Only One Name Means ProTek’Tion™

 




The 422ELC is low capacitance, two-stage transient voltage protector that provides primary and secondary protec-
on against lightning, inducve switching and electrostac discharge (ESD) transient threats. The rst stage diverts
the transient current through the ground terminal return path and the second stage clamps the voltage to a safe level
without interrupon of service.
The 422ELC is designed to protect data lines from dierenal (line-line) and common-mode (line-to-ground) transients.
Terminals 1 & 2 and 3 & 4 for the 422ELC are designed as line pairs. A transient voltage suppressor is connected
across each line pair for dierenal mode protecon. Each line pair is referenced to ground.
This product can also be used on telephone, signal/data lines, security, ming and control interface circuits. For most
applicaons, the product should be located as close as possible to the equipment being protected. A low impedance
grounding system is important to maintain a low voltage clamp between the line-to-ground connecon. Capacitance
over the operang voltage range is important. If capacitance is nonlinear, distoron, loss of data or access to the I/O
port can occur (See Figure 1).

RS-422 Data Lines
Digital Process Control Loop
Long Line Digital Systems
Digital Transmission
Telemetry Systems
Smoke Detector and Fire Alarm Systems
Compable with IEC 61000-4-2 (ESD): Air - 15kV, Contact - 8kV
Compable with IEC 61000-4-4 (EFT): 40A - 5/50ns
Compable with IEC 61000-4-5 (Surge): 95A, 8/20µs, Level 4 (Line-
Gnd) & 48A, Level 4 (Line-Line)
Low Capacitance - 25pF
Designed for EIA Standard RS-422 Data Lines
Permanent Two-Stage 2 Line Pair Protector
Subnanosecond Response Time
Common & Dierenal Mode Protecon
Automac Reset - Does Not Interrupt Service
Eecve Against Lightning, Inducve Switching and ESD

Approximate Weight: 142 grams
Flammability Rang UL 94V-0








Industry
Standard Low
Capacitance TVS
Protector
ProTek Device

Only One Name Means ProTek’Tion™

 




   
Peak Operang Line Voltage VOP ±12 Volts
Operang Line Current IO200 mA
Transient Voltage - 20 kV/Wire
Transient Current - 8/20µs waveform - 10 kA/Wire
Transient Current - 8/20µs waveform - 40 kA/Wire
Operang Temperature TA-55 to 100 °C
Storage Temperature TSTG -55 to 100 °C
Response Time - < 1 ns































422ELC 30.0 30.0 12 1 25
Only One Name Means ProTek’Tion™

 



UNPROTECTED SIDE PROTECTED SIDE
2
1
GND
3
4
2
1
GND
3
4
Earth Ground Earth Ground
(Line Input Terminal)
Data Line from Outside World
(Equipment Terminal)
To Transmit/Receive Circuits
Note: Both ground terminals are common. Use second ground wire
to reduce impedance on long runs to earth ground connecons.

There are ve (5) terminals on the LINE SIDE and ve (5) terminals on the EQUIPMENT SIDE of the 422ELC, 4 data lines and one ground. Both grounds are connected
together internally. A single low impedance ground is sucient. Incoming data lines are cut or disconnected from the equipment to insert the 422ELC product. The
incoming lines are to be connected to the line side terminals as the equipment side lines are connected to the equipment side terminals. The locaon of the product
should be as close to the equipment as possible. The 422ELC series is designed with a short circuit failure mode to give maximum protecon. A fuse, fusible link, or
circuit breaker is recommended for each data/signal line on the input side for those that require an open circuit failure mode.
 A low DC resistance ground may not be a good ground. Lightning contains a broad spectrum of frequencies up to 1 MHz. A low impedance path to ground
at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG stranded wire. For wire lengths over 1.5 meters, there may be some excessive
line to earth potenal under severe thunderstorm condions.
Only One Name Means ProTek’Tion™

 



A
B
C
D
E
F
Mounng Hole
for #8 Screw
Terminal Screw
A
Adhesive Mylar Label
Terminal Strip
#6 Screws
EQUIPMENT
LINE
4 3 GND 2 1
1 2 GND 3 4
WARNING

  
   
A - 95.5 - 3.8
B 82.22 82.98 3.235 3.265
C - 57.2 - 2.25
D - 30.2 - 1.125
E - 15.5 - 0.61
F - 30.2 - 1.19

 
422ELC Logo, Date Code, Terminal Designaons and Part Number
Only One Name Means ProTek’Tion™

 



COPYRIGHT © ProTek Devices 1998 - This literature is subject to all applicable copyright laws and is not for resale in any manner.
SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteriscs described herein without noce.
DESIGN CHANGES: ProTek reserves the right to disconnue product lines without noce and that the nal judgement concerning selecon and specicaons is the buyer’s and that in furnishing engineering
and technical assistance. ProTek assumes no responsibility with respect to the selecon or specicaons of such products. ProTek makes no warranty, representaon or guarantee regarding the suitability of
its products for any parcular purpose, nor does ProTek assume any liability arising out of the applicaon or use of any product or circuit and specically disclaims any and all liability without limitaon special,
consequenal or incidental damages.
LIFE SUPPORT POLICY: ProTek Devices products are not authorized for use in life support systems without wrien consent from the factory.

In business more than 20 years, ProTek Devices™ is a privately-held company located in Tempe, Arizona, that oers a product line of tran-
sient voltage suppressors (TVS); avalanche breakdown diodes; steering diode TVS arrays and other surge suppressor component products.
These TVS devices protect electronic systems from the eects of lightning, electrostac discharge (ESD), nuclear electromagnec pulses
(NEMP), inducve switching and EMI / RFI. ProTek Devices also oers high performance interface and linear products that include analog
switches; mulplexers; LED drivers; audio control ICs; RF and related high frequency products. The analog devices work in a host of con-
sumer; industrial; automove and other applicaons.


2929 South Fair Lane
Tempe, Arizona 85282
USA

General: 602-431-8101
Sales: & Markeng: 602-414-5109
Customer Service: 602-414-5114
Product Technical Support: 602-414-5107

General: 602-431-2288

Sales: sales@protekdevices.com
Customer Service: service@protekdevices.com
Technical Support: support@protekdevices.com

8 Ubi Road 2, #06-19
Zervex
Singapore - 408538
Tel: +65-67488312
Fax: +65-67488313

www.protekdevices.com