Ordering Information
Ordering Guide
Nominal Nominal Nominal Output Max.
Input Input Input Output Power Line
Item Ordering Voltage Current Power Power Voltage Range Ripple UL/ETL Location
Number Abbreviation (V) (A) Factor (W) (VDC)* (W) (V) File # Rating
51622 OT17W/24V/UNV* 120 0.19 0.92 21 24.0 0.8-17 ±1.0V E220096 Damp
277 0.10
51512 OT20W/24V/120-240V/SQ 120 0.38 0.5 23 24.0 0.9-20 ±0.2V E258264 Dry
240 0.19
51521 OT30/120/24CORD 120 0.63 0.5 38 24.0 1-30 ±1.5V 3137489 Dry
51598 OT50W/24V/120V/LP 120 0.47 0.99 56 24.0 0.9-50 ±0.2V E248522 Dry
515143 OT75W/24V/UNV 120 0.76 0.99 90 24.0 0.9-75 ±0.2V E258264 Damp
277 0.33
515224 OT96W/24V/UNV 120 0.97 0.9 107 24.0 1-96 ±1.0V E320395 Damp
277 0.39
51626 OT96W/24V/UNV/JBX 120 0.91 0.99 108 24.0 0.8-96 ±1.0V E320395 Wet2
277 0.39 UL Listed
51627 OT240W/3X24V/120-240V/JBX 120 2.39 0.99 285 24.0 0.8-240 ±1.0V E320395 Wet2
240 1.19 UL Listed
*7W is the minimum output power required when operating at the 277V input voltage.
Dimmable Power Supply
Nominal Nominal Nominal Output Output Max.
Input Input Input Voltage Power Line
Item Ordering Voltage Current Power Power Range Range Ripple Dimming Dimming Dimming UL Location
Number Abbreviation (V) (A) Factor (W) (VDC)* (W) (V) Mode Control Range File # Rating
51520 OT96W/24V/UNV/DIM 120 0.97 0.9 107 24.0 1-96 ±1.0V PWM 0-10V DC 10 –100% E320395 Damp
277 0.39
*Output Voltage tolerance ±5%
Notes:
1. All power supplies can be remote mounted up to 32 feet. Although it is possible to exceed the remote mounting distance, the installer and/or end user must take precautions to prevent
and/or test the effects of EMI (electromagnetic interference).
2. Use wiring rated and marked PLTC, CL3R, and “sun resistant”
3. 51514 replaces 51513 (OT75/120/24), which is discontinued
4. 51522 replaces 51510, which is discontinued
OT 240W / 3x24V / 120-240 / JBX
OPTOTRONIC® Output Wattage Output Voltage Input Voltage Junction Box
Minimum and Maximum Ratings
Parameter Power Supply Values
Input Voltage Range (Min/Max) OT20 and OT240 108-254 VAC
OT30 and OT50 108-132 VAC
OT17, OT75 and OT96 108-305 VAC
Input Frequency 50/60Hz
Ambient Temperature Range OT20 and OT50 -20°C through +50°C
OT30, OT96 -20°C through +40°C
OT75 -25°C through +60°C
OT17, OT96JBX and OT240 -30°C through +70°C (2% de-rating per °C from 50°C)
Max. Case Temperature OT30 45°C
OT50 70°C
OT20, OT96 75°C
OT17, OT75, OT96JBX and OT240 90°C
Fixture Description: Type
Project/Job:
SYLVANIA lamp:
SYLVANIA ballast:
Notes:
Specification Data