HS6E Subminiature Interlock Switches with Solenoid
Key features:
• Compact body: 75 × 15 × 75mm
15mm wide, thinnest solenoid interlock switch in the world
• Reversible mounting and angled cable allow four actuator insertion directions
• Energy saving: 24V DC, 110mA (solenoid: 100mA, LED: 10mA)
• Manual unlocking possible on three sides
• LED indicator shows solenoid operation
• 500N locking retention force
Part Numbers
Mechanical Spring Lock (power solenoid to unlock)
Contact Configuration Cable
Length Part Number
(Actuator inserted) (Solenoid OFF)
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
31 32
53 54
1m
3m
5m
HS6E-L44B01-G
HS6E-L44B03-G
HS6E-L44B05-G
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
31 32
51 52
1m
3m
5m
HS6E-M44B01-G
HS6E-M44B03-G
HS6E-M44B05-G
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
33 34
53 54
1m
3m
5m
HS6E-N44B01-G
HS6E-N44B03-G
HS6E-N44B05-G
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
33 34
51 52
1m
3m
5m
HS6E-P44B01-G
HS6E-P44B03-G
HS6E-P44B05-G
1. Contact configuration shows the contact status when actuator is inserted and solenoid off for spring lock.
2. Contact configuration shows the contact status when actuator is inserted and solenoid on for solenoid lock.
3. Indicator LED color is green.
4. Actuator keys are not supplied with the interlock switch and must be ordered separately.
5. Standard stock items in bold.
Solenoid Lock (remove power to solenoid to unlock)
Contact Configuration Cable
Length Part Number
(Actuator inserted) (Solenoid ON)
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
22
11
21
12 4241
5453
41 421211
11 12 4241
41 421211
21 22
51 52
51 52
Main Circuit:
Main Circuit:
Main Circuit:
Main Circuit:
33 34
31 32
53 54
3433
2221
3231
2221
1m
3m
5m
HS6E-L7Y4B01-G
HS6E-L7Y4B03-G
HS6E-L7Y4B05-G
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
31 32
51 52
1m
3m
5m
HS6E-M7Y4B01-G
HS6E-M7Y4B03-G
HS6E-M7Y4B05-G
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
33 34
53 54
1m
3m
5m
HS6E-N7Y4B01-G
HS6E-N7Y4B03-G
HS6E-N7Y4B05-G
Monitor Circuit:
Monitor Circuit:
41 421211
21 22
Main Circuit:
33 34
51 52
1m
3m
5m
HS6E-P7Y4B01-G
HS6E-P7Y4B03-G
HS6E-P7Y4B05-G
A1A2
(+) (–)
A1A2
(+) (–)
291
800-262-IDEC (4332) USA & Canada
HS6E
Solenoid Locking Safety Switches
Overview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
Actuator Keys
Appearance Item Ordering Part Number Remarks
Straight Actuator HS9Z-A61 The retention force of HS9Z-A61 actuator is 500N maximum.
Do not apply excessive load.
Right-angle Actuator HS9Z-A62
The retention force of HS9Z-A62 actuator is 100N maximum.
Do not apply excessive load.
When retention force of 100N or more is required, use the HS9Z-A62S actuator.
Right-angle Actuator
with Mounting Plate HS9Z-A62S The retention force of HS9Z-A62S actuator is 500N maximum.
Do not apply excessive load.
Horizontal/Vertical
Angle Adjustable
Actuator
HS9Z-A65 The HS9Z-A65 and HS9Z-A66 have their metal actuator installed in opposite directions.
Select actuator by determining the required moving direction in consideration of the door
and interlock switch.
See page 294 for more information.
The retention force of HS9Z-A65 and HS9Z-A66 500N maximum.
Horizontal/Vertical
Angle Adjustable
Actuator
HS9Z-A66
Accessory
Description Part Number
Manual Unlock Key (long type) HS9Z-T3
Specifications
Conforming to Standards
UL 508 (UL listed), CSA C22.2, No. 14 (c-UL listed), ISO
14119
IEC 60947-5-1, EN 60947-5-1 (TÜV approval), EN 1088 (TÜV
approval), GS-ET-19
IEC 60204-1/EN 60204-1 (applicable standards for use)
Operating Temperature –25 to +50°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Operating Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui)300V (between LED and ground: 60V)
Impulse Withstand Voltage (Uimp)
Main & lock monitor circuits: 1.5 KV
Door monitor circuit: 2.5 kV
Between solenoid/LED and ground: 0.5 kV
Insulation Resistance
(500V DC megger)
Between live and dead metal parts: 100 MΩ minimum
Between terminals of different poles: 100 MΩ minimum.
