GAMMA instabus
Technical Product Information
May 2009
AP 421/3 IR wall switch, double, titanium white 5WG1 421-3AB13
Siemens AG AP 421/3, 4 pages Technical Manual
Industry Sector, Building Technologies
Electrical Installation Technology © Siemens AG 2009 Update: http://www.siemens.com/gamma
P.O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice
2.9.3.6/1
Product and Applications Description
The AP 421/3 IR wall switch in the design DELTA style is
available with the color titanium white and with a black
cover over the IR diodes.
For wireless control of actuators the AP 421/3 IR wall
switch transmits IR signals that are received by the S 450
IR receiver decoder or a wall switch with IR receiver-
decoder, which transposes them into corresponding bus
telegrams. Thus the IR wall switch can send e.g. com-
mands to actuators for defined on/off switching or dim-
ming of lamps, or for moving Venetian blinds up/down or
moving their slats.
The IR wall switch is powered by two batteries of type Al-
kaline (LR03/AAA; 1,5V).
Note
The batteries (Alkaline LR03/AAA, 1,5V) are not included
and have to be sourced separately.
Application programs
none
Example of Operation
S 450
Installation notes
V WARNING
The device must be mounted and commissioned by an
authorised electrician.
The prevailing safety rules must be heeded.
For planning and construction of electric installations,
the relevant guidelines, regulations and standards of
the respective country are to be considered.
GAMMA instabus
Technical Product Information
May 2009
AP 421/3 IR wall switch, double, titanium white 5WG1 421-3AB13
Technical Manual AP 421/3, 4 pages Siemens AG
Industry Sector, Building Technologies
Update: http://www.siemens.com/gamma © Siemens AG 2009 Electrical Installation Technology
Subject to change without further notice P.O. Box 10 09 53, D-93009 Regensburg
2.9.3.6/2
Technical Specifications
Power supply
two batteries Alkaline LR03/AAA, 1,5V
IR transmission unit
light wave length: 890 nm
transmission freq.: 455 kHz
transmission range:
(the receiver must be within uninterrupted optical reach)
- black LED cover: approx. 8 m unfocused
adjustable channels: 2 of 64
Configuration elements
for channel selection:
slide switches (built in the device), access is possible af-
ter removing the bottom part
Operating elements
2 pairs of 2 facing rockers each
Display elements
1 red LED:
LED for transmission and battery observance
flashing on rocker depression
Physical specifications
Housing: plastic
dimensions (W x H x D): 82 x 115 x 21mm
weight: approx. 80 g (without battery)
Fire load: approx. 3040 kJ ± 10 %
Electrical safety
Degree of pollution (according to IEC 60664-1): 2
Type of protection (according to EN 60529): IP 20
Reliability
Failure rate: 170 fit at 40°C
EMC requirements
Complies with EN 50090-2-2, EN 61000-6-2
Environmental specifications
climatic conditions: EN 50090-2-2
ambient temperature operating: - 5 ... + 45 °C
ambient temperature non-op.: - 25 ... + 70 ° C
relative humidity (non-condensing): 5 % to 93 %
Markings: CE
CE mark
in accordance with the EMC directive (residential,
commercial, and industrial buildings)
Location and Function of the Display and Operat-
ing Elements
A1
A2
A3 A4
Figure 1: Display and operating elements
A1 IR transmission diodes
A2 LED for transmission and battery observance
flashing on rocker depression;
no display when depressing rocker: replace battery
A3 label field
A4 rocker switch
top depression (1) = ON/UP/BRIGHTER
bottom depression (0) = OFF/DOWN/DARKER
Battery change
The LED flashes for five seconds after a rocker has been
depressed if a battery change is required.
- Dismount the wall switch
- Remove the empty batteries and replace these with
new batteries (Alkaline LR03/AAA, 1,5V)
- NOTE:
Obey the applicable regulations when disposing the
empty batteries.
- Mount the wall switch
- NOTE:
If within two seconds after inserting the batteries the
button below the SIEMENS logo is pressed for five sec-
onds, the wall switch is set to send IR signals immedi-
ately when a button is pressed. In conjunction with the
new S 450 IR receiver decoder swicthing and dimming
commands can be issued faster by the remote. This
setting is active until the next battery change.
