-AC120V-F HC2E-HP-AC120V-F HC4E-HP-AC120V HC4ED-HP-AC120V 200/220V AC HC1E-HP-AC200V-F HC2E-HP-AC200V-F HC4E-HP-AC200V HC4ED-HP-AC200V 220/240V AC HC1E-HP-AC240V-F HC2E-HP-AC240V-F HC4E-HP-AC240V HC4ED-HP-AC240V 6V DC HC1E-HP-DC6V-F HC2E-HP-DC6V-F HC4E-HP-DC6V HC4ED-HP-DC6V 12V DC HC1E-HP-DC12V-F HC2E-HP-DC12V-F HC4E-HP-DC12V HC4ED-HP-DC12V 24V DC HC1E-HP-DC24V-F HC2E-HP-DC24V-F HC4E-HP-DC24V HC4ED-HP-DC24V 48V DC HC1E-HP-DC48V-F HC2E-HP-DC48V-F HC4E-HP-DC48V HC4ED-HP-DC48V 100/110V DC HC1E-HP-DC100V-F HC2E-HP-DC100V-F HC4E-HP-DC100V HC4ED-HP-DC100V Nominal coil voltage 4 Form C (twin) Part No. Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add "-31" in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only) ds_61C04_en_hc: 220512D 5 HC Products marked are discontinued as of August 31, 2012 4) PC board type (With LED indication) Nominal coil voltage 1 Form C 2 Form C 4 Form C Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1E-PL-AC6V-F HC2E-PL-AC6V-F HC4E-PL-AC6V HC4ED-PL-AC6V 12V AC HC1E-PL-AC12V-F HC2E-PL-AC12V-F HC4E-PL-AC12V HC4ED-PL-AC12V 24V AC HC1E-PL-AC24V-F HC2E-PL-AC24V-F HC4E-PL-AC24V HC4ED-PL-AC24V 48V AC HC1E-PL-AC48V-F HC2E-PL-AC48V-F HC4E-PL-AC48V HC4ED-PL-AC48V 100/110V AC HC1E-PL-AC100V-F HC2E-PL-AC100V-F HC4E-PL-AC100V HC4ED-PL-AC100V 110/120V AC HC1E-PL-AC120V-F HC2E-PL-AC120V-F HC4E-PL-AC120V HC4ED-PL-AC120V 200/220V AC HC1E-PL-AC200V-F HC2E-PL-AC200V-F HC4E-PL-AC200V HC4ED-PL-AC200V 220/240V AC HC4ED-PL-AC240V HC1E-PL-AC240V-F HC2E-PL-AC240V-F HC4E-PL-AC240V 6V DC HC1E-PL-DC6V-F HC2E-PL-DC6V-F HC4E-PL-DC6V HC4ED-PL-DC6V 12V DC HC1E-PL-DC12V-F HC2E-PL-DC12V-F HC4E-PL-DC12V HC4ED-PL-DC12V 24V DC HC1E-PL-DC24V-F HC2E-PL-DC24V-F HC4E-PL-DC24V HC4ED-PL-DC24V 48V DC HC1E-PL-DC48V-F HC2E-PL-DC48V-F HC4E-PL-DC48V HC4ED-PL-DC48V 100/110V DC HC1E-PL-DC100V-F HC2E-PL-DC100V-F HC4E-PL-DC100V HC4ED-PL-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please add "-31" in the suffix of part number when ordering the PC board type 0.9 mm width terminal. (4 Form C, 4 Form C (twin) only) 5) TM type Nominal coil voltage 1 Form C 2 Form C 4 Form C Part No. Part No. Part No. 4 Form C (twin) Part No. 6V AC HC1E-HTM-AC6V-F HC2E-HTM-AC6V-F HC4E-HTM-AC6V HC4ED-HTM-AC6V 12V AC HC1E-HTM-AC12V-F HC2E-HTM-AC12V-F HC4E-HTM-AC12V HC4ED-HTM-AC12V 24V AC HC1E-HTM-AC24V-F HC2E-HTM-AC24V-F HC4E-HTM-AC24V HC4ED-HTM-AC24V 48V AC HC1E-HTM-AC48V-F HC2E-HTM-AC48V-F HC4E-HTM-AC48V HC4ED-HTM-AC48V 100/110V AC HC1E-HTM-AC100V-F HC2E-HTM-AC100V-F HC4E-HTM-AC100V HC4ED-HTM-AC100V 110/120V AC HC1E-HTM-AC120V-F HC2E-HTM-AC120V-F HC4E-HTM-AC120V HC4ED-HTM-AC120V 200/220V AC HC1E-HTM-AC200V-F HC2E-HTM-AC200V-F HC4E-HTM-AC200V HC4ED-HTM-AC200V 220/240V AC HC4ED-HTM-AC240V HC1E-HTM-AC240V-F HC2E-HTM-AC240V-F HC4E-HTM-AC240V 6V DC HC1E-HTM-DC6V-F HC2E-HTM-DC6V-F HC4E-HTM-DC6V HC4ED-HTM-DC6V 12V DC HC1E-HTM-DC12V-F HC2E-HTM-DC12V-F HC4E-HTM-DC12V HC4ED-HTM-DC12V 24V DC HC1E-HTM-DC24V-F HC2E-HTM-DC24V-F HC4E-HTM-DC24V HC4ED-HTM-DC24V 48V DC HC1E-HTM-DC48V-F HC2E-HTM-DC48V-F HC4E-HTM-DC48V HC4ED-HTM-DC48V 100/110V DC HC1E-HTM-DC100V-F HC2E-HTM-DC100V-F HC4E-HTM-DC100V HC4ED-HTM-DC100V Standard packing: Carton: 20 pcs.; Case: 200 pcs. 3. Keep relay Nominal coil voltage Plug-in type (2c) Part No. PC board type (2c) Part No. 6V AC HC2K-AC6V-F HC2K-P-AC6V-F 12V AC HC2K-AC12V-F HC2K-P-AC12V-F 24V AC HC2K-AC24V-F HC2K-P-AC24V-F 48V AC HC2K-AC48V-F HC2K-P-AC48V-F 100V AC HC2K-AC100V-F HC2K-P-AC100V-F 6V DC HC2K-DC6V-F HC2K-P-DC6V-F 12V DC HC2K-DC12V-F HC2K-P-DC12V-F 24V DC HC2K-DC24V-F HC2K-P-DC24V-F 48V DC HC2K-DC48V-F HC2K-P-DC48V-F 100/110V DC HC2K-DC100V-F HC2K-P-DC100V-F Standard packing: Carton: 20 pcs.; Case: 200 pcs. Note: Please refer to the "Standards Chart" for product certification. 6 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 4. With diode type (For DC) 1) Plug-in type Nominal coil voltage 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. 4 Form C (twin) Part No. 6V DC HC1-DC6V-D-F HC2-DC6V-D-F HC3-DC6V-D-F HC4-DC6V-D HC4D-DC6V-D 12V DC HC1-DC12V-D-F HC2-DC12V-D-F HC3-DC12V-D-F HC4-DC12V-D HC4D-DC12V-D 24V DC HC1-DC24V-D-F HC2-DC24V-D-F HC3-DC24V-D-F HC4-DC24V-D HC4D-DC24V-D 48V DC HC1-DC48V-D-F HC2-DC48V-D-F HC3-DC48V-D-F HC4-DC48V-D HC4D-DC48V-D 100/110V DC HC1-DC100V-D-F HC2-DC100V-D-F HC3-DC100V-D-F HC4-DC100V-D HC4D-DC100V-D Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (with LED indication) Nominal coil voltage 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. 4 Form C (twin) Part No. 6V DC HC1-L-DC6V-D-F HC2-L-DC6V-D-F HC3-L-DC6V-D-F HC4-L-DC6V-D HC4D-L-DC6V-D 12V DC HC1-L-DC12V-D-F HC2-L-DC12V-D-F HC3-L-DC12V-D-F HC4-L-DC12V-D HC4D-L-DC12V-D 24V DC HC1-L-DC24V-D-F HC2-L-DC24V-D-F HC3-L-DC24V-D-F HC4-L-DC24V-D HC4D-L-DC24V-D 48V DC HC1-L-DC48V-D-F HC2-L-DC48V-D-F HC3-L-DC48V-D-F HC4-L-DC48V-D HC4D-L-DC48V-D 100/110V DC HC1-L-DC100V-D-F HC2-L-DC100V-D-F HC3-L-DC100V-D-F HC4-L-DC100V-D HC4D-L-DC100V-D 1 Form C 2 Form C 3 Form C 4 Form C Part No. Part No. Part No. Part No. Part No. HC1-AC100V-R-F HC2-AC100V-R-F HC3-AC100V-R-F HC4-AC100V-R HC4D-AC100V-R Standard packing: Carton: 20 pcs.; Case: 200 pcs. 5. With CR circuit type 1) Plug-in type Nominal coil voltage 100/110V AC 4 Form C (twin) 110/120V AC HC1-AC120V-R-F HC2-AC120V-R-F HC3-AC120V-R-F HC4-AC120V-R HC4D-AC120V-R 200/220V AC HC1-AC200V-R-F HC2-AC200V-R-F HC3-AC200V-R-F HC4-AC200V-R HC4D-AC200V-R 220/240V AC HC1-AC240V-R-F HC2-AC240V-R-F HC3-AC240V-R-F HC4-AC240V-R HC4D-AC240V-R 1 Form C 2 Form C 3 Form C 4 Form C 4 Form C (twin) Part