Specific Control & Display Products Product Focus Monitoring, Measurement, Control & Display Counters, Panel Meters, Tachometers and Timers April 2007 Description Page Totalizers Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Count Controls/Preset Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tachometers/Ratemeters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Panel Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Timers/Hour Meters Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Time Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flow Totalizers, Transmitters and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . Special Function Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fusion(R) Integrated Machine Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories and Encoders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 3 16 22 36 51 57 62 63 66 68 71 74 79 82 Dimensions, Weights and Ratings Dimensions, weights and ratings given in this Product Guide are approximate and should not be used for construction purposes. Drawings giving exact dimensions are available upon request. All listed product specifications and ratings are subject to change without notice. Photographs are representative of production units. Terms and Conditions All orders accepted by Eaton are subject to the general terms and conditions as set forth in Sellers Policy 25-000. Other Cutler-Hammer(R) Products Eaton's electrical business is a leader in the development and manufacturing of power distribution equipment, electrical control products and advanced industrial automation solutions. For more information on Cutler-Hammer products and services, visit our Web site at www.eaton.com. WARNING The installation and use of Cutler-Hammer products should be in accordance with the provisions of the U.S. National Electrical Code and/or other local codes or industry standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment. PG05400001E For more information visit: www.eaton.com 1 2 Counters, Panel Meters, Tachometers and Timers Totalizers April 2007 Product Family Overview Introduction Limit Switch Totalizers are used in a wide variety of applications where accurate totals are needed. Typical applications include counting the number of parts produced, amount of material used, or the number of machine cycles occurring. Totalizers are the simplest and most common type of counter. As an added bonus, some models can perform both totalizing and ratemeter functions. T/R Durant (R) RST Finished Parts Limit Switch Application Example Manufacturing Process Parts are fed into a machine or process, an operation is performed, and the finished parts exit the machine or process. The subtract totalizer is used to indicate the number of parts in process. Raw Parts Application Example Totalizer Product Family Overview Table 1. Product Family Overview Product Family E5-024-C Characteristics Typical Applications Panel Cutout in Inches (mm) Page Number Non-replaceable battery (min. 8-yr. life) Compact, low cost and high efficiency 8-Digit LCD totalizers Manual or electrical reset Various counting modes/inputs Compact device with bright, LED display Multiple functions available: count, time, rate, multifunction, double-function 24V DC Power 0.870 x 1.772 (22 x 44) 22 0.870 x 1.772 (22 x 44) 24 Economical, multifunction display Large, LED characters AC or DC power options Large, easy-to-read display Position display Motor/pulley RPM 1.772 x 1.622 (45 x 92) 27 Portable/mobile/remote flow monitoring 1.299 x 2.677 (e.g. sewer pumping, pesticide application) (33 x 68) Position display, RPM Length measurement (e.g. carpet, cable) 25 28 Replacement for mechanical counters Transaction counting Parts counting Position indication or measurement Count, measure, time where small package and easy-to-read display required Position display Motor/pulley RPM E5-_24-E E5-496-E Courier Replaceable lithium battery 8-digit, high-visibility LCD display Optional backlighting Various input options available 6-digit, super bright LED display Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls Eclipse Length measurement and control 1.772 x 1.622 (45 x 92) Flow monitoring and control Process monitoring and display Voltage and current monitoring and display 8-digit, high-visibility, 2-line LCD display User-configurable control inputs Highly flexible control/display Flow control where simultaneous total and 2.667 x 2.667 rate display are required (68 x 68) Cut-to-length and other simple processes where flexibility of inputs/outputs required 34 Bright LED display w/14 mm characters Simple configuration with 14-button tactile 2.667 x 5.433 (68 x 138) 30 Various Mounting Configurations 16 Various Mounting Configurations 3 Ambassador keypad Many different versions fit almost any President application Various price, voltage and size ranges for different duty cycles and environments Long life and always readable display Electromechanical Various size ranges for different duty cycles and environments No power supply needed Long life and always readable display Cut-to-length machinery with batching Parts batching/palletizing Die press positioning control Applications where parameter changes are required Coin-operated equipment Gaming machines Printing presses Secondary machines (e.g. punch press) Winding and spooling equipment Position display Mechanical piece/cycle counting Mechanical For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Stroke April 2007 3 X Series/Pushbutton Desk Tally -- Durant(R) Technical Data and Specifications Contents Description Page Mechanical Totalizers -- Stroke X Series/Pushbutton Desk Tally . . . . . . . . . . . . 3 CS Series . . . . . . . . . . . . . . 4 H Series . . . . . . . . . . . . . . . 5 D Series . . . . . . . . . . . . . . . 6 Figures: 4 or 5 Speed: 1000 cpm Shaft: 0.125" (3.2 mm) diameter stainless steel Drive: Drive parts of nylon Bearings: Oil-less, maintenance free Finish: Black frame and Cycolac black cover Stroke Operation: 33 minimum; 58 maximum Figure Size: 3/16 inch (4.8 mm) high, white-on-black background Reset: Knob Operating stroke angles apply to forward stroke counter only. Check factory for angles of reverse stroke counter. Product Selection Table 2. Product Selection -- X Series Stroke Counters and Pushbutton Desk Tallies Cat. No. 5-X-1-1-R Product Description Model X Series is a dustproof and rustproof series of counters for light and medium-duty work. They are sound and durable, requiring a minimum of driving effort, and have been especially designed for incorporation as integral parts of a variety of machines and equipment. Pushbutton Desk Tally No. of Figures Drive Reset Mounting Catalog Number Order Number 4 5 4 L.H. Lever L.H. Lever R.H. Lever Knob Knob Knob Base Base Base 4-X-1-1-L 5-X-1-1-L 4-X-1-1-R 40263400 40272401 40263401 5 4 4 R.H. Lever L.H. Lever R.H. Lever Knob Knob Knob Base Base Base 5-X-1-1-R 4-X-1-1-L-REV 4-X-1-1-R-REV 40272402 40263403 40263402 5 5 4 4 L.H. Lever R.H. Lever Push Bar Pushbutton Knob Knob Knob Knob Base Base Base Base 5-X-1-1-L-REV 5-X-1-1-R-REV 4-X-2 4-X-2-A 40272400 40272403 21619400 33245400 * Reverse stroke. When Ordering Specify To determine a model number from the Product Selection table for Model X Series Stroke Counters and Pushbutton Desk Tallies, consider: Number of figures Drive Dimensions C 1.38 (35.1) D 0.14 (3.6) Pre Stroke 0.97 1.20 1.44 (24.6) (30.6) (36.5) 0.12 (3.2) 0.53 (13.5) 12 5 45 5 0.44 (11.1) A B 0.89 (22.6) 58 5 Index Stroke Dia. 0.093 (2.36) Total Stroke Figure 1. X Series -- Approximate Dimensions in Inches (mm) Ruggedly constructed counters with feather-touch pushbutton operation and maximum readability. Specifications and dimensions are basically the same as the X Series counters. Will give long and accurate service in areas requiring hand counting or during hand operations. Table 3. X Series -- Approximate Dimensions in Inches (mm) Model A B C D 4-X-1-1_ 5-X-1-1_ 1.86 (47.2) 2.16 (54.8) 2.76 (70.2) 3.06 (77.8) 0.62 (15.7) 0.81 (20.6) 0.89 (22.6) 0.95 (24.1) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Stroke 4 April 2007 CS Series -- Durant(R) Product Selection Table 4. Product Selection -- CS Series Stroke Counters Cat. No. 4-CS-1-1-R No. of Figures Drive Reset Mounting Catalog Number Order Number 4 5 R.H. Lever R.H. Lever Wing Nut Wing Nut Base Base 4-CS-1-1-R 5-CS-1-1-R 31062400 31062401 5 5 5 L.H. Lever R.H. Lever L.H. Lever Wing Nut Wing Nut Wing Nut Base Base Base 5-CS-1-1-L 5-CS-1-1-R-RP 5-CS-1-1-L-RP 31061401 01464400 00445400 Product Description Model CS Series of small, compact, top reading stroke counters is designed for use in most industrial applications. These counters are ruggedly built and feature a single casting case, which assures great rigidity and a tight seal for working parts. Technical Data and Specifications Figures: 4 or 5 Speed: 600 cpm Stroke Operation: 37-1/2 minimum; 75 maximum Shaft: 0.25" (6.4 mm) diameter stainless steel, rustproof Drive: Accurately machined, hardened steel parts Bearings; Oil-less, maintenance free Figure Size: 11/32" (8.7 mm) high, black-on-white background Reset: Contoured wing nut Finish: Black frame Operating Lever; Cast zinc. Adjustable to any position. Furnished complete with pull spring. * Special Feature: Rustproof. When Ordering Specify To determine a model number from the Product Selection table for Model CS Series Stroke Counters, consider: Number of figures Drive lever Dimensions Dia. 0.156 4 Mtg. Holes 0.73 (18.6) D 0.47 (11.9) 0.42 (10.7) Stroke 37.5 Min. - 75 Max. 0.50 (12.7) 0.92 (23.4) 0.56 (14.3) 1.25 (31.8) 1.19 (30.2) A B C Dia. 0.25 (6.35) 1.00 (25.4) 2.09 1.34 (53.1) (34.1) 0.22 (5.6) 1.25 (31.8) 1.69 (42.9) Figure 2. CS Series -- Approximate Dimensions in Inches (mm) Table 5. CS Series -- Approximate Dimensions in Inches (mm) Model A B C D 4-CS-1_ 5-CS-1_ 3.12 (79.2) 3.62 (91.9) 3.50 (88.9) 4.00 (101.6) 4.03 (102.3) 4.53 (115.0) 1.87 (47.6) 2.38 (60.5) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Stroke April 2007 5 H Series -- Durant(R) Product Selection Table 6. Product Selection -- H Series Stroke Counters Cat. No. 5-H-1-1-R Product Description Model H Series heavy-duty counters are designed for hard usage and long, trouble-free service. They are highspeed, streamlined counters constructed of the highest quality materials and drive shaft moves in oilless bearings. All shafts are stainless steel. The drive action is designed with overstroke so counter does not bottom, increasing life and permitting easier installation. The sturdy cover is stamped steel, locked into position on a heavy, die-cast base of a special alloy. A heavy steel mounting plate is adjustable for either bottom or back mounting. Model "H" has earned the reputation of being the "work horse" of industrial counters. Wing nut or tamper-proof reset lock which requires a key to reset the counter, guarding against unauthorized resetting or tampering. No. of Figures Drive Reset Mounting Catalog Number Order Number 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 R.H. Lever L.H. Lever R.H. Lever L.H. Lever Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-H-1-1-R 5-H-1-1-L 5-H-1-1-R-REV 5-H-1-1-L-REV R.H. Lever L.H. Lever R.H. Lever L.H. Lever R.H. Lever R.H. Lever R.H. Lever L.H. Lever R.H. Trip Arm R.H. Trip Arm L.H. Trip Arm L.H. Trip Arm Wing Nut Wing Nut Lock Reset Lock Reset Lock Reset Lock Reset Wing Nut Wing Nut Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base Base Base Rear Rear Base Base Base Base 5-H-1-1-R-RP 5-H-1-1-L-RP 5-H-1-2-R 5-H-1-2-L 5-H-1-2-R-RP 5-H-1-2-L-RP 5-H-1-4-R 5-H-1-4-L 40205400 40205401 00597400 00598400 40205404 40205405 40206404 40206405 40206400 40206401 00507400 00508400 5-H-5-A 5-H-5-B 5-H-5-C 5-H-5-D 31049400 31049401 31049402 31049403 5 5 5 5 R.H. Trip Arm R.H. Trip Arm L.H. Trip Arm L.H. Trip Arm Lock Reset Lock Reset Lock Reset Lock Reset Base Base Base Base 5-H-6-A 5-H-6-B 5-H-6-C 5-H-6-D 01533400 01534400 01535400 01536400 Special Feature: Reverse stroke. Special Feature: Rustproof. When Ordering Specify To determine a model number from the Product Selection table for Model H Series Stroke Counters, consider: Number of figures Type of reset (lock or wing nut) Drive lever location (left or right side) Technical Data and Specifications Figures: 5 Speed: 800 cpm Stroke Operation: 37 stroke to count; 60 maximum stroke Shaft: 0.31" (7.9 mm) diameter stainless steel, rustproof Drive: Accurately machined, hardened steel parts; Geneva drive for extra long life Bearings: Oil-less, maintenance free Figure Sizes; 11/32" (8.7 mm) high, black-on-white background Reset: Wing nut or tumbler lock reset Finish: Black frame and cover Operating Lever: Adjustable to any position. Furnished complete with pull spring for attaching. PG05400001E * A C B D Figure 3. Direction Location for 5H5 and 5H6 Dimensions Lock Reset 1.20 (30.6) 0.98 (25.0) C 0.75 (19.1) 2.76 (70.1) 1.80 (45.7) Wing Nut Reset Dia. 0.31 (7.92) A B 0.75 (19.1) 1.0 (25.4) 0.91 (23.0) 1.12 (28.4) 2.25 (57.2) Figure 4. H Series -- Approximate Dimensions in Inches (mm) Table 7. H Series -- Approximate Dimensions in Inches (mm) Model A B C 5 Figure Units 3.95 (100.4) 4.38 (111.3) 2.75 (69.9) For more information visit: www.eaton.com Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Stroke 6 April 2007 D Series -- Durant(R) Product Selection Table 8. Product Selection -- D Series Stroke Counters No. of Figures Drive Reset Mounting Catalog Number Order Number 4 5 6 R.H. Lever R.H. Lever R.H. Lever Wing Nut Wing Nut Wing Nut Base Base Base 4-D-1-1-R 5-D-1-1-R 6-D-1-1-R 34269401 34269402 34269403 4 5 6 L.H. Lever L.H. Lever L.H. Lever Wing Nut Wing Nut Wing Nut Base Base Base 4-D-1-1-L 5-D-1-1-L 6-D-1-1-L 34269405 34269406 34269407 * Cat. No. 5-D-1-1-R When Ordering Specify Product Description Model D Series are medium-duty stroke counters available with 4, 5 or 6 figures that have been designed for general service on small production machines. Although compact, Durant(R) "D" models are sturdily constructed and thoroughly tested for accuracy and efficient operation. To determine a model number from the Product Selection table for Model D Series Stroke Counters, consider: Number of figures Drive lever Dimensions C 0.62 (15.7) Technical Data and Specifications Figures: 4, 5 and 6 Speed: 400 cpm Shaft: 0.25" (6.4 mm) diameter stainless steel, rustproof Drive: Nylon rachet and Delrin drive plate. Right-hand drive standard; left-hand drive available Bearings: Oil-less, maintenance free Figure Size: 1/4" (6.4 mm) high, black-on-white background Reset: Wing nut Finish: Black frame and cover Operating lever: Adjustable to any position. Furnished complete with pull string 1.72 (43.6) 0.50 (12.7) Dia. 0.12 (3.05) 4 Mtg. Holes 1.25 (31.8) A 1.62 (41.3) B 1.87 (47.6) Figure 5. D Series -- Approximate Dimensions in Inches (mm) Table 9. D Series -- Approximate Dimensions in Inches (mm) Model A B C 4-D-1-1_ 5-D-1-1_ 6-D-1-1_ 1.59 (40.4) 1.92 (48.8) 2.26 (57.5) 2.20 (55.9) 2.53 (64.3) 2.87 (73.0) 1.20 (30.6) 1.51 (38.5) 1.83 (46.4) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution April 2007 7 X Series -- Durant(R) Product Selection Contents Description Page Mechanical Totalizers -- Revolution X Series . . . . . . . . . . . . . . . 7 CS Series . . . . . . . . . . . . . . 8 D-7 Series . . . . . . . . . . . . . 9 D-6 Series . . . . . . . . . . . . . 10 HDW Series . . . . . . . . . . . . 11 T Series . . . . . . . . . . . . . . . 12 H Series . . . . . . . . . . . . . . . 13 Table 10. Product Selection -- X Series Revolution Counters No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 4 5 4 5 L.H. L.H. L.H. L.H. Clockwise Clockwise Anti-Clockwise Anti-Clockwise 4 5 4 5 4 5 4 5 4 5 4 5 R.H. R.H. R.H. R.H. Clockwise Clockwise Anti-Clockwise Anti-Clockwise L.H. L.H. L.H. L.H. R.H. R.H. R.H. R.H. Clockwise Clockwise Anti-Clockwise Anti-Clockwise Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Knob Base Base Base Base Base Base Base Base Base Base Base Base Base Base Base Base 4-X-7-1-L-CL 5-X-7-1-L-CL 4-X-7-1-L-AC 5-X-7-1-L-AC 4-X-7-1-R-CL 5-X-7-1-R-CL 4-X-7-1-R-AC 5-X-7-1-R-AC 4-X-7-1-L-CL 5-X-7-1-L-CL 4-X-7-1-L-AC 5-X-7-1-L-AC 40270406 40275404 40270404 40275407 40270407 40275405 40270405 40275406 40270402 40275402 40270400 40275400 40270403 40275403 40270401 40275401 Clockwise Clockwise Anti-Clockwise Anti-Clockwise 4-X-7-1-R-CL 5-X-7-1-R-CL 4-X-7-1-R-AC 5-X-7-1-R-AC * Special Feature: 10:1 ratio. Cat. No. 5-X-7-1-L-CL Clockwise Shaft Rotation Product Description Figures: 4 or 5 Speed -- 1000 cpm in 1:1 ratio; 10,000 cpm in 10:1 ratio for intermittent duty Rotation Direction: Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio -- 1:1 and 10:1 standard in 4-X-7 models 10:1 standard in 5-X-7 models Shaft: 0.125" (3.2 mm) diameter stainless steel; standard length 0.44" (11.1 mm) Bearings: Oil-less, maintenance free Figure Size: 3/16 inch (4.8 mm) high, white-on-black background Reset: Knob Finish: Black frame, Cycolac black cover Drive: Right- or left-hand drive; drive parts of Delrin Ratio Information: 1:1 is one count to each revolution of drive shaft, 10:1 is ten counts to each revolution PG05400001E Anti-clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 6. Top View -- Right-Hand Drive Figure 7. Top View -- Left-Hand Drive Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model X Series Revolution Counters, consider: Number of figures Drive shaft location Ratio Shaft rotation direction Dimensions D C E Dia. 0.12 (3.2) 1.38 (35.1) 0.14 (3.6) 0.97 1.20 1.44 (24.6) (30.6) (36.5) 0.12 (3.2) CL Technical Data and Specifications AC Model X Series are dust- and rust-proof counters designed for small, mediumduty units, accurate, durable and require a minimum of driving effort. They are especially designed for incorporation as integral parts of a variety of equipment that gets severe usage under adverse climatic conditions. Clockwise Shaft Rotation 0.53 (13.5) 0.45 (11.5) 0.44 (11.1) A B Figure 8. X Series -- Approximate Dimensions in Inches (mm) Table 11. X Series -- Approximate Dimensions in Inches (mm) Model A B C D E 4-X-7-1_ 5-X-7-1_ 1.86 (47.2) 2.16 (54.8) 2.76 (70.2) 3.06 (77.8) 0.62 (15.7) 0.81 (20.6) 0.19 (4.8) 0.25 (6.4) 0.89 (22.6) 0.95 (24.1) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution 8 April 2007 CS Series -- Durant(R) Product Selection Table 13. Product Selection -- CS Series Revolution Counters Cat. No. 5-CS-7-1-R-CL Product Description Model CS Series top reading revolution counters are designed for use in most industrial applications. The entire case is a single casting. This provides greater rigidity, tighter seal of working parts and more streamlined contour. The unit is compact, rugged and features a flush mounted window to assure greater visibility. No. of Drive Figures Rotation Reset Mounting Catalog Number Order Number 5 5 5 5 L.H. R.H. L.H. R.H. Clockwise Clockwise Anti-Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-CS-7-1-L-CL 5-CS-7-1-R-CL 5-CS-7-1-L-AC 5-CS-7-1-R-AC 31060408 31060409 31060410 31060411 5 4 5 5 4 L.H. R.H. R.H. L.H. R.H. Clockwise Clockwise Clockwise Anti-Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base Base 5-CS-7-1-L-CL 4-CS-7-1-R-CL 5-CS-7-1-R-CL 5-CS-7-1-L-AC 4-CS-7-1-R-AC 00440400 31057401 00441400 00442400 31057403 5 4 4 5 5 R.H. R.H. & L.H. R.H. & L.H. R.H. & L.H. R.H. & L.H. Anti-Clockwise Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut None None None None Base Base Base Base Base 5-CS-7-1-R-AC 4-CS-7-3-CL 4-CS-7-3-AC 5-CS-7-3-CL 5-CS-7-3-AC 00443400 31057408 31057409 31057410 31057411 Special Feature: 10:1 ratio. Special Feature: 10:1 ratio, non-reset, double shaft. Anti-clockwise Shaft Rotation Clockwise Shaft Rotation Technical Data and Specifications Figure 9. Top View -- Right-Hand Drive Figures: 4 or 5 Speed: 600 cpm in 1:1 ratio Rotation Direction: Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio: 1:1 standard Shaft: 0.25" (6.4 mm) diameter stainless steel; standard length 1" (25.4 mm) Drive: Spur gear Bearings: Oil-less, maintenance free Figure Size: 11/32 inch (8.7 mm) high, black-on-white background Reset: Contoured wing nut Finish: Black frame * Figure 11. Top View -- Right-Hand Drive Clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 10. Top View -- R.H. and L.H. Drive Figure 12. Top View -- R.H. and L.H. Drive Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model CS Series Revolution Counters, consider: Number of figures Drive shaft location Ratio Shaft rotation direction Dimensions Dia. 0.156 (3.96) 4 Mtg. Holes D 0.73 (18.6) 0.42 (10.7) 0.50 (12.7) 0.92 (23.4) Dia. 0.25 (6.4) 2.09 (53.1) 1.34 (34.1) Table 12. X Series -- Approximate Dimensions in Inches (mm) Model A B C D 4-CS-7_ 3.12 (79.2) 3.62 (91.9) 3.50 (88.9) 4.00 (101.6) 4.03 (102.3) 4.53 (115.0) 1.89 (47.9) 2.38 (60.5) 5-CS-7_ A B C 1.19 (30.2) 0.22 (5.6) 1.00 (25.4) 1.25 (31.8) 1.69 (42.9) 0.56 (14.3) Figure 13. CS Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution April 2007 9 D-7 Series -- Durant(R) Product Selection Table 14. Product Selection -- D-7 Series Revolution Counters Cat. No. 5-D-7-1-L-CL No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 5 5 5 5 L.H. L.H. R.H. R.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-D-7-1-L-CL 5-D-7-1-L-AC 5-D-7-1-R-CL 5-D-7-1-R-AC 31127408 31127405 31127431 31127400 5 5 5 5 L.H. L.H. R.H. R.