Z+ High Voltage Series 200 to 800W Programmable Power Supplies Features 2U high Built-in USB, RS-232 & RS-485 Interface Optional LAN, GPIB & Isolated Analog Programming Bench or Rack Mount Constant Current or Voltage Modes Five Year Warranty Key Market Segments & Applications Model Selector Voltage Adjust Current Adjust Max Power Ripple 5Hz-1MHz Noise 20MHz BW Ripple 5Hz-1MHz Efficiency % Model Range Z160-1.3-U Z160-2.6-U Z160-4-U Z160-5-U Z320-0.65-U Z320-1.3-U Z320-2-U Z320-2.5-U Z650-0.32-U Z650-0.64-U Z650-1-U Z650-1.25-U 0 - 160 0 - 160 0 - 160 0 - 160 0 - 320 0 - 320 0 - 320 0 - 320 0 - 650 0 - 650 0 - 650 0 - 650 Range (W) (mV) (mV) (mA) (100-200VAC) 0 - 1.3 0 - 2.6 0-4 0-5 0 - 0.65 0 - 1.3 0-2 0 - 2.5 0 - 0.32 0 - 0.64 0-1 0 - 1.25 208 416 640 800 208 416 640 800 208 416 650 812 10 10 10 10 25 25 30 30 60 60 60 60 100 100 100 100 150 150 150 150 250 250 250 250 1.2 1.5 2.0 2.0 0.8 1.0 1.5 1.5 0.5 0.6 1.0 1.0 79 / 81 84 / 86 86.5 / 88.5 86.5 / 88.5 79 / 81 84 / 86 87 / 88.5 86.5 / 89 79 / 81 84 / 86 86.5 / 88.5 87 / 89 Factory Installed Options Option Code IEC320 cable USA plug (Included in model number above) -U Only one of the options below can be included: GPIB Interface* IEEE Voltage Programming Isolated Analog Interface* IS510 Current Programming Isolated Analog Interface* IS420 LAN Interface (Complies with "LXI" Class C) LAN Part Number Example Z160-1.3-LAN-U Accessories Part Number 19" Rack Housing (Accepts four 105mm width units or six 70mm width units) Blanking Panel for 19" Rack (70mm) Blanking Panel for 19" Rack (105mm) Dual/Triple Housing (Accepts two 105mm case units or three 70mm case units) Serial Link Cable (One is included with each power supply) Communication Cable RS485 Communication Cable RS232 North American Line Cord (One included with -U suffix) Z-NL100 Z-BP Z-WBP Z-NL200 Z-RJ45 Z-485-9 Z-232-9 Z-U *Requires wide body (105mm) case style 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 117 Disclaimer: us.tdk-lambda.com/lp/legal.htm Z+ Series Specifications (See brochure on website for full detailed specifications) Model Z160 Z320 Z650 Load Regulation CV 0.01% of rated voltage over 0 - 100% load change Line Regulation CV 0.01% of rated voltage over 0 - 100% input change Recovery Time (1) CV 2ms Temperature Coefficient CV 30ppm/C following 30 minute warm up Temperature Stability CV 0.02% of rated voltage over 8 hours following 30 minute warm up time Warm up Drift (2) CV <0.05% of rated voltage of rated output voltage Up programming response time (10-90% or 90-10% of Vmax) CV 80ms 150ms 150ms Down programming resp time (CV) (10-90% or 90-10% of Vmax) Full load 100ms 150ms 150ms Down programming resp time (CV) (90-10% of Vmax) Zero load 2ms 2.5ms 3ms Load Regulation CC 0.09% of rated current over 0 - 100% Vout change Load Regulation thermal drift CC < 0.05% of rated current over 30 minutes after load change Line Regulation CC 0.02% of rated current over a 85 - 132 or 170 - 265VAC line change Temperature Coefficient CC 100ppm/C of rated current after 30 minute warm up time Temperature Stability CC 0.05% of rated current over 8 hours following 30 minute warm up time Warm up Drift(2) CC <0.1% of rated current Vout & Iout programming & readback resolution Digitally < 0.012% of rated voltage/current Vout & Iout programming & readback accuracy Digitally 0.05% of rated voltage + 0.05% of actual, 0.2% of rated current Voltage & Current Programming Analog By either Voltage (0-5V or 0-10V) or Resistance (0-5k or 0-10k) Voltage & Current Monitoring Analog 0-5V or 0-10V Voltage (user selectable), 1% accuracy Overvoltage Shutdown (user programmable) V 5 - 176 5 - 353 5 - 717 Overtemperature Protection User selectable - latched or non-latching Display - Voltage 4 digits. Accuracy 0.5% of rated voltage or current 1 count Remote On/Off By applied voltage or dry contact relay (user selectable logic) Output Good Open Collector, Low on fail Remote Sense Compensation (per wire) V 5 5 5 Communication Interface RS232, RS485 & USB standard, IEEE488 (GPIB) & LAN optional Series Operation Up to two identical units (with external diodes) Parallel Operation Up to six units in master-slave configuration Input Voltage / Frequency 85-265VAC, 47-63Hz Inrush Current < 25A Hold Up Time (Typical) ms 16ms Power Factor Correction Complies with EN61000-3-2 Class A (0.99 typ) Operating Temperature C 0 - 50C Storage Temperature C -20 to +85C Humidity (non condensing) %RH Operating: 20 - 90%RH, Storage 10 - 95%RH Cooling Internal temperature controlled fan Withstand Voltage I/P to GND 2kVAC, I/P to O/P 3kVAC, O/P to GND 1380VDC 1 min Insulation Resistance >100M at 25C & 70%RH Vibration (non operating) IEC60068-2-64 Shock <20G, half sine, 11ms. IEC60068-2-27 Safety Agency Certifications UL61010-1, EN61010-1, IEC61010 (Designed to meet UL/EN60950-1) Immunity IEC61326 (Designed to meet EN55022 / EN55024) Conducted EMI IEC/EN61326-1 Industrial location B, FCC part 15-B, VCCI-B Radiated EMI IEC/EN61326-1 Industrial location A, FCC part 15-A, VCCI-A Size (H x W x D) (Excluding handles and busbars) mm Standard body 83 x 70 x 350mm; Wide Body 83 x 105 x 350mm Weight kg Standard body 1.9kg; Wide Body 2.4kg Warranty yrs Five Years Notes: (1) Recovery to within 0.5% of rated voltage after a load change of 10-90% (Output current 10-100% of Imax) (2) Over 30 minute warm up time after power on 1-800-526-2324 * www.us.tdk-lambda.com/lp/ For Additional Information, please visit us.tdk-lambda.com/lp/products/zplus-series.htm 118 Revision p1.5: Sept. 2014 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: Z160-1.3-IS510-U Z650-0.32-IEEE-U Z320-0.65-LAN-U Z320-1.3-IS420-U Z320-1.3-LAN-U Z650-0.32-IS420-U Z320-0.65-U Z160-2.6-IS420-U Z320-1.3-U Z320-0.65-IEEE-U Z650-0.64-IS510-U Z650-0.32-IS510-U Z320-1.3IEEE-U Z650-0.32-LAN-U Z320-0.65-IS420-U Z160-1.3-U Z320-2.5-IS510-U Z320-2-U Z160-5-U Z160-5-IS510-U Z320-2-LAN-U Z160-5-IEEE-U Z320-2.5-U Z650-1.25-IS510-U Z320-2.5-IS420-U Z375-2.2-U