No. Part No. Part No. Part No. Part No. HC1-L-AC100V-R-F HC2-L-AC100V-R-F HC3-L-AC100V-R-F HC4-L-AC100V-R HC4D-L-AC100V-R Standard packing: Carton: 20 pcs.; Case: 200 pcs. 2) Plug-in type (with LED indication) Nominal coil voltage 100/110V AC 110/120V AC HC1-L-AC120V-R-F HC2-L-AC120V-R-F HC3-L-AC120V-R-F HC4-L-AC120V-R HC4D-L-AC120V-R 200/220V AC HC1-L-AC200V-R-F HC2-L-AC200V-R-F HC3-L-AC200V-R-F HC4-L-AC200V-R HC4D-L-AC200V-R 220/240V AC HC1-L-AC240V-R-F HC2-L-AC240V-R-F HC3-L-AC240V-R-F HC4-L-AC240V-R HC4D-L-AC240V-R Standard packing: Carton: 20 pcs.; Case: 200 pcs. * For sockets and terminal sockets, see page 20. RATING 1. Standard type 1) Coil data (1) AC coils (50/60Hz) Type Nominal coil voltage Drop-out voltage (at 20C 68F) Nominal coil current [20%] (at 20C 68F) Coil inductance 50Hz 60Hz N.C. condition 6V AC 224mA 200mA 0.078H 12V AC 111mA 100mA 0.312H 0.295H 56mA 50mA 1.243H 1.181H 28mA 25mA 4.974H 4.145H 20.63H 24V AC Standard Pick-up voltage (at 20C 68F) 48V AC 100/110V AC 80%V or less of nominal voltage (Initial) 30%V or more of nominal voltage (Initial) N.O. condition 0.074H 13.4/14.7mA 12/13.2mA 23.75H 110/120V AC 12.2/13.5mA 10.9/11.9mA 27.19H 25.57H 200/220V AC 6.7/7.4mA 6/6.6mA 85.98H 81.76H Nominal operating power 50Hz 60Hz 1.3VA 1.2VA Max. applied voltage (at 70C 158F) 110%V of nominal voltage Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow leading possibly to coil burnout. 2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) ds_61C04_en_hc: 220512D 7 HC Products marked are discontinued as of August 31, 2012 (2) DC coils Nominal coil voltage Type Pick-up voltage (at 20C 68F) Drop-out voltage (at 20C 68F) 80%V or less of nominal voltage (Initial) 10%V or more of nominal voltage (Initial) 6V DC 12V DC Standard 24V DC 48V DC 100/110V DC Nominal coil current [10%] (at 20C 68F) Coil resistance [10%] (at 20C 68F) 150mA 40 75mA 160 37mA 650 18.5mA 2,600 10/11mA 10,000 Nominal operating power Max. applied voltage (at 70C 158F) 0.9W 110%V of nominal voltage 1.0W Notes: 1. The coil resistance for DC operation is the value measured when the coil temperature is 20C 68F. Compensate 0.4% for every 1C change in temperature. 2. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the rated voltage. 3. For use with 200 V DC, connect a 10 K (5W) resistor, in series, to the 100 V DC relay. 4. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) 2) Specifications Characteristics Item Arrangement Contact Specifications 1 Form C 2 Form C Contact resistance (Initial) Contact material Max. switching power (resistive load) Max. switching current 10A 250V AC 7A 250V AC 7A 250V AC 5A 250V AC 3A 250V AC 2,500VA 1,750VA 1,750VA 1,250VA 750VA 5A 3A 250VAC 10A 7A Nominal operating power Electrical characteristics 1mA 1V DC Between open contacts 700 Vrms for 1min. (Detection current: 10mA.) Between contact sets 700 Vrms for 1min. (Detection current: 10mA.) Between contact and coil 2,000 Vrms for 1min. (Detection current: 10mA.) Conditions Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) Release time (at 20C 68F)*2 Max. 20ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Shock resistance Vibration resistance Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) Functional Destructive Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.) Functional 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10s.) Destructive Electrical Conditions for operation, transport and storage*3 Max. Operating speed Unit weight Max. 80C 176F (By resistive method, nominal coil voltage) Operate time (at 20C 68F)*2 Mechanical Expected life 100A 1V DC Min. 1,000M (at 500V DC) Measurement at same location as "Breakdown voltage" section. Temperature rise (coil) (at 70C 158F) Mechanical characteristics 7A AC (50Hz): 1.3VA, AC (60Hz): 1.2VA, DC: 0.9 to 1.1W Min. switching capacity (Reference value)*1 Insulation resistance (Initial) 4 Form C (twin) AgNi type + Au clad Max. switching voltage Breakdown voltage (Initial) 4 Form C Ag alloy (cd free) + Au flash Nominal switching capacity (resistive load) Rating 3 Form C Max. 30 m (By voltage drop 6 V DC 1A) 10 to 55 Hz at double amplitude of 2 mm Min. 5107: AC coil type (at 180 times/min.); Min. 108: DC coil type (at 180 times/min.) Min. 2105 resistive load (at 20 times/min.) Min. 2105 resistive load (at 20 times/min.) Min. 105 resistive load (at 20 times/min.) Min. 2105 resistive load (at 20 times/min.) Min. 2105 resistive load (at 20 times/min.) Ambient temperature: -50C to +70C -58F to +158F (without LED); -50C to +60C -58F to +140F (with LED) Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) 20 times/min. (at max. rating) Approx. 30g 1.06 oz Notes: *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2. For the AC coil types, the operate/release time will differ depending on the phase. *3.The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to "6. Usage, Storage and Transport Conditions" in AMBIENT ENVIRONMENT section in Relay Technical Information. 8 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 3) Switching capacity and expected life (1) Electrical (at 20 times/min.) Load Voltage 1 Form C 2 Form C 3 Form C AC DC Resistive (cos = 1) Inductive (cos 0.4) Resistive Inductive Expected life 125V AC 250V AC 125V AC 250V AC 30V DC 30V DC 10A 10A 5A 3A -- -- Min. 2105 7A 7A 3A 2.5A 3A 1A Min. 5105 5A 5A 2A 1.5A -- -- Min. 106 7A 7A 3.5A 2A -- -- Min. 2105 5A 5A 2.5A 1.5A 3A 0.6A Min. 5105 3A 3A 1.5A 1A -- -- Min. 106 7A 7A -- -- -- -- Min. 105 -- -- 3.5A 2A -- -- Min. 2105 5A 5A -- -- 3A 0.4A Min. 5105 5A 5A 2A 1A -- -- Min. 2105 4 Form C 3A 3A 1A 0.8A 3A 0.4A Min. 5105 2A 2A 0.5A 0.4A -- -- Min. 106 4 Form C (twin) 3A 3A 1A 0.8A 3A -- Min. 2105 (2) Mechanical (at 180 times/min.) AC coil type: Min. 5107; DC coil type: Min. 108 2. Amber sealed type 1) Coil data Same coil data as HC relay standard type. Please refer to standard type information. 