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise None None None None Base Base Base Base 5-D-7-3-L-CL 5-D-7-3-L-AC 5-D-7-3-R-CL 5-D-7-3-R-AC 31127416 31127412 31127438 31127442 * Product Description Model D-7 Series spur gear end drive units are compact counters that meet a variety of needs. Accurate, dependable and moderately prices, they are especially recommended for braiding machines, low-speed coil winders, wire measuring equipment and all mediumduty revolution applications. Technical Data and Specifications Figures: 5 standard Speed: Up to 800 cpm in 1:1 ratio Rotation Direction: Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio: 1:1 standard Shaft: 0.31" (7.9 mm) diameter stainless steel; 0.66" (16.7 mm) right-hand drive, 0.63" (15.9 mm) left-hand drive Drive: Right- or left-hand spur gear drive Bearings: Oil-less, maintenance free Figure Size: 1/4 inch (6.4 mm) high, black-on-white background Finish: Black frame and cover Reset: Wing nut or non-reset Clockwise Shaft Rotation Clockwise Shaft Rotation Anti-clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 14. Top View -- Right-Hand Drive Figure 15. Top View -- Left-Hand Drive Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model D-7 Series Revolution Counters, consider: Number of figures Shaft rotation direction Shaft drive Reset or Non-reset Dimensions 1.51 (38.5) 0.12 (3.2) 0.75 (19.0) 1.17 (29.8) Dia. 0.31 0.50 (7.9) (12.7) Dia. 0.120 (3.05) 4 Mtg. Holes 1.92 (48.8) 0.50 (12.7) 2.53 (64.3) 1.72 (43.6) 1.62 (41.3) 0.78 (19.8) Figure 16. D-7 Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution 10 April 2007 D-6 Series -- Durant(R) Product Selection Table 15. Product Selection -- D-6 Series Revolution Counters Cat. No. 5-D-6-1-AC Product Description Model D-6 right-angle worm drive counters are ruggedly designed for high speeds on light duty applications. Small "D" counters are easily adapted as accessory equipment on machinery where right-angle drive is desired to permit full view reading of the counter. No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 5 5 5 5 Front & Rear Front & Rear Front & Rear Front & Rear Anti-Clockwise Anti-Clockwise Clockwise Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-D-6-1-AC 6-D-6-1-AC 5-D-6-1-CL 6-D-6-1-CL 31052401 31052402 31052404 31052405 5 5 5 5 Front & Rear Front & Rear Front & Rear Front & Rear Anti-Clockwise Anti-Clockwise Clockwise Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-D-8-1-AC 6-D-8-1-AC 5-D-8-1-CL 6-D-8-1-CL 40187401 40187402 40187417 40187418 5 5 5 5 Front & Rear Front & Rear Front & Rear Front & Rear Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-D-9-1-CL 5-D-9-1-AC 5-D-90-1-CL 5-D-90-1-AC 40187404 40187410 40187414 40187408 Special Feature: Measuring wheels and brackets available for lineal measurement in Feet. Special Feature: Measuring wheels and brackets available for lineal measurement in Yards and 1/8ths. Special Feature: Measuring wheels and brackets available for lineal measurement in Yards. Technical Data and Specifications Figures: 5 Speed: Up to 1500 cpm in 1:1 ratio Rotation Direction: Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio: 1:1 standard Shaft: 0.31" (7.9 mm) diameter stainless steel; 1.25" (31.8 mm) length standard Drive: Worm drive Bearings: Oil-less, maintenance free Figure Size: 1/4" (6.4 mm) high, black-on-white background Finish: Black frame and cover Reset: Wing nut * Clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 17. Top View of Counter Figure 18. Top View of Counter Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model D-6 Series Revolution Counters, consider: Shaft rotation direction Dimensions 1.16 (29.4) A 1.23 (31.4) Reading Line 0.84 (21.4) Dia. 0.144 (3.66) 4 Mtg. Holes Dia. 0.31 (7.93) 0.12 0.34 2.0 (3.0) (8.7) (50.8) 2.81 (71.4) 0.50 (12.7) 0.66 (16.7) 0.75 (19.0) 3.19 (81.0) 1.62 (41.3) 2.00 (50.8) 3.62 (92.1) Figure 19. D-6 Series -- Approximate Dimensions in Inches (mm) A = 1.85 (46.9) for 6 figures and 1.53 (38.9) for 5 figures. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution April 2007 11 HDW Series -- Durant(R) Product Selection Table 16. Product Selection -- HDW Series Revolution Counters HDW Series Revolution Counter No. of Figures Drive Rotation Reset 5 5 5 5 R.H. R.H. L.H. L.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Mounting Catalog Number Order Number Base Base Base Base 5-HDW-7-1-R-CL 5-HDW-7-1-R-AC 5-HDW-7-1-L-CL 5-HDW-7-1-L-AC 31050400 31050401 31050402 31050403 Mounting plate is adjustable for base or back mounting. Product Description Model HDW Series are high speed, end drive revolution counters that have the rugged features of all Durant "H" counters, with the addition of double worm drive that produces speeds up to 2000 cpm. Lightweight precision molded wheels reduce centrifugal force and eliminate slipping. They are particularly recommended for quick starting and stopping machines, such as coil winders and wire measuring or reeling equipment and on applications where continuous high speed measuring is required. Technical Data and Specifications Figures: 5 Speed: Up to 2000 cpm Rotation Direction: Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio: 1:1 only Shaft: 0.31" (7.9 mm) diameter stainless steel; standard length 2" (50.8 mm) Drive: Right- or left-hand drive Bearings: Oil-less, maintenance free Figure Size: 11/16 inch (17.5 mm) high, white-on-black background Reset: Wing nut or tumbler lock reset Finish: Black frame and cover * Clockwise Shaft Rotation Clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 20. Top View -- Right-Hand Drive Anti-clockwise Shaft Rotation Figure 21. Top View -- Left-Hand Drive Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model HDW Series Revolution Counters, consider: Shaft drive Shaft rotation direction Dimensions 0.75 (19.1) 2.75 (69.9) 0.98 (25.0) 0.96 (24.4) 2.00 (50.8) 2.76 (70.1) 1.80 (45.7) 4.51 (100.3) 4.94 (111.3) Dia. 0.312 (7.9) Dia. 0.22 (5.59) 4 Mtg. Holes 0.90 (22.9) 0.34 (8.5) 1.12 (28.4) 2.25 (57.2) Figure 22. HDW Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution 12 April 2007 T Series -- Durant(R) Product Selection Table 17. Product Selection -- T Series Revolution Counters Cat. No. 5T61CL Product Description No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number 5 5 5 5 Top & Bottom Top & Bottom Top & Bottom Top & Bottom Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Back Back Back Back 5T61CL 5T61AC 5T81CL 5T81AC 40342400 40342401 40179402 40179403 5 5 5 5 Top & Bottom Top & Bottom Top & Bottom Top & Bottom Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Back Back Back Back 5T91CL 5T91AC 5T901CL 5T901AC 40179408 40179409 40179406 40179407 Special Feature: Measuring wheels and brackets available for lineal measurement in Feet. Special Feature: Measuring wheels and brackets available for lineal measurement in Yards and 1/8ths. Special Feature: Measuring wheels and brackets available for lineal measurement in Yards. Model T Series worm drive revolution counters are sturdy, high speed instruments used on many heavy machines, engines or motors. Variety of drive permits direct connection. Suitable for panel mounting. Technical Data and Specifications Figures: 5 standard Speed: 1500 cpm in 1:1 ratio Rotation Direction: Clockwise or anti-clockwise determined top looking down Ratio: 1:1 standard Shaft: 0.31" (7.9 mm) diameter stainless steel; standard extends 2" (50.8 mm) top and bottom Drive: Hobbed steel and bronze worm gearing; subtracts when reversed Bearings: Oil-less, maintenance free Figure Size: 11/32 inch (8.7 mm) high, black-on-white background Reset: Left-hand wing nut standard Finish: Black frame and face plate * Clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 23. Top View of Counter Figure 24. Top View of Counter Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model T Series Revolution Counters, consider: Shaft rotation direction Dimensions 1.38 (35.1) 0.75 (19.1) 0.62 (15.9) 0.24 (6.2) 2.97 (75.4) 0.47 (11.9) 2.38 (60.5) 1.87 (47.6) 1.41 (35.7) 1.36 (34.5) 2.19 (55.6) 4.50 (114.2) 0.25 (6.4) 1/4-20 UNC-2B 4 Mtg. Holes 5.00 (127.0) Figure 25. T Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution April 2007 13 H Series -- Durant(R) Product Selection Table 18. Product Selection -- H Series Revolution Counters Cat. No. 5-H-7-1-R-CL Product Description Model H Series are heavy-duty, end drive revolution counters designed for industrial use; suitable for speeds up to 800 cpm. They are available with either right- or left-hand drive, and with wing nut reset. No. of Figures Drive Rotation Reset 5 5 5 5 L.H. L.H. R.H. R.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise 5 5 5 5 L.H. L.H. R.H. R.H. 5 5 5 5 5 5 5 5 Technical Data and Specifications Figures: 5 Speed: Up to 800 cpm in 1:1 ratio Rotation Direction: Clockwise or anti-clockwise when viewed from right-hand end of counter Ratio: 1:1 standard Shaft: 0.31" (7.9 mm) diameter stainless steel; standard length 2" (50.8 mm) Drive: Right- or left-hand drive Bearings: Oil-less, maintenance free Figure Size: 11/32 inch (8.7 mm) high, white-on-black background Reset: Wing nut Finish: Black frame and cover Mounting Catalog Number Order Number Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-H-7-1-L-CL 5-H-7-1-L-AC 5-H-7-1-R-CL 5-H-7-1-R-AC 00509400 00510400 00513400 00514400 Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-H-8-1-L-CL 5-H-8-1-L-AC 5-H-8-1-R-CL 5-H-8-1-R-AC 00601400 00602400 00605400 00606400 L.H. L.H. R.H. R.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-H-9-1-L-CL 5-H-9-1-L-AC 5-H-9-1-R-CL 5-H-9-1-R-AC 00619400 00620400 00617400 00618400 L.H. L.H. R.H. R.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise Wing Nut Wing Nut Wing Nut Wing Nut Base Base Base Base 5-H-9-0-1-L-CL 5-H-9-0-1-L-AC 5-H-9-0-1-R-CL 5-H-9-0-1-R-AC 00611400 00612400 00609400 00610400 * Mounting plate is adjustable for base or back mounting. Special Feature: Measuring wheels and brackets available for lineal measurement in Feet. Special Feature: Measuring wheels and brackets available for lineal measurement in Yards and 1/8ths. Special Feature: Measuring wheels and brackets available for lineal measurement in Yards. Clockwise Shaft Rotation Clockwise Shaft Rotation Anti-clockwise Shaft Rotation Figure 26. Top View -- Right-Hand Drive Clockwise Shaft Rotation Figure 27. Top View -- R.H. and L.H. Drive Anti-clockwise Shaft Rotation Figure 28. Top View -- Left-Hand Drive Anti-clockwise Shaft Rotation Figure 29. Top View -- R.H. and L.H. Drive Note: When shaft is turned in the reverse direction of rotation, the counter will subtract. When Ordering Specify To determine a model number from the Product Selection table for Model H Series Revolution Counters, consider: Drive shaft location Shaft rotation direction Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 14 Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Revolution April 2007 H Series -- Durant(R) Dimensions 2.75 (69.9) 0.98 (25.0) 2.00 (50.8) 2.76 (70.1) 0.91 (23.0) 1.80 (45.7) 3.95 (100.4) 4.38 (111.3) Dia. 0.312 (7.92) Dia. 0.220 4 Mtg. Holes 0.34 (8.5) 1.12 (28.4) 2.25 (57.2) Figure 30. H Series -- Approximate Dimensions For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Mechanical Totalizers -- Can Counters April 2007 15 HF Series -- Durant(R) Product Selection Table 19. Product Selection -- HF Series Can Counters No. of Figures Drive Rotation Reset Mounting Catalog Number Order Number Back Back Back Back 6-HF-4-1-R-CL 6-HF-4-1-R-AC 6-HF-4-2-R-CL 6-HF-4-2-R-AC 40181402 40181403 40181406 40181407 Back Back Back Back 6-HF-3-1-R-CL 6-HF-3-1-R-AC 6-HF-3-2-R-CL 6-HF-3-2-R-AC 40182402 40182403 40182406 40182407 * Star Wheel Diameter -- 6-pt., 5.25" (133.4 mm) 6 6 6 6 Clockwise Anti-Clockwise Clockwise Anti-Clockwise R.H. R.H. R.H. R.H. Wing Nut Wing Nut Key-Lock Key-Lock Star Wheel Diameter -- 4-pt., 7.375" (187.3 mm) Cat. No. 6-HF-4-1-R-CL 6 6 6 6 Product Description Model HF Series can counters are designed for use on can filling, labeling and sealing machines and conveyors to count various sizes of cans. Gear box on counter is changeable to any one of four positions, giving great flexibility of installation. Adjustable tension screw prevents spinning and assures peak accuracy. R.H. R.H. R.H. R.H. Clockwise Anti-Clockwise Clockwise Anti-Clockwise Special Feature: 6:1 ratio. Special Feature: 4:1 ratio. When Ordering Specify To determine a model number from the Product Selection table for Model HF Series Can Counters, consider: Type of reset Rotation direction of star wheel Positions Position 1 Position 2 Technical Data and Specifications CL AC Figures: 6 Figure Sizes: 11/32 inch (8.7 mm) high, white-on-black background Reset: Wing nut or key-lock Wing Nut Wing Nut Key-Lock Key-Lock AC CL Position 3 CL CL AC Position 4 AC Figure 31. HF Series -- Can Counter Positions Note: All Model HF Series counters are shipped from the factory in position 1. The instruction sheet that accompanies each counter provides directions for moving the star wheel to position 2, 3 or 4. Dimensions 1.20 (30.6) 0.75 (19.1) 4.51 (114.6) 2.13 (54.0) 1.62 (41.1) 3.53 (89.7) 3.00 (76.2) 8.18 (207.9) Wing Nut Reset Key Lock Reset 1.41 (35.8) 2.47 (62.7) 6.20 (157.6) Dia. 0.196 (4.98) 4 Mtg. Holes 3.00 (76.2) 3.73 (94.8) 0.81 (20.6) 2.06 (52.4) 3.00 (76.2) Figure 32. HF Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Electromechanical Totalizers 16 April 2007 Micro Display Counter -- Eaton Technical Data and Specifications Contents Description Electric Counters Micro Display Courier . . . . SE Series . . . . . . . . . . . . . . . MF Series . . . . . . . . . . . . . . RMF Series . . . . . . . . . . . . . ME Series . . . . . . . . . . . . . . Page 16 17 18 19 20 Electrical Connections: Built-in counter, flying leads, AWG 22, approx. 5.9 Inch (150 mm) Power consumption at 68F (20C) and nominal voltage -- At 25 lmp/s: Approx. 250 mW Rated Voltage: 12V DC 10% Counting Frequency: 25 lmp/s Pulse Duration: Min. 20 mS Pulse Interval: Min. 20 mS Cycle Duration Factor: 100% Number of Digits: 7 Counting System: Adding Height of Figures: 0.05 x 0.16 Inch (1.2 x 4 mm) Optical Color of Figures: White-on-black Reset: No reset Ambient Temperature: 14 to 140F (-10 to 60C) Mounting Position: Any Operating Life: >50x106 pulses Protection: IP65 (only front side) Housing: Clear plastic Weight: 0.53 - 0.71 oz (15 - 18 g) Product Selection Table 20. Product Selection -- Micro Display Counter Cat. No. 7-Y-3013PM-401 Features 7-digit micro adding counter High shock resistance Low power consumption; suitable for battery consumption Small dimensions Large optical figures Different viewing possibilities Flush mount with integrated spring clip Protection IP65 Stores value also at power failure Long service life Standards and Certifications cRU(R)us Certified CE Marked Description Catalog Number Micro Display Counter 7-Y-3013PM-401 * Dimensions 0.08 (2) 0.04 (1.1) 0.51 x 1.18 (13 x 29.9) 1.26 (32) Rmax 0.02 (0.5) 0.59 (15) 0.12 (3) Max. 0.59 (15) 1.18 +0.01 (30 +0.3) 0.51 +0.02 (13 +0.5) 1.29 (32.7) Figure 33. Micro Display Counter -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Electromechanical Totalizers 17 April 2007 SE Series Product Selection Table 21. Product Selection -- SE Series Electromechanical Counters Description Order Number Bottom Mount Sub-miniature 12V DC Bottom Mount Sub-miniature 24V DC Bottom Mount Sub-miniature 120V AC Bottom Mount Sub-miniature 240V AC 6-Y-41610-401-SE 6-Y-41610-402-SE 6-Y-41610-406-SE 6-Y-41610-407-SE 41610401 41610402 41610406 41610407 Base Mount Sub-miniature 12V DC Base Mount Sub-miniature 24V DC Base Mount Sub-miniature 120V AC Base Mount Sub-miniature 240V AC 6-Y-41611-401-SE 6-Y-41611-402-SE 6-Y-41611-406-SE 6-Y-41611-407-SE 41611401 41611402 41611406 41611407 Top Mount Sub-miniature 12V DC Top Mount Sub-miniature 24V DC Top Mount Sub-miniature 120V AC Top Mount Sub-miniature 240V AC 6-Y-41612-401-SE 6-Y-41612-402-SE 6-Y-41612-406-SE 6-Y-41612-407-SE 41612401 41612402 41612406 41612407 Panel Mount Sub-miniature 12V DC Panel Mount Sub-miniature 24V DC Panel Mount Sub-miniature 120V AC Panel Mount Sub-miniature 240V AC 6-Y-41613-401-SE 6-Y-41613-402-SE 6-Y-41613-406-SE 6-Y-41613-407-SE 41613401 41613402 41613406 41613407 Special Base Mount Sub-miniature 12V DC Special Base Mount Sub-miniature 24V DC Special Base Mount Sub-miniature 120V AC Special Base Mount Sub-miniature 240V AC 6-Y-41622-401-SE 6-Y-41622-402-SE 6-Y-41622-406-SE 6-Y-41622-407-SE 41622401 41622402 41622406 41622407 Special Top Mount Sub-miniature 12V DC Special Top Mount Sub-miniature 24V DC Special Top Mount Sub-miniature 120V AC Special Top Mount Sub-miniature 240V AC 6-Y-41623-401-SE 6-Y-41623-402-SE 6-Y-41623-406-SE 6-Y-41623-407-SE 41623401 41623402 41623406 41623407 Snap-In Mount Sub-miniature 12V DC Snap-In Mount Sub-miniature 24V DC Snap-In Mount Sub-miniature 120V AC Snap-In Mount Sub-miniature 240V AC 6-Y-42613-401-SE 6-Y-42613-402-SE 6-Y-42613-406-SE 6-Y-42613-407-SE 42613401 42613402 42613406 42613407 * 6-digit Electric Counter Cat. No. 6-Y-41610-401-SE Features Low-cost electromechanical counter Multiple voltage ranges for almost any application Compact with various mounting options Wire leads for electrical connections Standards and Certifications Catalog Number UL Recognized Technical Data and Specifications Figures: 6 Count Speed: 600 cpm Figure Size: 5/32" (4.0 mm) Reset: None Mounting: Base, bottom, top, panel or snap-in Finish: Black, self-extinguishing plastic Power Requirements -- DC: 1.5W, AC: 5.0V Dimensions 1.01 (25.7) 1.31 (33.2) 1.00 (25.4) 10 (254) 1.88 (47.6) 2.19 (55.5) 2.16 (54.9) 0.63 (15.9) (2) #4-40 UNC 28 Bottom Mount 0.69 (17.4) 1.00 (25.4) (4) 0.13 (3.2) Dia. Mounting Holes Panel Cutout 1.43 x 1.13 (36.3 x 28.6) Panel Mount Top Mount (2) #4-40 Mounting Holes 1.75 2.34 (44.5) (59.5) 1.13 (28.6) 1.00 (25.4) 1.06 (26.9) 2.16 (54.9) 10 (254) 1.81 (46.0) 1.44 (36.5) 1.31 (33.2) 0.19 (4.7) Special Base Mount 2.16 (54.9) Special Top Mount Figure 34. SE Series -- Approximate Dimensions in Inches (mm) PG05400001E 2.16 (54.9) 10 (254) 0.14 (3.6) Dia. 1.97 (50) 10 (254) 2.16 (54.9) 10 (254) 0.19 (4.7) Base Mount 1.50 (38.1) 1.80 (45.7) 1.31 (33.2) 2.16 (54.9) 10 (254) 1.52 Mounting Holes (38.7) for #6 FHMS 0.88 (22.2) 1.0 (25.4) (2) #4-40 Mounting Holes For more information visit: www.eaton.com 10 (254) 2.16 (54.9) Panel Cutout 1.70 x 1.33 (43.2 x 33.8) Snap Mount Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing Counters, Panel Meters, Tachometers and Timers Electromechanical Totalizers 18 April 2007 MF Series -- Durant(R) Mounting: Base or panel mount Finish: Black frame and side covers Electrical Connections: 2-wire leads, 9" (229 mm) long, AWG 22 (0.34 mm2), stripped 0.38" (9.5 mm) Power Requirements: 12 watts Coils: Various AC voltages and frequencies can be supplied on special order. Count coils are designed for continuous duty at rated voltage. Product Selection Table 22. Product Selection -- MF Series Electric Counters No. of Figures Voltage Reset Mounting Catalog Number Order Number 7 7 6 6 120 AC 240 AC 120 AC 24 AC Knob Knob Knob Knob Base Base Base Base 7-Y-1-MF-120A 7-Y-1-MF-240A 6-Y-1-MF-120A 6-Y-1-MF-24A 32650400 32650402 32651400 32651402 6 6 7 7 240 AC 230 AC/50 Hz 120 AC 120 AC Knob Knob Knob Non-reset Base Base Panel Panel 6-Y-1-MF-240A 6-Y-1-MF-230A 7-Y-1-MF-PM-120A 7-Y-13-MF-PM-120A 32651403 32651412 32652400 32652402 6 6 6 6 120 AC 24 AC 240 AC 120 AC Knob Knob Knob Non-reset Panel Panel Panel Panel 6-Y-1-MF-PM-120A 6-Y-1-MF-PM-24A 6-Y-1-MF-PM-240A 6-Y-13-MF-PM-120A 32653400 32653402 32653403 32653405 6 6 6 6 240 AC 120 AC 24 AC 240 AC Non-reset Keylock reset Keylock reset Keylock reset Panel Panel Panel Panel 6-Y-13-MF-PM-240A 6-Y-12-MF-PM-120A 6-Y-12-MF-PM-24A 6-Y-12-MF-PM-240A 32653410 32654400 32654403 32654404 7 6 6 7 120 AC 120 AC 240 AC 120 AC Keylock reset Non-reset Non-reset Non-reset Panel Base Base Base 7-Y-12-MF-PM-120A 6-Y-13-MF-120A 6-Y-13-MF-240A 7-Y-13-MF-120A 32655400 32658400 32658402 32659400 Cat. No. 6-Y-1-MF-120A Product Description Model MF Series are shaded pole electric counters with straight AC operation and feature a non-rectified, shaded pole coil designed to withstand transient, high voltage spikes. This feature, combined with a simplified, hinged escapement drive, also eliminates the possibility of mis- counts and greatly adds to the life of the counter. Tallies at speeds up to 750 cpm. Technical Data and Specifications Figures: 6 or 7 Speed: Up to 750 cpm Figure Size: 3/16 inch (4.8 mm) high, white-on-black background Reset: Knob, key or non-reset * UL Recognized. Dimensions Table 23. MF Series -- Approximate Dimensions in Inches (mm) 0.19 (4.8) 4.37 (111.1) 4.00 (101.6) A B Model A B C D E F 6 Figures 7 Figures 1.73 (44.0) 2.02 (51.4) 1.58 (40.0) 1.29 (32.7) 1.73 (43.9) 2.03 (51.6) 2.80 (71.1) 2.50 (63.5) 1.73 (44.0) 2.02 (51.4) 1.12 (28.6) 0.84 (21.2) 5.50 (139.7) 5.12 (130.2) C D 0.19 (4.8) 0.30 (7.5) 0.16 (4.0) 1.62 1.25 (41.3) (31.8) Dia. 0.15 (3.81) 4 Mtg. Holes 2.56 (65.0) 1.75 2.12 (44.5) (54.0) Dia. 0.15 (3.81) 4 Mtg. Holes 0.06 (1.6) 1.25 (31.8) 0.09 (2.4) Panel 2.56 2.09 (65.0) (53.1) 3.68 (93.5) 2.56 (65.0) 0.28 (7.1) 3.31 (84.1) E F 0.87 1.37 (22.2) (34.9) Dia. 0.14 (3.6) 4 Mtg. Holes 0.97 (24.6) #6-32 Top Mount Models Only 4 Mtg. Holes Panel 0.62 (15.7) 0.56 (14.2) 0.12 0.19 (3.0) (4.8) 0.25 (6.3) 3.68 (93.5) Panel Mounted 3.51 x 1.44 (89.3 x 36.5) Panel Opening Panel Mounted with Tumbler Lock 4.62 x 1.44 (117.3 x 36.5) Panel Opening Figure 35. MF Series -- Approximate Dimensions in Inches (mm) For more information visit: www.eaton.com 3.16 (80.2) 2.56 (65.0) 0.62 (15.7) 0.41 (10.3) 0.25 2.09 (6.3) (53.1) 2.56 (65.0) 3.68 (93.5) 0.56 (14.2) Base Mounted Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E Counters, Panel Meters, Tachometers and Timers Electromechanical Totalizers April 2007 19 RMF Series -- Durant(R) Product Selection Table 24. Product Selection -- RMF Series Electric Counters Cat. No. 6-Y-1-RMF-115A Product Description Model RMF Series of electric counters are designed to give accurate counts through a wide range of speeds up to 1000 cpm. It features a strong, silent, fast operating DC electromagnetic drive with a compact, dependable built-in higher capacity rectifier for AC operation. The counter has a minimum of moving parts that never need lubrication under normal operating conditions. Compact and rigid, it continues to operate dependably even when subject to severe shock and vibrations. Entirely enclosed to prevent damage from moisture and dust. Available in 6 or 7 figures. Technical Data and Specifications Figures: 6 or 7 Speed: Up to 1000 cpm Figure Size: 3/16 inch (4.8 mm) high, white-on-black background Reset: Knob, key or non-reset Mounting: Base or panel mount Finish: Black frame and side covers Electrical Connections: 2-wire leads, 9" (229 mm) long, AWG 22 (0.34 mm2), stripped 0.38" (9.5 mm) Power Requirements: 7 watts Coils: Various voltages and frequencies can be supplied on special order. Count coils are designed for continuous duty at rated voltage. No. of Figures Voltage Reset Mounting Catalog Number Order Number 6 6 7 7 7 7 7 7 7 6 6 6 6 6 6 6 7 6 6 7 7 6 6 6 6 6 7 7 7 6 6 24 DC 24 AC 24 DC 115 AC 230 AC 115 AC 115 AC 115 AC 230 AC 115 AC 230 AC 24 AC 230 AC 115 AC 115 AC 230 AC 115 AC 24 AC 24 DC 24 DC 230 AC 24 AC 240 AC 115 AC 115 AC 24 DC 24 AC 24 DC 24 DC 230 AC 24 AC Knob Knob Knob Knob Knob Non-reset Knob Non-reset Knob Non-reset Non-reset Non-reset Knob Knob Keylock reset Keylock reset Keylock reset Keylock reset Keylock reset Keylock reset Keylock reset Knob Knob Knob Non-reset Non-reset Non-reset Non-reset Non-reset Non-reset Non-reset Panel Panel Panel Base Base Base Panel Panel Panel Base Base Base Panel Panel Panel Panel Panel Panel Panel Panel Panel Base Base Base Panel Panel Base Base Panel Panel Panel 6-Y-1-RMF-PM-24D 6-Y-1-RMF-PM-24A 7-Y-1-RMF-PM-24D 7-Y-1-RMF-115A 7-Y-1-RMF-230A 7-Y-13-RMF-115A 7-Y-1-RMF-PM-115A 7-Y-13-RMF-PM-115A 7-Y-1-RMF-PM-230A 6-Y-13-RMF-115A 6-Y-13-RMF-230A 6-Y-13-RMF-24A 6-Y-1-RMF-PM-230A 6-Y-1-RMF-PM-115A 6-Y-12-RMF-PM-115A 6-Y-12-RMF-PM-230A 7-Y-12-RMF-PM-115A 6-Y-12-RMF-PM-24A 6-Y-12-RMF-PM-24D 7-Y-12-RMF-PM-24D 7-Y-12-RMF-PM-230A 6-Y-1-RMF-24A 6-Y-1-RMF-240A 6-Y-1-RMF-115A 6-Y-13-RMF-PM-115A 6-Y-13-RMF-PM-24D 7-Y-13-RMF-24A 7-Y-13-RMF-24D 7-Y-13-RMF-PM-24D 6-Y-13-RMF-PM-230A 6-Y-13-RMF-PM-24A 31013400 31013402 31019400 31025400 31025402 31026400 31026401 31026402 31026410 31039400 31039404 31039407 31066413 31066416 31083403 31083405 31083409 31083411 31083415 31083421 31083427 31155400 31155401 31155402 31155405 31155442 31573400 31573401 33183400 33183404 33183405 * UL Recognized. When Ordering Specify To determine a model number from the Product Selection table for Model RMF Series Electronic Counters, consider: Number of figures Type of reset Voltage Type of mounting Dimensions Refer to Table 23 and Figure 35 on Page 18 for information. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Electromechanical Totalizers 20 April 2007 ME Series -- Durant(R) Product Selection Cat. No. 6-Y-41346-406-ME Product Description Small in size and price, but large in design versatility and model variety is the ME Series of miniature electric counters. Models in most popular AC or DC voltages operate on as little as 3 watts, with the non-reset models measuring only 1 x 1.593 x 2.187 inches (25.4 x 40.5 x 55.5 mm) and weighing just three ounces (85 grams). Available in 4, 6 or 7 figures, the counters feature stainless steel selflubricating shafts, nylatron pinions and a synchronous electromagnetic drive to assure accurate, reliable, long life operation. Designed for mounting flexibility and aesthetic attractiveness, the miniature electric counters are available with three types of mounting and a glare retarding finish Delrin, with crisp easy-to-read numerals set close to a tamper-proof sealed figure window. Standards and Certifications Figures: 4, 6 and 7 Speed: Up to 1000 cpm Figure Size: 3/16 inch (4.8 mm) high Reset: Pushbutton and non-reset Reset Force: Pushbutton models only, 20 oz. (568 grams) maximum Mounting: Base, bottom, panel and plug-in pin Finish: Black self-extinguishing plastic Electrical Connections: Wire leads, 10 inches (254 mm) long, AWG 20, stripped 3/8 inch (9.5 mm), and pin terminals Power Requirements: 3W Coils: Count coils are designed for continuous duty at rated voltage. Panel Mount Wire Leads Table 25. Product Selection -- ME Series Miniature Electric Counters No. of Figures Voltage Mounting Reset Catalog Number Order Number 4 12V DC 24V DC 120V AC 240V AC Bottom Pushbutton 4-Y-41312-401-MEQ 4-Y-41312-402-MEQ 4-Y-41312-406-MEQ 4-Y-41312-407-MEQ 41312401 41312402 41312406 41312407 4 12V DC 24V DC 120V AC 240V AC Base Pushbutton 4-Y-41313-401-MEQ 4-Y-41313-402-MEQ 4-Y-41313-406-MEQ 4-Y-41313-407-MEQ 41313401 41313402 41313406 41313407 4 12V DC 24V DC 120V AC 240V AC Panel Pushbutton 4-Y-41314-401-MEQ 4-Y-41314-402-MEQ 4-Y-41314-406-MEQ 4-Y-41314-407-MEQ 41314401 41314402 41314406 41314407 6 12V DC 24V DC 120V AC 240V AC Bottom Non-reset 6-Y-41119-401-ME 6-Y-41119-402-ME 6-Y-41119-406-ME 6-Y-41119-407-ME 41119401 41119402 41119406 41119407 6 12V DC 24V DC 120V AC 240V AC Base Non-reset 6-Y-41345-401-ME 6-Y-41345-402-ME 6-Y-41345-406-ME 6-Y-41345-407-ME 41345401 41345402 41345406 41345407 6 12V DC 24V DC 120V AC 240V AC Panel Non-reset 6-Y-41346-401-ME 6-Y-41346-402-ME 6-Y-41346-406-ME 6-Y-41346-407-ME 41346401 41346402 41346406 41346407 7 12V DC 24V DC 120V AC 240V AC Bottom Non-reset 7-Y-41238-401-ME 7-Y-41238-402-ME 7-Y-41238-406-ME 7-Y-41238-407-ME 41238401 41238402 41238406 41238407 7 12V DC 24V DC 120V AC 240V AC Base Non-reset 7-Y-41337-401-ME 7-Y-41337-402-ME 7-Y-41337-406-ME 7-Y-41337-407-ME 41337401 41337402 41337406 41337407 7 12V DC 24V DC 120V AC 240V AC Panel Non-reset 7-Y-41349-401-ME 7-Y-41349-402-ME 7-Y-41349-406-ME 7-Y-41349-407-ME 41349401 41349402 41349406 41349407 UL Recognized Technical Data and Specifications Base Mount Wire Leads Bottom Mount Wire Leads * When Ordering Specify When ordering ME Series Miniature Electric Counters, specify Catalog Numbers according to the features selected. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Electromechanical Totalizers April 2007 ME Series -- Durant(R) Dimensions Panel Mounted Bottom Mounting Bottom Mounted Base Mounted Figure 36. ME Series Counter -- Approximate Dimensions Table 26. ME Series Counter -- Approximate Dimensions in Inches (mm) 4 Figure Pushbutton Reset Counters 6 and 7 Figure Non-reset Counters Dimension Inches (mm) Dimension Inches (mm) A B C D E F G H J K L M N P Q R S T 1.00 (25.4) 1.60 (40.6) 2.64 (67.1) 2.19 (55.6) 1.80 (45.7) 1.80 (45.7) 1.40 (35.6) .69 (17.5) 1.88 (47.8) .50 (12.7) .49 (12.4) .94 (23.9) 2.45 (62.2) 2.45 (62.2) .45 (11.4) .63 (16.0) .19 (4.8) .68 (17.3) A B C D E F G H J K L M N P Q R S T 1.00 (25.4) 1.60 (40.6) 2.38 (60.5) 2.19 (55.6) 1.80 (45.7) 1.80 (45.7) 1.40 (35.6) .69 (17.5) 1.88 (47.8) .50 (12.7) .49 (12.4) .94 (23.9) 2.19 (55.6) 2.19 (55.6) .45 (11.4) .63 (16.0) .19 (4.8) .88 (22.4) Table 27. Recommended Panel Mount Cut-Outs in Inches (mm) 4 Figure Counters 6 and 7 Figure Counters Pushbutton Reset Non-reset 1.72 x 1.11 (43.7 x 28.2) 1.72 x 1.11 (43.7 x 28.2) PG05400001E For more information visit: www.eaton.com 21 Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 22 April 2007 1/32 DIN LCD -- Totalizers Standards and Certifications Contents Description Electronic Totalizers 1/32 DIN LCD -- Totalizers . . . . . . . . . . . . . . 1/32 DIN LED Multifunction Totalizer/ Timer/Ratemeter . . . . . . . . Courier Series . . . . . . . . . . . 1/8 DIN LED Multifunction Totalizer/ Timer/Ratemeter . . . . . . . . Eclipse Series . . . . . . . . . . . President Series . . . . . . . . . Ambassador Series . . . . . . Page 22 24 25 Technical Data and Specifications 27 28 30 34 Cat. No. E5-024-C0400 Features Low price and high efficiency Large 8-digit LCD display, height of the figures 0.31 Inch (8 mm) Various counting modes like up/ down differential and phase discriminator counting, also with pulse doubling for connection with incremental encoders High voltage input for 10 - 260V AC/DC voltage pulses IP65 Screw terminals, RM 5 mm Lifetime of the battery approximately 8 years Locking of the reset key Operating temperature 14 to 140F (-10 to 60C) All version of positive or negative counting edge Filter function for bounce-free counting with mechanical contacts UL Recognized CE Marked Power Supply: Non-replaceable lithium battery (lifetime approximately 8 years at 68F (20C) Display: LCD, 8-digits, height of the figures 0.31 Inch (8 mm) Mode: Adding or subtracting (selectable), counting direction, differential counting or phase discriminator single or dual evaluation (selectable) Display Range: -9999999 - 99999999, with overflow display Reset: Manual and electrical Interference Emissions: EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions) Housing; Dark gray RAL 7021 Operating Temperature: 14 to 131F (-10 to 55C) Ambient Temperature: 14 to 140F (-10 to 60C) Storage Temperature: -4 to 158F (-20 to 70C) Protection: IP65 (from front) Weight: Approx. 1.76 oz (50 g) Counting Inputs -- Counting input of the DC version, max. 30V DC - Slow counting input, max. 30 Hz (NPN) - Fast counting input, max. 12 kHz (PNP) - Switching Level -- NPN: Low 0 - 0.7V, High 3 - 30V DC PNP: Low 0 - 0.7V, High 4 - 30V DC For more information visit: www.eaton.com Counting Input of the High Voltage Versions: 10 - 260V AC/DC - Counting Input: Optocoupler input, max. 30 Hz - Min. Pulse Time: 16 mS - Switching Level-- Low: 0 - 2V AC/DC High: 10 - 260V AC/DC Counting Direction Switching (only DC versions) -- Contact input, open collector NPN (switching at 0V DC) Switching level, NPN -- Low, 0 - 0.7V, High 3 - 5V DC Reset Input (only DC and High Voltage) -- Minimum pulse time, DC: 50 mS; high voltage: 16 mS Contact input NPN -- - Low: 0 - 0.7V - High: 3 - 30V DC High voltage input, 10 - 260V AC/DC Electrical Reset Key Locking (for DC and AC) -- Contact input, open collector NPN (switching at 0V) Switching level, NPN -- Low, 0 - 0.7V, High 3 - 5V DC PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 1/32 DIN LCD -- Totalizers Product Selection Table 28. Product Selection -- 1/32 DIN LCD, Totalizers Description Catalog Number * 8-digit LCD Totalizer, Battery Power 0.94 x 1.89 Inch (24 x 48 mm) 10 - 260V Input 0.94 x 1.89 Inch (24 x 48 mm) Count Up/Down 0.94 x 1.89 Inch (24 x 48 mm) E5-024-C0400 E5-024-C0408 E5-024-C0410 Dimensions MAX. 1.89 (19.3) 1.89 (48) 0.94 (24) 572690.43 0.87 x 1.77 (22 x 45) 0.11 (2.8) 1.88 (47.7) 0.12 (3) 1.77 + 0.024 (45 + 0.6) 1.77 + 0.012 (22.2 +0.3) Figure 37. 1/32 DIN LCD, Totalizers -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 23 Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 24 April 2007 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter Immunity to Interference: EN 61 000-6-4/ EN 55011 Class B Emitted Interference: EN 61 000-6-2 Protection: IP65 (from front) Weight: Approx. 5.29 (150 g) Ambient Temperature: 14 to 122F (-10 to 50C) Storage Temperature: -13 to 167F (-25 to 75C) EMC: According to EC EMC directive 89/36/EWG Product Selection Cat. No. E5-024-E0402 Table 29. Product Selection -- 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter Description Catalog Number LED Single Channel Totalizer, 10 - 30V DC Power 0.94 x 1.89 Inch (24 x 48 mm) E5-024-E0402 LED Multifunction Totalizer/Timer/Ratemeter 10 - 30V DC Power 0.94 x 1.89 Inch (24 x 48 mm) E5-424-E0402 LED Double-Function Totalizer/Timer/Ratemeter 10 - 30V DC Power 0.94 x 1.89 Inch (24 x 48 mm) E5-524-E0402 LED Totalizer with Quadrature, 10 - 30V DC Power 0.94 x 1.89 Inch (24 x 48 mm) E5-024-E0432 Features Display counter adding and subtracting Position display Frequency counter/ratemeter Timer Display Range: -199.999 - 999.999 with zero blanking Screw terminal Locking SET-Key Dimensions Standards and Certifications Technical Data and Specifications Supply Voltage: 10 - 30V DC with reverse polarity protection Current Consumption: Max. 50 mA Display: 6-digit red, 7-segment LED display; 0.31 Inch (8 mm) high Data Backup: EEPROM Housing: Dimension 3.78 x 1.89 Inch (96 x 48 mm) according to DIN 43 700; RAL 7021 gray Polarity of Inputs: Programmable, NPN or PNP Input Resistance: Approx. 10 k1 Counting Frequency: 20 kHz, can be damped to 30 Hz, position display max. 11 kHz Resolution: Timer 0.001 sec. Reset Time: 5 mS Level of Inputs -- High: 0.6 x UB - 30V DC Low: 0 - 0.2 x UB [V DC] Octocoupler Output: Max. 30V, 10 mA Error -- Tachometer: <0.1% Timer: <50 ppm 0.87 x 1.77 (22.0 x 45.0) 1.89 (48.0) UL Recognized CE Marked * Max. 0.76 (19.3) Connections: 0.94 (24.0) Panel Cut-Out: 0.87 + 0.01 x 1.77 + 0.02 (22.2 + 0.3 x 45 + 0.6) 0.16 (4.0) 0.26 (6.5) 2.32 (59.0) 2.09 (53.0) 1.10 (28.0) 1.97 + 0.02 (50 + 0.6) 0.98 x 1.97 (25 x 50) 0.98 + 0.02 (25 + 0.5) 0.04 (1.0) Panel Cut-Out 0.16 (4.0) 2.20 (56.0) 1.57 1.26 (40) (32) 1.97 + 0.02 (50 + 0.6) 0.98 x 1.97 (25 x 50) 0.04 (1.0) 1.26 + 0.004 (32 + 0.1) 0.98 + 0.02 (25 + 0.5) 0.16 (4.0) M3 Panel Cut-Out Figure 38. 1/32 DIN LED Multifunction Totalizer/Timer/Ratemeter -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 Courier Series -- Durant(R) Physical Courier Series Features 8-digit totalizer 1/Tau ratemeter Scaling capabilities Remote reset terminal 0.43-inch (10.9 mm) display Front panel reset NEMA 4X CE Marked Technical Data and Specifications Power Internal Battery: 3V, Lithium Life expectancy: 5 years + Replacement Part: 36367-202 Input Impedance: 2k Ohm above 5V DC Voltage Thresholds -- Low: 0 - 1.2V DC High: 2.0 - 28V DC Max. High: 28V DC Count Accuracy Reset Input 100% when operated within specifications DC Common (Terminal 1) Count Inputs Input B (Terminal 2) Low speed input designed for contact closures to DC common Speed: 0 to 20 Hz Min. Low Time: 10 mS Min. High Time: 40 mS Input Impedance: 101k Ohm Voltage Thresholds -- Low: 0 - 0.4V DC High: 2.0 - 28V DC Max. High: 28V DC 10 - 30V DC @ 30 mA max. Note: Derate operating temperature 1C/ Volt above 17V DC. Reverse polarity protected PG05400001E Input A (Terminal 3) High speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed: 0 to 10 kHz Min. Low Time: 80 mS Min. High Time: 20 mS Note: The above times are with a 0 - 5.0V swing. Type: UP counting Digits: 8 Backlight Totalizer Standards and Certifications Operating Temperature: -4 to 158F (-20 to 70C) Storage Temperature: -4 to 158F (-20 to 70C) Operating Humidity: 60% Non-condensing. Weight: 2.2 oz. (62 g) net. Display Size: 0.43" (10.9 mm) high Front Panel Rating: NEMA 4X when mounted with gasket provided Case Material: Cycolac X-17 For more information visit: www.eaton.com Reset Input (Terminal 4) designed for contact closures to DC common Min. Low: 0.25 to 1 sec. (reset is maintained) Note: The required pulse width varies with count speed, scale factor and number of digits displayed. Voltage Thresholds -- Low: 0 - 0.4V DC High: 2.0 - 28V DC Front Panel Reset Enable Front Panel Reset Enable (Terminal 5) Operation: Level sensitive (maintained) 25 26 Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 Courier Series -- Durant(R) Product Selection Table 30. Product Selection -- Courier Series, 8-digit LCD Description Catalog Number Totalizer, Battery Add/Subtract (10k Hz, PNP input) Totalizer, Battery Add/Subtract (20 Hz, NPN/Contact input) Totalizer, Battery Quadrature (10k Hz, PNP input) Totalizer, Battery 53300400 53300401 53300402 53300403 Totalizer/Ratemeter, Battery Totalizer/Ratemeter @ 100 Hz, Battery RMF Panel Mount Totalizer, Key Reset, 60 - 160V AC/DC Count Input RMF Panel Mount Totalizer, Dry Contact Input RMF Panel Mount Totalizer, 60 - 160V AC/DC Count Input 53300405 53300465 53300800 53300850 53300851 Totalizer -- Extended Temperature Range, Battery Totalizer -- 1/Tau Ratemeter -- Extended Temperature Range Totalizer/Ratemeter -- Extended Temperature Range, Battery Totalizer/Ratemeter, Mag Pickup, Battery Backlight Totalizer, Battery 53301400 53301404 53301405 53301475 53302400 Backlight Add/Subtract (10k Hz, PNP input) Totalizer, Battery Backlight Add/Subtract (20 Hz, NPN/Contact input) Totalizer, Battery Backlight Quadrature (10k Hz, PNP input) Totalizer, Battery Backlight Totalizer/Ratemeter, Battery 53302401 53302402 53302403 53302405 * When Ordering Specify When ordering Courier series electronic totalizers and ratemeters, specify Order Numbers according to the features selected. Dimensions 1.25 (31.8) 2.95 (74.9) 2.67 (67.8) 1.57 (39.9) T/R Recommended Panel Cutout 1.30 (33.0) RST Figure 39. Courier Series Totalizers -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 27 April 2007 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter Cat. No. E5-496-E0401 Features Display counter adding and subtracting Position display Frequency counter/ratemeter Timer, res. up to 0.001 sec. Programmable mode Display Range: -199.999 - 999.999 with zero blanking Connection with screw terminal Locking SET-Key for reset Standards and Certifications Input Switching Level -- DC Version (standard version) High: 0.6 x UB - 30V DC Low: 0 - 0.2 x UB [V DC] AC Version High: 12 - 30V DC Low: 0 - 4V DC Input Switching Level -- 5V Version High: 4 - 30V DC Low: 0 - 2V DC Voltage Supply for Sensors: 24V DC 15%/100 mA at AC versions Accuracy -- Tachometer: <0.1% Timer: <50 ppm Ambient Temperature: -4 to 149F (-20 to 65C) Storage Temperature: -13 to 167F (-25 to 75C) EMC: According to EC EMC directive 89/36/EWG Immunity to Interference: EN 61 000-6-4/ EN 55011 Class B Emitted Interference: EN 61-000-6-2 Protection: IP65 (from front) Weight: Approx. 5.29 oz (150 g) Product Selection Table 31. Product Selection -- 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter Description Catalog Number 90 - 260V AC Power 3.78 x 1.89 Inch (96 x 48 mm) 10 - 30V DC Power 3.78 x 1.89 Inch (96 x 48 mm) E5-496-E0401 E5-496-E0402 Dimensions UL Recognized CE Marked Supply Voltage: 10 - 30V DC with reverse polarity protection; 90 - 260V AC Current Consumption: Max. 50 mA 6 VA Display: 6-digit red, 7-segment LED display; 0.55 Inch (14 mm) high Data Backup: EEPROM Housing: Dimension 3.78 x 1.89 Inch (96 x 48 mm) according to DIN 43 700; RAL 7021 gray Polarity of Inputs: Programmable, NPN or PNP for all inputs Input Resistance: Approx. 10 k1 Counting Frequency: 60 kHz, can be damped to 30 Hz depending on operating mode at position display max. 25 kHz Reset Time: 5 mS Resolution Timer: Up to 0.001 sec. * LED Multifunction Counter/Timer/Ratemeter Max. 0.75 (19.0) 3.78 (96.0) Technical Data and Specifications 1.89 (48.0) 1.77 x 3.62 (44.9 x 91.9) 0.61 (15.5) 0.26 (6.5) 0.16 (4.0) 2.64 (67.1) 1.77 +0.02 (45.0 +0.6) 3.62 +0.03 (92.0 +0.8) Figure 40. 1/8 DIN LED Multifunction Totalizer/Timer/Ratemeter -- Approximate Dimensions in Inches (mm) For further specifications, please refer to the user manual. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 28 April 2007 Eclipse Series -- Durant(R) Environmental Data Retention Cat. No. 57700480 Features 1/8 DIN cutout NEMA 4X front panel Universal AC power supply (85 - 265V AC) DC power models (9 - 30V DC) Removable screw terminals Short Depth: 3.6 inch (91 mm) Front panel programming Standards and Certifications UL and cUL Listed, CE Marked Technical Data and Specifications Mechanical Cutout Dimensions: 3.62" W x 1.77" H (92 mm x 45 mm) DIN standard Outline Dimensions: 4.04" W x 2.19" H x 3.87" D (103 mm x 56 mm x 98 mm) 3.60" (92 mm) maximum depth in panel Enclosure: Plastic with polyester front label Connectors: Up to six depluggable terminal blocks Operating Environment: Indoor use to 2000 meters Temperature -- Operating: 32 to 122F (0 to 50C) Storage: -4 to 158F (-20 to 70C) Humidity: 0 to 85% RH, noncondensing Vibration: 2.5 Gs, 30 to 200 Hz Shock: 30 Gs, 11 mS half sinewave EMC -- Immunity to EN 50082-2 (Heavy Industrial) Emissions to EN 50081-2 (Heavy Industrial) Front Panel: NEMA 4X when mounted with gasket provided CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution Degree 2: Overvoltage category II Memory Type: EEPROM, no batteries required Duration: 100 years Count Signal Input Input Power AC Powered Models (57701-4XX) -- Input Power: 85 - 295V AC, 47 - 63 Hz, 20 VA External Fuse: 0.2A, 250V AC, Time Delay (T200 mA, 250V) Isolation Dielectric Strength: 2300V AC DC Powered Models (57700-4XX) -- Input Power: 9 - 30V DC, 12 VA External Fuse: 2.0A, 50V DC, Time Delay (T2A, 50V) Reverse Voltage Protection: Yes Isolation Dielectric Strength: 2300V AC to signal outputs and relays, 500V AC to RS-485 and analog outputs Sensor Type: Sink or source, DIP switch selectable Input Impedance: 4.75k ohms to +5V DC or 34.9k ohms to ground Thresholds -- High: 3.5 - 28V DC Low: 0 - 1.9V DC, for single ended signals Magnetic Pickup Range: 200 mV p-p to 65 VRMS into 34.9k ohms Slow Response: 200 Hz max. (DIP switch 2 and/or 5 ON) Fast Response -- Count Mode: A or B Add/Add, Add/Subtract, Add w/ Inh: 8250/8250 Fast Response -- Count Mode: A and B Add/Add, Add/Subtract, Add w/ Inh: 3000/3000 Quad x1, Quad x2: 3250 Quad x4: 2000 Control Inputs Sensor Type: Sink only Input Impedance: 4.75k ohms to +5V DC Thresholds -- High: 3.5 to 28V DC Low: 0 - 1.9V DC Response: 25 mS maximum (5V signal) Accessory Power Output Voltage: 12V DC +10%/-13% Current: 75 mA max. Protection: Short circuit protected Human Interface Display: +6, -5 digits Type: 0.56" (14.2 mm) high, seven segment, red LED For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 Eclipse Series -- Durant(R) Product Selection Table 32. Product Selection -- Eclipse Series Totalizer, 6-digit LED Description Catalog Number 9 - 30V DC Power 85 - 265V AC Power 57700480 57701480 Analog Out, 9 - 30V DC Power Analog Out, 85 - 265V AC Power 57700482 57701482 RS-485 Out, 9 - 30V DC Power RS-485 Out, 85 - 265V AC Power 57700484 57701484 RS-485 Out and Analog Out, 9 - 30V DC Power RS-485 Out and Analog Out, 85 - 265V AC Power 57700486 57701486 * Dimensions (R) Durant 2.19 (55.6) 1.772 0.02 (45 0.6) PGM 4.04 (102.6) 3.622 0.03 (92.00 0.8) Panel Cutout Max. Panel Thickness 0.190 (4.83) 3.63 (92.2) 3.31 (84.1) 0.27 (6.9) Figure 41. Eclipse Series Totalizer -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 29 Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 30 April 2007 President Series -- Durant(R) Counter Cat. No. 58811400 Features 8-digit, LED display, 0.56" (14 mm) Programmable decimal point and count and rate scaling 15V DC @ 100 mA output power Rear panel screw terminals NEMA 4 front panel Count Range: 8 digits (0 to 99,999,999) with rollover Offset Range: 8 digits (0 to 99,999,999) (Offset is used to reset to a non-zero number.) Count Modes -- Count with Add and Subtract inputs Count with Up/Down direction input (Hardware doubling for above modes is provided) Count with Count Inhibit input Quadrature Doubled Quadrature Standards and Certifications UL Listed, CSA marked CE Marked Technical Data and Specifications Power Requirements AC Operation: 115/230V AC (+10%, -20%) 47 - 63 Hz DC Operation: 11 - 28V DC Power: 18 watts DC Power Output 15V DC (+1, -2). 