Model RM Rod End In-line Tension Load Cell DESCRIPTION Model RM, with male threads, is a high output rod end load cell The optional high output signal offers resistance to electrical designed to be mounted inline to the load axis to measure ten- noise as well as additional signal resolution. Additional options sion. The outputs for these load cells are 5 Vdc or 10 Vdc, or include an internal buffered shunt calibration circuit for ease of 4 mA to 20 mA (two wire) all calibrated in tension. The mount- setup with an associated indicator, and a variety of thread selec- ing thread configurations and the all welded stainless steel tions, including metric sizes. construction make these tension load cells ideal for a variety of rugged field applications as well as in the laboratory. FEATURES * 2000 lb to 200000 lb range * Male/male threads * Stainless steel, all-welded construction * 0 Vdc to 5 Vdc or 4 mA to 20 mA outputs * Up to 0.15 % linearity * CE approved10 Model RM PERFORMANCE SPECIFICATIONS MECHANICAL SPECIFICATIONS Characteristic Measure Characteristic Measure Load ranges11 2000 lb to 200000 lb1 Maximum allowable load 150 % FS1 Linearity 100 lb to 1000 lb 0.2 % full scale Weight See table Linearity 2000 lb to 50000 lb Material Stainless steel 0.15 % full scale Deflection full scale See table Linearity 75000 lb to 20000 lb Natural frequency See table 0.2 % full scale Hysteresis 100 lb to 1000 lb 0.2 % full scale Hysteresis 2000 lb to 50000 lb 0.15 % full scale Hysteresis 75000 lb to 20000 lb 0.2 % full scale Non-repeatability 0.05 % full scale Output (tolerance) 2 mV/V Operation Tension Resolution Infinite ENVIRONMENTAL SPECIFICATIONS Characteristic Measure Temperature, operating -54 C to 121 C [-65 F to 250 F] Temperature, compensated 15 C to 71 C [60 F to 160 F] Temperature effect, zero 0.005 % full scale/F Temperature effect, span 0.005 % full scale/F ELECTRICAL SPECIFICATIONS Characteristic Measure Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 15 Vdc or Vac Insulation resistance 5000 mOhm @ 50 Vdc Bridge resistance (tolerance) 350 ohm Zero balance (tolerance) 1% full scale Shunt calibration data RANGE CODES Range Code Available ranges Range Code Available ranges DL 2000 lb EL 20000 lb DN 3000 lb EN 30000 lb DP 4000 lb EP 50000 lb DR 5000 lb ER 75000 lb DT 75000 lb ET 100000 lb DV 10000 lb FJ 150000 lb EJ 15000 lb FL 200000 lb WIRING CODES Connector Unamplified (Std.) A (+) excitation B (+) excitation C (-) excitation D (-) excitation E (-) output F (+) output DEFLECTIONS AND RINGING FREQUENCIES Capacity (lb) Deflection at full scale mm [in] Ringing frequency (Hz) Weight kg [lb] 2000 0,076 [0.003] 5000 0,45 [1.0] 3000 0,076 [0.003] 5000 0,45 [1.0] 4000 0,076 [0.003] 5100 0,45 [1.0] Included 5000 0,076 [0.003] 5200 0,45 [1.0] Electrical termination (std) 2000 lb to 50000 lb PTIH-10-6P or equivalent (hermetic stainless) 7500 0,102 [0.004] 7500 0,68 [1.5] Electrical termination (std) 75000 lb to 200000 lb MS3102E-14S-6P or equivalent 10000 0,102 [0.004] 7600 0,68 [1.5] 15000 0,127 [0.005] 8000 0,68 [1.5] Mating connector (not included) 2000 lb to 50000 lb PT06A-10-6S or equivalent (AA111) 20000 0,127 [0.005] 9800 0,68 [1.5] 30000 0,127 [0.005] 8000 1,90 [4.2] Mating connector (not included) 75000 lb to 200000 lb MS3106A-14S-6S or equivalent (AA121) 50000 0,127 [0.005] 8200 1,90 [4.2] 75000 to 100000 0,152 [0.006] 5000 7,34 [16.5] 150000 to 200000 0,178 [0.007] 4200 16,01 [35.3] 2 Honeywell * Sensing and Control Rod End In-Line Tension Load Cell INTERNAL AMPLIFIERS Amplifier specifications Voltage output: Option 2b Voltage output: Option 2c Voltage output: Option 2t Current threewire: Option 2j Current twowire: Option 2k Intrinsically safe amp: Option 2n (2N)*** Output signal 5 V 0 V to 5 V or 5 V @ 45 mA 0 V to 10 V or 10 V @ 45 mA 4 mA to 20 mA 4 mA to 20 mA 4 mA to 20 mA Input power (voltage) 15 V or 26 Vdc to 32 Vdc 18 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 15 Vdc to 40 Vdc 9 Vdc to 28 Vdc Input power (current) 45 mA 40 mA 40 mA 65 mA 4 mA to 28 mA 4 mA to 24 mA Freq. resp (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz Power supply rej. 60 db 60 db 60 db 60 db 60 db 60 db Operating temp. -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Reverse voltage protection Yes Yes Yes Yes Yes Yes Short cir. protection Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std)5 A (+) Supply B Output common C Supply return D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B Output common** C Supply return ** D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B Output common** C Supply return** D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B Output common** C Supply return** D (+) Output E Shunt cal 1 F Shunt cal 2 A (+) Supply B No connection C No connection D (+) Output E Case ground F No connection A (+) Supply B No connection C No connection D (+) Output E Case ground F No connection Wiring code: cable5,6,7 R (+) Supply Bl Output common G Supply return W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl Output common* G Supply return* W (+) Output B Shunt cal 1 Br Shunt cal 2 R (+) Supply Bl (+) Output W Case ground R (+) Supply Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See