MHR SERIES Miniature General Purpose AC LVDT SPECIFICATIONS FEATURES Compact size Lightweight core 0.25% linearity (100% stroke) Shock and vibration tolerant Stainless steel case Calibration certificate supplied with each unit APPLICATIONS X, Y, Z stage position feedback Wire-die bonding machines Cylinder position feedback Voice coil testing Materials testing machines Space restricted installations SENSOR SOLUTIONS /// MHR Series Rev. 8 Small size and low mass core High output signal Stroke ranges from 0.005 to 2 inches AC operation from 2kHz to 20kHz Stainless steel housing Imperial or metric threaded core The legendary MHR Series LVDTs provide precision measurements in space restrictive applications. With a diameter of just 3/8 inch [9.5mm], and an extremely lightweight core, the MHR Series is ideal for applications where excessive core weight could influence the motion; with less inertia, accurate measurements at higher displacement speeds are easier to achieve. The lightweight core also reduces mechanical stresses and helps preserve the structural integrity of the core actuation assembly. The high output sensitivity resulting from the close electrical coupling between the coil and core provides ample signal for interfacing with practically all signal conditioners and conditioning circuits. The magnetic stainless steel housing provides electromagnetic and electrostatic shielding. The high temperature operation (200oC) model, MHR-T is available for stroke ranges of 0.025 to 1 inch. A High pressure (vented case) model, MHR-V is also available. The MHR is compatible with the full line of Measurement Specialties LVDT signal conditioners. Like in most of our LVDTs, the MHR windings are vacuum impregnated with a specially formulated, high temperature, flexible resin, and the coil assembly is potted inside its housing with a two-component epoxy. This provides excellent protection against hostile environments such as high humidity, vibration and shock. 07/2017 Page 1 MHR SERIES Miniature General Purpose AC LVDT PERFORMANCE SPECIFICATIONS ELECTRICAL SPECIFICATIONS (common) Input voltage 3 VRMS sine wave Input frequency 2kHz to 20kHz Test frequency 2.5kHz (standard) ELECTRICAL SPECIFICATIONS @ 10kHz (recommended operation) Parameter Stroke range Sensitivity V/V/inch [mV/V/mm] Output at stroke ends mV/V (*) Phase shift Input impedance (PRIMARY) Output impedance (SECONDARY) MHR 005 0.005 [0.13] 8.70 [343] MHR 010 0.010 [0.25] 6.05 [238] MHR 025 0.025 [0.64] 8.10 [319] MHR 050 0.05 [1.27] 3.15 [124] MHR 100 0.10 [2.54] 2.80 [110] MHR 250 0.25 [6.35] 2.07 [81.5] MHR 500 0.5 [12.7] 1.96 [77.2] 43.5 60.5 202.5 157.5 280 517.5 980 MHR 1000 MHR 2000 1 2 [25.4] [50.8] 0.77 0.49 [30.3] [19.3] 770 980 +38 +20 +21 +8 +5 +7 +7 -1 -15 84 165 238 419 400 345 264 155 504 302 300 485 154 200 420 810 450 1780 0.15 0.25 0.25 0.30 0.15 0.25 0.35 0.50 % of FR 0.15 0.25 0.25 0.30 0.20 0.25 0 .50 / / 0.50 / / Non-linearity @ 50% stroke @100% stroke (max) @125% stroke @150% stroke Null voltage (max.) 0.20 0.10 0.25 0.25 0.30 0.35 0.40 0.35 2.5% FRO 1.0% FRO Parameter MHR 005 MHR 010 MHR 025 MHR 050 MHR 100 MHR 250 MHR 500 0.005 [0.13] 0.010 [0.25] 0.025 [0.64] 0.05 [1.27] 0.10 [2.54] 0.25 [6.35] 0.5 [12.7] 1 [25.4] 2 [50.8] 3.19 [126] 3.36 [132] 4.36 [172] 2.55 [100] 2.40 [94] 1.73 [68] 1.60 [63] 0.70 [27] 0.47 [19] 16 33.6 109 127.5 240 432.5 800 700 940 +73 +59 +58 +36 +30 +33 +23 +6 +3 59 78 116 141 135 147 145 100 304 260 192 286 90 125 268 445 370 13620 @ 50% stroke 0.20 0.10 0.15 0.15 0.15 0.15 0.15 0.20 / @100% stroke (max) 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 @125% stroke 0.30 0.35 0.25 0.35 0.25 0.35 0.30 (**) 0 .50 / @150% stroke 0.40 0.35 0.30 0.50 0.30 0.50 (**) 0.75 (**) / / 3% FRO 1.5% FRO 0.15 0.15 0.25 0.25 0.35 0 .30 (**) 0.50 (**) 0.75 (**) 0.5% of FRO ELECTRICAL