2) Specifications Characteristics Contact Specifications Item 1 Form C 2 Form C 4 Form C 1 Form C 2 Form C 4 Form C 4 Form C 5A 250V AC 3A 250V AC 2A 250V AC 1A 250V AC Arrangement Nominal switching capacity (resistive load) Rating 4 Form C (twin) Max. switching power (resistive load) 1,250VA 700VA 500VA 250VA Max. switching voltage 250VAC 250VAC 250VAC 250VAC Max. switching current 5A 3A 2A Min. switching capacity (Reference value)*1 Electrical characteristics Temperature rise (coil) (at 60C 140F) Expected life Electrical Conditions Conditions for operation, transport and storage*2 1A 1mA 100mV DC 100A 100mV DC Max. 90C 194F (By resistive method, nominal voltage) Min. 2105 resistive load (at 20 times/min.) Ambient temperature: -40C to +60C -40F to +140F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Ambient air pressure 760mmHg20% (1,013mb20%) Notes: Other specifications are same as standard types. *1. This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2.The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to "6. Usage, Storage and Transport Conditions" in AMBIENT ENVIRONMENT section in Relay Technical Information. 3) Switching capacity and expected life (1) Electrical (at 20 times/min.) AC Load Voltage Resistive (cos = 1) 125V AC 250V AC DC Inductive (cos 125V AC 0.4) Resistive Inductive 250V AC 30V DC 30V DC Expected life HC1E 5A 5A -- -- 3A 1A Min. 2105 HC2E 3A 3A -- -- 2A 0.7A Min. 2105 HC4E 2A 2A -- -- 2A 0.6A Min. 2105 HC4ED (4 Form C twin) 1A 1A -- -- -- -- Min. 2105 (2) Mechanical (at 180 times/min.) AC coil type: Min. 5107; DC coil type: Min. 108 ds_61C04_en_hc: 220512D 9 HC Products marked are discontinued as of August 31, 2012 3. Keep relay 1) Coil data (1) AC coils (50/60Hz) Contact arrangement 2 Form C Nominal coil voltage Set voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) Reset voltage (at 20C 68F) Nominal operating power Set coil Reset coil Set coil Reset coil 6V AC 206mA 103mA 1.23VA 0.62VA 12V AC 100mA 52mA 1.20VA 0.62VA 51mA 21.4mA 1.22VA 0.51VA 25.2mA 18.5mA 1.20VA 0.88VA 13.3mA 7.1mA 1.33VA 0.71VA 24V AC 48V AC 80%V or less of nominal voltage (Initial) 80%V or less of nominal voltage (Initial) 100V AC Max. applied voltage (at 50C 122F) 110%V of nominal voltage (2) DC coils Contact arrangement Nominal coil voltage Set voltage (at 20C 68F) Reset voltage (at 20C 68F) Nominal operating current [10%] (at 20C 68F) 6V DC 12V DC 2 Form C 24V DC 48V DC 80%V or less of nominal voltage (Initial) 80%V or less of nominal voltage (Initial) Coil resistance [10%] (at 20C 68F) Nominal operating power Set coil Reset coil Set coil Reset coil Set coil Reset coil 207mA 107mA 29 56 1.24W 0.64W 100mA 52.2mA 120 230 1.20W 0.63W 51.1mA 25.5mA 470 941 1.23W 0.61W 25.3mA 13.7mA 1,897 3,504 1.21W 0.66W Max. applied voltage (at 50C 122F) 110%V of nominal voltage 100V DC 15.6mA 5.8mA 6,410 17,241 1.56W 0.58W Notes: 1. The allowable coil resistance range is 10% when within 1,000 and 15% when. 1,000 or higher. 2. The maximum applied voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation. (This value differs depending on the ambient temperature. Please contact us for details.) 2) Specifications Characteristics Contact Rating Electrical characteristics Mechanical characteristics Expected life Item Specifications Contact resistance (Initial) Max. 50 m (By voltage drop 6 V DC 1A) Nominal switching capacity (resistive load) 3A 250V AC Max. switching power (resistive load) 750VA Max. switching current 3A Nominal operating power Set coil: 1.20VA to 1.33VA; Reset coil: 0.51VA to 0.88VA Min. switching capacity (Reference value)*1 100A 100mV DC Breakdown voltage (Initial) 1,500 Vrms for 1min. Between contact and coil Temperature rise (coil) Set coil: Max. 80C 176F; Reset coil: Max. 50C 122F (at nominal coil voltage) Set time/Reset time (at 20C 68F) Approx. 20ms/30ms (at nominal coil voltage) Shock resistance Min. 98m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10s.) Functional Mechanical Min. 107 (at 180 times/min.) Electrical Min. 2105 rated load (at 20 times/min.) Conditions Ambient temperature -40C to +50C -40F to +122F (Not freezing and condensing at low temperature) Notes:*1.This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the actual load. *2. Other specifications are same as standard type HC relay. Please see the standard type HC relay. *3. Please maintain (reset) the relay more than once a year. Leaving it in the set position for long periods of time will cause the magnet to attenuate over the years. This will decrease the holding power and cause failure of the set position. 4. With diode type (For DC) 1) Coil data Same coil data as HC relay standard type for DC. Please refer to standard type information. Please connect DC coil type built-in diode correctly by verifying the coil polarity. 2) Specifications Characteristics Conditions Item Specifications Conditions for operation, transport and storage* Ambient temperature: -50C to +60C -58F to +140F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay. * The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to "6. Usage, Storage and Transport Conditions" in AMBIENT ENVIRONMENT section in Relay Technical Information. 