TS SERIES
25 TO 250 mA
MEETS MIL-R-28750/5,6, & 7
FEATURES
Hermetically sealed TO-5 package
Transformer coupled
High speed switching
TS5-1Y switches AC or DC
INPUT CHARACTERISTICS
INPUT VOLTAGE RANGE
4.0 – 7.0 Vdc
MAXIMUM TURN-ON VOLTAGE
5.0 Vdc
MINIMUM TURN-OFF VOLTAGE
1.0 Vdc
I/O DIELECTRIC
1000 Vac pk-pk
OUTPUT CHARACTERISTICS
MAX. OUTPUT CURRENT
(CONTINUOUS, 25°C)
50 mAac or mAdc (TS5-1Y)
250 mAdc (TS6-1Y)
100 mAdc (TS7-1Y)
MAX. OUTPUT VOLTAGE
40 Vac or Vdc (TS5-1Y)
40 Vdc (TS6-1Y)
250 Vdc (TS7-1Y)
MAX. ON-RESISTANCE
5 ohms (TS5-1Y)
TURN-ON TIME TURN-OFF TIME
10 µsec. 15 µsec.
ENVIRONMENTAL CHARACTERISTICS
SHOCK
1500 G’s, 0.5 ms.
VIBRATION
100 G’s, 10 to 2000 Hz
OPERATING AMBIENT TEMPERATURE
-55 to +125°C
DS11 SERIES
2 AMP
MEETS DESC DRAWINGS 88061/2
FEATURES
Hermetically sealed DIP package
Thick film hybrid construction
Optically isolated
Low on-resistance (MOSFET Output)
Optional: Switch status, short circuit
protection, trip status.
INPUT CHARACTERISTICS
INPUT VOLTAGE RANGE
3.8 – 32 Vdc
MAXIMUM TURN-ON VOLTAGE
3.8 Vdc
MINIMUM TURN-OFF VOLTAGE
1.5 Vdc
I/O DIELECTRIC
1000 Vr ms
OUTPUT CHARACTERISTICS
MAX. OUTPUT CURRENT
(CONTINUOUS, 25°C)
2 Adc
MAX. OUTPUT VOLTAGE
80 Vdc
MAX. ON-RESISTANCE
15 milliohms (at 100 mA load)
TURN-ON TIME TURN-OFF TIME
3 ms. 1 ms.
THERMAL RESISTANCE
Junction to Ambient:90°C/Watt
ENVIRONMENTAL CHARACTERISTICS
SHOCK
50 G’s, 11 ms.
VIBRATION
100 G’s, 10 to 3000 Hz
OPERATING AMBIENT TEMPERATURE
-55 to +105°C
DC SOLID STATE RELAYS
(+) OUTPUT LOAD
LOAD
(-) OUTPUT LOAD RETURN
LOAD RETURN
STATUS
OUTPUT
RETURN
136
12 8
CONTROL
BIAS
14
1
CONTROL
SOURCE DC SUPPLY
3
75
++
1
CONTROL
SOURCE AC OR ± DC SUPPLY
3
75
LOAD
LOAD
46
SOLID STATE RELAYS
Communications Instruments, Inc., 1396 Charlotte Hwy. P.O. Box 520 Fairview, NC 28730 (704) 628-1711 Fax(704) 628-1439
TERMINAL VIEW
TERMINAL VIEW
47
SOLID STATE RELAYS
Communications Instruments, Inc., 1396 Charlotte Hwy. P.O. Box 520 Fairview, NC 28730 (704) 628-1711 Fax(704) 628-1439
DC SOLID STATE RELAYS
EW
.335 DIA MAX (8.51)
0
0
3
6
9
12
15
51015202530405060
18
BIAS (INPUT) VOLTAGE (Vdc)
BIAS INPUT CURRENT (mA)
-60 -40 -20 20 40 60 80 100 120 140
10
20
30
40
50
60
70
80
400
90
300
200
100
AMBIENT TEMPERATURE (°C)
OUTPUT CURRENT (mA)
-60 -40 -20 20 40 60 80 100 120 140
10
20
30
40
50
60
70
80
400
90
300
200
100
AMBIENT TEMPERATURE (°C)
OUTPUT CURRENT (mA)
-60 -40 -20 20 40 60 80 100 120 140
1
2
3
4
5
6
7
8
9
10
20
30
40
50
60
70
80
100
90
AMBIENT TEMPERATURE (°C)
OUTPUT CURRENT (mA)
-55° C
-125° C
-55° C
-125° C
-55° C
-125° C
-55 15 25 35 45 55 65 75 85 95 105 115 125
0.00
0.50
1.00
1.50
2.00
2.50
AMBIENT TEMPERATURE (°C)
LOAD CURRENT (AMPERES)
1° C W/ HEAT SINK
.370 DIA MAX (9.40)
.275 MAX
(12.70)
.50 MIN
(12.70)
.017 DIA (0.43)
.100
(2.54)
.200
(5.08)
.031
.032
(REF)
(0.81)
45°
0
6 Vdc INPUT
5 Vdc INPUT
RATED CURRENT
4 Vdc INPUT
7 Vdc INPUT 6 Vdc INPUT
5 Vdc INPUT
RATED CURRENT
7 Vdc INPUT
0
6 Vdc INPUT
5 Vdc INPUT
RATED CURRENT
4 Vdc INPUT
7 Vdc INPUT
0
.300 ± .005
(7.62 ± .127)
.110 REF (2.79)
.140 REF
(3.56)
.490 REF
(12.4)
136
11 8
.200 REF
(5.08)
.600 REF (15.2)
.500 REF (17.7)
.190 MAX
(4.83)
.273 ± .020
(6.93 ± .508)
.020 MAX
(.508)
.017 (.432)
+.002 (.051) DIA
–.508 (.025) 5 PLS
.530 MAX
(13.5)
.850 (21.6) REF
.890 MAX (22.6)
4 Vdc INPUT
DS11
TS5/TS6/TS7
OUTPUT CURRENT VS. INPUT CONTROL VOLTAGE AND AMBIENT TEMPERATURE
DS11
BIAS (INPUT) CURRENT VS. BIAS (INPUT) VOLTAGE
DS11
THERMAL DERATING CURVE
TS5-1Y TS6-1Y TS7-1Y
NOTES: 1) Reversing polarity of input (or output except for TS5-1) may cause per-
manent damage. 2) Input must be a step function. Rise or fall time, as applicable, not
to exceed 100 µsec. 3) Inductive loads must be diode suppressed. 4) For any control
voltage, the maximum load current shown on graphs must not be exceeded.
Attempting to draw currents in excess of those specified on graphs can cause per-
manent damage.
NOTES: 1) Reversing polarity of output may cause per manent damage. 2) Inductive
loads must be diode suppressed.