Contact Resistance
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Electric Shock Protection Class Class II (IEC 61140)
Pollution Degree 3
Degree of Protection IP67 (IEC 60529)
Vibration
Resistance
Operating Extremes 10 to 55 Hz, amplitude 0.35mm
Damage Limits 30 Hz, amplitude 1.5 mm
Shock
Resistance
Operating Extremes 100 m/s2 (10G)
Damage Limits 1000 m/s2 (100G)
Actuator Operating Speed 0.05 to 1.0 m/s
Direct Opening Travel 8.0 mm minimum
OverviewXW Series E-StopsInterlock SwitchesEnabling SwitchesSafety Control RelaysLight CurtainsAS-Interface Safety at Work
HS6E Solenoid Locking Safety Switches
292 www.IDEC.com
Direct Opening Force 60N minimum
Actuator Retention Force 500N maximum (GS-ET-19)
Operating Frequency 900 operations/hour
Mechanical Life 1,000,000 operations minimum (GS-ET-19)
Electrical Life
100,000 operations minimum (rated load)
1,000,000 operations minimum (24V AC/DC, 100 mA)
(operating frequency 900 operations/hr)
Conditional Short-circuit Current 50A (250V) (Use 250V/10A fast-blow fuse for short-circuit
protection.)
Cable 22 AWG (12-core: 0.3 mm2 or equivalent/core)
Cable Diameter ø7.6 mm
Weight Approx. 200g
1. UL, c-UL rating: Main/Lock monitor circuit: 125V AC, 1A Pilot duty, 125V DC, 0.22A Pilot duty
Door monitor circuit:240V AC, 0.75A Pilot duty250V DC, 0.27A Pilot duty
2. TÜV rating: Main/Lock monitor circuit: AC-15 125V/1A, DC-13 125V/0.22A
Door monitor circuit: AC-15 240V/0.75A, DC-13 250V/0.27A
Solenoid/Indicator
Locking Mechanism Spring Lock Type or Solenoid Lock Type
Rated Voltage 24V DC
Current 110 mA (solenoid 100 mA, LED 10 mA)
Solenoid
Coil Resistance 240Ω (at 20°C)
Pickup Voltage Rated voltage × 85% maximum (at 20°C)
Dropout Voltage Rated voltage × 10% minimum (at 20°C)
Maximum Continuous Applicable Voltage Rated voltage × 110%
Maximum Continuous Applicable Time Continuous
Insulation Class Class F
Indicator Light Source LED
Illumination Color Green
Contact Ratings
Rated Operating
Current (Ie)
Operating Voltage (Ue) 30V 125V 250V
Main and Lock
Monitor Circuits
AC Resistive load (AC-12)
Inductive load (AC-15) 2A
1A
DC Resistive load (DC-12)
Inductive load (DC-13)
2A
1A
0.4A
0.22A
Door Monitor Circuit
AC Resistive load (AC-12)
Inductive load (AC-15) 2.5A
1.5A
1.5A
0.75A
DC Resistive load (DC-12)
Inductive load (DC-13)
2.5A
2.3A
1.1A
0.55A
0.55A
0.27A
1. UL, c-UL rating: Main/Lock monitor circuit: 125V AC, 1A Pilot duty, 125V DC, 0.22A Pilot duty
Door monitor circuit:240V AC, 0.75A Pilot duty250V DC, 0.27A Pilot duty
2. TÜV rating: Main/Lock monitor circuit: AC-15 125V/1A, DC-13 125V/0.22A
Door monitor circuit: AC-15 240V/0.75A, DC-13 250V/0.27A
293
800-262-IDEC (4332) USA & Canada
HS6E
Solenoid Locking Safety Switches
Overview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
Dimensions (mm)
Interlock Switch
30
20 to 22
20.5
28.5
41.8
(ø4.3 or M4 tapped hole
3-M4 S crew
Hole for Manual Unlocking
ø12 (reference)
(ø4.3 or M4 tapped hole)
3-M4 Screw Hole for Manual Unlocking
ø12 (reference)
20.5
20 to 22
30
28.5
41.8
M a nua l Unlocking Key
1
120
(2.3)
C12
35
30
20.5
4
4
5.5
10.1
15
10.4
15
4
4
75
R2.1
28.5
37
41.8
46.1
ø4.4
(22.5) (22.5)
Mounting Hole Layout
When using straight actuator
(HS9Z-A61)
(12.6±1)
22.6±1
22.6 ±1
Actuator Stop
(supplied)
Actuator Stop
(supplied)
Actuator Stop
(supplied)
(5)
50.8
0.8
(14)
(14)
(6.2)
(42) (Note)
0.8
0.8
48.8
(25)
When using right-angle actuator
(HS9Z-A62)
(12.6±1)
22.6±1
22.6 ±1
Actuator Stop
(supplied)
Actuator Stop
(supplied) Actuator Stop
(supplied)
(5)
50.8
0.8
(14)
(14)
(6.2)
(42) (Note)
0.8
0.8
48.8
(25)
When using horizontal/vertical
angle adjustable actuator
(HS9Z-A65/A66)
(12.6±1)
22.6±1
22.6 ±1
Actuator Stop
(supplied)
Actuator Stop
(supplied)
Actuator Stop
(supplied)
(5)
50.8
0.8
(14)
(14)
(6.2)
(42) (Note)
0.8
0.8
48.8
(25)
Actuator Mounting Reference Position
As shown in the figure on the right, the mounting reference position of the actuator key when inserted
in the interlock switch is:
The actuator stop on the actuator lightly touches the interlock switch.