5. With CR circuit type 1) Coil data Same coil data as HC relay standard type for AC. Please refer to standard type information. 2) Specifications Characteristics Item Specifications Electrical characteristics Temperature rise (coil) Max. 90C 194F (By resistive method, nominal voltage, rated current at 60C 140F) Conditions Conditions for operation, transport and storage* Ambient temperature: -50C to +60C -58F to +140F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Notes: Other specifications are same as standard type HC relay. Please see the standard type HC relay. * The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to "6. Usage, Storage and Transport Conditions" in AMBIENT ENVIRONMENT section in Relay Technical Information. 10 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 REFERENCE DATA Standard type 1. Life curve 2.-(1) Switching capacity range (single contact type) Load: 250 V AC resistive load Mechanical life (DC type) 250 AC voltage, V Mechanical life (AC type) 500 AC voltage, V 5,000 4 Life, x10 times 10,000 2.-(2) Switching capacity range (4-pole bifurcated (twin) contact type) 100 HC4c 250 100 HC2c, 3c 400 1c 300 (250 V AC cos = 1) 10 100mV 2c HC1c 200 3c 100 4c 2 4 6 8 1mA 10 10mA Load current, A 3.-(1) Coil temperature rise (1 Form C, AC type) 5A 10A 7A 3.-(2) Coil temperature rise (2 Form C, AC type) Measured portion: Inside the coil Ambient temperature: 25C 77F (See note.) Measured portion: Inside the coil Ambient temperature: 30C 86F 100A (See note.) Measured portion: Inside the coil Ambient temperature: 18C 64F 70 7A 5A 2A 0A 60 50 40 5A 70 0A 60 50 40 50 40 30 20 10 10 10 0 0 120 80 90 100 110 0 120 0A 60 20 110 5A 70 20 100 7A 80 30 90 80 Coil applied voltage, %V Coil applied voltage, %V 90 100 3.-(6) Coil temperature rise (2 Form C, DC type) Measured portion: Inside the coil Ambient temperature: 15 to 21C 59 to 70F (See note.) Measured portion: Inside the coil Ambient temperature: 29C 84F Measured portion: Inside the coil Ambient temperature: 29C 84F 120 5A 100 3A 80 1A 60 40 20 0 80 90 100 110 120 100 100 90 90 80 70 60 10A 5A 0A 50 40 10 100 110 120 Coil applied voltage, %V Measured portion: Inside the coil Ambient temperature: 29C 84F Measured portion: Inside the coil Ambient temperature: 17 to 18C 62 to 64F 100 100 90 90 5A 60 0A 50 40 Temperature rise, C Temperature rise, C 3.-(8) Coil temperature rise (4 Form C, DC type) 7A 10 110 120 ds_61C04_en_hc: 220512D 110 120 When the nominal voltage is applied to AC 120 or 240 V coil types respectively, the figures of coil temperature rise increase by approx. 10 degrees to the ones shown on each graph. 40 20 100 100 Coil applied voltage, %V 3A 1A 50 10 Coil applied voltage, %V 90 5A 60 30 90 80 70 20 80 0 Note: Coil temperature rise 80 30 0 40 20 90 5A 0A 50 10 3.-(7) Coil temperature rise (3 Form C, DC type) 70 60 30 80 7A 70 20 0 120 80 30 Coil applied voltage, %V 80 Temperature rise, C 140 Temperature rise, C Temperature rise, C 3.-(5) Coil temperature rise (1 Form C, DC type) 160 110 Coil applied voltage, %V 3.-(4) Coil temperature rise (4 Form C, AC type) 180 (See note.) 90 10A 80 30 80 10A 100 Temperature rise, C 10A Temperature rise, C 80 3A 3.-(3) Coil temperature rise (3 Form C, AC type) 90 90 1A AC current 100 100 Temperature rise, C 1A AC current 0 80 90 100 110 120 Coil applied voltage, %V 11 HC Products marked are discontinued as of August 31, 2012 Amber sealed type 1.-(1) Switching capacity range (single contact type) 1.-(2) Switching capacity range (4-pole bifurcated (twin) contact type) 2.-(1) Coil temperature rise (1 Form C AC type) Measured portion: Inside the coil Ambient temperature: 30C 86F 100V HC4E 10V Temperature rise, C 250V AC voltage, V AC voltage, V 100 250 100 90 80 70 5A 60 50 40 100mV HC2E 30 HC1E 20 10 10mA 1A 2A 3A 5A 10A AC current 100A 1A 3A 0 10A 80 AC current 90 100 110 120 Voltage applied to coil, %V 2.-(3) Coil temperature rise (4 Form C AC type) 2.-(4) Coil temperature rise (1 Form C DC type) Measured portion: Inside the coil Ambient temperature: 30C 86F Measured portion: Inside the coil Ambient temperature: 30C 86F Measured portion: Inside the coil Ambient temperature: 30C 86F 100 100 90 90 80 70 3A 60 50 40 (See note.) 100 90 2A 80 70 60 50 40 Temperature rise, C (See note.) Temperature rise, C Temperature rise, C 2.-(2) Coil temperature rise (2 Form C AC type) 80 70 60 50 30 30 30 20 20 20 10 10 10 0 0 80 90 100 110 120 Voltage applied to coil, %V 2.-(5) Coil temperature rise (2 Form C DC type) Measured portion: Inside the coil Ambient temperature: 30C 86F 100 80 90 100 110 120 Voltage applied to coil, %V 5A 0A 40 0 80 90 100 110 120 Voltage applied to coil, %V When the nominal voltage is applied to AC 120 or 240 V coil types respectively, the figures of coil temperature rise increase by approx. 10 degrees to the ones shown on each graph. Temperature rise, C 90 80 70 60 5A 50 40 30 20 10 0 80 90 100 110 120 Voltage applied to coil, %V Note: Coil temperature rise Keep relay Coil temperature rise Tested sample: HC2K-DC12V, 2 pcs Measured portion: Inside the coil Ambient temperature: 28C 82.4F 100 Temperature rise, C 90 80 70 3A 0A 60 50 40 30 20 10 0 80 90 100 110 120 Coil applied voltage, %V 12 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 With diode type (For DC) 1.-(1) DC coil surge voltage waveform (without diode) 1.