291
800-262-IDEC (4332) • USA & Canada
HS6E
Solenoid Locking Safety Switches
Overview XW Series E-Stops Interlock Switches Enabling Switches Safety Control Relays Light Curtains AS-Interface Safety at Work
Actuator Keys
Appearance Item Ordering Part Number Remarks
Straight Actuator HS9Z-A61 The retention force of HS9Z-A61 actuator is 500N maximum.
Do not apply excessive load.
Right-angle Actuator HS9Z-A62
The retention force of HS9Z-A62 actuator is 100N maximum.
Do not apply excessive load.
When retention force of 100N or more is required, use the HS9Z-A62S actuator.
Right-angle Actuator
with Mounting Plate HS9Z-A62S The retention force of HS9Z-A62S actuator is 500N maximum.
Do not apply excessive load.
Horizontal/Vertical
Angle Adjustable
Actuator
HS9Z-A65 The HS9Z-A65 and HS9Z-A66 have their metal actuator installed in opposite directions.
Select actuator by determining the required moving direction in consideration of the door
and interlock switch.
See page 294 for more information.
The retention force of HS9Z-A65 and HS9Z-A66 500N maximum.
Horizontal/Vertical
Angle Adjustable
Actuator
HS9Z-A66
Accessory
Description Part Number
Manual Unlock Key (long type) HS9Z-T3
Specifications
Conforming to Standards
UL 508 (UL listed), CSA C22.2, No. 14 (c-UL listed), ISO
14119
IEC 60947-5-1, EN 60947-5-1 (TÜV approval), EN 1088 (TÜV
approval), GS-ET-19
IEC 60204-1/EN 60204-1 (applicable standards for use)
Operating Temperature –25 to +50°C (no freezing)
Storage Temperature –40 to +80°C (no freezing)
Operating Humidity 45 to 85% (no condensation)
Rated Insulation Voltage (Ui)300V (between LED and ground: 60V)
Impulse Withstand Voltage (Uimp)
Main & lock monitor circuits: 1.5 KV
Door monitor circuit: 2.5 kV
Between solenoid/LED and ground: 0.5 kV
Insulation Resistance
(500V DC megger)
Between live and dead metal parts: 100 MΩ minimum
Between terminals of different poles: 100 MΩ minimum.
Contact Resistance
300 mΩ maximum (initial value, 1m cable)
500 mΩ maximum (initial value, 3m cable)
700 mΩ maximum (initial value, 5m cable)
Electric Shock Protection Class Class II (IEC 61140)
Pollution Degree 3
Degree of Protection IP67 (IEC 60529)
Vibration
Resistance
Operating Extremes 10 to 55 Hz, amplitude 0.35mm
Damage Limits 30 Hz, amplitude 1.5 mm
Shock
Resistance
Operating Extremes 100 m/s2 (10G)
Damage Limits 1000 m/s2 (100G)
Actuator Operating Speed 0.05 to 1.0 m/s
Direct Opening Travel 8.0 mm minimum