After mounting the actuator, remove the actuator stop from the
actuator.
0.8
Interlock Switch Door Stop
Actuator Stop
HS9Z-A61 Actuator
Door Stop
OverviewXW Series E-StopsInterlock SwitchesEnabling SwitchesSafety Control RelaysLight CurtainsAS-Interface Safety at Work
HS6E Solenoid Locking Safety Switches
294 www.IDEC.com
Actuator Key Dimensions (mm)
Straight Actuator (HS9Z-A61)
Rubber Bushing
Note 1
Actuator Stop (supplied)
3.5
1.2
When
mounted (5) 14
8.4
43.2
14 15 0.8
(15.8)
20.9
10.4
2-ø9
2-ø4.3
The actuator stop is used to adjust the actuator position. Remove after the actuator position is mounted.
Straight Actuator (HS9Z-A61) Right-angle
Actuator (HS9Z-A62)
The retention force of the HS9Z-A62 actuator is 100N.
When tensile force exceeding 100N is expected, use
the HS9Z-A62S actuator.
When mounted (33.8)
When
mounted (5.6)
When mounted (5)
Rubber Bushing
(Note) Actuator Stop (supplied)
14
2-ø4.3
34
1413.1
3.5
1.2
8.4
0.8
ø2-9
Right-angle Actuator
with Mounting Plate (HS9Z-A62S)
Note: See page 297 for actuator installation.
Mounting Plate (supplied)
0.8
1.2
3.5
14
13.1 14
41.1
8.4
2-ø9
2-ø4.2
When mounted (33.8)
When mounted (6.2)
When mounted (6.2)
When mounted (10.2)
(Note) Actuator Stop (supplied)
Rubber Bushing
Angle Adjustable Actuator
(HS9Z-A65)
Orienting Insert
Orienting Insert
(Note)
Actuator Stop (supplied)
(M4 Holes)
Angle Adjustment
(M3 Hexagon Socket Head Screw)
Angle Adjustment
(M3 Hexagon Socket
Head Screw)
Horizontal Adjustment
Vertical Adjustment
34
7.5
28.2 13
2.5
2
20°
5.5
16.8
25
15
20°
R2.1
0.8
1.2
3.5
Angle Adjustable Actuator
(HS9Z-A66)
The HS9Z-A65 and HS9Z-A66 have the
metal actuator inserted in opposite direc-
tions.
20°
Angle Adjustment
(M3 Hexagon Socket Head Screw)
Horizontal Adjustment
Vertical Adjustment
20°
Angle Adjustment
(M3 Hexagon Socket Head Screw)
(Note 1)
Actuator Stop (Supplied)
Actuator Adjustment
Orientation
The orientation of actuator adjustment (horizon-
tal/vertical) can be changed using the orienting
insert (white plastic) installed on the back of the
actuator.