-(2) DC coil surge voltage waveform (with diode) Diode characteristics; Reverse breakdown voltage: 1,000V, Forward current: 1A ON OFF ON OFF 260V + 12V DC + - To digital memory 12V DC - To digital memory breakdown voltage: 1,000 V (Reverse ( Forward current: 1 A With CR circuit type 1.-(1) AC coil surge voltage waveform (with CR circuit) 1.-(2) AC coil surge voltage waveform (without CR circuit) Tested sample: HC4-AC200V-R Tested sample: HC4-AC200V 282V 282V 1.8ms 55V 3.2ms 200V AC 1.5ms To digital memory ds_61C04_en_hc: 220512D 630V 200V AC To digital memory 13 HC Products marked are discontinued as of August 31, 2012 DIMENSIONS (mm inch) Standard and Amber sealed types 1) Plug-in type 1 Form C CAD Data Data from our Web site. Download CAD External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 Schematic (Bottom view) Standard type 27.2 1.071 0.6 .024 2 7 12 13 14 35.2 1.386 1 .039 LED AC type 6.4 .252 2.54 .100 13.35 .526 4.45 4.41 .175 .174 2 7 12 13 14 2 0.5 .020 LED DC type 2 7 7 12 13 ( ) 12 13 14 ( ) 14 (+) (-) 4.06 .160 6.35 .250 6.35 .250 General tolerance: 0.3 .012 2 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 Schematic (Bottom view) Standard type 27.2 1.071 0.6 .024 1 5 9 13 4 8 12 14 35.2 1.386 LED AC type 1 .039 1 5 9 13 ( ) 6.4 .252 2.54 .100 4.41 13.35 .174 .526 1 4 5 8 9 12 13 14 0.5 .020 LED DC type 4 8 12 1 5 9 13 14 ( ) 4 8 12 14 (+) (-) 4.06 .160 6.35 .250 6.35 .250 General tolerance: 0.3 .012 3 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 Schematic (Bottom view) Standard type 0.6 .024 27.2 1.071 1 2 3 4 5 8 9 7 35.2 1.386 13 1 .039 0.5 .020 2.54 .100 4.41 13.35 .174 .526 2 3 4 5 6 7 8 13 9 14 14 LED AC type 6.4 .252 1 6 1 2 3 1 2 3 4 5 8 6 4 9 7 5 8 9 7 13 ( ) 4.06 .160 6.35 .250 6.35 .250 LED DC type 14 ( ) 13 (-) 6 14 (+) General tolerance: 0.3 .012 14 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 4 Form C and 4-pole bifurcated (twin) External dimensions CAD Data 1.7 .067 Schematic (Bottom view) Standard type 20.8 .819 1.7 .067 27.2 1.071 0.6 .024 35.2 1.386 2 3 4 6 7 8 9 10 11 12 13 13 ( ) 4.06 .160 6.35 .250 6.35 .250 14 4 7 8 9 10 11 12 14 LED DC type 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 0.5 .020 2.54 .100 4.41 13.35 .174 .526 5 3 6 LED AC type 6.4 .252 1 2 5 13 1 .039 4.45 .175 1 14 ( ) 13 (-) 14 (+) General tolerance: 0.3 .012 2) PC board type 4 Form C External dimensions CAD Data 20.8 .819 1.7 .067 1.7 .067 The diagrams show the external dimensions of the 4 Form C and 4-pole bifurcated (twin) types. For 1 Form C, 2 Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). Types with 0.9 mm terminal width are also available. 27.2 1.071 0.6 .024 35.2 1.386 1 .039 1.5 .059 13.35 .526 4.45 .175 1 2 3 1.5 .059 0.5 .020 4.41 .174 4 5 6 7 8 9 10 11 12 13 3.5 .138 14 4.06 .160 6.35 .250 6.35 .250 General tolerance: 0.3 .012 PC board pattern Schematic 1 Form C 2 Form C 4.1 .161 4.1 .161 10.4 .409 16.8 .661 4.45 .175 8.9 .350 13.35 .526 5-2 dia. hole 5-.079 dia. 3 Form C 8-2 dia. hole 8-.079 dia. 10.4 .409 16.8 .661 10.4 .409 16.8 .661 13.35 .526 11-2 dia. hole 11-.079 dia. Same schematic as plug-in type HC relay 4.1 .161 4.1 .161 10.4 .409 16.8 .661 13.35 .526 4 Form C 4.45 .175 8.9 .350 13.35 .526 14-2 dia. hole 14-.079 dia. Tolerance: 0.1 .004 ds_61C04_en_hc: 220512D 15 HC Products marked are discontinued as of August 31, 2012 3) TM type 4 Form C External dimensions CAD Data 20.6 .811 43 1.693 The diagrams show the external dimensions of the 4 Form C and 4-pole bifurcated (twin) types. For 1 Form C, 2 Form C, and 3 Form C, see diagrams at plug-in types (only the terminals are different). 2 .079 34.2 1.346 1 .039 6.4 .252 2.54 0.5 .100 .020 13.35 .526 4.45 .175 4.31 .170 3.6 .142 1 2 3 4 5 6 7 8 9 10 11 12 14 13 4.06 .160 37.6 6.35 27 1.480 .250 1.063 6.35 .250 General tolerance: 0.3 .012 Chassis (Panel) cutout Chassis (Panel) cutout in tandem mounting 2-3.6 dia. 2-.142 dia. 23 .906 37.6 1.480 37.6 1.480 Tolerance: 0.1 .004 21 .827 2 .079 Schematic 21 .827 Notes: 1. In mounting, use M3 screws and M3 washers. 2. When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. 3. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N*m, (3 to 5 kgf*cm). Moreover, use washers to prevent loosening. Same schematic as plug-in type HC relay Be aware that there is no LED indicator with CR circuit and built-in diode types. Keep relay Plug-in type (2 Form C) External dimensions CAD Data 27.4 1.079 21 .827 - 35.2 1.386 - 1 .039 6.4 .252 4.51 .178 1 2 3 4 5 6 7 8 9 10 11 12 14 AC type 1 4 1 5 8 5 9 13 11 10 Reset Set 12 14 + + 9 13 4 8 11 10 Reset 12 14 Set 6.9 .272 2.54 .100 13.35 .526 4.45 .175 13 Schematic (Bottom view) DC type 0.5 .020 4.06 .160 6.35 .250 6.35 .250 General tolerance: 0.3 .012 16 ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 PC board type (2 Form C) External dimensions CAD Data Schematic (Bottom view) DC type 27.2 1.071 21 .827 - 35.2 1.386 - 1 .039 1 4 1 5 8 5 12 9 13 Reset 14 Set + 4 8 10 13 + 11 12 Reset 14 Set PC board pattern (Bottom view) 3.5 .138 Idle terminal (hole needed) 21 .827 0.5 .020 4.51 .178 1 2 3 4 5 6 7 8 9 10 11 12 13 11 10 9 5.0 .197 1.5 .059 13.35 .526 4.45 .175 AC type 10.4 .409 16.8 27.4 .661 1.079 4.06 .160 6.35 .250 6.35 .250 14 14-2 dia. hole 14-.079 dia. hole 4.45 .175 General tolerance: 0.3 .012 8.9 .350 13.35 .526 4.1 .161 Tolerance: 0.1 .004 With diode type (For DC) Same dimensions as HC relay standard/plug-in type CAD Data Schematic Without LED indicator With LED indicator 1 2 3 4 1 2 3 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 +14 13- 4 +14 13- LED Protection (surge-absorbing) diode