our Web site for the most up-to-date information regarding intrinsically safe approvals, ref. #008-0547-00. Honeywell * Sensing and Control 3 Model RM OPTION CODES Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http:// sensing.honeywell.com/TMsensor-ship for updated listings. Load ranges 2K, 3K, 4K, 5K, 7.5K, 10K, 15K, 20K, 30K, 50K, 75K, 100K, 150K, 200K Temperature compensation 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 1d. -20 F to 130 F 1e. -20 F to 200 F 1f. 70 F to 250 F 1g. 70 F to 325 F8 1h. 70 F to 400 F8 1i. -65 F to 250 F8 1j. 0 C to 50 C 1k. -20 C to 85 C 1m. -25 C to 110 C Internal amplifiers 2u. Unamplified, mV/V output 2b. 4 wire, 5 Vdc output 2c. 0 Vdc to 5 Vdc 2j. 4 mA to 20 mA (three-wire) output 2k. 4 mA to 20 mA (two-wire)12 2n (2N) 4 mA to 20 mA (two-wire) intrinsically safe12 2t. 0 Vdc to 10 Vdc output Internal amp enhancements 3a. Input/output isolation7 3d. Remote buffered shunt calibration Electrical termination 6a. Bendix PTIH-10-6P (or equivalent) 6-pin, (max. 250 F) (ranges 50000 lb and below) 6b. MS connector MS3102E-14S-6P (mates with MS3106E14S-6), (max. 160 F) (ranges above 50000 lb)6 6e. Integral cable: Teflon 6f. Integral cable: PVC Shunt calibration 8a. Precision internal resistor8 Bridge type 11a. Square bridge8 11b. Symmetrical bridge8 11c. Square and symmetrical bridge8 31a. Dual bridge Bridge resistance 12b. 5000 ohm (foil) (max. 250 F) Zero and span adjustment 14a. No access to zero and span adjustment Electrical connector orientation 15a. Horizontal electrical exit port orientation 15b. Vertical electrical exit port orientation 15c. Radial electrical exit port orientation 15d. Connector on end of cable Shock and vibration 44a. Shock and vibration resistance Interfaces 53e. Signature calibration8 53t. TEDS IEEE 1451.4 module9 4 Honeywell * Sensing and Control 6g. Integral cable: Neoprene 6h. Integral cable: Silicone 6i. Integral underwater cable 6j. 1/2-14 conduit fitting with 5 ft of 4 conductor PVC cable 6q. Integral cable: Polyurethane 6v. Phoenix connector on end of cable Rod End In-Line Tension Load Cell MOUNTING DIMENSIONS Unamplified only Amplified only Order code (Unamp/Amp) D mm [in] L1 mm [in] A mm [in] B mm [in] L2 mm [in] E mm [in] F mm [in] AL413/AL613 38,1 [1.50] 66,4 [2.60] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL415/AL615 44,45 [1.75] 66,4 [2.60] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] AL417/AL617 63,5 [2.50] 77,47 [3.05] 19,05 [0.75] 20,82 [0.82] see below 49,53 [1.95] 38,1 [1.50] THREAD SIZES AND OPTION CODES 13a 13b 13c 13d 13e Range (lb) 1/2-20 UNF 3/4-16 UNF 7/8-14 UNF 1-14 UNF 1 1/2-12 UNF 2000 to 5000 AL413 AL413 AL413 AL415 AL415 AL415 AL417 AL415 AL415 AL417 7500 to 15000 20000 TYPICAL SYSTEM DIAGRAM 30000 to 50000 L2 mm [in] AL417 24,13 [0.95] 24,13 [0.95] 24,13 [0.95] 31,75 [1.25] 38,1 [1.50] NON-STANDARD RANGES - ORDER CODE AL411 Range (lb) Thread type D mm [in] L1 mm [in] L2 mm [in] 75000 to 100000 2 1/2-12 UNF 88,9 [3.50] 101,6 [4.00] 76,2 [3.00] 150000 to 200000 3 1/2-8 UNF 114,3 [4.50] 127 [5.00] 101,6 [4.00] Honeywell * Sensing and Control 5 Model RM Rod End In-Line Tension Load Cell NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Allowable maximum loads - maximum load to be applied without damage.2 Without damage - loading to this level will not cause excessive zero shift or performance degradation. The user must consider fatigue life for long term use and structural integrity. All structurally critical applications (overhead loading, etc.) should always be designed with safety redundant load paths. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50 % (unamplified units), 75 % (4 mA to 20 mA three-wire units) or 80 % (voltage amplified units) of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier option 2a, 2b, 2c, 2t and 2j. O=Orange; Y=Yellow; B=Blue; Bl=Black; R=Red; Br=Brown; W=White; G=Green. Color specifying cable and number or letter specifying connector. No mating connector necessary for cable option. Cannot use with options 1c, 1e, 1f, 1g, 1h, or 1i. Only available with option 2b or 2c. Not available with amplified option. Consult factory for TEDS availability with amplified models. Termination dependent; consult factory. This unit calibrated to Imperial (non-Metric) units. 5000 ohm bridge required. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING PERSONAL INJURY * DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. Find out more WARNING Honeywell serves its customers MISUSE OF DOCUMENTATION through a worldwide network of * The information presented in this datasheet is for reference only. DO NOT USE this document as product installation information. * Complete installation, operation and maintenance information is provided in the instructions supplied with each product. sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell's Failure to comply with these instructions could result in death or serious injury. test and measurement products, call +1-614-850-5000, visit www.honeywell.com/sensotec, or e-mail inquiries to info.tm@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 008654-2-EN IL50 GLO January 2010 Copyright (c) 2010 Honeywell International Inc. All rights reserved.