:: Mechanical Drawing
AC Fans
:: Pressure (P) vs. Flow (Q) Curves
:: Product table
Part No. Rated
Voltage
VAC
Operating
Voltage Range
VAC
Rated
Current
Amps
Rated Input
Power
Watts
Speed
RPM
Maximum
Airflow
m3/hour CFM
Maximum Air
Pressure
mm H2O in H2o
Noise
dBa
Lead
Type
GAA8038-115BB 115-50/60Hz 81-125 0.20 14 3000 49.3 29 5 0.2 34 Connector
GAA8038-230BB 230-50/60Hz 161-242 0.08 10 3000 49.3 29 5 0.2 34 Connector
:: 80 x 80 x 38 mm
:: 80 x 80 x 38 mm
* The maximum airflow and speed are measured in free air, at an
ambient temperature of 25ºc.
* The maximum air pressure is measured with zero airflow, at an
ambient temperature of 25ºc.
* the fan noise level is measured in a semi-anechoic chamber
where the background noise is below 18 dBA (+/-1 dBA).
* All readings are typical values at the rated voltage.
* Specifications are subject to change without notice.
* For more detailed specifications or other requests, please
contact Comair Rotron Technical Support.
rev 4/05
Standard Features
• Size: (L x W x H), 3.15” x 3.15” x 1.50”
(80mm x 80mm x 38mm)
• Airflow: 49.3m3/hour (29 CFM)
• Noise Level: 34 dBA, as measured in free air and with the
microphone 1 meter from the air intake side of the fan
• Nominal Operating Voltage: 115 or 230 VAC
• Operating Temperature: -10° C to +70° C
• Storage Temperature: -40° C to +80° C
• Weight: 340 g (0.75 lbs)
• Two bearing systems per fan to improve life and reliability
• Termination: Via two off terminal pins
• Impeller: Black, UL94-VO rated thermoplastic
• Housing: Black, Aluminium construction
• Airflow Direction: Intake over the fan struts
Benefits
• High performance, low cost fan minimising design
and inventory costs
• Tolerance of + or - 10% on input voltage, making the fan
suitable for use worldwide
• Two ball bearing systems per fan, providing high
lifetime reliability
by Comair Rotron