J-7 Visit www.GemsSensors.com for most current information.
SOLENOID VALVES
ø.73
1.61
0.250
#6-32 UNC-2B x
0.22 MIN. FULL TH’D
(2) PLC’S
0.500
0.17
#24 AWG PVC LEADS x 12˝
STOP PORT
(2-WAY N.O. & 3-WAY)
#10-32 UNF-2B x
0.18 MIN. FULL TH’D
0.68
FLATS
(OVERSEAT)
(UNDERSEAT)
BODY PORTS
#10-32 UNF-2B x
0.18 MIN. FULL TH’D
(2) PLC’S
ø.73
Dimensions
Threaded Port Body Manifold Mount Body
Example:
E2010-W24-1-V-VO-24VDC-OC
E-Series 2-Way N.C. solenoid valve, with 24˝ lead-wires from an encapsulated coil,
nickel-plated brass body, Viton® plunger seal, Viton® o-ring, #10-32 straight thread ports,
operating at 24 VDC, and is cleaned for oxygen use.
E & EH Series – Subminiature Gas
MOPD: 175 PSI
CV Range: 0.018 to 0.070
0.65 Watts or 2 Watts
A 2- or 3-way sub-miniature solenoid valve that delivers faster response times—
and higher flow rates, the E & EH Series is specifically engineered for air and
dry gas applications. A nickel-plated body and coil housing construction produces
a highly durable, corrosion resistant valve. With a wattage range of 0.65–2 the E &
EH Series provides versatility for power conserving, high pressure, and high flow
applications.
Typical Applications
•MedicalandRespiratoryHealthcare
•PrintingMachineryandSortingEquipment
•AutomatedPackagingEquipment
•AirMonitoringSystems
E2010 - W24-1 - V - VO - 24VDC - OC
12 5
478
3 6
Primary
Prefix Coil
Construction
O-Ring
Material
Plunger
Seal
Material
Voltage
Additional
Options
Body
Material*
Body Port
Configuration*
How To Order
Use the Bold characters from the choices listed on the following page to
construct a product code.
* Blank entry indicates a "Standard" selection
(#10-32 straight thread ports, in this case).
0.165 ±0.025
1.53
O-RINGS (OVERSEAT)
#10-32 UNF-2A
MOUNTING STUD
0.15
Ø.125 SPANNER HOLE
(3) PLC'S EQUALLY SPACED
Ø.73
(UNDERSEAT)
(OVERSEAT)
(Ø.089)
R.220
32 RMS
OVER Ø.75
(UNDERSEAT)
#10-32 UNF-2B x
0.25 MIN. FULL TH'D
MANIFOLD
MATING DIMENSIONS
J-8
Visit www.GemsSensors.com for most current information.
SOLENOID VALVES
Power
Rating
Orifice MOPD
(psig)
CV1
Primary
Prefix
Body Stop Body Stop
2-WAY
N.C.
0.65W
1/32 125 0.018 E2010
3/64 70 0.023 E2011
1/16 40 0.036 E2012
5/64 20 0.070 E2013
2W
1/32 175 0.018 EH2010
3/64 150 0.023 EH2011
1/16 100 0.036 EH2012
5/64 50 0.070 EH2013
2-WAY
N.O.
0.65W
1/32 125 0.018 E2210
3/64 70 0.023 E2211
1/16 40 0.032 E2212
2W
1/32 175 0.018 EH2210
3/64 150 0.023 EH2211
1/16 100 0.032 EH2212
3-WAY
N.C.
Line
Connection
0.65W
1/32 1/32 125 0.018 0.018 E3110
3/64 3/64 70 0.023 0.023 E3111
1/16 1/16 40 0.036 0.032 E3112
2W
1/32 1/32 175 0.018 0.018 EH3110
3/64 3/64 150 0.023 0.023 EH3111
1/16 1/16 100 0.036 0.032 EH3112
3-WAY
N.O.
0.65W
1/32 1/32 125 0.018 0.018 E3210
3/64 3/64 70 0.023 0.023 E3211
1/16 1/16 40 0.036 0.032 E3212
2W
1/32 1/32 175 0.018 0.018 EH3210
3/64 3/64 150 0.023 0.023 EH3211
1/16 1/16 100 0.036 0.032 EH3212
3-WAY
Multi
Purpose
0.65W
1/32 1/32 80 0.018 0.018 E3310
3/64 3/64 40 0.023 0.023 E3311
1/16 1/16 20 0.036 0.032 E3312
2W
1/32 1/32 150 0.018 0.018 EH3310
3/64 3/64 100 0.023 0.023 EH3311
1/16 1/16 50 0.036 0.032 EH3312
3-WAY
Directional
Control
0.65W
1/32 1/32 135 0.018 0.018 E3410
3/64 3/64 80 0.023 0.023 E3411
1/16 1/16 45 0.036 0.032 E3412
2W
1/32 1/32 190 0.018 0.018 EH3410
3/64 3/64 165 0.023 0.023 EH3411
1/16 1/16 80 0.036 0.032 EH3412
* Standard selection; will be used unless otherwise specified.
Standard selections are not referenced in final part number.
Gems specializes in the design and manufacturing of custom
solenoid valves and fluidic systems. If you don’t see what you’re
lookingfor,orhaveaquestion,contactusat800-378-1600or
info@gemssensors.com.
GENERAL PURPOSE
2 Coil Construction
(blank) = Tape-wrapped, Class-B, with lead-wires (12˝ long)*
W__ = Lead-wires, non-standard length (specify in inches)
1 = Encapsulated coil
5 = Encapsulated coil with 0.110 spade terminals
10 = Rectified coil for AC voltage (2 watt only)
3 Body Material
(blank) = Nickel-plated brass*
4 Plunger Seal Material
(blank) = Nitrile*
V = Viton®
E = EPR
MQ = Silicone
5 O-Ring Material
(blank) = Nitrile*
VO = Viton®
EO = EPR
MQO = Silicone
6 Body Port Configuration
(blank) = #10-32 straight thread ports*
BM = M5 x 0.8 ports
MM = Manifold mount with #10-32 threaded stud
MM2 = Manifold mount with M5 x 0.8 threaded stud
BO = Bottom under-seat port (max orifice = 1/16")
7 Voltage
___VDC = DC (specify voltage)
___VAC = AC rectified 2-watt only (specify voltage)
8 Additional Options
OC = Cleaned for oxygen use
QO = Quiet operation (2-way N.C.)
VAC = Vacuum application (0 to 29.5˝ Hg)
1
Part Prefix Table
Teflon® o-ring not suitable for manifold mount.