134 KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use. 11/14/17
SL1, SL2
surface mount molded current sense resistors
features
• Surface mount type
• Flameproof UL94V0 molded polymer case
• Excellent dimension accuracy, mountability
and shock resistance
• Products with lead-free terminations meet EU RoHS
requirements. EU RoHS regulation is not intended for
Pb-glass contained in electrode, resistor element and glass.
• AEC-Q200 Qualified
ordering information
D: ±0.5%
F: ±1%
J: ±5%
T: Sn ±0.5%, ±1%: 4 digits
±2%, ±5%: 3 digits
All values less than 0.1Ω
(100m) are expressed in mΩ
with “L” as decimal
Ex: 2mΩ= 2L00
0.1Ω: R100; 5mΩ: 5L0
1: 1W
2: 2W
SL TE: 7" embossed plastic
TED: 10" embossed plastic
For further information on
packaging please refer to
Appendix A
SL
Type Power Rating Nominal
Resistance Tolerance
Termination
Material Packaging
1 TE 10L0 FT
dimensions and construction
W
t
L
a
b
cc Molded
Resin Resistive
Element
Electrode
.453±.012
(11.5±0.3) .276±.008
(7.0±0.2) .098±.008
(2.5±0.2) .197±.008
(5.0±0.2) .102±.02
(2.6±0.5)
SL1
(2512)
SL2
(4527)
cbatWL Dimensions inches (mm)
.248±.012
(6.3±0.3) .122±.008
(3.1±0.2) .075±.008
(1.9±0.2) .047±.008
(1.2±0.2)
.067±.008
(1.7±0.2)
.047±.012
(1.2±0.3)
.094±.008
(2.4±0.2)
Size
Code
Derating Curve
% Rated Power
100
80
60
40
20
-60 -40 0 40 60 80 100 180
70
20
Ambient Temperature
(°C)
0120
-20 140 160
-55
% Rated Power
100
80
60
40
20
-60 -40 0 40 60 80 100 18020
Terminal Part Temperature
(°C)
0
120
-20 140
-55 160
90
For resistors operated at an ambient temperature
of 70°C or above, a power rating shall be derated
in accordance with the above derating curve.
For resistors operated at a terminal part temperature of described for each size
or above, a power rating shall be derated in accordance with the derating curve.
Please refer to “Introduction of the derating curve based on the terminal part
temperature” in the beginning of our catalog before use.
current
sense