Protection (surge-absorbing) diode With CR circuit type Plug-in type CAD Data Schematic 4 Form C External dimensions 21 .827 27.4 1.079 Without LED indicator 52.3 2.059 With LED indicator 1 2 3 4 1 2 3 4 5 6 7 8 5 6 7 8 9 10 11 12 9 10 11 12 14 13 13 14 1 .039 6.4 .252 2.54 .100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 4.45 .175 13.35 .526 ds_61C04_en_hc: 220512D 0.5 .020 4.41 .174 4.06 .160 6.35 .250 6.35 .250 Diagrams show the external dimensions and schematic of the 4 Form C and 4-pole bifurcated (twin) types. For the 1 Form C, 2 Form C, and 3 Form C types, only the terminals differ. The dimensions of the terminal are the same as for standard type HC relays. General tolerance: 0.3 .012 17 HC Products marked are discontinued as of August 31, 2012 SAFETY STANDARDS Item UL/C-UL (Recognized) File No. LR26550 7A 250V AC 1/6HP 125, 250V AC etc. 3A 30V DC 7A 250V AC 40017406 1/6HP 125, 250V AC 3A 30V DC 7A 250V AC (cos=1.0) 2A 250V AC (cos=0.4) 3A 30V DC (0ms) TV-3 E43028 LR26550 7A 250V AC 1/6HP 125, 250V AC etc. 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC 5A 250V AC LR26550 1/10HP 125, 250V AC etc. 3A 30V DC 5A 250V AC 40017406 1/10HP 125, 250V AC 3A 30V DC E43149 3A 250V AC 3A 30V DC 3A 250V AC 3A 30V DC -- E43028 LR26550 6A 250V AC 1/6HP 125, 250V AC etc. 3A 30V DC 6A 250V AC 1/6HP 125, 250V AC 3A 30V DC 4A 250V AC LR26550 1/10HP 125, 250V AC etc. 3A 30V DC -- -- -- -- -- -- -- -- -- -- 4A 250V AC 1/10HP 125, 250V AC 3A 30V DC -- -- -- -- 2A 250V AC LR26550 1/20HP 125, 250V AC etc. 2A 30V DC 2A 250V AC 1/20HP 125, 250V AC 2A 30V DC -- -- -- -- E43149 1A 250V AC 1A 30V DC LR26550 etc. 1A 250V AC 1A 30V DC -- -- -- -- E43149 3A 250V AC 3A 30V DC LR26550 etc. 3A 250V AC 3A 30V DC -- -- -- -- E43028 LR26550 10A 250V AC 1/3HP 125, 250V AC etc. 3A 30V DC 10A 250V AC 1/3HP 125, 250V AC 3A 30V DC -- -- -- -- 7A 250V AC LR26550 1/6HP 125, 250V AC etc. 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC -- -- -- -- 7A 250V AC LR26550 1/6HP 125, 250V AC etc. 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC -- -- -- -- 5A 250V AC LR26550 1/10HP 125, 250V AC etc. 3A 30V DC 5A 250V AC 1/10HP 125, 250V AC 3A 30V DC -- -- -- -- E43149 3A 250V AC 3A 30V DC 3A 250V AC 3A 30V DC -- -- -- -- E43028 10A 250V AC LR26550 1/3HP 125, 250V AC etc. 3A 30V DC 10A 250V AC 1/3HP 125, 250V AC 3A 30V DC -- -- -- -- 7A 250V AC LR26550 1/6HP 125, 250V AC etc. 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC -- -- -- -- 7A 250V AC LR26550 1/6HP 125, 250V AC etc. 3A 30V DC 7A 250V AC 1/6HP 125, 250V AC 3A 30V DC -- -- -- -- 5A 250V AC LR26550 1/10HP 125, 250V AC etc. 3A 30V DC 5A 250V AC 1/10HP 125, 250V AC 3A 30V DC -- -- -- -- 3A 250V AC 3A 30V DC 3A 250V AC 3A 30V DC -- -- -- -- E43028 HC Amber E43028 4 Form C HC keep 1 Form C E43028 2 Form C E43028 E43028 4 Form C 1 Form C E43028 2 Form C E43028 E43028 4 Form C 18 E43149 LR26550 etc. LR26550 etc. LR26550 etc. -- -- UL E43149 CSA LR26550 -- 2 Form C 4 Form C twin Rating E43028 1 Form C HC with CR circuit 3 Form C TV rating (UL/CSA) File No. TV-3 E43028 4 Form C twin Contact rating 10A 250V AC (cos=1.0) UL 3A 250V AC (cos=0.4) E43149 3A 30V DC (0ms) CSA LR26550 4 Form C HC with diode type 3 Form C (For DC) VDE (Certified) File No. 10A 250V AC 40017406 1/3HP 125, 250V AC 3A 30V DC 3 Form C 4 Form C twin Contact rating 10A 250V AC LR26550 1/3HP 125, 250V AC etc. 3A 30V DC 2 Form C 4 Form C twin CSA (Certified) File No. E43028 1 Form C HC Standard Contact rating 5A 65V AC (cos=1.0) 3A 65V AC (cos=0.4) 3A 30V DC (0ms) Remarks Approved (DC type only) ds_61C04_en_hc: 220512D Products marked HC are discontinued as of August 31, 2012 NOTES 1. Amber sealed type When mounting TM types, use washers to prevent damage or distortion to the polycarbonate cover. When tightening fixing screws, the optimum torque range should be 0.294 to 0.49 N*m, (3 to 5 kgf*cm). If screws are over tightened, the cover may distort, resulting in poor sealing. Moreover, to prevent loosening, use washers. 2. Keep relay 1) The schematic differs from that in the standard type 4 Form C HC relay. Follow the schematic on the cover sticker. 2) Conform with the schematic for the DC type, which has a polarized coil. Item UL/C-UL (Recognized) File No. Contact rating 3) Because retention characteristics vary according to the waveform of the voltage applied to the coil, do your best to avoid capacitor driving. In capacitor driving, use a capacitor of 300 F or more. 4) Ensure that the minimum pulse width of voltage applied to coil is greater than 150 ms. 3. Diode characteristics 1) Reverse breakdown voltage: 1,000 V 2) Forward current: 1 A 4. Diode and CR built-in type Since the diode and CR inside the relay coil are designed to absorb the counter emf, the element may be damaged if a CSA (Certified) File No. Contact rating large surge, etc., is applied to the diode and CR. If there is the possibility of a large surge voltage from the outside, please implement measures to absorb it. 5. Please connect DC coil types with LED and built-in diode correctly by verifying the coil polarity ("+" and "- "). Connecting with reverse polarity will cause the LED not to light and damage the built-in diode due to its specification. VDE (Certified) File No. Contact rating TV rating (UL/CSA) File No. Rating Remarks For Cautions for Use, see Relay Technical Information. ds_61C04_en_hc: 220512D 19 Sockets marked HC are discontinued as of March 31, 2013 Products marked are discontinued as of August 31, 2012 HC RELAYS ACCESSORIES (Sockets and Terminal sockets) FEATURES 1. HC Relay Sockets 2. HC Relay Terminal sockets In the table below, the socket suitable for each type of HC relay is indicated by a black dot. In the table below, the terminal socket suitable for each type of HC relay is indicated by a black dot. 1) Plug-in type sockets, PC board type sockets, and wrapping type sockets are available for HC relays. 