POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer Special product features M E MO ' END RD S AP N SIE T T R TR ING R E T AN SA RA A YE R WA Memory capacity of 2GB of trend data storage: up to 50 screen shots, 300 captured transients/inrush and 10,000 alarm events RECO 3 TY 2 GB PowerPad(R) Model 8335 RY '' RRAN (upon registering) FET Y TIN G Four voltage and four current inputs Specifications MODEL electrical 8335 Sampling Frequency Data Storage 256 samples/cycle 2GB SD Card for trend recording; Additional separate 12.5MB partitioned for snapshots, transients, Inrush & alarms Phase-to-Phase: 2000V Phase-to-Neutral: 1000V Voltage Ratio: up to 500kV MN Clamp: 0 to 6A/120A or 0 to 240A SR Clamp: 0 to 1200A MR Clamp: 0 to 1000Aac, 0 to 1400Adc MiniFlex(R): 10 to 1000A AmpFlex(R): 10 to 6500A(1) Current Ratio: 10mA to 50kA 40 to 69Hz kW, kVAR, kVA, PF, DPF, kWh, kVARh, kVAh, K-Factor, Flicker 1st to 50th, Direction, Sequence 9.6V NiMH rechargeable battery pack (included) External AC supply: 110/230VAC 10% (50/60Hz) 8 hours with display on; 35 hours with display off (record mode) Voltage (TRMS) Current (TRMS) Frequency (Hz) Other Measurements Harmonics Power Source Battery Life Mechanical Communication Port Display Dimensions Weight Safety Rating Optically isolated USB 1/4 VGA (320 x 240) color LCD display with adjustable brightness & contrast 9.8 x 7.8 x 2.6" (250 x 200 x 67mm) 4.3 lbs (1.95kg) EN 61010, 600V CAT IV(2), 1000V CAT III, Pollution Degree 2 Crest factor at 6500 = 1 (1) product includes 8335 Kit Five 10 ft black voltage leads, five black alligator clips, twelve color-coded rings, USB cable, NiMH battery, 110/240V power adapter with US power cord, DataView(R) software, large classic tool bag, soft carrying pouch and user manual. (See page 25 for optional current probes) 24 www.aemc.com When used with SR193 or AmpFlex(R) probes. 600V CAT III with MN193 or MR193 probes. (2) FEATURES *Measurement of TRMS voltages up to 1000Vrms AC/DC for two-, three-, four- or five-wire systems *Measurement of TRMS currents up to 6500Arms (sensor dependent) *Color-coded input ID markers included *Direct measurement of neutral current & voltage *Frequency measurement (40 to 69Hz systems) *Record and display trend data as fast as once per second for one month for up to 25 variables *Transient detection on all V and I inputs (up to 210) *Selectable PT and CT ratios * Inrush current measurement *Calculation of Crest Factors for V and A *Calculation of the K-Factor for transformers *Calculation of short-term flicker *Calculation of the Three-Phase voltage unbalance * H armonic measurements (referenced to the fundamental or RMS value) for voltage, current or power, up to 50th harmonic *Displays of harmonic sequencing and direction and calculation of overall harmonics *Real-time display of Phasor diagrams including values and phase angles *Monitors the average value of any parameter, calculated for a period from 1 sec to 2 hrs *Measurement of active, reactive and apparent power per phase and their respective sum total *Calculation of power factor, displacement power factor and tangent factor *Recording, time stamping and characterization of disturbance (swells, sags and interruptions, exceedence of power and harmonic thresholds) *2GB internal Trend Recording memory; Alarm, Photo and Transient Inrush memories are separate *Measurement of energy VAh, VARh & Wh *The Max and Min RMS measurements are calculated every half-period *Includes FREE DataView (R) software for data storage, real-time display, analysis and report generation *65s/sample trend recording Technical Assistance (800) 343-1391 C PowerPad(R) Model 8335 Large Color Functional Displays Configuration Transient Mode Power and Energy Mode Phasor Diagram Recording Mode Harmonics Mode Take a look at Model 8335's key features and functionality Catalog No. 2136.20 2136.21 2136.22 2136.23 2136.24 2136.25 2136.26 2136.27 2136.28 2133.73 2140.15 2140.17 2140.19 2140.28 2140.32 2140.33 2140.34 2140.35 2140.36 2140.43 2140.44 2140.45 2140.46 2140.48 Description PowerPad(R) Model 8335 (no probes) PowerPad(R) Model 8335 w/4 MN93-BK (200A) PowerPad(R) Model 8335 w/4 SR193-BK (1200A) PowerPad(R) Model 8335 w/4 24" AmpFlex(R) 193-24-BK (6500A) PowerPad(R) Model 8335 w/4 36" AmpFlex(R) 193-36-BK (6500A) PowerPad(R) Model 8335 w/4 MR193-BK (1000Aac/1400Adc) PowerPad(R) Model 8335 w/4 MN193-BK (5A/100A) PowerPad(R) Model 8335 w/4 MA193-10-BK (1000A) PowerPad(R) Model 8335 w/3 193-24-BK & 1 MN193-BK Extra Large Classic Tool Bag Replacement - Soft Carrying Pouch 5A Adapter Box (special order only) Replacement - Battery 9.6V NiMH AC Current Probe Model MR193-BK (1000Aac/1400Adc) AC Current Probe Model MN93-BK (200A) AC Current Probe Model SR193-BK (1200A) AmpFlex(R) Sensor 24" Model 193-24-BK (6500A) AmpFlex(R) Sensor 36" Model 193-36-BK (6500A) AC Current Probe Model MN193-BK (5A/100A) Replacement - Set of 5, 10 ft (3m) black leads w/5 black alligator clips Lead, 1 10 ft (3m) black lead w/black alligator clip Replacement - Set of 12, Color-coded Input ID Markers Replacement - 5 ft USB Cable One MiniFlex(R) Sensor 10" Model MA193-10-BK (1000A) Technical Assistance (800) 343-1391 www.aemc.com 25 POWER QUALITY ANALYZERS, METERS & LOGGERS DATAVIEW(R) Three-Phase Power Quality Analyzer Software Data Analysis and Reporting Software for Power Quality Meters Configure all functions of the PowerPad (R) * Display and analyze real-time data on your PC *Configure all PowerPad (R)functions and parameters from your PC *Customize views, templates and reports to your exact needs *Create and store a complete library of configurations that can be uploaded to the PowerPad (R) as needed *Zoom in and out and pan through sections of the graph to analyze the data *Download, display and analyze recorded data *Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event logs and stored alarms *Print reports using standard or custom templates you design * Free updates are available on our website www.aemc.com DataView (R) software provides a convenient way to configure and display power quality measurements from your computer. Through the use of clear and easy-to-use tabbed dialog boxes, all PowerPad (R) functions can be configured and tests can be initiated. Results can be displayed in real-time and stored in your PC. Reports may be printed along with the operator's comments and analysis. Technical Assistance (800) 343-1391 www.aemc.com 21