150 mA if powered from AC or less than 24V DC 100 mA if powered from 24V DC or greater Note: DC power output is only regulated if unit is powered by AC or greater than 18.5V DC. Environment Operating Temperature: 32 to 130F (0 to 55C) Storage Temperature: -40 to 160F (-40 to 70C) Operating Humidity: 85% noncondensing relative Physical Memory Types: PROM, RAM, Nonvolatile NVRAM Count Speed (Scale Factor of 1.0000 assumed) 0 to 7,500 counts per second (CPS) with Durant Shaft Encoders or solid-state sensors 0 to 3,750 CPS when hardware doubling is implemented or when quadrature shaft encoders are used 0 to 150 CPS when Low Frequency is selected Count Input Ratings The count inputs are designed to work with current sinking sensors (opencollector NPN transistor output with or without passive pull-up resistor) or contact closures to DC Common. Input Voltage -- High state (Logical "1", sensor off or contact open) - 10.5 - 24.5V DC when control is powered by AC line - 7.0 - 24.5V DC when control is powered by 11V DC - 11.0 - 24.5V DC when control is powered by 16V DC Low state (Logical "0", sensor on or contact closed) - 0 - 4.5V DC when control is powered by AC line - 0 - 3.3V DC when control is powered by 11V DC - 0 - 4.8V DC when control is powered by 16V DC Input Impedance -- 6800 ohms to 15V DC when control is powered by AC line 6800 ohms to 10V DC when control is powered by DC supply Input Current: 20 mA peak, 3 mA steady state For more information visit: www.eaton.com Input Response -- High State (Logical "1", sensor off or contact open) - High Speed (Low Speed jumpers not connected) - 110 S minimum at 15V DC (6,800 ohms to +DC) - 160 S minimum at 13.5V DC (50,000 ohms to +DC) High State (Logical "1", sensor off or contact open) - Low Speed (Low Speed jumpers connected) - 5.5 mS minimum at 15V DC (6,800 ohms to +DC) - 7.5 mS minimum at 13.5V DC (50,000 ohms to +DC) Low State (Logical "0", sensor on or contact closed) - High Speed (Low Speed jumpers not connected) - 20 S minimum at 0.1V DC (0 ohms to DC Common) - 45 S minimum at 1.5V DC (500 ohms to DC Common) Low State (Logical "0", sensor on or contact closed) - Low Speed (Low Speed jumpers connected) - 1.0 mS minimum at 0.1V DC (0 ohms to DC Common) - 2.0 mS minimum at 1.5V DC (500 ohms to DC Common) Scale Factor Range: 5 digits (0.0001 to 9.9999) Control Inputs Input Voltage -- High State (Logical "1", contact open) 15V DC maximum Low State (Logical "0", contact closed) 1.2V DC maximum Input Impedance: 4.75K ohms to +5V DC. Threshold -- High: +3.5 to +22V DC Low: +0.0 to +1.0V DC Response Time -- Min. High: 5.3 mS Min. Low: 3.9 mS Note: The reset and unlatch signals will both occur in less than 200 microseconds after the input signal is detected. The start of the print will occur within 2 milliseconds after the input is detected if the unit is not counting. PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 Diagnostic Modes ROM Checksum RAM Bit Test NVRAM Read/Write Test NVRAM Store Test NVRAM Checksum Watchdog Timer Display and LED Indicator Test President Series -- Durant(R) Product Selection Table 33. Product Selection -- President Series Totalizers Description Catalog Number 115/230V AC, LED Red Display 115/230V AC, LED Red Display, 1/Tau Ratemeter 58811400 58815400 * Dimensions Communications Interface Type: Dual port 20 mA current loop Speed: 110, 300 and 1200 Baud, user selectable Data Type: Standard ASCII code Format: Start bit, 7 ASCII data bits, Parity bit, one or two Stop bits (Even parity for Serial Data Output, no parity for Serial Data Input) 0.735 0.02 (18.7 0.5) 5.433 0.04 (138 1.0) 2.677 0.03 (68 0.7) Recommended Panel Cutout 2.62 0.025 (66.67 0.6) 0.95 0.04 (24.1 1.0) 5.53 0.015 (140.5 0.4) Information Transmitted -- Count value Offset value Scale Factor 5.78 0.02 (146.8 0.5) 5.91 0.03 (150.1 0.8) Durant Information Received -- Print request Offset value Scale Factor Offset Count 1 2 3 4 5 6 7 8 9 3.04 0.015 (77.2 0.4) 10 11 12 13 14 15 16 17 18 IN1 IN2 USE EXTERNAL FUSE! Preset 1 1 2 3 4 5 Count Function 6 7 8 9 0 Reset Enter 5.80 0.015 (147.3 0.4) IN OUT K1 115/230V~ K2 50/60 Hz + + 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 5.38 0.02 (136.7 0.5) 6.25 0.02 (158 0.5) Figure 42. President Series Totalizers -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 31 Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 32 April 2007 President Series -- Durant(R) Counter DC Power Output Count Input Ratings 15V DC (+1, -2) 150 mA if powered from AC or less than 24V DC 100 mA if powered from 24V DC or greater The count inputs are designed to work with current sinking sensors (opencollector NPN transistor output with or without passive pull-up resistor) or contact closures to DC Common. Input Current: 20 mA peak, 3 mA steady state Input Response -- High State (Logical "1", sensor off or contact open) - High Speed (Low Speed jumpers not connected) - 110 S minimum at 15V DC (6,800 ohms to +DC) - 160 S minimum at 13.5V DC (50,000 ohms to +DC) High State (Logical "1", sensor off or contact open) - Low Speed (Low Speed jumpers connected) - 5.5 mS minimum at 15V DC (6,800 ohms to +DC) - 7.5 mS minimum at 13.5V DC (50,000 ohms to +DC) Low State (Logical "0", sensor on or contact closed) - High Speed (Low Speed jumpers not connected) - 20 S minimum at 0.1V DC (0 ohms to DC Common) - 45 S minimum at 1.5V DC (500 ohms to DC Common) Low State (Logical "0", sensor on or contact closed) - Low Speed (Low Speed jumpers connected) - 1.0 mS minimum at 0.1V DC (0 ohms to DC Common) - 2.0 mS minimum at 1.5V DC (500 ohms to DC Common) Note: DC power output is only regulated if unit is powered by AC or greater than 18.5V DC. Control Inputs Standards and Certifications Count Range: 8 digits (0 to 99,999,999) with rollover Offset Range: 8 digits (0 to 99,999,999) (Offset is entered through serial communication only. It is used to reset to a non-zero number.) Count Modes -- Count with Add and Subtract inputs Count with Up/Down direction input (Hardware doubling for above modes is provided) Count with Count Inhibit input Quadrature Doubled Quadrature Cat. No. 58810400 Features 8-digit, LED display, 0.56" (14 mm) 15V DC @ 100 mA output power Rear panel screw terminals NEMA 4 front panel UL Listed, CSA marked CE Marked Technical Data and Specifications Power Requirements AC Operation: 115/230V AC (+10%, -20%) 47 - 63 Hz DC Operation: 11 - 28V DC Power: 18 watts Environment Operating Temperature: 32 to 130F (0 to 55C) Storage Temperature: -40 to 160F (-40 to 70C) Operating Humidity: 85% noncondensing relative Physical Memory Types: PROM, RAM, Nonvolatile NVRAM Count Speed 0 to 10,000 counts per second (CPS) with Durant Shaft Encoders or solid-state sensors with internal pull-up resistor 0 to 7,500 CPS minimum for sensors with open collector transistor output 0 to 5,000 CPS when hardware doubling is implemented 0 to 150 CPS when Low Frequency is selected Input Voltage -- High state (Logical "1", sensor off or contact open) - 10.5 - 24.5V DC when control is powered by AC line - 7.0 - 24.5V DC when control is powered by 11V DC - 11.0 - 24.5V DC when control is powered by 16V DC Low state (Logical "0", sensor on or contact closed) - 0 - 4.5V DC when control is powered by AC line - 0 - 3.3V DC when control is powered by 11V DC - 0 - 4.8V DC when control is powered by 16V DC Input Impedance -- 6800 ohms to 15V DC when control is powered by AC line 6800 ohms to 10V DC when control is powered by DC supply For more information visit: www.eaton.com Impedance: 4.75k ohms to +5V DC Threshold -- High: +3.5 to +22V DC Low: +0.0 to +1.0V DC Response Time -- Min. High: 5.3 mS Min. Low: 3.9 mS Note: The reset and unlatch signals will both occur in less than 200 microseconds after the input signal is detected. The start of the print will occur within 2 milliseconds after the input is detected if the unit is not counting. Counter Operating Modes Reset -- Reset to zero Reset to offset value Maintained Reset Momentary Reset PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 Communications Interface Type: Dual port 20 MA current loop Speed: 110, 300 and 1200 Baud, user selectable Data Type: Standard ASCII code Format: Start bit, 7 ASCII data bits, Parity bit, one or two Stop bits (Even parity for Serial Data Output, no parity for Serial Data Input) President Series -- Durant(R) Product Selection Table 34. Product Selection -- President Series Totalizers Description Catalog Number 115V AC, 7-digit LED Red Display, Basic Pulse Count 115/230V AC, LED Red Display Feet/Inches Totalizer 57810400 58810400 57810402 * Dimensions Information Transmitted -- Count value Offset value Information Received -- Print request Offset value Print offset enable or disable 5.43 0.04 (138 1.0) 1.74 0.01 (44.20 0.25) Recommended Panel Cutout 1.77 0.025 (45 0.6) 5.53 0.015 (140.5 0.4) 0.17 0.01 (4.3 0.24) Durant 1 2.16 0.015 (54.9 0.4) Reset 2 3 4 5 6 SWA 7 8 1 2 3 4 5 SWB IN OUT IN1 115/230V~ IN2 + + 50/60 Hz P R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 5.80 0.015 (147.3 0.4) 5.38 0.015 (136.7 0.4) Figure 43. President Series Totalizers -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 33 Counters, Panel Meters, Tachometers and Timers Electronic Totalizers 34 April 2007 Ambassador Series -- Durant(R) Totalizer Control Inputs Type: Bi-directional Digits: 8 Scaler Range: 0.00001 to 9.99999 Decimal Point: 5 positions, programmable Totalizer Count Speeds Cat. No. 57600400 Features AC/DC powered, 2-line LCD display 8-digit totalizer 1/Tau ratemeter Totalizer and ratemeter scaling Four user-configurable control inputs Two solid-state outputs RS-485 Serial communications Standards and Certifications UL Listed CE Marked Technical Data and Specifications Power Input AC Operation -- 115V AC (15%) std., 50 to 60 Hz, 7W 230V AC (15%) opt., 50 to 60 Hz, 7W DC Operation: 10 - 15V DC opt., 300 mA maximum DC Power Output 12V DC (25%), 100 mA maximum (includes all line and load variations) Environmental Operating Temperature: 32 to 131F (0 to 55C) Storage Temperature: -4 to 158F (-20 to 70C) Operating Humidity: 85% Relative, non-condensing NEMA 4 rating when mounted with gasket provided The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input. Maximum Speed -- Solid-State (High Speed) Mode Input A/ Input B -- Add/Sub: 20 kHz Add/Add: 20 kHz Count/Direction: 15 kHz Count x 2/Direction: 7.5 kHz Quadrature: 6.5 kHz Quadrature x 2: 6.5 kHz Maximum Speed -- Contact (Low Speed) Mode Input A/ Input B -- Add/Sub: 40 kHz Add/Add: 40 kHz Count/Direction: 40 kHz Count Inputs Impedance: 4.7k ohms to +5V DC Voltage -- High: +3.7 to +24V DC Low: 0.0 to 0.9V DC Response: Minimum low 15 mS, minimum high 15 mS Transistor Outputs (2) Type: NPN open collector with transient protection Maximum Voltage (OFF state): 30V DC Maximum Current (ON state): 200 mA @ 1.3V DC Communication Type: RS-485 Format: 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit Protocol: Opto-22 compatible Speed: 300, 1200, 2400, 4800, 9600 and 19200 baud Parity: Odd, Even, None (space transmitted, ignore received) Count Accuracy Sink -- Impedance: 4.6k ohms to +5V DC Voltage -- High: 3.5 to 34.0V DC Low: 0.0 to 1.9V DC Source (high) -- Impedance: 2.3k ohms to common Voltage -- High: 3.5 to 17.0V DC (100% duty cycle) Low: 0.0 to 1.9V DC Source (low) -- Impedance: 2.3k ohms to common DC Voltage -- High: 0.6 to 17.0V DC Low: -17.0 to -0.6V DC AC Voltage: 17V AC (48V PeakPeak) maximum For more information visit: www.eaton.com 100% when operated within the specified count speeds and count signal high and low times Rate Indicator Type: 1/Tau Digits: 6 Scaler Range: 0.00001 to 99999 Decimal Point: 5 positions, programmable Accuracy: 0.015% of reading Update Time: 1 second, fixed Zero Time: 10 seconds, fixed Connections Type: Dual depluggable screw terminal strips Conductor Size: 14 - 22 AWG (2.1 - 0.38 mm2), 600V, solid, stranded or fused (preferred) PG05400001E Counters, Panel Meters, Tachometers and Timers Electronic Totalizers April 2007 Ambassador Series -- Durant(R) Product Selection Table 35. Product Selection -- Ambassador Series Totalizers Description Catalog Number 10 - 15V DC LCD 115V AC LCD 230V AC LCD 57600400 57601400 57602400 * Dimensions Durant (R) C 123456 P1 10000 RST CLR RUN PGM PRNT EXIT ENT SEL 2.946 0.015 (74.83 0.38) * 2.946 0.015 (74.83 0.38) 5.60 0.03 (142.24 0.76) Gasket 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 Panel Cutout Max. Panel Thickness 0.50 (12.7) 2.677 0.028 (68.00 0.70) 2.677 0.028 (68.00 0.70) Figure 44. Ambassador Series Totalizers -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 35 36 Counters, Panel Meters, Tachometers and Timers Count Controls/Preset Counters April 2007 Product Family Overview Introduction Rotary Contactor Count controls are counters that provide output signal(s) at preset count value(s). Typical applications include cut-tolength, batching, filling, mixing and dispensing. Available from Eaton are a variety of count controls in different sizes, display types and feature sets. Application Example Paper The illustration shows a simple cut-to-length application. The roll of paper is measured using a measuring wheel and rotary contactor (or encoder). Once the desired length is reached, an output signal may be directed to a shear for activation. Following the cut-off, the count control will reset to zero and begin measurement of the next piece. Options such as batch counting, where the number of cut pieces is counted, are also typical of this application. Measuring Wheel Roll Application Example Count Control Product Family Overview Table 36. Product Family Overview Product Family Characteristics Panel Cutout in Inches (mm) Page Number 1.772 x 1.772 (45 x 45) 37 1.772 x 1.622 (45 x 92) 41 6-digit, high-visibility, 2-line LCD display User-configurable control inputs Highly flexible control/display 2.667 x 2.667 (68 x 68) 43 Bright LED display w/14 mm characters Simple configuration with 14-button tactile keypad Many different versions fit almost any application 2.667 x 5.433 (68 x 138) 46 Integrated controller combines operator interface, ladder logic 2.667 x 5.433 (68 x 138) 79 Various Mounting Configurations 50 Low cost, simple count control Various power options: battery, AC, DC Easy-to-change preset values 2-line display: input and preset values E5-148-C 6-digit, super bright LED display Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls Eclipse Ambassador President and high-speed counting Fusion Various price, voltage and size ranges for different duty cycles and environments Long life and always readable display Electromechanical For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 1/16 DIN Battery Powered LCD Count Control Standards and Certifications Contents Description Count Control 1/16 DIN Battery Powered LCD Count Control . . . . . 1/16 DIN LCD Count Control . . . . . . . . . . . . . . . Eclipse Series . . . . . . . . . . Ambassador Series . . . . . . President Series . . . . . . . . PD-Q and PD-ER Series . . . . . . . . . . . . . . . . Page 37 39 41 43 46 cRU(R)us Approval CE Marked Technical Data and Specifications 50 Cat. No. E5-148-C1400 Features Replacement for electromechanical preset counters No power supply necessary (battery operated) Count and reset input electrically separated from counter through optocoupler input range 12 - 250V AC/DC 2-line LC display count, preset and level of the output Screw terminal Data security, through two exchangeable lithium batteries, lifetime minimum 8 years Easy programming Counter presets easily via presetting keys allocated to each decade Output: Potential free relay, programmable normally open or normally closed contact PG05400001E Power Supply: 2 pcs user exchangeable lithium batteries, Type 1/2 AA lithium 3.6V Display: 2-line LCD display, 6 digits; 999999, height of figure 0.28 Inch (7 mm) or 0.18 Inch (4.5 mm) Input: Reset, count and key lock inputs Polarity of the Inputs: Bidirectional optocoupler input for the reset count inputs; reset, count and keyboard lock is connected to 3V DC Min. pulse duration of the Inputs: Reset input 50 mS; keyboard lock input 15 mS Switching Levels of the Inputs -- Low: <3V AC/DC High: 12 - 250V AC/DC Input Frequency: Max. 25 Hz Input Resistance: 110 k1 Output: Bistable relay with potential free contact (programmable as normally closed or normally open contact) For more information visit: www.eaton.com Max. Switching Voltage: 250V AC/ 220V DC Max. Switching Current: 2A Max. Switching Capacity: 60 VA/30W Output Response Time: <20 mS, max. 4 Hz Data Retention: Via 2 batteries, 8 years or 5x106 power operations of the output relay and an ambient temperature of 77F (25C) Ambient Temperature: 14 to 122F (-10 to 50C) Storage Temperature: -13 to 140F (-25 to 60C) EMC: According to EC EMC directive 89/36/EWG, EN 61 000-6-4/ EN 55011 Class B, EN 61 000-6-2 Protection: IP65 (front) Weight: Approx. 2.82 oz (80 g) 37 38 Counters, Panel Meters, Tachometers and Timers Count Control April 2007 1/16 DIN Battery Powered LCD Count Control Product Selection Table 37. Product Selection -- 1/16 DIN Battery Powered LCD Count Control Description Catalog Number * 1 Preset Count Control Battery Power 1.89 x 1.89 Inch (48 x 48 mm) E5-148-C1400 Dimensions Max. 0.41 (10.5) 1.89 (48.0) 1.89 (48.0) 648.732 850.000 123456 7 SQ 1.77 (45) 0.63 (16.0) 1 2 3 4 5 6 7 2.49 (63.2) 0.12 (3.0) Panel Cut-Out 1.77 x 1.77 (45 x 45) 2.17 (55.0) 2.17 (55.0) Max. 0.37 (9.5) 648.732 850.000 SQ 1.77 (45) 0.63 (16.0) With Front Bezel No. 2 Panel Cut-Out 1.97 x 1.97 (50 x 50) 2.36 (60.0) 2.95 (75.0) 648.732 850.000 SQ 1.97 (50) 2.45 (62.2) 0.16 (4.0) Max. 0.37 (9.5) 2.48 (63) Flush Bf4, DIN 74 SQ 1.77 (45) 0.63 (16.0) SQ 1.97 (50) 2.45 (62.2) 0.16 (4.0) With Front Bezel No. 3 Panel Cut-Out 1.97 x 1.97 (50 x 50) Figure 45. 1/16 DIN Battery Powered LCD Count Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 1/16 DIN LCD Count Control Technical Data and Specifications Cat. No. E5-148-C2421 Features 2-Line LCD display Programmable as impulse counter, frequency meter or time meter with sign and zero blanking Power Supply: 90 - 260V AC or 10 - 30V DC Batch mode Display range -199.999 - 999.999 with zero blanking Easy to operate and set the preset values via 4 keys Relay or octocoupler-output Scaling factor 0.0001 - 9.9999 1 preset value, 1 output 2 preset values, 2 outputs Standards and Certifications cRU(R)us Approval CE Marked PG05400001E Supply Voltage: 10 - 30V DC with reverse polarity protection; 90 - 260V AC max. 4 VA Display: 2-line LCD display, 6-digits Count Inputs: 2 count inputs, 4 input modes are programmable Polarity of the Inputs: Programmable for all inputs in common Input Resistance: Approx. 10 k1 Count Frequency: 10 kHz via DIPswitches reducible for INP A and INP B to 30 Hz (0.7 kHz at input mode E3 and E4 phase discriminator), automatic repeat at 900 Hz without losing counts (500 Hz for input mode E4) Min. Pulse Duration of the Inputs: 5 mS Input Sensitivity -- DC Supply Voltages High: 0.6 x UB - 30V DC Low: 0 - 0.2 x UB [VDC] AC Supply Voltages High: 12 - 30V DC Low: 0 - 4V DC Pulse Shape: Variable (SchmittTrigger characteristics) Output 1: Relay -- With potential free contact, programmable as normally open or normally closed Switching voltage max.: 250V AC/ 125V DC Switching current max.: 3A Switching current at DC min.: 30 mA Switching power at DC: 90W Switching power at AC max.: 750 VA For more information visit: www.eaton.com OR NPN Optocoupler -- With open collector and emitter switching power 30V DC/15 mA Output 2: Relay -- With potential free contact, programmable as normally open or normally closed Switching voltage max.: 250V AC/ 125V DC Switching current max.: 3A Switching current at DC min.: 30 mA Switching power at DC: 90W Switching power at AC max.: 750 VA OR NPN Optocoupler -- With open collector and emitter switching power 30V DC/15 mA Reaction Time of the Inputs -- Relay: Approx. 7 mS Optocoupler: Approx. 1 mS Data Retention: Min. 10 years or 1x106 memory cycles Transmitter Voltage: 24V DC -40%/ 15%. 100 mA at 90 - 250V AC With optional backlight -- 24V DC -40% 15%. 60 mA at 90 - 260V AC Ambient Temperature: 32 to 122F (0 to 50C) Storage Temperature: -13 to 158F (-25 to 70C) EMC: According to EC EMC directive 89/36/EWG, EN 61 000-6-4/ EN 55011 Class B, EN 61 000-6-2 Protection: IP65 (front) Weight: Approx. 8.47 oz (240 g), AC version with relay 39 40 Counters, Panel Meters, Tachometers and Timers Count Control April 2007 1/16 DIN LCD Count Control Product Selection Table 38. Product Selection -- 1/16 DIN LCD Count Control Description Catalog Number * 1 Preset LCD Count Control 90 - 260V AC Power 1.89 x 1.89 Inch (48 x 48 mm) 10 - 30V DC Power 1.89 x 1.89 Inch (48 x 48 mm) E5-148-C1421 E5-148-C1422 2 Preset LCD Count Control 90 - 260V AC Power 1.89 x 1.89 Inch (48 x 48 mm) 10 - 30V DC Power 1.89 x 1.89 Inch (48x 48 mm) E5-148-C2421 E5-148-C2422 Dimensions Max. 0.41 (10.5) 1.89 (48.0) 1.89 (48.0) -903.682 123456 7 SQ 1.77 (45) -903.250 PR1 0.61 (15.5) 1 2 3 4 5 6 7 3.40 (86.5) 0.12 (3.0) Panel Cut-Out 1.77 x 1.77 (45 x 45) 2.17 (55.0) 2.17 (55.0) Max. 0.37 (9.5) -903.682 123456 7 SQ 1.77 (45) -903.250 PR1 0.61 (15.5) SQ 1.97 (50) 3.37 (85.5) 1 2 3 4 5 6 7 0.12 (4.0) With Front Bezel No. 2 Panel Cut-Out 1.97 x 1.97 (50 x 50) 2.36 (60.0) 2.95 (75.0) -903.682 -903.250 PR1 Max. 0.37 (9.5) 123456 7 2.48 SQ 1.77 (63) (45) Flush Bf4, DIN 74 0.61 (15.5) SQ 1.97 (50) 3.37 (85.5) 1 2 3 4 5 6 7 0.16 (4.0) With Front Bezel No. 3 Panel Cut-Out 1.97 x 1.97 (50 x 50) Figure 46. 