2) Certified by UL and CSA 3) A hold-down clip is included in the package. 1) Ordinary terminal sockets and terminal sockets for DIN rail assembly are available. 2) Certified by UL/C-UL 3) A hold-down clip is included in the package. The fixing method is the same as for HC sockets, ordinary HC terminal sockets and HL sockets. The fixing method is the same as for sockets. HC/HL-LEAF-SPRING-MK The fixing method is the same as for the HC DIN rail terminal sockets and the HL DIN rail terminal sockets. Ordinary terminal socket HC/HL-LEAF-SPRING-MK Note: Not compatible with HJ relays. Please use the HJ relay dedicated socket. DIN rail Terminal sockets HC/HL-LEAF-SPRING-K Note: Not compatible with HJ relays. Please use the HJ relay dedicated terminal socket. SELECTOR CHART 1. Sockets Applicable HC relay (Plug-in type) Type No. of pole Product name Part No. Standard type/With diode type (for DC) 1 Form C 2 Form C 3 Form C 4 Form C HC1-socket HC1-SS-K 2-pole HC2-socket HC2-SS-K 3-pole HC3-socket HC3-SS-K 1/2/4-pole (common) HC4-socket HC4-SS-K 1-pole HC1-socket for PC board HC1-PS-K 2-pole HC2-socket for PC board HC2-PS-K 3-pole HC3-socket for PC board HC3-PS-K 1/2/4-pole (common) HC4-socket for PC board HC4-PS-K HC4-wrapping socket HC4-WS-K HC4-wrapping socket (spring) HC4-WS PC board Wrapping 4 Form C 4 Form C 1 Form C 2 Form C 4 Form C 2 Form C (twin) (twin) 1-pole Plug-in 1/2/4-pole (common) Keep relay Amber type Standard packing: Carton: 20 pcs.; Case: 200 pcs. Notes: 1. Use the hold-down clip that is shipped with the socket. (The hold-down clip for HC relay with CR circuit is included in the package.) 2. Certified by UL and CSA (except for wrapping socket). 3. Not compatible with HJ relays. 2. Terminal sockets ( Sockets marked are discontinued as of March 31, 2013.) Applicable HC relay (Plug-in type) Type No. of pole Item Part No. Standard packing Carton 2-pole For DIN rail 2-pole 3-pole 1/2/4-pole (common) HC2-slim type DIN terminal socket HC2-DIN HC3-DIN HC2-SFD-K 10 pcs. 100 pcs. HC3-SFD-K 5 pcs. 50 pcs. HC4-TSF-K 20 pcs. 200 pcs. 2-pole HC2-terminal socket HC2-SF-K 3-pole HC3-high terminal socket HC3-HSF-K 5 pcs. 50 pcs. HC4-HSF-K 5 pcs. 50 pcs. 1/2/4-pole (common) HC-high terminal socket 1 Form C 2 Form C 3 Form C 4 Form C HC2-SFD-S 20 pcs. 100 pcs. HC4-DIN high terminal socket HC4-SFD-K 10 pcs. 100 pcs. 1/2/4-pole (common) HC vertical terminal socket For general Case Standard type/With diode type (for DC) Keep relay Amber type 4 Form C 4 Form C 1 Form C 2 Form C 4 Form C 2 Form C (twin) (twin) 10 pcs. 100 pcs. Notes: 1. Use the hold-down clip that is shipped with the socket. (The hold-down clip for HC relay with CR circuit is included in the package.) 2. Certified by UL/C-UL (except for HC4-TSF-K). 3. In order to prevent breakage and disfiguring, the screw tightening torque for the terminal socket should be within the range of 0.49 to 0.69 N*m {5 to 7kgf*cm}. 4. Not compatible with HJ relays. 20 ds_61C04_en_hc: 220512D HC DIMENSIONS (mm inch) 1. Plug-in type sockets HC1-Socket (HC1-SS-K) HC2-Socket (HC2-SS-K) External dimensions External dimensions 4.45 4.45 .175 .175 4.45 .175 1 5 2 6 3 4 7 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 4.06 .160 6.35 .250 6.35 .250 4.45 4.45 .175 .175 4.45 .175 1 5 2 6 3 4 7 8 9 10 11 12 7.06 .278 13 14 4.06 .160 6.35 .250 6.35 .250 29.4 1.157 25.2 .992 1.27 .050 1.27 .050 25.5 1.004 2.3 .091 25.5 1.004 2.3 .091 16.55 .652 16.55 .652 7.65 .301 General tolerance: 0.3 .012 21.2 .835 HC4-Socket (HC4-SS-K) External dimensions 25.5 1.004 13.35 .526 7 13 2 5 8 3 6 9 14 29.4 1.157 25.2 .992 21.2 .835 7.65 .301 General tolerance: 0.3 .012 HC3-Socket (HC3-SS-K) 1 4 7.06 .278 29.4 29.4 External dimensions 4.45 4.45 .175 .175 4.45 .175 4.06 .160 9.14 .360 10.41 .410 16.76 .660 1 5 2 6 3 4 7 8 9 10 11 12 13 14 4.06 .160 6.35 .250 6.35 .250 29.4 1.157 25.2 .992 7.06 .278 1.27 .050 2.3 .091 16.55 .652 General tolerance: 0.3 .012 21.2 .835 25.5 1.004 2.3 .091 16.55 .652 7.65 .301 General tolerance: 0.3 .012 Mounting hole diagram 7.65 .301 21.2 .835 With a relay mounted (HC2-SS-K) Side-by-side installation 25.8 1.016 8.9 .350 25.8 1.016 21.6 .850 5.9 .232 Hold-down clip is packaged with the socket. 21.6 .850 General tolerance: 0.2 .008 Notes: 1. Applicable chassis board thickness is 1.0 to 2.0 mm. 2. Installation is easy by inserting the socket from the top into the holes and by depressing the two down arrows on the retention fitting from the front. ds_61C04_en_hc: 220512D 21 HC 2. PC board type sockets HC1- PC board type socket (HC1-PS-K) HC2- PC board type socket (HC2-PS-K) External dimensions 4.45 4.45 .175 .175 4.45 .175 4.06 .160 1 5 2 6 3 7 4 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 External dimensions 6.35 .250 6.35 .250 1 5 2 6 3 7 4 8 9 10 11 12 7.06 .278 13 14 29.4 1.157 25.2 .992 6.35 .250 6.35 .250 21.2 .835 HC4- PC board type socket (HC4-PS-K) External dimensions 1 4 2 5 3 6 7 8 9 13 14 29.4 1.157 25.2 .992 External dimensions 4.06 .160 9.14 .360 4.45 4.45 .175 .175 4.45 .175 4.06 .160 1 5 10.41 .410 16.76 .660 29.4 1.157 3.95 .156 General tolerance: 0.3 .012 HC3- PC board type socket (HC3-PS-K) 13.35 .526 21.2 .835 2 .079 13.15 .518 3.95 .156 General tolerance: 0.3 .012 7.06 .278 1.27 .050 1.2 .047 2 .079 13.15 .518 13.35 .526 4.06 .160 2 6 3 7 4 8 9 10 11 12 13 14 29.4 1.157 25.2 .992 6.35 .250 6.35 .250 7.06 .278 1.27 .050 21.2 .835 21.2 .835 2 .079 13.15 .518 General tolerance: 0.3 .012 3.95 .156 General tolerance: 0.3 .012 PC board pattern (Bottom view) With a relay mounted Side-by-side installation 16.8 .661 17.95 .707 Hold-down clip is packaged with the socket. 