BIMETAL DISC THERMOSTATS 3L12 SERIES 3L12 SERIES 1/2" disc MANUAL reset ROLLOUT LIMIT CONTROLS Manual Reset Flame Rollout Limit Switches Designed for Safety in Gas Fired Furnaces, Unit Heater and Roof-Top Units * * * * HEATING FEATURES Loose ring, stainless steel mounting brackets. /4" quick connect terminations. 90 orientation to mounting holes. Manual reset. Stainless steel disc cup (A1 disc cup for 3L12-301). 1 SPECIFICATIONS Single pole, single throw Open on temperature rise Electrical Ratings Resistive . . . . . . . 15A @ 120 VAC, 10A @ 240 VAC Inductive . . . . . . . 3.0 FLA, 12.0 LRA @ 120 VAC; 1.5 FLA, 6.0LRA @ 240 VAC Pilot Duty . . . . . . 125 VA Dimensions 3L12-301 . . . . . . . Length (1.18"), case width (.81"), height (.83") Others . . . . . . . . . Length (1.70"), case width (.81"), height (.83") Weight . . . . . . . . . . 0.2 oz. Agency . . . . . . . . . . UL Recognized File #E19279 CSA Certified File Number LR77886/LR109556 VDE Lic. 118631 Model Number NEW SERIES! Fixed Temperature Settings Cut-in Switch Therm-O-Disc Cut-out Action Style Type 3L12-130 130 Open on Rise 36TX16 611863 3L12-135 135 Open on Rise 36TX16 611864 3L12-220 220 Open on Rise 36TX16 611865 3L12-230 230 Open on Rise 36TX16 611686 3L12-240 Manual 240 Open on Rise 36TX16 611687 3L12-250 Reset 250 Open on Rise 36TX16 611868 3L12-260 260 Open on Rise 36TX16 611869 3L12-300 300 Open on Rise 36TX16 611870 3L12-350 350 Open on Rise 36TX16 611871 3L12-301* 300 Open on Rise 36TX16 611971 *Specifically designed for ICP part #1013102 3L12-301 only 3L12-130 - 350 www.white-rodgers.com 73