1/16 DIN LCD Count Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 Eclipse Series -- Durant(R) Environmental Data Retention Cat. No. 57700481 Features 1/8 DIN cutout NEMA 4X front panel Universal AC power supply (85 - 265V AC) DC power models (9 - 30V DC) Removable screw terminals Short Depth: 3.6 inch (91 mm) Front panel programming Standards and Certifications UL and cUL Listed, CE Marked Technical Data and Specifications Mechanical Cutout Dimensions: 3.62" W x 1.77" H (92 mm x 45 mm) DIN standard Outline Dimensions: 4.04" W x 2.19" H x 3.87" D (103 mm x 56 mm x 98 mm) 3.60" (92 mm) maximum depth in panel Enclosure: Plastic with polyester front label Connectors: Up to six depluggable terminal blocks Operating Environment: Indoor use to 2000 meters Temperature -- Operating: 32 to 122F (0 to 50C) Storage: -4 to 158F (-20 to 70C) Humidity: 0 to 85% RH, noncondensing Vibration: 2.5 Gs, 30 to 200 Hz Shock: 30 Gs, 11 mS half sinewave EMC -- Immunity to EN 50082-2 (Heavy Industrial) Emissions to EN 50081-2 (Heavy Industrial) Front Panel: NEMA 4X when mounted with gasket provided CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution Degree 2: Overvoltage category II Count Signal Input Input Power AC Powered Models (57701-4XX) -- Input Power: 85 - 295V AC, 47 - 63 Hz, 20V A External Fuse: 0.2A, 250V AC, Time Delay (T200 mA, 250V) Isolation Dielectric Strength: 2300V AC DC Powered Models (57700-4XX) -- Input Power: 9 - 30V DC, 12V A External Fuse: 2.0A, 50V DC, Time Delay (T2A, 50V) Reverse Voltage Protection: Yes Isolation Dielectric Strength: 2300V AC to signal outputs and relays, 500V AC to RS-485 and analog outputs Human Interface PG05400001E Memory Type: EEPROM, no batteries required Duration: 100 years Display: +6, -5 digits Type: 0.56" (14.2 mm) high, seven segment, red LED For more information visit: www.eaton.com Sensor Type: Sink or source, DIP switch selectable Input Impedance: 4.75k ohms to +5V DC or 34.9k ohms to ground Thresholds -- High: 3.5 - 28V DC Low: 0 - 1.9V DC, for single ended signals Magnetic Pickup Range: 200 mV p-p to 65 VRMS into 34.9k ohms Slow Response: 200 Hz max. (DIP switch 2 and/or 5 ON) Fast Response -- Count Mode: A or B Add/Add, Add/Subtract, Add w/ Inh: 8250/8250 Fast Response -- Count Mode: A and B Add/Add, Add/Subtract, Add w/ Inh: 3000/3000 Quad x1, Quad x2: 3250 Quad x4: 2000 Control Inputs Sensor Type: Sink only Input Impedance: 4.75k ohms to +5V DC Thresholds -- High: 3.5 to 28V DC Low: 0 - 1.9V DC Response: 25 mS maximum (5V signal) Accessory Power Output Voltage: 12V DC +10%/-13% Current: 75 mA max. Protection: Short circuit protected 41 42 Counters, Panel Meters, Tachometers and Timers Count Control April 2007 Eclipse Series -- Durant(R) Product Selection Table 39. Product Selection -- LED Count Control, 6-digit Description Catalog Number Relay Out, 9 - 30V DC Power Relay Out, 85 - 265V AC Power 57700481 57701481 Relay & Analog Out, 9 - 30V DC Power Relay & Analog Out, 85 - 265V AC Power 57700483 57701483 Relay & RS-485 Out, 9 - 30V DC Power Relay & RS-485 Out, 85 - 265V AC Power 57700485 57701485 Relay, Analog & RS-485 Out, 9 - 30V DC Power Relay, Analog & RS-485 Out, 85 - 265V AC Power 57700487 57701487 * Dimensions (R) Durant 2.19 (55.6) 1.772 0.02 (45 0.6) PGM 4.04 (102.6) 3.622 0.03 (92.00 0.8) Panel Cutout Max. Panel Thickness 0.190 (4.83) 3.63 (92.2) 3.31 (84.1) 0.27 (6.9) Figure 47. Eclipse Series Count Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 Ambassador Series -- Durant(R) Main Counter Control Inputs Cat. No. 57601401 Features AC/DC powered, 2-line LCD display 8-digit totalizer 1/Tau ratemeter Totalizer and ratemeter scaling Four user-configurable control inputs Up to two output relays Two solid-state outputs RS-485 Serial communications Feet/Inches control available Standards and Certifications UL Listed CE Marked Technical Data and Specifications Power Input AC Operation -- 115V AC (15%) std., 50 to 60 Hz, 7W 230V AC (15%) opt., 50 to 60 Hz, 7W DC Operation: 10 - 15V DC opt., 300 mA maximum DC Power Output 12V DC (25%), 100 mA maximum (includes all line and load variations) Environmental Type: Bi-directional Digits: 6 Presets: Varies by Model Reset modes: Auto or manual reset to zero or preset Scaler Range: 0.00001 to 9.99999 Decimal Point: 5 positions, (6 on 4preset models) Output Latency: See Table 40 Batch Counter Type: Increment with main counter recycle or final preset signal Digits: 6 Presets: 1 Output Latency: < 1 mS Totalizer Type: Bi-directional, same or opposite of main counter Digits: 8 Scaler: Shared with main counter Decimal Point: Tracks main counter Count Input Speeds See Tables 42 and 43 Count Inputs Sink -- Impedance: 4.6k ohms to +5V DC Voltage -- High: 3.5 to 34.0 Low: 0.0 to 1.9V DC Source (high) -- Impedance: 2.3k ohms to common Voltage -- High: 3.5 to 17.0V DC (100% duty cycle) Low: 0.0 to 1.9V DC Source (low) -- Impedance: 2.3k ohms to common DC Voltage -- High: 0.6 to 17.0V DC Low: -17.0 to -0.6V DC AC Voltage: 17V AC (48V PeakPeak) maximum Operating Temperature: 32 to 131F (0 to 55C) Storage Temperature: -4 to 158F (-20 to 70C) Operating Humidity: 85% Relative, non-condensing NEMA 4 rating when mounted with gasket provided For more information visit: www.eaton.com Impedance: 4.7k ohms to +5V DC Voltage -- High: +3.7 to +24V DC Low: 0.0 to 0.9V DC Response: Minimum low 15 mS, minimum high 15 mS Relay Outputs PG05400001E Type: SPDT contacts UL Ratings: 250V AC, 360V A Pilot Duty Transistor Outputs (2) Type: NPN open collector with transient protection Maximum Voltage (OFF state): 30V DC Maximum Current (ON state): 200 mA @ 1.3V DC Communication Type: RS-485 Format: 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit Protocol: Opto-22 compatible Speed: 300, 1200, 2400, 4800, 9600 and 19200 baud Parity: Odd, Even, None (space transmitted, ignore received) Rate Indicator (Not available on models 57601-415 and 57601-485) Type: 1/Tau Digits: 6 Presets: 2 Scaler Range: 0.00001 to 99999 Decimal Point: 5 positions, programmable Accuracy: 0.015% of reading Update Time: See Table 41 Zero Time: See Table 41 Connections Type: Dual depluggable screw terminal strips Conductor Size: 14 - 22 AWG (2.1 - 0.38 mm2), 600V, solid, stranded, or fused (preferred) 43 44 Counters, Panel Meters, Tachometers and Timers Count Control April 2007 Ambassador Series -- Durant(R) Table 42. Ambassador Count Input Speeds -- 5760X405, 5760X415 Table 40. Output Latency for Ambassador Control Style Number Output Latency Solid-State A or B A and B 5760X401 5760X402 5760X403 0.7 to 2 mS 0.7 to 2 mS 0.7 to 2.7 mS A-B A+B -A + B 8250/8250 8250/8250 8000/8000 3000/3000 4000/4000 3000/3000 5760X404 5760X405 5760X415 0.7 to 2.7 mS < 1 mS < 1 mS A, B Dir 2A, B Dir A, B Rst 8000/40 4500/40 8250 -- -- -- Quad x 1 Quad x 2 Quad x 4 -- -- -- 3250 3250 2000 Tot A/Cnt B Tot + Cnt B 14000/9000 16000/8500 6500/6500 6500/6500 Table 41. Rate Indicator Specs for Ambassador Control Style Number Update Time Zero Time 5760X401 5760X402 5760X403 1 second, fixed 1 second, fixed 1 second, fixed 10 seconds, fixed 10 seconds, fixed 10 seconds, fixed 5760X404 5760X405 1 second, fixed 0.1 to 99.9 sec, programmable 0.1 to 999.9 sec, programmable 10 seconds, fixed 0.1 to 99.9 sec, programmable 0.1 to 999.9 sec, programmable 5760X415 Contact inputs = 40 Hz; B Direction inputs = 40 Hz and B Reset input = 10 S Min. Low. Input A not active on Feet/Inches control. Table 43. Ambassador Count Input Speeds -- 5760X401, 5760X402, 5760X403, 5760X404 Mode Input A/B Maximum Speed Solid-State (High Speed) Contact (Low Speed) Add/Sub Add/Add 20 kHz 20 kHz 40 kHz 40 kHz Count/Direction Count x 2/Direction 15 kHz 7.5 kHz 40 kHz -- Quadrature Quadrature x 2 6.5 kHz 6.5 kHz -- -- The maximum count speed depends on the selected count mode. All maximum speeds are shown with square waves (50% duty cycle) input. For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 Ambassador Series -- Durant(R) Product Selection Table 44. Product Selection -- Ambassador Series Count Control Description Catalog Number Single Preset with Rate, 115V AC Single Preset with Rate, Batch and Totalizer, 115V AC 57601401 57601402 Dual Preset with Rate, 115V AC Dual Preset with Rate, Batch and Totalizer, 115V AC 57601403 57601404 Four Preset with Rate, Batch and Totalizer, 10 - 15V DC Four Preset with Rate, Batch and Totalizer, 115V AC Four Preset with Rate, Batch and Totalizer, 230V AC 57600405 57601405 57602405 Feet/Inches Control, 115V AC Feet/Inches Control, 230V AC 57601415 57602415 * Dimensions Durant (R) C 123456 P1 10000 RST CLR RUN PGM PRNT EXIT ENT SEL 2.946 0.015 (74.83 0.38) * 5.60 0.03 (142.24 0.76) 2.946 0.015 (74.83 0.38) Gasket 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 Panel Cutout Max. Panel Thickness 0.50 (12.7) 2.677 0.028 (68.00 0.70) 2.677 0.028 (68.00 0.70) Figure 48. Ambassador Series Count Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 45 Counters, Panel Meters, Tachometers and Timers Count Control 46 April 2007 President Series -- Durant(R) Features Standards and Certifications Cat. No. 58831400 5- or 6-digit, LED display, 0.56" (14 mm) 1, 2 or 3 presets 15V DC @ 100 mA output power Rear panel screw terminals 20 mA current loop communications 2 Form C relays Tactile keypad NEMA 4 front panel UL Listed, CSA marked CE Marked Technical Data and Specifications Table 45. President Series -- Count Control Specifications Description Model 57820400 AC Power Requirements 120V 10% 57820401 58821400 58825400 240V 10% 58831400 120V/240V +10%/-20%, 47 - 63 Hz DC Power Requirements 11 - 30V DC 11 - 28V DC Power Consumption 8 Watts max. 18 Watts maximum DC Power Output 15V DC +1/-2 @ 85 mA max. 15V DC +1/-2; 150 mA if powered from AC or less than 24V DC, 100 mA if powered from 24V DC or greater Operating Temperature 32 to 130F (0 to 55C) Operating Humidity 85% relative, non-condensing Storage Temperature -10 to 160F (-40 to 71C) Front Panel Rating Main Counter Scaler Range Count Input Frequency NEMA 4 rating when mounted with gasket provided N/A 5 Digits (0.0001 to 9.9999) 10 kHz (5 kHz in Quadrature) See Table 46 See Table 52 Count Input Impedance 6.8 k1 to 15V DC when control is powered by AC line; 6.8 k1 to 10V DC when control is powered by DC line Control Input Threshold High 10.5 to 24.5V DC; Low 0.0 to 4.5V DC when powered by AC Control Input Impedance See Table 47 4.5 k1 to +5V DC Control Input Response Time Min. High 5.3 mS; Min. Low 3.9 mS Relay Contact Output Ratings SPDT Form C; 10 amps resistive @ 24V DC or 230V AC; 1/3 hp @ 115V AC or 230V AC; 150V DC max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating Transistor Output Ratings Open collector NPN transistor with Zener diode transient surge protection; 30V DC max. load; 300 mA max. per transistor; 480 mA total for all transistors. Use 5 mA per relay coil when calculating total transistor current Communications N/A Dual Port 20 mA current loop, Standard ASCII code DC power output is only regulated if unit is powered by AC or greater than 18.5V DC. For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 President Series -- Durant(R) Table 45. President Series -- Count Control Specifications (Continued) Description Model 58841400 58851400 58827400 AC Power Requirements 58827410 58867400 120V/240V +10%/-20%, 47 - 63 Hz DC Power Requirements 11 - 28V DC Power Consumption 18 Watts max. DC Power Output 15V DC +1/-2; 150 mA if powered from AC or less than 24V DC, 100 mA if powered from 24V DC or greater Operating Temperature 32 to 130F (0 to 55C) Operating Humidity 85% relative, non-condensing Storage Temperature -10 to 160F (-40 to 71C) Front Panel Rating NEMA 4 rating when mounted with gasket provided Main Counter Scaler Range 5 Digits (0.0001 to 9.9999) Count Input Frequency See Table 47 See Table 48 6 Digits (0.00001 to 9.99999) See Table 49 See Table 51 Count Input Impedance 6.8 k1 to 15V DC when control is powered by AC line; 6.8 k1 to 10V DC when control is powered by DC line Control Input Threshold High 10.5 to 24.5V DC; Low 0.0 to 4.5V DC when powered by AC Control Input Impedance See Table 50 4.5 k1 to +5V DC Control Input Response Time Min. High 5.3 mS; Min. Low 3.9 mS Relay Contact Output Ratings SPDT Form C; 10 amps resistive @ 24V DC or 230V AC; 1/3 hp @ 115V AC or 230V AC; 150V DC max switched voltage; 5,000,000 operations mechanical life, 100,000 operations at resistive rating Transistor Output Ratings Open collector NPN transistor with Zener diode transient surge protection; 30V DC max. load; 300 mA max. per transistor; 480 mA total for all transistors. Use 5 mA per relay coil when calculating total transistor current Communications Dual Port 20 mA current loop, Standard ASCII code DC power output is only regulated if unit is powered by AC or greater than 18.5V DC. Table 46. 58821400 Count Frequency Table 47. 58831400, 58841400, 58861400 Count Frequency Scale Factor Count Speed (Pulses per Second) Nominal Count Quadrature and/or Doubled Count Scale Factor Count Speed (Pulses per Second) Nominal Count Quadrature and/or Doubled Count < 1.0000 1.0000 1.9999 2.0000 9.0000 9.9999 6,250 7,500 5,000 6,250 2,500 2,000 < 1.0000 1.0000 1.9999 2.0000 9.0000 9.9999 5,000 7,500 4,000 6,000 2,000 1,500 3,125 3,750 2,500 3,125 1,250 1,000 2,500 3,750 2,000 3,000 1,000 750 Table 48. 58851400 Count Frequency Scale Factor < 1.0000 1.0000 1.9999 2.0000 9.0000 9.9999 PG05400001E Count Speed (Pulses per Second) Function 61 value = "0" Nominal Count Quadrature and/or Doubled Count Function 61 value = "1" Nominal Count Quadrature and/or Doubled Count 5,000 7,500 4,000 6,000 2,000 1,500 3,500 4,500 2,400 3,600 1,100 1,000 2,500 3,750 2,000 3,000 1,000 750 For more information visit: www.eaton.com 1,750 2,250 1,200 1,800 550 500 47 Counters, Panel Meters, Tachometers and Timers Count Control 48 April 2007 President Series -- Durant(R) Table 49. 58827400 Count Frequency Scale Factor 0.999 1.000 1.999 2.000 9.000 9.999 Table 50. 58867400 Count Frequency Count Speed (Pulses per Second) Count Up Count Down Quadrature 4,000 5,000 3,500 4,000 1,500 1,250 2,000 3,500 1,250 2,750 1,500 1,000 2,250 3,500 2,000 3,000 1,500 1,000 Count Mode Count Speed (Pulses per Second) X1 X2 X3 High Speed Low Speed 30,000 200 7,500 200 15,000 200 Note: The maximum count input frequency depends only on the selected count mode (doubled or quadrature x4). The maximum input frequencies shown are with square wave (50% duty cycle) input. Table 51. 58827410 Count Frequency Sample Scale Factor 0.0001 - 0.9999 1.0000 5.0000 9.9999 Count Speed (Pulses per Second) Typical Combinations of Features C1 = ON C1 = ON C2 = OFF C2 = ON C3 = OFF C3 = OFF RM = OFF RM = OFF C1 = ON C2 = ON C3 = ON RM = OFF C1 = ON C2 = ON C3 = OFF RM = ON C1 = ON C2 = ON C3 = ON RM = ON 6,000 9,000 4,500 1,500 2,300 3,500 1,000 500 2,600 4,000 2,000 750 2,000 3,000 750 550 3,000 4,500 2,250 1,000 C1: Counter #1; C2: Counter #2; C3: Counter #3; RM: Ratemeter. Table 52. 58825400 Count Frequency Scale Factor Count Speed (Pulses per Second) Nominal Count Quadrature and/or Doubled Count < 1.0000 4,200 2,100 1.0000 7,500 3,750 1.9999 3,450 1,720 2.0000 6,250 3,120 9.0000 2,500 1,250 9.9999 1,800 900 For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Count Control April 2007 49 President Series -- Durant(R) Product Selection Table 53. Product Selection -- President Series Count Control Description Totalizer Features Batch Counter Rate Scaler CropCut Main Counter Presets Digits Catalog Number 120V AC, No Communications 240V AC, No Communications Single Preset -- -- -- -- -- -- -- -- -- -- -- -- 1 1 1 1 1 1 5 5 5 57820400 57820401 58821400 Single Preset with Rate Dual Preset Dual Preset with Batch Dual Preset with Totalizer or Batch Counter -- -- -- -- -- -- -- -- -- -- 1 1 1 1 1 2 2 2 5 5 6 6 58825400 58831400 58841400 58851400 -- -- -- -- -- -- 1 3 3 1 3 1 ea. 1 ea. 2 6 6 6 6 58861400 58827400 58827410 58867400 Three Preset with Floating Pre-Warn Main Counter, Batch and Totalizer Presets Two Independent Count Registers High-Speed Count Control -- 30 kHz Max. -- -- * These models have, in addition to the main count register, a register that may be configured to be used as either a totalizer or single preset batch counter. These two functions are mutually exclusive. The Model 58827-400 has both a totalizer and a batch counter, each with a single preset. In addition, the batch counter may be configured as an additional totalizer with control instead of batch counter. The Model 58827-410 has two completely independent count input channels feeding two independent, single preset count registers. In addition, a third single preset register may be used as either a totalizer or a batch counter for one or both of the two main counters. Dimensions 5.433 0.04 (138 1.0) 0.735 0.02 (18.7 0.5) 2.677 0.03 (68 0.7) 2.62 0.025 (66.67 0.6) Recommended Panel Cutout 0.95 0.04 (24.1 1.0) 5.53 0.015 (140.5 0.4) 5.78 0.02 (146.8 0.5) 5.91 0.03 (150.1 0.8) 5.80 0.015 (147.3 0.4) Durrant 1 2 3 4 5 6 7 8 9 Preset Count 10 11 12 13 14 15 16 17 18 IN1 IN2 USE Preset 1 1 6 Preset 2 2 7 3 8 4 9 5 0 Count Function 3.04 0.015 (77.2 0.4) K1 K2 EXTERNAL FUSE! IN OUT K1 115/230V~ K2 50/60 Hz + + 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Reset Enter 5.38 0.02 (136.7 0.5) 6.25 0.02 (158 0.5) Figure 49. President Series Count Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Count Control 50 April 2007 PD-Q and PD-ER Series -- Durant(R) Product Selection Table 54. Product Selection -- PD-Q and PD-ER Series Predetermined Counters Cat. No. 5-Y-41433-*-PD-Q Product Description The PD-Q Series is a five-digit, true subtracting electric predetermined counter that features pushbutton operation of both predetermined count settings and reset. The predetermined count is set by holding the RESET button in and then depressing the easy to operate pushbutton selectors under each digit. The unit subtracts, one count for each contact closure or impulse and actuates a 4 ampere, 250V AC switch when zero is reached. The output signal from this switch can be used to halt or change the flow of items being counted, and/or operate other electrical apparatus. The counter returns to the predetermined number when the RESET button is depressed and it is immediately ready to control the next lot or batch. The PD-ER Series is identical to the PD-Q Series, except that it has electric reset (ER) for remote operation, allowing either local or remote use. Technical Data and Specifications Number of Digits: 5 Speed: 1000 cpm Window: Acrylic Shaft: Stainless Steel Frame: Zinc Alloy Die Cast Digit Size: 3/16 inch high by 7/64 inch wide (4.8 x 2.8 mm) Weight -- Series PD-Q: 0.53 Lb. (0.24 kg) Series PD-ER: 1.06 Lb. (0.48 kg) Finish: Dull Instrument Black with Red RESET Button Power Consumption -- Series PD-Q: 9 Watts Series PD-ER: Count Coil 9 Watts, Reset Coil 20 Watts Voltage Mounting Wire Leads Catalog Number Order Number 12 DC 24 DC 120 AC 240 AC Panel Panel Panel Panel Rear Rear Rear Rear 5-Y-41433-401-PD-Q 5-Y-41433-402-PD-Q 5-Y-41433-406-PD-Q 5-Y-41433-407-PD-Q 41433401 41433402 41433406 41433407 24 AC 12 DC 24 DC 120 AC Panel Base Base Base Rear Rear Rear Rear 5-Y-41433-408-PD-Q 5-Y-41469-401-PD-Q 5-Y-41469-402-PD-Q 5-Y-41469-406-PD-Q 41433408 41469401 41469402 41469406 240 AC 24 AC 12 DC 24 DC Base Base Base Base Rear Rear Side Side 5-Y-41469-407-PD-Q 5-Y-41469-408-PD-Q 5-Y-41470-401-PD-Q 5-Y-41470-402-PD-Q 41469407 41469408 41470401 41470402 120 AC 240 AC 24 AC 12 DC Base Base Base Panel Side Side Side Rear 5-Y-41470-406-PD-Q 5-Y-41470-407-PD-Q 5-Y-41470-408-PD-Q 5-Y-41625-401-PD-ER 41470406 41470407 41470408 41625401 24 DC 120 AC 240 AC 24 AC Panel Panel Panel Panel Rear Rear Rear Rear 5-Y-41625-402-PD-ER 5-Y-41625-406-PD-ER 5-Y-41625-407-PD-ER 5-Y-41625-408-PD-ER 41625402 41625406 41625407 41625408 * UL Recognized. When Ordering Specify When ordering PD-Q and PD-ER Series Predetermined Counters, specify Catalog Numbers according to the features selected. Dimensions 2.72 (69.0) 2.69 (68.2) 1.59 (40.5) 1.56 (39.7) 1.69 1.31 (42.8) (33.3) Dia. 0.14 (3.6) 3.00 (76.2) 3.38 (85.7) 3.38 (85.7) 3.00 (72.6) 2.97 (75.4) 1.56 1.18 (39.7) (30.1) 4.38 (111.1) 4.00 (101.6) Hole Dia. 0.13 (3.2) 3.06 (77.8) 1.69 (42.8) 2.69 (68.2) 1.63 2.00 (41.3) (50.8) 1.69 (42.8) 3.22 (81.8) 2.69 (68.2) Figure 50. PD-Q and PD-ER Series -- Approximate Dimensions in Inches (mm) Switch Rating: SPDT, 4 amperes at 250V AC Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters April 2007 Product Family Overview Introduction Ratemeters are used in a variety of applications where it is necessary to monitor the speed of a process. Conveyors, baking ovens, material flow and motor speed are typical uses for ratemeters. Eaton/Durant models with alarm outputs can be used to detect high or low rates. Rate indicators are often included as a standard feature on totalizers and count controls. 0 to 10V DC Feedback to Motor Drive Proximity Sensor High Alarm Output Motor Low Alarm Output Application Example One of the most common ratemeter applications is a tachometer. A tachometer displays motor or shaft RPM. The inductive proximity sensor detects the key on the shaft and the meter calculates the rate at which the shaft is turning based on a user-defined scaling factor. Signals from encoders, mag pick-ups, Hall effect sensors, etc. may also be used as inputs. Application Example Ratemeter Product Family Overview Table 55. Product Family Overview Product Family Characteristics Panel Cutout in Inches (mm) Page Number Compact device with bright, LED display Multiple functions available: count, time, rate, multifunction, 0.870 x 1.772 (22 x 44) 24 1.772 x 1.772 (45 x 45) 37 Economical, multifunction display Large, LED characters AC or DC power options 1.772 x 1.622 (45 x 92) 27 1.299 x 2.677 (33 x 68) 52 1.772 x 1.622 (45 x 92) 53 6-digit, high-visibility, 2-line LCD display User-configurable control inputs Highly flexible control/display 2.667 x 2.667 (68 x 68) 55 Bright LED display w/14 mm characters Simple configuration with 14-button tactile keypad Many different versions fit almost any application 2.667 x 5.433 (68 x 138) 30 Integrated controller combines operator interface, ladder logic 2.667 x 5.433 (68 x 138) 79 double-function E5-_24-E 24V DC Power Low cost, simple count control Various power options: battery, AC, DC Easy-to-change preset values 2-line display: input and preset values E5-148-C E5-496-C Courier Replaceable lithium battery 8-digit, high-visibility LCD display Optional backlighting Various input options available 6-digit, super bright LED display Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls Eclipse Ambassador President and high-speed counting Fusion PG05400001E For more information visit: www.eaton.com 51 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 52 April 2007 Courier Series -- Durant(R) Contents Description Tachometers/Ratemeters Courier Series . . . . . . . . . . . Eclipse Series . . . . . . . . . . . Ambassador Series . . . . . . Page 52 53 55 Operating Humidity: 60% R.H. (non-condensing) Weight: 2.2 oz. (62 g) net Display Size: 0.43" (10.9 mm) high Front Panel Rating: NEMA 4X when mounted with gasket provided Case Material: Cycolac X-17 Rate Indicator Courier Series Type: 1/Tau Digits: 4/5 (4 calculated, 5 displayed with fixed 0 in LSD) Scaler Range: 0.001 to 9999. Decimal Point: 5 positions, programmable Accuracy: 0.2% Update Time: 0.7 seconds Zero Time: 10 seconds Voltage Thresholds -- Low: 0 - 0.4V DC High: 2.0 - 28V DC Max. High: 28V DC Input A (Terminal 3) High speed input requiring a voltage source such as a current sourcing sensor or a current sinking sensor used with the provided pull up resistors Speed: 0 to 10 Hz Min. Low Time: 80 mS Min. High Time: 20 mS Note: The above times are with a 0 - 5.0V swing. Input Impedance: 2k Ohm above 5V DC Voltage Thresholds -- Low: 0 - 1.2V DC High: 2.0 - 28V DC Max. High: 28V DC DC Common (Terminal 1) Rate Inputs Features 1/Tau ratemeter Scaling capabilities Remote reset terminal 0.43 inch (10.9 mm) display Front panel reset NEMA 4X Standards and Certifications CE Marked Technical Data and Specifications Input B (Terminal 2) Low speed input designed for contact closures to DC common Speed: 0 to 20 Hz Min. Low Time: 10 mS Min. High Time: 40 mS Input Impedance: 101k Ohm Programmable Enable Input (Terminal 5) Operation: Level sensitive (maintained) Count Accuracy 100% when operated within Product Selection Table 56. Product Selection -- LCD 1/Tau Ratemeter Description Order Number Battery Extended Temperature Range, Battery Backlight, Battery 53300404 53301404 53302404 * Note: For units with Rate and Total, see Totalizers. Power Internal Battery: 3V, Lithium Life Expectancy: 5 years + Replacement Part: 35367-202 Dimensions 1.25 (31.8) Backlight 10 - 30V DC @ 30 mA max. Note: Derate operating temperature 1C/ Volt above 17V DC. Reverse polarity protected Physical Operating Temperature -- Model 53300-404: 32 to 131F (0 to 55C) Model 53301-404: -4 to 158F (-20 to 70C) Model 53302-404: 32 to 131F (0 to 55C) Storage Temperature: -4 to 158F (-20 to 70C) 2.95 (74.9) 2.67 (67.8) 1.57 (39.9) T/R Recommended Panel Cutout 1.30 (33.0) RST Figure 51. Courier Series Ratemeter -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters April 2007 Eclipse Series -- Durant(R) Features Standards and Certifications Cat. No. 57700470 1/8 DIN Cutout NEMA 4X Front Panel Universal AC Power Supply (85 - 265V AC) DC Power Modules (9 - 30V DC) Removable Screw Terminals Short Depth: 3.6 inch (91 mm) Front Panel Programming UL and cUL Listed, CE Marked Technical Data and Specifications Input Power Program Enable Input Environmental AC Powered Models (57701-4XX) -- Input Power: 85 - 265V AC, 47 - 63 Hz, 20V A External Fuse: 0.2A, 250V AC, Time Delay (T200 mA, 250V) Isolation Dielectric Strength: 2300V AC DC Powered Models (57700-4XX)-- Input Power: 9 - 30V DC, 12 VA External Fuse: 2.0A, 50V DC, Time Delay, (T2A, 50V) Reverse Voltage Protection: Yes Isolation Dielectric Strength: 2300V AC to signal inputs and relays, 500V AC to RS-485 and analog outputs Human Interface Display: 5 digits Type: 0.56" high, seven segment, red LED Indicator: One red LED program/ calibration indicator Update Time: 0.1 to 99.9 seconds minimum Data Retention Memory Type: EEPROM, no batteries required Duration: 100 years Signal Input Rate/Process Time: Signal In Sensor Type: Sink or source, DIP switch selectable Input Impedance: 4.75 k ohms to +5V DC or 34.9 k Ohms to ground Thresholds -- High 3.5 to 28V DC Low 0 to 1.9V DC, for single ended signals Magnetic Pickup Range: 200 mV p-p to 65 VRMS into 34.9 k Ohms Frequency Response: 200 Hz max. or 10 kHz max. (5V signals), DIP switch selectable PG05400001E Sensor Type: Sink only Input Impedance: 4.75 k Ohms to +5V DC Thresholds -- High 3.5 to 28V DC Low 0 to 1.9V DC Response: 25 mS max. (5V signal) Accessory Power Output Voltage: 12V DC 12% Current: 75 mA max. Protection: Short circuit protected Optional Outputs Relay Board -- Number of relays: 2 Contact type: 1 set form C per relay Contact rating: 5A, 250V AC or 30V DC Isolation dielectric strength: 2300V AC Analog Retransmission -- Output signals: 4 - 20 mA (<750 1) and 0 - 10V (>2500 1) Accuracy: 0.13% full scale and 100 PPM /C (and 0.07% full scale change over 4 - 20 mA load ranges) Isolation dielectric strength: 2300V AC to signal inputs, relays and AC power inputs; 500V AC to RS-485 and DC power inputs RS-485 Serial Communications -- Baud Rate: 1200, 2400, 4800, 9600, or 19,200, programmable Parity: Even, odd or no parity Address Range: 00 to 99 decimal Protocol: Opto 22(R) compatible Isolation Dielectric Strength: 2300V AC to signal inputs, relays and AC power inputs; 500V AC to analog outputs and DC power inputs For more information visit: www.eaton.com Operating Environment: Indoor use to 2000 meters Temperature -- Operating: 32 to 122F (0 to 50C) Storage: -4 to 158F (-20 to 70C) Humidity: 0 to 85% RH, noncondensing Vibration: 2.5 Gs, 30 to 200 Hz Shock: 30 Gs, 11 mS half sinewave EMC -- Immunity to EN 50082-2 (Heavy Industrial) Emissions to EN 50081-2 (Heavy Industrial) Front Panel: NEMA 4X when mounted with gasket provided CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution Degree 2: Overvoltage category II 53 54 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters April 2007 Eclipse Series -- Durant(R) Product Selection Table 57. Product Selection -- Eclipse Series 5-digit LED Ratemeter Description Catalog Number 9 - 30V DC 9 - 30V DC, Alarms 9 - 30V DC, Analog Out 9 - 30V DC, Alarms, Analog Out 57700470 57700471 57700472 57700473 9 - 30V DC, RS-485 9 - 30V DC, Alarms, RS-485 9 - 30V DC, Analog Out, RS-485 9 - 30V DC, Alarms, Analog Out, RS-485 57700474 57700475 57700476 57700477 85 - 265V AC 85 - 265V AC, Alarms 85 - 265V AC, Analog Out 85 - 265V AC, Alarms, Analog Out 57701470 57701471 57701472 57701473 85 - 265V AC, RS-485 85 - 265V AC, Alarms, RS-485 85 - 265V AC, Analog Out, RS-485 85 - 265V AC, Alarms, Analog Out, RS-485 57701474 57701475 57701476 57701477 * Dimensions (R) Durant 2.19 (55.6) 1.772 0.02 (45 0.6) PGM 4.04 (102.6) 3.622 0.031 (92.00 0.8) Panel Cutout Max. Panel Thickness 0.190 (4.83) 3.63 (92.2) 3.31 (84.1) 0.27 (6.9) Figure 52. Eclipse Series Ratemeters -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters April 2007 Ambassador Series -- Durant(R) Ratemeter Cat. No. 57150400 Type: 1/Tau Digits: 5 with overrange indication Scaler Range: 0.00001 to 99999 Decimal Point: 5 positions, programmable Average Time: 0.1 to 99.9 seconds, programmable Zero Time: 0.1 to 99.9 seconds, programmable Accuracy: 0.015% of reading Maximum Rate Input Frequencies Features AC/DC powered, 2-line LCD display 2-Line, 5-digit, high visibility, 0.3" (7.5 mm) characters, backlit display 1 or 2 rate inputs 2 rate alarms Dual rate unit ratio calculations -- A/B, A-B or draw Programmable average and zero times Programmable decimal point 12V DC, 100 mA max. output power Removable screw terminals RS-485 communications NEMA 4 front panel Standards and Certifications UL and cUL Listed, CE Marked Technical Data and Specifications Contact Input Sinking Sensor (All DIPs off): 7.3 kHz Sourcing Sensor (Push-Pull Output) -- High Threshold (DIPs 1 and 2 on, 3 and 4 off) -- - 0 - 5V, single input 50 kHz - 0 - 5V, two inputs 30 kHz (each input) - 0.5 - 4.5V, single input 40 kHz - 0.5 - 4.5V, two inputs 30 kHz (each input) - 0 - 15V, two inputs 22 kHz (each input) Low Threshold (All DIPs on) -- - - - - DC Power Output (AC Models Only) 12V DC (25%), 100 mA maximum (includes all line and load variations) 40 Hz Solid-State Input Power Input Model 57150-40X: 10 to 15V DC, 300 mA maximum Model 57151-40X: 115V AC (15%) 50 - 60 Hz, 7W Model 57152-40X: 230V AC (15%) 50 - 60 Hz, 7W All maximum frequencies listed are with a square wave input (50-50 duty cycle). -1 to +1V, single input 27 kHz -2 to +2V, single input 43 kHz )-3 to *+3V, single input 60 kHz )-2 to *+2V, two inputs 30 kHz (each input) Rate Inputs Sink -- Impedance: 4.6k ohms to +5V DC Voltage: High 3.5 to 34.0, low 0.0 to 1.9V DC Environment Operating Temperature: 32 to 131F (0 to 55C) Storage Temperature: -4 to158F (-20 to 70C) Operating Humidity: 85% Relative, non-condensing NEMA 4 rating when mounted with gasket provided PG05400001E For more information visit: www.eaton.com Source (High) -- Impedance: 2.3k ohms to common Voltage: High 3.5 to 17.0V DC, low 0.0 to 1.9V DC Source (Low) -- Impedance: 2.3k ohms to common DC Voltage: High 0.63 to 17.0V DC, low -17.0 to -0.6V DC AC Voltage: 17V AC (48V PeakPeak) maximum Control Inputs Impedance: 4.7k ohms to +5V DC Voltage: High +3.7 to +24V DC, low 0.0 to 0.9V DC Response: Min Low 15 mS, Min High 15 mS Transistor Outputs (x2 for 5715X-401; x4 for 5715X-405) Type: NPN open collector with transient protection Max. Voltage (OFF state): 30V DC Max. Current (ON state): 200 mA @ 1.3V DC Communication Type: RS-485 Format: 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit Protocol: Opto-22 compatible Speed: 300, 1200, 2400, 4800, 9600, 19200 Baud Parity: Odd, Even, None (space transmitted, ignore received) Analog Output (Models 5715X-401 Only) Range: 0 - 10V DC 0.2% at 5 mA DAC Resolution: 12 bit Connections Type: Dual depluggable screw terminal strips Conductor Size: 14 - 22 AWG (2.1 - 0.38 mm2), 600V, solid, stranded or fused (preferred) 55 Counters, Panel Meters, Tachometers and Timers Tachometers/Ratemeters 56 April 2007 Ambassador Series -- Durant(R) Product Selection Table 58. Product Selection -- Ambassador Series Ratemeters Description Catalog Number * Single Input LCD Rate indicator, 2 Rate Alarms, 10 - 15V DC LCD Rate indicator, 2 Rate Alarms, 115V AC LCD Rate indicator, 2 Rate Alarms, 230V AC 57150400 57151400 57152400 Dual Input Rate/Ratio/Draw with Alarms & Analog Out, 10 - 15V DC Rate/Ratio/Draw with Alarms & Analog Out, 115V AC Rate/Ratio/Draw with Alarms & Analog Out, 230V AC 57150405 57151405 57152405 The accuracy of the ratio calculation is dependent upon the resolution of the displayed rates, which are calculated as rounded integers. The ratio calculation treats the displayed rate as integers and the result is displayed as a rounded integer. A and B scalers should be adjusted for maximum resolution. Dimensions Durant (R) A 12345 R/M UNL CLR RUN PGM AKN EXIT ENT SEL 2.946 0.015 (74.83 0.38) * 5.60 0.03 (142.24 0.76) 2.946 0.015 (74.83 0.38) 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 Panel Cutout Max. Panel Thickness 0.50 (12.7) 2.677 0.028 (68.00 0.70) 2.677 0.028 (68.00 0.70) Figure 53. Ambassador Series Ratemeters -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Digital Panel Meters April 2007 Product Family Overview Introduction Application Examples Digital Panel Meters are found anywhere a process variable needs to be indicated. Volts, current, pressure, volume, temperature and frequency are typical applications. The product's short depth makes it flexible and accommodating to panel builder needs. A variety of input and output options allows Eaton/Durant DPMs to be used virtually anywhere. Monitor current draw from motor to identify potential failures Display pressure reading from transducer with highpressure alarm Display system voltage and detect under voltage or over voltage conditions Digital Panel Meters Product Family Overview Table 59. Product Family Overview Product Family Characteristics Panel Cutout in Inches (mm) Page Number 0.870 x 1.772 (22 x 44) 58 1.772 x 1.622 (45 x 92) 59 Bright, easy-to-read LED in 1/32 DIN package Programmable scaling of inputs Input for Display-Hold 24V DC power E5-324-E 6-digit, super bright LED display Multiple models available: DC Voltage, AC Voltage, DC Current, AC Current, 5A AC Current, 4 - 20 mA / 0 - 10V Process Meter Various output options including Relay, Analog and RS-485 Eclipse PG05400001E For more information visit: www.eaton.com 57 Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 58 April 2007 E5-324-E Series Contents Description Page Digital Panel Meters E5-324-E Series . . . . . . . . . . 58 Eclipse Series . . . . . . . . . . . 59 Cat. No. E5-324-E0402 Ambient Temperature: 14 to 122 F (-10 to 50C) EMC: According to EC EMC directive 89/36/EEC Interference Emissions: EN 61 000-6-4/ EN 55011 Class B Interference Resistance: EN 61 000-6-2 Protection: IP65 (front) Input Current Measurement: 0 - 20 mA, 4 - 20 mA, voltage drop max. 1.5V DC Input Voltage Measurement: 0 - 10V, 2 - 10V Input resistance approx.: 1 M1 Max. input signal level: 30V DC Control Inputs -- High: 4 - 30V DC Low: 0 - 2V DC Resolution: 14 bits Error: <0.1% For the whole measuring range at an ambient temperature of 68F (20C) Weight: Approx. 1.76 oz (50 g) Connection Technique: Screw terminal, pitch 0.2 Inch (5.08 mm), 7 poles Product Selection Table 60. Product Selection -- E5-324-E0402 Features Description Catalog Number LED Digital Panel Meter, 24 x 48 mm E5-324-E0402 Galvanic isolation with protection against incorrect polarity Automatic MIN/MAX value detection Freely programmable characteristic curve end points Input Range -- 1 current measuring input 1 voltage measuring input Compact display for analog standard signals Display range -19.999 to 99.999 with zero blanking Modern industrial design Input for Display-Hold Dimensions UL Recognized CE Marked 0.87 x 1.77 (22.0 x 45.0) 1.89 (48.0) Supply Voltage: 10 - 30V DC, galvanically isolated with integrated protection against incorrect polarity Current Consumption: Max. 50 mA Display: 5-digit display, red 7-segment LEDs; 0.31 Inch (8 mm) high Measuring Rate: 2 measurements/ second Data Backup: EEPROM Housing: Housing for control panel 1.898 x 0.94 Inch (48 x 24 mm); Acc. to DIN 43 700, RAL 7021, dark gray Connections: Panel Cut-Out: 0.87 + 0.01 x 1.77 + 0.02 (22.2 + 0.3 x 45 + 0.6) 0.16 (4.0) 0.26 (6.5) 2.32 (59.0) 2.09 (53.0) 1.10 (28.0) 1.97 + 0.02 (50 + 0.6) 0.98 x 1.97 (25 x 50) Technical Data and Specifications Max. 0.76 (19.3) 0.94 (24.0) Standards and Certifications * 0.98 + 0.02 (25 + 0.5) 0.04 (1.0) Panel Cut-Out 0.16 (4.0) 2.20 (56.0) 1.57 1.26 (40) (32) 1.97 + 0.02 (50 + 0.6) 0.98 x 1.97 (25 x 50) 0.04 (1.0) 1.26 + 0.004 (32 + 0.1) 0.98 + 0.02 (25 + 0.5) 0.16 (4.0) M3 Panel Cut-Out Figure 54. E5-324-E Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Digital Panel Meters April 2007 Eclipse Series -- Durant(R) Data Retention Memory Type: EEPROM, no batteries required Duration: 100 years Signal Input DC Voltage Models (5770X-40X) -- Range: 199.9 mV DC, 1.999V DC, 19.99V DC, 199.9V DC, DIP Switch Selectable Impedance: 1 M 1 (ohms) Overrange: 750V DC/530V AC except 220V DC/AC on 199.9 mV range Accuracy: 0.1% of reading, 0.03% FS, 0.5 digit, and 80 PPM/C AC Voltage Models (5770X-41X) -- Range: 199.9 mV AC, 1.999V AC, 19.99V AC, 199.9V AC, DIP Switch Selectable, all ranges true RMS Frequency: 40 to 1000 Hz Impedance: 1 M 1 (capacity coupled) Overrange: 750V DC/530V AC except 220V DC/AC on 199.9 mV range Accuracy: 0.5% of reading, 0.13% FS, 0.5 digit, 180 PPM/ C for crest factor = 1; plus 0.7% for crest factor = 1 to 3; and 2.5% for crest factor = 5 Cat. No. 57700400 Features 4 Full digits 1/8 DIN Size Red, LED display 0.56" (14 mm) high characters Scalable display Flashing alarms Maximum/minimum data hold Optional analog, relay and RS-485 outputs NEMA 4X Depluggable terminal blocks Standards and Certifications UL and cUL Listed, CE Marked Technical Data and Specifications Input Power AC Powered Models (57751-4XX) Input Power: 85 - 265V AC, 47 - 63 Hz, 20 VA External Fuse: 0.2A, 250V AC, Time Delay (T200mA, 250V) Isolation Dielectric Strength: 2300V AC DC Powered Models (57750-4XX) Input Power: 9-30V DC, 12 VA External Fuse: 2.0A, 50V DC, Time Delay (T2A, 50V) Reverse Voltage Protection: Yes Isolation Dielectric Strength: 2300V AC to signal inputs and relays, 500V AC to RS-485 and analog outputs Human Interface Display: 4 full digits Type: 0.56" (14 mm) high, seven segment, red LED Update Time: 0.4 seconds Alarm: Flashing display Indicator: One red LED program/ calibration indicator with max./min. capture and hold PG05400001E DC Current Models (5770X-42X) -- Range: 199.9 A DC, 1.999 mA DC, 19.99 mA DC, 199.9 mA DC, DIP Switch Selectable Impedance: 199.9 mV/selected range Overrange: 30 mA (1 99.9 A range), 100 mA (1. 999 mA range), 300 mA (19.99 mA range), 1 A (199.9 mA range) Accuracy: 0.1% of reading, 0.03% FS, 0.5 digit, and 120 PPM/C AC Current Models (5770X-43X) Range: 199.9 A AC, 1.999 mA AC, 19.99 mA AC, 199.9 mA AC, DIP Switch Selectable, all ranges true RMS Frequency: 40 to 1000 Hz Impedance: 199.9 mV/selected range (shunt output capacitive coupled) Overrange: 30 mA (11 99.9 A range), 100 mA (1.999 mA range), 300 mA (19.99 mA range), 1A (199.9 mA range) For more information visit: www.eaton.com Accuracy: 0.5% of reading, 0.13% FS, 0.5 digit, and 200 PPM/C for crest factor = 1; plus 0.7% for crest factor = 1 to 3; and 2.5% for crest factor = 5 5A AC Models (5770X-44X) -- Range: 5A AC, true RMS Frequency: 40 to 1000 Hz Impedance: 0.02 ohms (shunt output capacitive coupled) Overrange: 10A Maximum Accuracy: 0.4% of reading, 0.13% FS, 0.5 digit, and 200 PPM/C for crest factor = 1; plus 0.7% for crest factor = 1 to 3; and 2.5% for crest factor = 5 Process Models (5770X-45X) -- Range: 4 - 20 mA DC, 0 - 10V DC, 1 - 5V DC; separate input terminals for voltage and current signals Impedance: 100 1 (current input) and 1.27 M 1 (voltage input) Overrange: 50 mA maximum (current input) and 100V maximum (voltage input) Power Output: 24V DC 10%, 90 mA max, short circuit protected Accuracy: 0.1% of reading, 0.03% FS, 0.5 digit, and 80 PPM/C Optional Outputs Relay Board -- Dual relay: 1 set of form C contacts each Contact rating; 5A, 250V AC or 30V DC Isolation dielectric strength: 2300V AC Analog Retransmission -- Output Signals: 4 - 20 mA (<750 1) and 0 - 10V (>2500 1) Accuracy: 0.13% FS, 100 PPM/C, 0.07% FS change with 4 - 20 mA load, 0.3% FS for 4 - 20 mA output, only after exposure to 85% relative humidity Isolation dielectric strength: 2300V AC to signal inputs, relays and AC power input; 500V AC to RS-485 and DC power inputs 59 Counters, Panel Meters, Tachometers and Timers Digital Panel Meters 60 April 2007 Eclipse Series -- Durant(R) RS-485 Serial Communication -- Baud Rate: 1200, 2400, 4800, 9600 or 19,200, programmable Parity: Even, odd or no parity Address Range: 00 to 99 decimal Protocol: Opto 22(R) compatible Isolation Dielectric Strength: 2300V AC to signal inputs, relays, and AC power input; 500V AC to analog outputs and DC power inputs Catalog Number Selection Table 61. Eclipse Series Digital Panel Meters Numbering System 5 7 7 0 X - 4 X X Power Supply 0 = DC (9 - 30V DC) 1 = AC (85 - 265V AC) Input Option 0= 1= 2= 3= 4= 5= DC Volt AC Volt TRMS DC Amp AC Amp TRMS 5A AC TRMS Process (4 - 20 mA, 0 - 10V, 1 - 5V) 6 = Temperature (J, K, T, PT100 RTD) Environmental Operating Env.: Indoor use to 2000 meters Temperature -- Operating: 32 to 122F (0 to 50C) Storage: -4 to 158F (-20 to 70C) Humidity: 0 to 85% RH, noncondensing Vibration: 2.5 Gs, 30 to 200 Hz Shock: 30 Gs, 11 mS half sinewave EMC/EMI: Per EN 61326-1 Industrial Front Panel: NEMA 4X when mounted with gasket provided Agency Approval: CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and signal input lines. The shields were connected to earth ground at the Eclipse end of the shields. Conducted emissions requirements were met assuming that the AC signal input would not be connected directly to the AC Mains. The measurement error during RF immunity testing was less than 5% of full scale. In addition, models with an AC signal input had measurement error of less than +25% of full scale during RF immunity testing of the RS-485 at frequencies below 1 MHz. Pollution Deg. 2: Overvoltage Category II Output Option 0 = No Option 1 = Dual Relay 2 = Analog Output (4 - 20 mA and 0 - 10V) 3 = Dual Relay, Analog Output (4 - 20 mA and 0 - 10V) 4 = RS-485 Communications 5 = Dual Relay, RS-485 6 = Analog, RS-485 (4 - 20 mA and 0 - 10V) 7 = Dual Relay, Analog, RS-485 (4 - 20 mA and 0 - 10V) Output Options 0, 2, 4 are not available for models -41X and -43X. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Digital Panel Meters April 2007 Eclipse Series -- Durant(R) Dimensions (R) Durant 2.19 (55.6) 1.772 0.02 (45 0.6) PGM 4.04 (102.6) 3.622 0.031 (92.0 0.8) Panel Cutout Max. Panel Thickness 0.19 (4.8) 3.63 (92.2) 3.31 (84.1) 0.27 (6.9) Figure 55. Eclipse Series Digital Panel Meters -- Approximate Dimensions in Inches (mm) PG05400001E For more information visit: www.eaton.com 61 62 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters April 2007 Product Family Overview Introduction Application Examples Timers are used in applications where time itself is the main focus. These include simple knowledge of how long a machine has been running to determine machine maintenance, for example, (elapsed time) to knowing when to change an elevator cable (cable life and safety). Timers generally have the ability to stop and then to continue on from the point at which they stopped. Timer Relays are used in applications where an output is required to make something happen at a predetermined point in time (to stop or start the process). Elapsed time indication for interval maintenance of construction and agricultural equipment Usage metering for determining charges on rental equipment Controlled process timing for adhesive application/curing equipment Timers/Hour Meters Product Family Overview Table 62. Product Family Overview Product Family E5-224-C Characteristics Panel Cutout in Inches (mm) Page Number 0.870 x 1.772 (22 x 44) 63 0.870 x 1.772 (22 x 44) 24 1.772 x 1.772 (45 x 45) 68 Economical, multifunction display Large, LED characters AC or DC power options 1.772 x 3.622 (45 x 92) 27 Compact, low-cost LCD and electromechanical elapsed time Various 65 N/A 70 Non-replaceable battery (min. 8-yr. life) Compact, low cost and high efficiency 8-Digit LCD timer Manual or electrical reset Various timing modes (Hr/Min/Sec) Compact device with bright, LED display Multiple functions available: count, time, rate, multifunction, double-function 24V DC Power E5-_24-E Panel-mount, battery powered time relay 8 timing modes, 9 time ranges 3 programmable activation modes 8A relay contacts (N.O. or N.C.) E5-248-C E5-496-E meters Various power options for almost any power supply Hour Meters DIN Rail-mount, battery-powered time relay 8 timing modes 1 million operations or 10 years 10A contact rating E42DP55 For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters -- Electronic April 2007 1/32 DIN LCD -- Timers Contents Description Page Timers/Hour Meters -- Electronic 1/32 DIN LCD -- Timers . . . 63 E42DI24/E42DIR Series . . . 65 Timers/Hour Meters -- Electromechanical 1/16th DIN Hour Meters . . . 66 71.1 Round Hour Meter . . . 67 Time Controls Battery-Powered LCD . . . . 68 E42DP55 Battery Powered . . . . . . . . . . . . . . 70 Technical Data and Specifications Timer Inputs, High voltage version (10 - 260V DC/V AC) -- Timer input: Optocoupler input max. 30 Hz Min. pulse time: 16 mS Switching level -- Low: 0 - 2V DC/V AC High: 10 - 260V DC/V AC Counting start: For high signal at the timer input Time Range Change (Mode) -- Contact input -- Open collector (switching at 0V) NPN Low: 0 - 0.7V NPN High: 3 - 5V DC Time Range: Depending on the circuit Reset Input (Only DC and High Voltage) -- Minimum pulse time-- DC: 50 mS High Voltage: 10 mS Contact input (DC) -- NPN Low: 0 - 0.7V NPN High: 3 - 30V DC High voltage input: 10 - 260V DC/V AC Reset Locking Input (For DC and AC), Electrical Reset Key Locking -- Input not active: Reset key locked Contact input: Open collector NPN (switching at 0V) Switching level -- NPN Low: 0 - 0.7V NPN High: 3 - 5V DC Interference Emissions: EN 55011 Class B, EN 61 000-6-2, EN 61010 Section 1 (only AC versions) Housing; Dark gray RAL 7021 Operating Temperature: 14 to 131F (-10 to 55C) Ambient Temperature: 14 to 140F (-10 to 60C) Storage Temperature: -4 to 158F (-20 to 70C) Protection: IP65 (from front) Weight: Approx. 