1 Form C 2 Form C 3 Form C 4 Form C 16.8 .661 13.35 .526 9.85 .388 13.35 .526 2 dia. hole .079 dia. General tolerance: 0.1 .004 22 ds_61C04_en_hc: 220512D HC 3. Wrapping type sockets Standard wrapping type sockets (HC4-WS-K) External dimensions Hold-down clip (Hold-down clip is packaged with the socket) 25.5 1.004 13.35 .526 4.45 .175 1.00.1 .039.004 4.06 .160 9.14 10.41 .360 .410 16.76 .660 25.2 .992 29.4 1.157 12.4 .488 34.4 1.354 Terminal cross section 10.1 .039.004 10.05 .039.002 1.00.1 .039.004 21.2 .835 General tolerance: 0.3 .012 Note: The external and mounting dimensions are the same for 1-pole (HC1-WS-K), 2-pole (HC2-WS-K), and 3-pole (HC3-WS-K) types. Only the number of terminals varies. Wrapping type sockets with hold-down clip (HC4-WS) External dimensions Terminal cross section 10.1 .039.004 1 .039 10.05 .039.002 23 .906 39.3 1.547 22.0 .866 25.5 1.004 21.2 .835 1 .039 1 2 3 4 5 6 7 8 9 10 11 12 13 5 .197 25.2 .992 29.4 1.157 14 General tolerance: 0.7 .028 73.7 2.902 Mounting hole diagram Side-by-side installation 25.8 1.016 8.9 .350 25.8 1.016 21.6 .850 5.9 .232 21.6 .850 General tolerance: 0.2 .008 Notes: 1. Applicable chassis board thickness is 1.0 to 2.0 mm. 2. Installation is easy by inserting the socket from the top into the holes and by depressing the two down arrows on the retention fitting from the front. ds_61C04_en_hc: 220512D 23 HC 4. DIN rail Terminal sockets ( Sockets marked are discontinued as of March 31, 2013.) HC2-Slim type DIN rail terminal sockets (HC2-SFD-S) External dimensions 150.6 .591.024 13.350.2 .526.008 M3 screw M.118 screw Schematic 4 200.6 .787.024 1 8 N.C. 5 N.O. 4.10.2 .161.008 571 2.244.039 80.2 .315.008 6.30.2 .248.008 6.40.2 .252.008 35.40.5 1.394.020 671 2.638.039 20.15 .079.006 6.20.3 .244.012 COM 12 9 Coil 6 .236 220.6 .866.024 14 60.3 .236.012 4.20.3 .165.012 28.50.6 1.122.024 13 General tolerance: 0.5 .020 HC2-high DIN rail terminal socket (HC2-SFD-K) External dimensions 13.350.2 .526.008 260.6 1.024.024 M3 screw M.118 screw Schematic 4 1 N.C. 21.10.6 .831.024 5 N.O. 8 4.10.2 .161.008 4.20.3 .165.012 6.30.2 .248.008 6.40.2 .252.008 671 2.638.039 20.15 .079.006 COM 6 .236 12 9 14 13 Coil 300.6 1.181.024 General tolerance: 0.5 .020 HC3-high DIN rail terminal socket (HC3-SFD-K) External dimensions 260.6 1.024.024 M3 screw M.118 screw Schematic 21.10.6 .831.024 3 2 5 4 1 N.C. 6 N.O. 4.060.2 .160.008 4.20.3 .165.012 6.350.2 .250.008 6.350.2 .250.008 1.270.15 .050.006 671 2.638.039 7 COM 9 6.2 .244 8 Coil 14 300.6 1.181.024 13 General tolerance: 0.5 .020 HC4-high DIN rail terminal socket (HC4-SFD-K) External dimensions 4.450.2 .175.008 260.6 1.024.024 13.350.2 .526.008 4.10.2 .161.008 M3 screw M.118 screw Schematic 4 3 2 1 8 7 6 5 N.C. 21.10.6 .831.024 N.O. 4.20.3 .165.012 6.30.2 .248.008 6.40.2 .252.008 671 2.638.039 20.15 .079.006 COM 12 11 10 9 Coil 14 6 .236 24 300.6 1.181.024 13 General tolerance: 0.5 .020 ds_61C04_en_hc: 220512D HC HC vertical type terminal socket (HC4-TSF-K) External dimensions 2-4.2x5 over hole 2-.165x.197 220.6 .866.024 M3 screw M.118 screw Mounting hole diagram HC2-Slim type 28.60.6 1.126.024 3 2 1 8 7 6 5 12 11 10 9 4 14 13 671 2.638.039 591 2.323.039 6.2 .244 Schematic 300.6 1.181.024 General tolerance: 0.5 .020 With a relay mounted (HC4-SFD-K) HC2, HC3 and HC4 HC vertical type Panel hole dimensions for side-by-side mounting Panel hole dimensions for side-by-side mounting General tolerance: 0.1 .004 Hold-down clip is packaged with the terminal socket. 5. Ordinary terminal sockets HC2-terminal socket (HC2-SF-K for HC2) External dimensions 2-4.2x5 over hole 2-.165x.197 6.2 12 .244 .472 Schematic 1 5 9 13 4 8 12 14 17.5 .689 40 1.575 M3 screw M.118 screw 5 .197 15 .591 30 1.181 General tolerance: 0.5 .020 HC3-high terminal socket (HC3-HSF-K) suitable for both HC2 and HC3 External dimensions Schematic 2-4.2x9 over hole 2-.165x.354 22.5 .886 1 53.5 2.106 M3 screw M.118 screw 4 7 13 28.6 1.126 67 2.638 6.2 .244 30 1.181 9 .354 3 6 9 2 5 8 14 8 16 .315 .630 27.8 1.094 Screw hole dimensions General tolerance: 0.5 .020 ds_61C04_en_hc: 220512D 25 HC HC4-high terminal socket (HC4-HSF-K) suitable for HC 1, 2 and 4 External dimensions 2-4.2x9 over hole 2-.165x.354 22.5 .886 53.5 2.106 M3 screw M.118 screw Schematic 28.6 1.126 1 2 6 10 5 9 13 67 2.638 6.2 .244 30 1.181 9 .354 8 16 .315 .630 27.8 1.094 Screw hole dimensions 4 8 12 3 7 11 14 General tolerance: 0.5 .020 Mounting hole diagram HC2-SF-K 12 23 12 .472 .906 .472 2-M3.5 screw hole (or 4.20.1 dia. hole) 2-M.138 screw hole (or .165.004 dia. hole) With a relay mounted (HC2-SF-K) HC3-HSF-K and HC4-HSF-K 12.5 .492 22.5 .886 22.5 .886 53.5 2.106 67 2.638 40 1.575 30 1.181 30 1.181 5 .197 Panel hole dimensions for side-by-side mounting 26 30 1.181 30 5 1.181 .197 Panel hole dimensions for side-by-side mounting 2-M3.5 screw hole (or 4.20.1 dia. hole) 2-M.138 screw hole (or .165.004 dia. hole) Hold-down clip is packaged with the terminal socket. General tolerance: 0.1 .004 ds_61C04_en_hc: 220512D