Orienting Insert
Horizontal Adjustment Vertical Adjustment
Angle Adjustable Actuator
(HS9Z-A65)
25
2-M4 Screw
(ø4.3 or M4 tapping screw)
Manual Unlock Key (plastic)
(supplied with switch, not replaceable)
4
130
15
ø4
ø10
(24)
6.5
(24.5)
18
3
915
Manual Unlock Key, HS9Z-T3 (metal)
4
130
15
ø4
ø10
(24)
6.5
(24.5)
18
3
915
295
800-262-IDEC (4332) USA & Canada
HS6E
Solenoid Locking Safety Switches
Overview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
Circuit Diagrams and Operating Characteristics
Spring Lock Type Status 1 Status 2 Status 3 Status 4 Unlocking Using
Manual Unlock Key
Interlock Switch Status
Door closed
Machine ready to
operate
Solenoid de-energized
Door opened
Machine cannot be
operated
Solenoid energized
Door open
Machine cannot be
operated
Solenoid energized
Door open
Machine cannot be
operated
Solenoid de-energized
Door closed
Machine cannot be
operated
Solenoid de-energized
Door Status
Manually
Unlocked
LOCK
UNLOCK
Circuit Diagram (Example: HS6E-N4)
22
3433
21
A1
(–)
A2
(+)
53
4112
54
4211
21
33 34
22
11 42
54
12 41
53
(+)
A2
(–)
A1
22
3433
21
A1
(–)
A2
(+)
53
4112
54
4211
A1
(–)
A2
(+)
53
4112
54
4211
22
3433
21
Door Closed (locked) Closed (unlocked) Open Open Closed (unlocked)
Part Number and Circuit Diagram
HS6E-L4
Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door closed) 31-32 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Lock Monitor Circuit
(unlocked) 53-54 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed)
HS6E-M4 Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door closed) 31-32 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Lock Monitor Circuit
(locked) 51-52 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
HS6E-N4 Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door open) 33-34 OFF (open) OFF (open) ON (closed) ON (closed) OFF (open)
Lock Monitor Circuit
(unlocked) 53-54 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed)
HS6E-P4 Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door open) 33-34 OFF (open) OFF (open) ON (closed) ON (closed) OFF (open)
Lock Monitor Circuit
(locked) 51-52 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Solenoid Power A1-A2 (all types) OFF (de-energized) ON (energized) ON (energized) OFF (de-energized) OFF (de-energized)
Main circuit: Connected to the machine drive control circuit, sending the interlock signals of the protective door.
Monitor circuit: Sends the monitoring signals of open/closed and lock/unlocked statuses of the protective door.
Operation Characteristics (reference)
27.4 (stroke in mm)
5.0
1.1
0
4.7
Door Monitor Circuit (door closed, NC)
Lock Monitor Circuit (locked, NC)
Door Monitor Circuit (door open, NO)
Main Circuit
Lock Monitor Circuit (unlocked, NO)
: Contacts ON (closed)
: Contacts OFF (open)
(Actuator Insertion Position)
(Locked Position)
The characteristics shown in the chart above are of the HS9Z-A61, -A62, -A65, and -A66 actuators. For the HS9Z-A62S actuator, subtract 0.6 mm.
The characteristics show the contact status when the actuator enters an entry slot of an interlock switch.
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
A1A2
(+) (–)
22
11
21
12 4241
5453
41 421211
11 12 4241
41 421211
21 22
51 52
51 52
Main Circuit:
Main Circuit:
Main Circuit:
Main Circuit:
33 34
31 32
53 54
3433
2221
3231
2221
Door
Monitor
Lock
Monitor
OverviewXW Series E-StopsInterlock SwitchesEnabling SwitchesSafety Control RelaysLight CurtainsAS-Interface Safety at Work
HS6E Solenoid Locking Safety Switches
296 www.IDEC.com
Solenoid Lock Type Status 1 Status 2 Status 3 Status 4 Unlocking Using
Manual Unlock Key
Interlock Switch Status
Door closed
Machine ready to
operate
Solenoid energized
Door closed
Machine cannot be
operated
Solenoid de-energized
Door open
Machine cannot be
operated
Solenoid de-energized
Door open
Machine cannot be
operated
Solenoid de-energized
Door open
Machine cannot be
operated
Solenoid de-energized
Door Status
Manually
Unlocked
LOCK
UNLOCK
Circuit Diagram (Example: HS6E-N7Y)
22
3433
21
A1
(–)
A2
(+)
53
4112
54
4211
21
33 34
22
11 42
54
12 41
53
(+)
A2
(–)
A1
22
3433
21
A1
(–)
A2
(+)
53
4112
54
4211
A1
(–)
A2
(+)
53
4112
54
4211
22
3433
21
Door Closed (locked) Closed (unlocked) Open Open Closed (unlocked)
Part Number and Circuit Diagram
HS6E-L7Y
Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door closed) 31-32 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Lock Monitor Circuit
(unlocked) 53-54 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed)
HS6E-M7Y Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door closed) 31-32 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Lock Monitor Circuit
(locked) 51-52 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
HS6E-N7Y Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door open) 33-34 OFF (open) OFF (open) ON (closed) ON (closed) OFF (open)
Lock Monitor Circuit
(unlocked) 53-54 OFF (open) ON (closed) ON (closed) ON (closed) ON (closed)
HS6E-P7Y Main Circuit 11-42 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Door Monitor Circuit
(door closed) 21-22 ON (closed) ON (closed) OFF (open) OFF (open) ON (closed)
Door Monitor Circuit
(door open) 33-34 OFF (open) OFF (open) ON (closed) ON (closed) OFF (open)
Lock Monitor Circuit
(locked) 51-52 ON (closed) OFF (open) OFF (open) OFF (open) OFF (open)
Solenoid Power A1-A2 (all types) ON (energized) OFF (de-energized) OFF (de-energized) ON (energized)
(Note 2)
OFF (de-energized)
to ON (re-energized)
(Note 1) (Note 2)
Main circuit: Connected to the machine drive control circuit, sending the interlock signals of the protective door.