1.76 oz (50 g) Power Supply: Non-replaceable lithium battery (lifetime approximately 8 years at 68F (20C) Display: LCD, 8-digits, height of the figures 0.31 Inch (8 mm) Counting Direction: Adding Display Range -- Time Range: 99999 h 59 m (134) Display: Time Range: 99999.99 h (134) Display: Time Range: 9999 h 59 m 59 s (135) Display: Time Range: 9999999.9 s (135) Display: Cat. No. E5-224-C0440 Features Low price and high efficiency Large 8-digit LCD display, height of the figures 0.31 Inch (8 mm) Different time ranges from 0.1 second to 100,000 hours 0.1 second synchronization makes it suitable for very short activation times High voltage input for 10 - 260V AC/DC voltage pulses IP65 Screw terminals, RM 5 mm Lifetime of the battery approximately 8 years Locking of the reset key Operating temperature 14 to 140F (-10 to 60C) Reset: Manual and electrical Timer Inputs, DC versions (max. 30V DC) -- Timer input: NPN or PNP depending on the type Switching level -- NPN Low: 0 - 0.7V NPN High: 3 - 30V DC PNP Low: 0 - 0.7V PNP High: 4 - 30V DC Counting start -- NPN: For low signal at the timer input PNP: For high signal at the timer input Standards and Certifications UL Recognized CE Marked PG05400001E For more information visit: www.eaton.com 63 64 Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters -- Electronic April 2007 1/32 DIN LCD -- Timers Product Selection Table 63. Product Selection -- 1/32 DIN LCD, Timers Description Catalog Number * 8-digit LCD Timer, Battery Power Hours/Minutes, 0.94 x 1.89 Inch (24 x 48 mm) Hours/Minutes, 10 - 260V Input, 0.94 x 1.89 Inch (24 x 48 mm) Minutes/Seconds, 0.94 x 1.89 Inch (24 x 48 mm) Minutes/Seconds, 10 - 260V Input 0.94 x 1.89 Inch (24 x 48 mm) E5-224-C0440 E5-224-C0448 E5-224-C0450 E5-224-C0458 Dimensions MAX. 1.89 (19.3) 1.89 (48) 0.94 (24) 572690.43 0.87 x 1.77 (22 x 45) 0.11 (2.8) 1.88 (47.7) 0.12 (3) 1.77 + 0.024 (45 + 0.6) 1.77 + 0.012 (22.2 +0.3) Figure 56. 1/32 DIN LCD, Timers -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters -- Electronic April 2007 65 E42DI24/E42DIR Series -- Durant(R) Cat. No. E42DI24 Cat. No. E42DIR Input Impedance Minimum (Pins 3 and 4) -- E42DIXX1260X: 70k ohms E42DIXX48230X: 480k ohms Operating Temperature: -40 to 185F (-40 to 85C) Storage Temperature: -58 to 194F (-50 to 90C) Weight -- E42DIRXXXXXX: 1.94 oz (55 g) E42DI24XXXXXX: 0.78 oz (22 g) Product Selection Table 64. Product Selection -- E42DI24/E42DIR Series Elapsed Time Meters Features Solid-state hour meters Record and display up to 99,999.9 hours, rollover and continue timing EEPROM memory can retain data for 25+ years Time accumulation indicated by flashing hourglass icon Memory will arm only when power has been applied for 5 seconds Description Catalog Number * Round LCD Elapsed Hour Meter, 48 - 150V DC/100 - 230V AC Elapsed Hour Meter w/Reset, 48 - 150V DC/100 - 230V AC Elapsed Hour Meter, 12 - 48V DC/20 - 60V AC E42DIR48230 E42DIR48230R E42DIR1260 Rectangular LCD Elapsed Hour Meter, 48 - 150V DC/100 - 230V AC Elapsed Hour Meter, w/Reset, 48 - 150V DC/100 - 230V AC Elapsed Hour Meter, 12 - 48V DC/20 - 60V AC E42DI2448230 E42DI2448230R E42DI241260 Dimensions Standards and Certifications U Clamp for 0.03 - 0.25 (7.6 - 6.4) Panel Thickness UL recognized CE compliant Thumbnut 0.16 (4.0) Black Bezel Technical Data and Specifications QUARTZ HOURS 1 -- 10 Function: Solid-state hour meter Power Supply -- E42DIXX1260X: 12 - 48V DC 25%/ 20 - 60V AC 25% E42DIXX48230X: 48 - 150V DC +23% -25%/ 100 - 230V AC +17% -25% Frequency Range: 48 - 440 Hz Display: 6-digit LCD, 0.20" (5 mm) Accuracy: 0.1% Recording/Display Capacity: 99,999.9 hours Resolution: 0.1 hour (6 minutes) Current Consumption Max. @ Nominal Voltage E42DIXX1260X: 0.8 mA @ 12V DC 5.0 mA @ 48V DC 0.5 mA @ 20V AC 2.5 mA @ 60V AC E42DIXX48230X: 0.8 mA @ 48V DC 2.5 mA @ 150V DC 0.9 mA @ 100V AC 2.0 mA @ 230V AC Washer Terminal 0.25 (6.4) Max. Durant 0.35 (8.9) Max. Dia. 2.30 (58.4) Max. Dia. 2.06 (52.3) Max. 0.52 (13.2) Max. 1.40 (35.6) 0.06 (1.5) 1.13 (28.6) Max. 1.13 (28.7) Terminal 0.25 (6.4) +0.01 HOURS 0.89 (22.6) Durant 1.75 (44.5) 2.00 (53.1) 1/10 1.22 (31.1) 0.95 -0.00 +0.25 (24.1 -0.00) 0.93 (23.6) 0.18 (4.7) +0.01 0.71 (18) 1.45 -0.00 +0.25 (36.8 -0.00) Figure 57. E42DI24/E42DIR Series -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters -- Electromechanical 66 April 2007 1/16th DIN Hour Meters -- Eaton Cat. No. 7-T-65-4848PM-406 Features High shock resistance Without reset Small dimension Magnified figures Protection IP65 Data retention if power is lost Long service life Optional mounting position Time Meter -- AC: Fast rotating wheel with red dashes DC: 1/100 h display turns continuously by 1-digit in 36 sec. Test voltage: 2000V AC, 50 Hz for AC counters Options: Further voltages on request Color of Housing: Gray Height of Figures: 0.16 Inch (4 mm) Color of Figures: White and Red-onBlack Ambient Temperature: 5 to 122F (-15 to 50C) Mounting Position: Any Protection: IP65 Housing: Plastic Weight: 1.7 oz (48 g) Operating Indicator of the Running Product Selection Table 65. Product Selection -- 1/16th DIN Hour Meters Description Catalog Number * Electromechanical Hour Meters 10 - 30V DC, 1.89 x 1.89 Inch (48 x 48 mm) 10 - 30V DC, 1.89 x 1.89 Inch (48 x 48 mm), 50 pc. package 100 - 130V AC, 1.89 x 1.89 Inch (48 x 48 mm) 100 - 130V AC, 1.89 x 1.89 Inch (48 x 48 mm), 50 pc. package Accessory 8-T-65-4848PM-402 8-T-65-4848PM-40284 7-T-65-4848PM-406 7-T-65-4848PM-40684 1.91 (48.5) Applications General elapsed time Service interval for measurement systems -- Respiratory ventilators Oxygen machines Dialysis machines Small appliances UV lamps Display panels in cars 2.42 (61.5) Standards and Certifications UL Recognized Technical Data and Specifications Electrical Connection: Clamp terminal for cable diameter up to 14 AWG (2.5 mm2), tightening torque max. 0.59 lb-ft (0.8 Nm) Power Consumption -- 10 - 30V DC: Approx. 500 mW 100 - 130V DC: Approx. 750 mW Rated Voltages 100 - 130V AC, 50 or 60 Hz 10 - 30V DC On Time: 100% Display -- 7 at AC: 99999.99 8 at DC: 999999.99 Accuracy -- AC: Supply frequency + 30 mS DC: <0.003% (24 h) Count Mode: Adding 0.75 (19) 1.62 (41.1) Cat. No. T4848DINADAPT Figure 58. DIN Rail Adapter -- Approximate Dimensions in Inches (mm) Table 66. Product Selection -- DIN Rail Adapter Description Catalog Number DIN Rail Adapter for DIN Electromechanical Hour Meter T4848DINADAPT * Dimensions Dia. 1.97 (50) 1.89 (48) SQ. 0.35 (9) Max. 1.10 (28) 1.77+0.02 (45+0.6) 1.77 (45) SQ. 0.28 (7) Screw Terminal SQ. Panel Cut-Out Figure 59. 1/16th DIN Hour Meters -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Timers/Hour Meters -- Electromechanical 67 April 2007 71.1 Round Hour Meters -- Eaton Technical Data and Specifications Cat. No. 6-T-3H-508RPM-406 Features 6-digit hour meter for round panel cut-out Low cost High shock resistance Low power consumption Small dimension Magnified figures Waterproof Protection IP65 Data retention if power is lost Available in 50 pc. bulk package Applications General elapsed time Utility vehicles Construction machines Generators Fork-lift trucks Car washes Outside areas Electrical Connection: Flat pins 0.8 x 6.3 Power Consumption -- AC: Max., 0.4 VA 12V DC: Max., 0.08W 48V DC: Max., 0.7W Rated Voltages: 115V AC 10%, 50/60 Hz, 10 - 80V DC On Time: 100% Display: 6-digits, 99999.9 h Count Mode: Adding Height of Figures: 0.14 Inch (3.5 mm) Reset: None Ambient Temperature: -22 to 149F (-30 to 65C) Mounting Position: Any Protection: IP65 Housing: Plastic Error: <0.02% over the full range Product Selection Table 67. Product Selection -- 71.1 Round Hour Meters Description Catalog Number * Electric Hour Meters 115V AC, 2.80 Inch (71.1 mm) Round 115V AC, 2.80 Inch (71.1 mm) Round -- 50-piece Package 6-T-3H-508RPM-406 6-T-3H-508RPM-40684 10 - 80V DC, 2.80 Inch (71.1 mm) Round 10 - 80V DC, 2.80 Inch (71.1 mm) Round -- 50-piece Package 6-T-3H-508RPM-402 6-T-3H-508RPM-40284 Dimensions Dia. 2.54 (64.5) Dia. 2.44 (62) Dia. 0.15 (3.8) 120 0.03 x 0.25 (0.8 x 6.3) Dia. 0.13 (3.3) Dia. 2 (50.8) 1.68 (42.7) Dia. 2.80 (71.1) Dia. 2 (50.8) 0.47 (12) 1.26 (32) 0.21 (5.3) Panel Cut-Out Figure 60. 71.1 Round Hour Meters -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-2 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Time Controls 68 April 2007 Battery-Powered LCD Time Control, 48 x 48 mm -- Eaton Technical Data and Specifications Cat. No. E5-248-C1420 Features No external voltage supply, because of internal replaceable lithium battery High contrast, 2-line LCD display, 5-digit with many symbols for easy operation and reading 9 programmable time ranges from 0.20 seconds up to 99.999 hours Resolution up to 0.01 seconds Inputs for start and reset; universal inputs for 12 - 260V AC/DC 8 timing modes -- ON Delay, OFF Delay, One Shot and Single Shot Repeat cycle modes: Delay, Cycle, Symmetrical delay 3 programmable activation modes Relay contacts rated at 8A programmable to NO or NC Protection IP65 Plug-in connector Standards and Certifications Voltage Supply: 2 x 3V, 1/2AA replaceable lithium battery, service life > 10 years or 500,000 relay charges Timing and Reset Inputs: 12 - 260V AC/DC, impedance 180 k1, min. impulse 20 mS (optocoupler) Display -- Time: 5-digit LCD display, 0.26 Inch (6.5 mm) high Set Time Mode: 5-digit LCD display, 0.14 Inch (3.5 mm) high Accuracy: +50/-20 mS respectively 0.5% of setting time (higher value counts) 0.3% of setting time Operating Temperature: 14 to 122F (-10 to 50C) Storage Temperature: -4 to 158F (-20 to 70C) Relative Humidity: 80% max. up to 89F (31C); decreasing to max., 50% to 104F (40C) Protection: IP65 with delivered seal CE Marked Output Relays -- Contact connection: SPTST voltage free contacts programmable as NO or NC Contact rating: 250V AC at 8A; cos o = 1 250V AC at 5A; cos o = 0.4 30V DC at 8A; cos o = 1 Reaction Time: < 20 mS Expected Life: 2A ohm's load 1,000,000 switching cycles EMC: CE-conform to EC-guideline 89/36/EWG Electromagnetic Radiation: EN 61000-6-4/EN 55011 Class B Electromagnetic Immunity: EN 61-000-6-2 Weight: Approx. 2.8 oz (80 g) Time Ranges -- 1 - 99999 sec; 0.2 - 9999.9 sec; 0.02 - 999.99 sec 1 - 99999 min; 0.1 - 9999.9 min; 0.01 - 999.99 min 1 - 99999 hour; 0.1 - 9999.9 hour; 0.01 - 999.99 hour Timing Modes Level Trig Edge Trig Level Trig Edge Retrig Edge Trig Start Start ON Delay Repeat Cycle Delay Relay Edge Retrig Reset Reset t t t Relay t t+ t- t+ t- t+ t- t+ t+ t- t+ t- t+ Start Start Repeat Cycle OFF Delay Reset Reset t Relay t t Relay t t+ Start Repeat Cycle Symmetrical Delay One Shot Reset Reset t pw t t Relay t pw =t =t =t =t =t =t =t =t =t =t pw pw Start Start Repeat Cycle Symmetrical Single Shot Relay t- t+ Start Relay t+ t t =t t t t =t =t =t =t Figure 61. Timing Modes For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Time Controls April 2007 Battery Powered LCD Time Control, 48 x 48 mm -- Eaton Product Selection Table 68. Product Selection -- Battery-Powered Time Control Description Catalog Number Battery-Powered LCD Time Control, 1.89 x 1.89 Inch (48 x 48 mm) E5-248-C1420 * Dimensions 1.89 (48) 1.89 (48) 0.41 (10.5) Max.; 0.37 (9.5) at Front Panel 1.77 (45) 0.63 (16) 2.49 (63.2) 0.12 (3) Figure 62. Battery-Powered LCD Time Control, 48 x 48 mm -- Approximate Dimensions in Inches (mm) Note: Panel Cut-Out is 177 + 0.02 Inch Sq. (45 +0.6 mm Sq.). Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 69 Counters, Panel Meters, Tachometers and Timers Time Controls 70 April 2007 E42DP55 Battery Powered, DIN Rail Mounted Display Output Relays 2 rows of 3 digits, black on silver LCD Upper row 0.275" (7 mm) indicates time Lower row 0.157" (4 mm) indicates set point Power Supply Two 1/2AA 3V lithium batteries 10 year expected life (the built-in batteries are sealed for life and are not replaceable Timing Input Repeat Accuracy 12 - 260V opto-isolated inputs Selectable sink (NPN) or source (PNP) if using DC input device Input Impedance: 220k ohm Level or edge triggered Minimum pulse width of 20 mS Cat. No. E42DP55 Digital time control with 8 timing modes Battery powered -- 1 million operations or 10 years Battery included DIN Rail mounted 0.2 Seconds to 999.99 hours Easy-to-read LCD display with mode annunciators +50 -20 mS or 0.5% of set time (whichever is greater) Temperature -- 0.3% of set time Setting Accuracy Features Contacts: SPDT voltage free contacts Contact Rating: 10A 380V or 220V Power Rating: 2000VA/150W Reaction Time: <20 mS Mechanical Life: 10,000,000 operations Electrical Life -- 100,000 operations @ 8A (resistive load) 1,000,000 operations @ 2A (resistive load) Operating: 14 to 140F (-10 to 60C) Storage: -4 to 158F (-20 to 70C) Product Selection Table 69. Product Selection -- E42DP55 Battery-Powered Time Control Description Catalog Number Battery-Powered Time Control, DIN Rail Mounted E42DP55 * Dimensions Technical Data and Specifications Operating Modes ON Delay OFF Delay Cycle One-Shot Single-Shot Repeat Cycle Delay Repeat Cycle Repeat Cycle Delay = Repeat Cycle = 3.40 (86.3) Time Setting Ranges 1 - 999, 1 - 99.9 sec. 1 - 999, 0.1 - 99.9, 0.01 - 9.99 min. 1 - 999, 0.1 - 99.9, 0.01 - 9.99 hrs. 0.89 (22.5) 3.94 (100.0) Figure 63. E42DP55 Time Control -- Approximate Dimensions in Inches (mm) Note: The E42DP55 is designed to snap mount to any standard 35 mm DIN Rail. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls 71 April 2007 Product Family Overview Introduction Flow products are used in a variety of applications where liquid gas flow needs to be monitored or controlled. Eaton offers models for flow total, flow rate and flow batch control. Several optional outputs allow great flexibility to meet most application needs. Flow Sensor T/R Application Example Durant (R) RST 53300-405 Totalizer/Ratemeter In many processes, it is desirable to know both the total quantity of product being produced and the rate at which the product is being produced. Liquid In the illustration at right, the output of a turbine flow sensor is connected to a totalizer/ratemeter. The flow sensor produces a known number of pulses per gallon (or other unit of measure). The instrument scales these pulses into the desired units of flow volume (gallons, liters, barrels, etc.), and flow rate (gallons/minute, barrels/hour, etc.). Application Example Flow Totalizers/Controls Product Family Overview Table 70. Product Family Overview Product Family Characteristics Typical Applications Portable/mobile/remote flow monitoring 1.299 x 2.677 (e.g. sewer pumping, pesticide application) (33 x 68) 25 Length measurement and control 1.772 x 1.622 (45 x 92) Flow monitoring and control Process monitoring and display Voltage and current monitoring and display 72 Replaceable lithium battery 8-digit, high-visibility LCD display Optional backlighting Various input options available Panel Cutout in Inches (mm) Page Number Courier 6-digit, super bright LED display Multiple models available: totalizers, ratemeters, count controls, digital panel meters and flow controls Eclipse PG05400001E For more information visit: www.eaton.com Counters, Panel Meters, Tachometers and Timers Flow Totalizers, Transmitters and Controls 72 April 2007 Eclipse Series -- Durant(R) Data Retention Memory Type: EEPROM, no batteries required Duration: 100 years Count Signal Input/Count Inhibit Signal Input Cat. No. 57750-400 Features 6- or 10-digit display 1/8 DIN Size Red, LED display 0.56" (14 mm) high characters Scalable display Analog or pulse input versions Accessory power output 15-point linearization available Dual valve pre-warn available Optional analog, relay and RS-485 outputs NEMA 4X Depluggable terminal blocks Standards and Certifications UL and cUL Listed CE Marked Technical Data and Specifications Input Power AC Powered Models (57751-4XX) Input Power: 85 - 265V AC, 47 - 63 Hz, 20 VA External Fuse: 0.2A, 250V AC, Time Delay (T200mA, 250V) Isolation Dielectric Strength: 2300V AC DC Powered Models (57750-4XX) Input Power: 9 - 30V DC, 12 VA External Fuse: 2.0A, 50V DC, Time Delay (T2A, 50V) Reverse Voltage Protection: Yes Isolation Dielectric Strength: 2300V AC to signal inputs and relays, 500V AC to RS-485 and analog outputs Human Interface Display: 6 digits Type: 0.56" high, seven segment, red LED Sensor Type: Sink or source, DIP switch selectable Input Impedance: 4.75k ohms to +5V DC or 34.9 k Ohms to ground Thresholds -- High 3.5 to 28V DC Low 0 to 1.9V DC, for single ended signals Magnetic Pickup Range: 50 mV p-p to 65 VRMS into 34.9 k Ohms Slow Response: 50 Hz max. (DIP switch 2 and/or 5 ON) Flat Response: 10 kHz Flow Signal Input (Analog Input Models) Types: 4 - 20 mA and 0 - 10V DC Input Impedance: 100 ohms (current input), 1.27M ohms (voltage input) Overrange: 50 mA max (current input), 100V max (voltage input) Accuracy: 0.1% of reading, 1 digit, and 80 PPM/C Control Inputs Sensor Type: Sink only Input Impedance: 4.75k ohms to +5V DC Thresholds -- High 3.5 to 28V DC Low 0 to 1.0V DC Response: 25 mS maximum (5V signal) OFF State Block: 30V DC max., 0.1 mA max. leakage current ON State Conduct: 50 mA max., 1.2V DC max. C-E drop Max. Switching Frequency: 4 kHz (50-50 duty cycle) Isolation dielectric strength: 2300V AC Optional Outputs Analog Retransmission -- Output signals: 4 - 20 mA (<750 1) and 0 - 10V (>2500 1) Accuracy: 0.13% full scale and 100 PPM/C (and 0.07% full scale change over 4 - 20 mA load ranges Isolation dielectric strength: 2300V AC to signal inputs, relays and AC power inputs; 500V AC to analog outputs and DC power inputs RS-485 Serial Communications Baud Rate: 1200, 2400, 4800, 9600, or 19,200, programmable Parity: Even, odd or no parity Address Range: 00 to 99 decimal (00 indicates off line) Protocol: Opto 22(R) compatible Isolation Dielectric Strength: 2300V AC to signal inputs, relays and AC power inputs; 500V AC to analog outputs and DC power inputs Environmental Accessory Power Output (Pulse Input Models) Voltage: 12V DC +10%/-13% Current: 75 mA max. Protection: Short circuit protected Accessory Power Output (Analog Input Models) Voltage: 24V DC 10% Current: 90 mA max. Protection: Short circuit protected Relay/Transistor Outputs (standard on batch controls, optional on totalizers) Number: 2 relays or 1 relay and 1 transistor Relay Contact Type: 1 set form C per relay Relay Contact Rating: 5A, 250V AC or 30V DC Transistor Type: NPN, Opto Isolated For more information visit: www.eaton.com Operating Environment: Indoor use to 2000 meters Temperature -- Operating: 32 to 122F (0 to 50C) Storage: -4 to 158F (20 to 70C) Humidity: 0 to 85% RH, noncondensing Vibration: 2.5 Gs, 30 to 200 Hz Shock: 30 Gs, 11 mS half sinewave EMC -- Immunity to EN 50082-2 (Heavy Industrial) Emissions to EN 50081-2 (Heavy Industrial) Front Panel: NEMA 4X when mounted with gasket provided Agency Approval -- CE EMC immunity and emissions requirements were met using shielded wiring on the RS-485, analog output and pulse input/ power lines. The shields were connected to earth ground at the Eclipse end of the shields. Pollution Degree 2: Overvoltage Category II PG05400001E Counters, Panel Meters, Tachometers and Timers Flow Totalizers/Transmitters & Controls April 2007 Eclipse Series -- Durant(R) Catalog Number Selection Table 71. Eclipse Flow Model Numbering System 5 7 7 5 X - 4 X X Output Option Power Supply 0 = DC (9 - 30V DC) 1 = AC (85 - 265V AC) 0 = No Option 1 = Dual Relays (Standard or Batch) 2 = Analog Output (4 - 20 mA and 0 - 10V) 3 = Dual Relays and Analog Output 4 = RS-485 Communications 5 = Dual Relay and RS-485 6 = Analog Output and RS-485 7 = Dual Relays, Analog Output and RS-485 A = One Relay, One Transistor B = One Relay, One Transistor, Analog Output C = One Relay, One Transistor, RS-485 D = One Relay, One Transistor, Analog Output and RS-485 Input Option 0 = Pulse Input Totalizer/Ratemeter 1 = Pulse Input Batch Control 2 = Analog Input Totalizer/Ratemeter 3 = Analog Input Batch Control Output Options 0, 2, 4 are not available for models -41X and -43X. Dimensions (R) Durant 2.19 (55.6) BATCH 1.772 0.02 (45 0.6) PGM PGM View Enter Edit Start Stop Reset 4.04 (102.6) 3.622 0.031 (92.00 0.8) Panel Cutout Max. Panel Thickness 0.190 (4.83) 3.63 (92.2) 3.31 (84.1) 0.27 (6.9) Figure 64. Eclipse Flow Models -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 73 74 Counters, Panel Meters, Tachometers and Timers Special Function Controls April 2007 Basic Monitor Control Contents Description Special Function Controls Basic Monitor Control . . . . Position Control . . . . . . . . . Ambassador Series Closed-Loop Speed Control . . . . . . . . . . . . . . . . Page 74 75 77 Cat. No. 54420400 is to supply an output signal to the shear to cut the stock at a certain "preset" length, then reset itself and start measuring the next piece, and continue to do so until the desired number of pieces have been cut. Modern counters provide two other functions. The first is the slowdown, or "prewarn" output. The motor that drives the stock through the machine usually is run at a high speed until just before the cutoff occurs. A prewarn output from the counter to the drive drops the motor speed so that the feed rate for the stock slows to a "creep" speed that is maintained until the final cutoff preset is reached. Due to variations in feed speed and shear response, this creep speed is necessary for achieving a consistent cut length. The second additional function of the counter is to count the number of pieces that are cut and stop the machine when a preset number of pieces is reached. This is done by a second count register, called the batch counter, inside the counter. Cat. No. 56460400 Product Description 16 NPN outputs 24V DC @ 800 mA and 15V DC @ 200 mA output power RS-232 communications 85 - 265V AC and 24V DC input power models Optional configuration software available NEMA 4 accessory kit Standards and Certifications UL and cUL Listed, CE Marked Product Selection Table 72. Product Selection -- Basic Monitor Control Description Catalog Number Basic Monitor Control 54420400 500 Level Sequence Controller 56460400 5.38 (136.7) BASIC Monitor Control The 6460 sequential control can be thought of as a counter and/or timer with 500 presets. Most users load a number of programs or "recipes" into the 6460 and have the operator select one recipe at a time to run. The 6460 is often found in roll forming and coil winding applications and is used on induction heat treating scanners. 