SPECIFICATIONS @ 2.5kHz (standard calibration) Stroke range Sensitivity V/V/in [mV/V/mm] Output at stroke ends, mV/V (*) Phase shift Input impedance (PRIMARY) Output impedance (SECONDARY) Non-linearity Null voltage (max) MHR 1000 MHR 2000 % of FR 0.5% of FRO (*) Unit for output at stroke ends is millivolt per volt of input voltage (**) Requires special reduced core length SENSOR SOLUTIONS /// MHR Series Rev. 8 07/2017 Page 2 MHR SERIES Miniature General Purpose AC LVDT ENVIRONMENTAL SPECIFICATIONS & MATERIALS Operating temperature -65F to +300F [-55C to 150C] Shock survival 1,000 g (11ms half-sine) Vibration tolerance 20 g up to 2KHz Housing material AISI 400 Series stainless steel Electrical connection Six lead-wires, 32 AWG stranded Copper, PTFE insulated, 1 foot [0.3m] long (longer wires optional) IEC 60529 rating IP61 Notes: All values are nominal unless otherwise noted Electrical specifications are for the test frequency indicated in the table Dimensions are in inch [mm] unless otherwise noted FR: Full Range is the stroke range, end to end; FR=2xS for S stroke range FRO (Full Range Output): Algebraic difference in outputs measured at the ends of the range MECHANICAL SPECIFICATIONS Parameter MHR 005 MHR 010 MHR 025 MHR 050 MHR 100 MHR 250 MHR 500 MHR 1000 MHR 2000 Body length "A" 0.375 [9.5] 0.535 [13.6] 0.660 [16.8] 0.815 [20.7] 0.990 [25.1] 1.850 [47.0] 3.300 [83.82] 5.600 [142.2] 8.000 [203.2] Core length "B" 0.180 [4.6] 0.233 [5.9] 0.400 [10.2] 0.500 [12.7] 0.625 [15.9] 1.125 [28.6] 2.000 [50.8] 3.000 [76.2] 3.00 [76.2] Body weight oz [g] 0.07 [2] 0.11 [3] 0.18 [5] 0.21 [6] 0.21 [6] 0.32 [9] 0.60 [17] 0.92 [26] 1.4 [40] Core weight oz [g] 0.004 [0.1] 0.007 [0.2] 0.016 [0.5] 0.016 [0.5] 0.025 [0.7] 0.032 [0.9] 0.056 [1.6] 0.088 [2.5] 0.088 [2.5] Dimensions are in inch [mm] SENSOR SOLUTIONS /// MHR Series Rev. 8 07/2017 Page 3 MHR SERIES Miniature General Purpose AC LVDT WIRING INFORMATION Connect Blue to Green for differential output ORDERING INFORMATION Description Model 0.005 inch LVDT 0.010 inch LVDT 0.025 inch LVDT 0.05 inch LVDT 0.10 inch LVDT MHR 005 MHR 010 MHR 025 MHR 050 MHR 100 Part Number 02560405-000 02560406-000 02560407-000 02560408-000 02560409-000 Description 0.25 inch LVDT 0.5 inch LVDT 1 inch LVDT 2 inch LVDT Model MHR 250 MHR 500 MHR 1000 MHR 2000 Part Number 02560410-000 02560411-000 02560412-000 02561033-000 OPTIONS XXXXXXXX-002 5.0 kHz calibration 10 kHz calibration Metric threaded core 10 foot long lead-wires XXXXXXXX-003 XXXXXXXX-006 Consult factory XXXXXXXX-040 Note: Add multiple option dash numbers together to determine proper ordering suffix Example: MHR 1000, 1 inch, with 5 kHz calibration and metric threaded core, P/N 02560412-008 ACCESSORIES Core connecting rod, Core connecting rod, Core connecting rod, Core connecting rod, Core connecting rod, Core connecting rod, Mounting block 05282945-006 05282945-012 05282945-024 05282945-036 05282976-006 05282976-012 04560954-000 6 inches long, 1-72 threads 12 inches long, 1-72 threads 24 inches long, 1-72 threads 36 inches long, 1-72 threads 6 inches long, M2x0.4 metric threads 12 inches long, M2x0.4 metric threads SENSOR SOLUTIONS /// MHR Series Rev. 8 07/2017 Page 4 MHR SERIES Miniature General Purpose AC LVDT NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity company Tel: 800-522-6752 Email: customercare.frmt@te.com EUROPE ASIA Measurement Specialties (Europe), Ltd., a TE Connectivity Company Tel: 800-440-5100 Email: customercare.bevx@te.com Measurement Specialties (China) Ltd., a TE Connectivity company Tel: 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity`s obligations shall only be as set forth in TE Connectivity`s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. (c) 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS /// MHR Series Rev. 8 07/2017 Page 5