Monitor circuit: Sends the monitoring signals of open/closed and lock/unlocked statuses of the protective door.
Note 1: Do not attempt manual unlocking while the solenoid is energized.
Note 2: Do not energize the solenoid for a long period of time while the door is open
or while the door is unlocked manually using the manual unlock key.
Operation Characteristics (reference)
27.4 (stroke in mm)
5.0
1.1
0
4.7
Door Monitor Circuit (door closed, NC)
Lock Monitor Circuit (locked, NC)
Door Monitor Circuit (door open, NO)
Main Circuit
Lock Monitor Circuit (unlocked, NO)
: Contacts ON (closed)
: Contacts OFF (open)
(Actuator Insertion Position)
(Locked Position)
The characteristics shown in the chart above are of the HS9Z-A61, -A62, -A65, and -A66 actuators. For the HS9Z-A62S actuator, subtract 0.6 mm.
The characteristics show the contact status when the actuator enters an entry slot of an interlock switch.
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
Monitor Circuit:
A1A2
(+) (–)
22
11
21
12 4241
5453
41 421211
11 12 4241
41 421211
21 22
51 52
51 52
Main Circuit:
Main Circuit:
Main Circuit:
Main Circuit:
33 34
31 32
53 54
3433
2221
3231
2221
Door
Monitor
Lock
Monitor
297
800-262-IDEC (4332) USA & Canada
HS6E
Solenoid Locking Safety Switches
Overview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
Operating Instructions
Minimum Radius of Hinged Door
• When using the interlock switch on hinged doors, refer to the minimum radius
of doors shown below. When using on doors with small minimum radius, use
the angle adjustable actuator (HS9Z-A65 and HS9Z-A66).
Note: Because deviation or dislocation of hinged doors may occur in actual applications, make sure
of the correct operation before installation.
When Using the HS9Z-A62/A62S Right-angle Actuator
• When door hinge is on the extension line of the interlock switch surface:
• When door hinge is on the extension line of the actuator mounting surface:
When using the HS9Z-A65/HS9Z-A66 Angle Adjustable Actuator
•Whendoorhingeisontheextensionlineoftheinterlockswitchsurface
Horizontal Adjustment
50 mm
50 mm
50 mm
50 mm
HS9Z-A66
HS9Z-A65
HS9Z-A65
HS9Z-A66
Label
Minimum
Radius
Minimum
Radius
Minimum
Radius
Minimum
Radius
Door Hinge
Door Hinge
Door Hinge
Door Hinge
Horizontal Adjustment Vertical Adjustment
HS9Z-A65
HS9Z-A66
70 mm
70 mm
HS9Z-A65
HS9Z-A66
70mm
70mm
Label
Minimum
Radius
Minimum
Radius
Minimum Radius
Minimum Radius
Door Hinge
Door Hinge
Door Hinge
Door Hinge
Horizontal Adjustment Vertical Adjustment
Vertical Adjustment
•Whendoorhingeisontheextensionlineoftheactuatormountingsurface
Horizontal Adjustment
50 mm
50 mm
50 mm
50 mm
HS9Z-A66
HS9Z-A65
HS9Z-A65
HS9Z-A66
Label
Minimum
Radius
Minimum
Radius
Minimum
Radius
Minimum
Radius
Door Hinge
Door Hinge
Door Hinge
Door Hinge
Horizontal Adjustment Vertical Adjustment
HS9Z-A65
HS9Z-A66
70 mm
70 mm
HS9Z-A65
HS9Z-A66
70mm
70mm
Label
Minimum
Radius
Minimum
Radius
Minimum Radi
us
Minimum Radi
us
Door Hinge
Door Hinge
Door Hinge
Door Hinge
Horizontal Adjustment Vertical Adjustment
Vertical Adjustment
Actuator Angle Adjustment for the HS9Z-A65/HS9Z-A66
• Using the angle adjustment screw, the actuator angle can be adjusted (see
figures on page 370).