GAMMA instabus
Technical Product Information
May 2009
AP 421/3 IR wall switch, double, titanium white 5WG1 421-3AB13
Siemens AG AP 421/3, 4 pages Technical Manual
Industry Sector, Building Technologies
Electrical Installation Technology © Siemens AG 2009 Update: http://www.siemens.com/gamma
P.O. Box 10 09 53, D-93009 Regensburg Subject to change without further notice
2.9.3.6/3
B3
Mounting and wiring
Mounting notes
- Take care that the line of sight from the transmission
diodes to the receiver is sufficiently free. Especially, if
persons are standing in front of the device in order to
use it.
- The base plate of the IR-transmitter can be mounted
with screws or optionally with the included double
faced adhesive film.
Figure 2a
Figure 2b
B10
B
4
Figure 2c
B1 IR wall switch, side view
B2 latching screw
B3 interlocking clamps
B4 base plate, front view
B5 base plate, rear view
B6 horizontal/vertical long slots
B7 recesses for adhesive tape
B8 double faced adhesive tape
B9 protective films
B10 Non-transparent foil (for mounting on transparent
material)
B11 Label
B12 Slide switches for selection of the IR transmission
channel
B13 battery compartment AAA
Mounting of the base plate (Figure 2)
with screws
- Pierce the horizontal or vertical holes (B6) of the base
panel (B4) with a screw-driver or another suitable tool.
- Attach the base panel (B4) with screws respectively
with dowels and screws.
with double faced adhesive tape
- Remove one of the protection films (B9) from the dou-
ble-faced adhesive tape (B8) and stick the tape in the
recesses (B7) on the device's back side.
- Strip off the remaining protection films (B9) and push
the base panel onto a smooth, dustless and greaseless
foundation or the non-transparent foil.
- When installing on transparent material (e.g. glass)
stick the transparent foil (B10) on the transparent ma-
terial.
Mounting the IR wall switch (Figure 3)
- Insert the batteries into the wall switch (B1)
- Select the desired IR transmission channel with the
sliding switches (B12) on the rear side of the wall
switch (B1).
- Hang the device onto the base panel with its upper
side and click it into place at the retaining clamps with
its bottom side to attach the device on the base panel.
- Secure the wall switch with the included latching
screw (B2) against unintentional dismounting.
B11
B12
B13
Figure 3a
B3
Figure 3b Figure 3c
GAMMA instabus
Technical Product Information
May 2009
AP 421/3 IR wall switch, double, titanium white 5WG1 421-3AB13
Technical Manual AP 421/3, 4 pages Siemens AG
Industry Sector, Building Technologies
Update: http://www.siemens.com/gamma © Siemens AG 2009 Electrical Installation Technology
Subject to change without further notice P.O. Box 10 09 53, D-93009 Regensburg
2.9.3.6/4
Dismounting the IR wall switch (Figure 4)
- Unscrew the latching screw (B2) on the bottom side of
the wall switch (B1).
- Insert the screw driver below the screw hole for the
latching screw, detach the wall switch from the base
plate by swiveling the screw driver up and lift the wall
switch from the base plate.
B
2
B
2
B
2
B1
B1
Figure 4
Select IR transmission channel
The AP 420/3 IR wall switch uses one channel for trans-
mitting the IR signals. A maximum of 64 channels are
available.
The transmission channel is selected with the sliding
switches 1 to 6 (figure 5) that are on the rear side of the
device (B12).
312 4 56
Figure 5
Channel assignment dependent on the sliding switch po-
sitions
slide switch
channel 1 2 3 4 5 6
0 0 0 0 0 0 0
1 0 0 0 0 0 1
2 0 0 0 0 1 0
3 0 0 0 0 1 1
4 0 0 0 1 0 0
5 0 0 0 1 0 1
6 0 0 0 1 1 0
7 0 0 0 1 1 1
8 0 0 1 0 0 0
:
61 1 1 1 1 0 1
62 1 1 1 1 1 0
63 1 1 1 1 1 1
Dimension drawing
Dimensions in mm
82
115
21
General Notes
The operating instructions must be handed over to the
client.
Any faulty devices should be returned to the local Sie-
mens office.
If you have further questions concerning the product
please contact our technical support:
+49 (0) 180 50 50-222
(0,14 €/min. from the German landline network, deviat-
ing mobile communications prices are possible)
+49 (0) 180 50 50-223
E-Mail: support.automation@siemens.com
www.siemens.com/automation/support-request