Adjustable angle: 0 to 20°
• The larger the adjusted angle of the actuator, the smaller the applicable
radius of the door opening.
• After installing the actuator, open the door. Then adjust the actuator so that
its edge can enter properly into the actuator entry slot of the interlock switch.
• After adjusting the actuator angle, apply Loctite to the adjustment screw so
that the screw will not become loose.
Mounting Examples
HS9Z-A61 Actuator
Door
HS6E
Interlock Switch
Door Stop
Application on Sliding Doors Application on Hinged Doors
Latch
HS9Z-A62S Actuator
Note: When mounting the actuator, make sure that the actuator enters
the slot in the correct direction, as shown on the right.
For Manual Unlocking
When using the manual unlock key
Manual Unlocking
Position
Normal Position
(installed on both sides)
Manual Unlocking
UNLOCK
LOCK
• Using the interlock switch with the actuator not fully turned (less than 90°)
may cause damage to the interlock switch or operation failures (when manu-
ally unlocked, the switch will keep the main circuit disconnected and the door
unlocked).
• Do not apply excessive force (0.45 N·m or more) to the manual unlock part,
otherwise the manual unlock part will become damaged.
Manual Unlock Key
(supplied with the interlock switch)
See instruction manual for full details.
Door Hinge
Door Hinge
Minimum Radius
Minimum Radius
160 mm
160 mm
Door Hinge Door Hinge
Minimum Radius
Minimum Radius
230 mm
230 mm
OverviewXW Series E-StopsInterlock SwitchesEnabling SwitchesSafety Control RelaysLight CurtainsAS-Interface Safety at Work
HS6E Solenoid Locking Safety Switches
298 www.IDEC.com
Recommended Tightening Torque of Mounting Screws
• Interlock switch: 1.0 to 1.5 N·m (three M4 screws)
• Actuators: 1.0 to 1.5 N·m (two M4 screws)
Cables
• Do not fasten or loosen the gland at the bottom of the interlock switch.
• When bending the cable during wiring, make sure that the cable radius is kept
at 30 mm minimum.
• When wiring, make sure that water or oil does not enter from the end of the
cable.
• Do not open the lid of the interlock switch. Otherwise the interlock switch will
be damaged.
• The solenoid has polarity. Make sure of the correct polarity when wiring.
Gland
Gland
30 mm
Minimum Radius
(70)
(50)
30 mm
Minimum
Radius
Wire Identification
•Wirescanbeidentiedbycolorandorawhitelineprintedonthewire.
No. Insulation Color No. Insulation Color
1 Blue/White 7 White
2 Gray 8 Black
3 Pink 9 Pink/White
4 Orange 10 Brown/White
5 Orange/White 11 Brown
6 Gray/White 12 Blue
Terminal Number Identification
• When wiring, identify the terminal number of each contact by the color of the
insulation.
• The following table shows the identification of terminal numbers.
• When wiring, cut unused wires to avoid incorrect wiring.
BlackWhite
Orange/White
Brown/White
Orange/White
Brown/White
Orange/White
Brown/White
22
Orange/White
Brown/White
Pink
Pink
Pink
Pink/White
Pink/White
Pink/White
Pink/White
Blue/White
Blue/White
Blue/White
Blue/White
Pink
Contact ArrangementType
A1A2
(+) (–)
22
11
21
2421 41
5453
41 421211
242111 41
41 421211
21 22
51 52
51 52
Door Monitor Lock Monitor
Orange
Brown
Orange
Brown
Orange
Brown
Orange
Brown
Blue
Blue
Blue
Blue
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Monitor circuit:
Main circuit:
Main circuit:
Main circuit:
Main circuit:
HS6E-L
HS6E-M
HS6E-N
HS6E-P
33 34
31 32
53 54
3433
2221
3231
21
Note: The contact arrangements show the contact status when the actuator is inserted and locked.