6-digit, LED display 0.56" (14.2 mm) high characters User defined operation Utilizes BASIC language Outputs 4 NPN transistors 2 form-C relays 1 pulse-width modulated 8 input lines 8k bytes of programmable memory 15V DC, 100 mA maximum output power 20 mA current loop communication Accepts 115/230V AC and 11 - 16V DC input power NEMA 4 front panel 500 Level Sequence Controller Application Description Cut-to-Length Application 500 programming levels 32-character 2 line LCD display 0.315" (8 mm) high characters 17 programmable count modes 4 programmable jump inputs Millisecond timing Count scaling Rate, total and batch count * Dimensions Features The BASIC monitor control (BMC) has two count inputs. Eight other rear terminal inputs and the fourteen front panel keys are user definable. The same is true for the two relay and five transistor outputs. Configuration is done through a BASIC language program entered by the user, putting the BMC in specialized control applications where dedicated count controls are not as well suited. In a "typical" cut-to-length application, raw stock is pulled from a coil through straightening rollers, and fed past a pneumatic shear. A quadrature encoder riding on the stock sends pulses to a counter that "measures" the amount of stock fed. The primary counter function 2.62 (66.7) 3.04 (77.2) 5.80 (147.3) 5.91 (150.1) Panel Cutout: 5.433 x 2.677 (138 x 68) Figure 65. Dimensions -- 54420400 Approximate Dimensions in Inches (mm) 7.24 (183.9) 6.18 (157.0) 5.35 (135.9) 8.07 (205.0) 3.74 (95) Panel Cutout: 7.32 x 5.43 (186 x 138) Figure 66. Dimensions -- 56460400 Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Special Function Controls 75 April 2007 Position Control Technical Data and Specifications Cat. No. 58868400 Power Input Communication AC Operation: 120/240V AC 10%, -20%), 47 to 63 Hz DC Operation: 11 to 16V DC (0.7 Amp max.) Power Consumption: 18 Watts maximum DC Power Output Product Description 15V DC (+1, -2), 100 mA maximum Environment The 58868400 closed-loop position control provides digital output signals (run, direction and fast/slow) to a drive to cause a motor-driven tool to be positioned along a single axis. These signals can also be used to control values in a hydraulic positioning system. Typically, a quadrature encoder, coupled to the drive mechanism, provides the feedback signal to the position control. Up to five destinations can be automatically sequenced through in a move-and-dwell process, or the operator can select a single destination for move-and-stop positioning. Features Input Voltage 6-digit, LED display, 14 mm (0.56") high characters 4 move registers plus home 2 Form C relays and 5 NPN transistor outputs 28 kHz count speed 5 dwell time settings 15V DC @ 100 mA power output Manual or automatic operation Programmable offset, prewarn and kerf values Backlash compensation Programmable high/low limits 20 mA current loop communications NEMA 4X front panel Standards and Certifications UL Listed Operating Temperature: 32 to 130F (0 to 55C) Storage Temperature: -40 to 160F (-40 to 71C) Operating Humidity: 85% relative, non-condensing. NEMA 4 rating when mounted with gasket provided Input Frequency The maximum input frequency only on the selected quadrature operation Quadrature Selection Control Input Response High Speed Low Speed Start/Stop: 1 mS Go home input: 5 mS Load Position: 5 mS Reference Input: 1.7 mS Count Inputs -- High: 10.5 to 24.5V DC Low: 0 to 4.5V DC Control Inputs -- High: 3.8 to 15.0V DC Low: 0 to 1.2V DC Input Impedances Count Inputs: 6.8 k1 to +15V DC (2.2 mA at 0V DC) Control Inputs: 2.2 k1 to +5V DC (2.3 mA at 0V DC) Relay Outputs (2) Type: Form C contacts Load Voltage: up to 240V AC or 280V DC Load Current: 5A resistive, 1.5A at 80% PF Transistor Outputs (5) PG05400001E Type: 20 mA loop (active transmit, passive receive) Speed: 110, 300 or 1200 Baud Parity: Odd, even, space Format: 1 start bit, 7 data bits (ASCII), 1 parity bit, 1 stop bit (110 baud uses 2 stop bits) Load Voltage: 30V DC maximum Load Current: 300 mA maximum Saturation: 1.5V max. @ 300 mA Latency: 150 + 5 S/1 kHz input speed 10 Type: NPN open collector with surge protection Load Voltage: 30V DC maximum Load Current: 300 mA maximum Saturation: 1.5V max. @ 300 mA Latency: 150 + 5 S/1 kHz input speed 10 S For more information visit: www.eaton.com X1 X2 X4 28 kHz 14 kHz 7 kHz 150 Hz 150 Hz 150 Hz Low speed jumper installed. Note: Only function 60 and the double jumper affect the maximum input speed. The scale factor does not affect the input speed. Position Control Features Setpoints: Four move setpoints plus one home setpoint Range for all setpoints is -99999 to 999999 Decimal Point: Four positions, programmable Dwell Times: Five, one for each setpoint. Dwell time range is 00.01 to 99.98 seconds. Scale Factor: Scale factor range is 0.00100 to 9.999999. Accuracy: 100% when the position control is operated within the specified speeds and input voltages 76 Counters, Panel Meters, Tachometers and Timers Special Function Controls April 2007 Position Control Product Selection Table 73. Product Selection -- Position Control Description Catalog Number Single-Axis Position Control 58868400 * Dimensions 5.80 (147.3) 5.38 (137) 588904 Durant MOVE POSITION RUN 1 2 3 4 5 6 7 8 9 MOVE K1 10 11 12 13 14 15 16 17 18 IN1 IN2 K2 DWELL HOME 1 2 3 4 5 RECALL FAST JOG+ JOG- POSITION 6 7 8 9 0 +/DWELL FUNCTION START STOP ENTER 2.62 (66.7) 3.04 (77.2) + K1 NO C NO K2 AC INPUTS 19 20 21 22 23 24 25 26 27 5.91 (150) Recommended Panel Cutout: 5.43 W x 2.68 H (137.9 x 68.1) Gaskets Pt. #28720-216 (Standard) Pt. #28720-217 Note: 1 gasket standard. 2nd gasket and Panel spacer optional. Use of optional spacer and gasket Spacer reduces unit depth from 5.91 (150) Counter to 5.38 (137.3). Front Spacer Kit Pt. #38820-400 Bezel NC C NO 28 29 30 31 32 33 34 35 36 Panel mounting clip fits into four square holes in side of counter. Figure 67. President Series Position Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Special Function Controls April 2007 Ambassador Series Closed-Loop Speed Control Technical Data and Specifications Power Input Control Outputs 57401-40X: 115V AC (15%) std., 50 to 60 Hz, 0.2A 57402-40X: 230V AC (15%) opt., 50 to 60 Hz, 0. 1A DC Power Output Cat. No. 57401400 12V DC (10%), 125 mA maximum (includes all line and load variations) Type: NPN open-collector with transient protection Max. Voltage (OFF state): 30V DC Max. Current (ON state): 200 mA at 1.3V DC Drive Signal Environment Product Description The Ambassador speed control provides a tightly regulated, isolated, 0 - 10V speed reference signal to a drive. It is most often used in follower mode applications, such as conveyor speed matching/mis-matching, cable production lay control, cable take-up reel traversing mechanism speed control and many others. In master mode, it is most commonly used for constant web speed take-up roll control, where the increasing roll diameter requires constant motor slowing over the course of filling a roll. Also, where feedback scaling and presets are required in units other than RPM or Hz. For instance, using a flowmeter as the feedback sensor, control the speed of a motor-driven pump in units of gallons/ minute. The two preset version offers additional features, such as reversing, and remote preset adjustments by "bumping" external pushbuttons. Features 2-line, 16-character, alphanumeric, high visibility, LCD backlit, 7.5 mm [0.3"] high character display 1 or 2 speed presets Isolated 1 - 10V DC analog out Selectable master/slave/jog modes Proportional integral error correction 35 kHz frequency inputs 0.015% speed regulation 12V DC @ 125 mA power output 12-Bit DAC resolution RS-485 serial communications NEMA 4X front panel Operating Temperature: 32 to 131F (0 to 55C). Storage Temperature: -4 to 158F (-20 to 70C). Operating Humidity: 85% Relative, non-condensing NEMA 4X rated when mounted with gasket provided Speed Regulation (Closed Loop) Accuracy: 0.015% Update Time: 5 mS Frequency Inputs Current Sinking -- Impedance: 4.75K Voltage Maximum: 24V DC High threshold: 3.5V DC Low threshold: 1.9V DC Pulse Rate: 1 Hz - 35 kHz Magnetic -- Impedance: 16 k min. Voltage -- - Maximum: 65V AC rms - Maximum: 200 mV p-p Pulse Rate: 1 Hz - 35 kHz Control Inputs Impedance: 4.75k ohms to +5V DC Voltage -- High: +3.7 to +24V DC Low: 0.0 to 0.9V DC Response: 40 Hz maximum Standards and Certifications UL Listed PG05400001E For more information visit: www.eaton.com Separate power supply with 1500V AC isolation 5740X-400: - Resolution: 12 bits - Full Scale Voltage: 10V DC minimum into 5 mA 5740X-401: - Resolution: 12 bits - Full Scale Voltage: 10V DC minimum into 5 mA; Drive Reference potentiometer allows full scale voltage to be reduced to less than 3V DC Communication Type: RS-485 Format: 1 start bit, 1 parity bit, 1 stop bit, seven-bit ASC I I characters Protocol: Opto-22 compatible Speed: 300, 1200, 2400, 4800, 9600 and 19200 baud Parity: None Connections Type: Unpluggable screw terminal strips Conductor Size: 14 - 22 AWG (2.1 - 0.38 mm2) 600V solid, stranded or fused (preferred) 77 78 Counters, Panel Meters, Tachometers and Timers Special Function Controls April 2007 Ambassador Series Closed-Loop Speed Control Product Selection Table 74. Product Selection -- Closed Loop Speed Control Description Catalog Number 1 Preset, 115V AC 2 Presets, 115V AC 57401400 57401401 1 Preset, 230V AC 2 Presets, 230V AC 57402400 57402401 * Dimensions SPEED 250 F/M PGM VIEW 2.946 0.015 (74.83 0.38) STEP CLR ADJ * EXIT ENT SEL 5.60 0.03 (142.24 0.76) 2.946 0.015 (74.8 0.38) Gasket 1 2 3 4 5 6 7 8 9 10 11 12 34 33 32 31 30 29 28 27 26 25 24 23 13 14 15 16 17 18 19 20 21 22 Panel Cutout Max. Panel Thickness 0.50 (12.7) 2.677 0.028 (68.00 0.70) 2.677 0.028 (68.00 0.70) Figure 68. Closed Loop Speed Control -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Fusion (R) Integrated Machine Control April 2007 Features and Benefits Features Cat. No. 57550400 User-configurable operator interface with back-lit LCD display and 18button tactile feedback keypad High speed counter with 5 presets and prewarn, totalizer, batch counter and ratemeter 10 parameter sets 13 digital inputs (2) 4 - 20 mA inputs (2) 0 - 10V input (3) Form C, 2 Form A, 2 NPN transistor, (1) 4 - 20 mA, & (1) 0 - 10V outputs RS-232 and RS-485 serial communications 100-line ladder logic processor for ultimate flexibility Configuration software included NEMA 4X enclosure Table 75. Features and Benefits Product Description The Fusion Integrated Machine Control has advanced features, including a five-preset high speed counter with prewarn, a totalizer with preset, a batch counter with preset and a ratemeter with high and low setpoints. Unique to the count control world, the Fusion has five output relays (rather than two), along with two transistors and two analog setpoint or follower outputs. Its ten available parameter sets of pre-loaded values are useful as recipes, for job-stacking or for a variety of application-specific purposes. The Fusion has a multi-line alphanumeric display which can be programmed to show text messages, logic-generated prompts, alarms and machine status. Up to eight screens can be shown or optionally locked out. Count and time presets can be made view-only or editable. Preset entry is achieved with simple 0-9 keys on the front panel rather than complicated scrolling methods. The Fusion's real time clock/calendar may be displayed and/or used to time and date stamp printouts. With its ladder logic, the Fusion is actually a 26 I/O controller, making it a complete control for many machines and processes, integrating the functions of external timers, pushbuttons, power supplies, indicating lights, control relays and other components in the same box. PG05400001E Feature Customer Benefit High speed count functions; including scaling, main counter, five presets, prewarn, totalizer, batch and rate "Canned" count functions offer flexibility and ease of setup in the desired units of measure. High speed counting independent of ladder scan time Precise and repeatable output response for high performance applications. Flexible display with selectable character sizes (large, medium, small), run screens and ladder triggered messages. Minimizes confusion and operator errors as information can be tailored to what they need and in their language. Maintenance/management data can be separated. Different character sizes allow optimization of information displayed. Machine status information can be displayed allowing operators to take action. Simple front panel layout and keypad. Four soft keys & six function keys can be used as inputs. Ease of use for operator. Numeric keypad allows for ease of preset and machine parameter entry. Function keys and soft keys allow easy and quick access to information and/or parameters needed by the operator and don't require using additional inputs. Eliminates cost associated with external pushbuttons and inputs. Parameter sets Allows for predefined recipes/jobs to be preloaded for the operator. Simplifies operator interaction and minimizes errors. Programmable relay logic Well understood programming method that allows flexibility in control functionality. Easy to tailor the control to various applications. 26 I/O (digital & analog) Provides application flexibility. Analog inputs allow monitoring key process parameters. Analog outputs allow interfacing to drives and other control products. Integrated solution Reduced overall control costs, installation and commissioning. More flexible and capable than traditional count/control solutions but less complex than many PLC solutions. Windows(R) and front panel programming Ease of programming and configuration control. RS-232 and RS-485 serial communication ports Allow for direct connection to PC for programming, connection to Modbus(R) networks, interface to serial printer. Robust type 4X package. DIN cutout and short depth 2.82 Inches (71.6 mm). Suited for wet applications. Same cutout as the President Series -- easing the migration. Short depth minimizes the cost and size of the machine panel or control enclosure. Input power: 85 - 265V AC 50/60 Hz or 10 - 30V DC models Greatly reduces models required for different control voltages. Output power: 12V DC @75 mA, 24V DC @100 mA Eliminates the need for an external power supply for encoders, analog transducers, etc. Depluggable screw terminals Allows for ease of wiring and removal of control. Terminals are different sizes to error-proof installation. Non-volatile memory and capacitor backed real time clock Don't have to worry about a battery failing down the road. Real time clock Allows for control functions to be performed on day/time and allows for date/time stamping on printouts. UL, cUL and CE Marked Ease of meeting machine agency requirements and robust EMC performance. For more information visit: www.eaton.com 79 Counters, Panel Meters, Tachometers and Timers Fusion (R) Integrated Machine Control 80 April 2007 Technical Data and Specifications Standards and Certifications UL and cUL Listed; CE Marked Technical Data and Specifications Environmental Operation: Indoor use to 2000m Temperature: 32 to 122F (0 to 50C) operating -4 to 158F (-20 to 70C) storage Humidity: 0 to 85% RH, non-condensing Vibration: 2.5 Gs, 30 - 200 Hz Shock: 30 Gs, 11 mS half sinewave EMC: EN61326:1997 All I/O lines except RS-485 <30m Front Panel: Type 4X indoor use only, when mounted with gasket provided Safety: UL and cUL Listed, CE Compliant Input Power AC Model: 85 - 265V AC, 47 - 63 Hz, 20 VA; Isolation 2300V AC DC Model: 10 - 30V DC, 15 VA Inputs Control: Number: 10 Impedance: 4.75k Ohms to +5V DC Thresholds: - High 3.5 - 30V DC - Low 0 - 1.0V DC Counter: Number: 3 (including reset) Impedance: 4.75k Ohms to +5V DC or 26.9k Ohms to ground Thresholds: - High 3.5 - 30V - Low 0 - 1.5V, or 200 mV p-p to 50V rms @ 26.9k Ohms (mag pickup) Response: - 140 Hz or 14 kHz for sinking, push-pull or mag pickup inputs - 60 Hz or 6 kHz for sourcing only inputs - All frequencies based on 50-50 duty cycle - 6 kHz maximum sustained count speed Analog: Number: 4 Type: 4 - 20 mA and two 0 - 10V DC Accuracy: 0.5% FS and 200 PPM/C Impedance: 100 Ohms (current input), 1.27M Ohms (voltage input) Overrange: 45 mA max. (current input), 20V max. (voltage input) Outputs Power (AC input model only): 24V DC 15%, 100 mA max., short circuit protected 12V DC 10%, 75 mA max., short circuit protected Relays: Number: 3 (Form C), 2 (Form A) Contacts: 5A, 250V AC, 30V DC Isolation: 2300V AC Transistors: Number: 2 Type: NPN Darlington Ratings: 150 mA max. ON current, 30V DC max. OFF voltage Analog: Number: 2, short circuit protected Type: 4 - 20 mA (<450 Ohms), 0 - 10V (>2500 Ohms) Accuracy: 0.5% FS and 200 PPM/C Common Mode Voltage Rating: 250V AC Isolation: 2300V AC For more information visit: www.eaton.com RS-232: Connector: DB-9S Polarity: DCE Baud Rate: 1200 - 19200 RS-485: Connector: 6 wire RJ-12 phonejack Baud Rate: 1200 - 19200 Data Retention Program Data: Type: Non-volatile Duration: 100 Years, no batteries Real Time Clock: Type: Capacitor Charge Time: 3 Minutes Retention: 1 - 5 Days Human Interface Display: Type: 128 x 64 pixel graphic LCD with LED backlight Character Size: - 0.12" (3 mm) high, 21 characters per line, 6 lines maximum - 0.24" (6 mm) high, 10 characters per line, 3 lines maximum - 0.35" (9 mm) high, 7 characters per line, 2 lines maximum Keys: Number: 18 Type: membrane switches with tactile feedback Real Time Clock Format: Seconds, minutes, hours, day and date PG05400001E Counters, Panel Meters, Tachometers and Timers Fusion (R) Integrated Machine Control April 2007 Product Selection Product Selection Table 76. Product Selection -- Fusion Integrated Machine Control Description Catalog Number Fusion Integrated Machine Control -- 10 - 30V DC Power Fusion Integrated Machine Control -- 85 - 265V AC Power Fusion Configuration Software 57550400 57551400 57590400 * Dimensions 5.33 (135.5) 01 L1 L2 xxxx 2 3 2 2 RUN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 15 16 17 Durant(R) P/N 57551 400 F1 F2 1 F4 F3 1 F5 1 F6 4 5 6 1 2 3 3.42 (86.9) 2.57 (65.3) 5 6.18 (157) 0.38 (9.7) 2.50 (63.5) 2.79 (70.8) 2.6770.028 (680.7) 5.4330.039 (1381) Figure 69. Fusion Integrated Machine Control -- Approximate Dimensions in Inches (mm) Note: Recommended Panel Cutout is 0.375 Inch (9.5 mm) max. panel thickness. Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 81 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 82 April 2007 DIN Rail Adapter Product Selection Contents Description Accessories DIN Rail Adapter . . . . . . . . . Vane Pickup Sensor . . . . . . C-Face Ring Tachometer . . . . . . . . . . . . Magnetic Pickup Sensor and Gear . . . . . . . . . . . . . . Rotary Contactor . . . . . . . . . Measuring Wheels . . . . . . . Page 82 83 83 Table 77. Product Selection -- DIN Rail Adapter Description Catalog Number DIN Rail Adapter for 1/32 DIN Panel Mount Devices A2448DINADAPT * Dimensions 83 84 84 3.98 (101.0) 1.98 (50.4) 1.77 (45.0) Encoders Cube Style . . . . . . . . . . . . . . 85 Heavy Duty . . . . . . . . . . . . . 87 Right Angle, Size 20 . . . . . . 89 1.77 (45.0) 2.95 (75.0) 1.0 (25.4) 3.29 (83.5) 2.76 (70.0) Cat. No. A2448DINADAPT Features Figure 70. DIN Rail Adapter -- Approximate Dimensions in Inches (mm) For panel-mounting all DIN size counters, timers and process indicators 0.94 x 1.89 Inch (24 x 48 mm) or 1.97 x 0.98 Inch (50 x 25 mm) Cut-out: 0.98 x 1.97 Inch (25 x 50 mm) For snap-on fitting to 35 mm top hat DIN rails Construction -- Mounting panel for counter: Chrome-plated sheet steel Top hat DIN rail adapter: Glass fiber reinforced polymide Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-1 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Accessories Vane Pickup Sensor Magnetic Pickup Sensor and Gear Cat. No. 39400400 Features 10 - 15V DC input power 35 mA current draw 10-foot (3m) shielded cable Environmentally sealed 3000 Hz maximum speed Cat. No. 47004400 and 28433400 Table 78. Product Selection -- Vane Pickup Sensor Description Catalog Number Vane Pickup Sensor with 10-foot (3m) Cable 39400400 * Features Magnetic Pickup 0.25" (6.4 mm) diameter Ideal for tachometer and rate control applications -40 to 298F (-40 to 148C) operating temperature Output is AC signal, amplitude proportional to speed of target 10-foot (3m) cable attached L-Mounting bracket included C-Face Ring Tachometer 30-Tooth Gear Accessory 1.6" (41 mm) diameter 0.275" (7 mm) bore diameter Mounting set screw included Cat. No. 47007056 Features Table 80. Product Selection -- Magnetic Pickup Sensor and Gear 5 - 16V DC input power NPN transistor output, 20 mA sinking capacity 60 pulses per resolution Zero speed pickup Variety of motor C-face sizes: 56, 184, 254, 256 39 to 225F (4 to 107C) operating temperature Description Catalog Number Magnetic Pickup 30-Tooth Gear for Magnetic Pickup 47004400 28433400 * Table 79. Product Selection -- C-Face Ring Tachometer Description Catalog Number * C-Face Sensor Motor Size 56C Motor Size 143TC, 145TC, 182C, 184C Motor Size 184TC, 213C, 215C, 254C 47007056 47007184 47007215 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-3 * Consult Sales Office for Pricing PG05400001E For more information visit: www.eaton.com 83 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders 84 April 2007 Accessories Rotary Contactor Measuring Wheels Cat. No. 39100400 Measuring Wheel Features Features No power required Reed switch output models for electronic counters Contact closure output Leaf switch output models for electromechanical counters 5/16" (7.9 mm) double shaft, 2400 rpm max. at 1:1 ratio 12" (304.8 mm) wire leads Catalog Number Rotary Contactor 12:1 Ratio Reed Switch Output 10:1 Ratio Reed Switch Output 1:1 Ratio Reed Switch Output 1:3 Ratio Reed Switch Output 1:3.28 Ratio Reed Switch Output 1:10 Ratio Reed Switch Output 1:10 Ratio Leaf Switch Output 1:1 Ratio Leaf Switch Output 1:3 Ratio Leaf Switch Output 39100400 39100401 Table 82. Product Selection -- Measuring Wheels Description Catalog Number * 1-Foot Circumference Measuring Wheel Table 81. Product Selection -- Rotary Contactor Description For use with shaft encoders and rotary contactors 12-inch (304.8 mm) meter circumference Urethane, rubber and knurled edges available * 5/16" Bore, Urethane Rim 3/8" Bore, Urethane Rim 5/16" Bore, Rubber Rim 3/8" Bore, Rubber Rim 5/16" Bore, Knurled Rim 3/8" Bore, Knurled Rim 20144300 20144303 20154300 20154301 20156300 20156301 41100400 41100401 41100402 41100403 40892400 40891400 40892401 Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-3 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Shaft Encoders -- Cube Style Technical Data and Specifications Cat. No. 38150600 Features 5 - 28V DC input power 80 mA current draw NPN transistor output, 250 mA sinking capacity Square wave output (50-50 duty cycle) Single channel and quadrature models Up to 600 pulses per revolution 3/8" (9.5 mm) double ended shaft ABEC 3 double sealed ball bearings Tapped holes for face or base mounting Military style connector PG05400001E Electrical Environmental Input (38150) -- Voltage: 9 to 16V DC Current: 60 mA max. @ 16V DC Ripple: 2% Input (38151) -- Voltage: 5 to 28V DC Current: 60 mA nom., 100 mA max. Ripple: ) 2% Output -- Type: Current sinking transistor with 1.5 k1 pull-up - Sinking current: 100 mA max. - Max. voltage @ 100 mA: 1.3V DC - Blocking voltage: 40V DC max. Polarity: Positive Wave Shape: Square wave Pulse Rate -- - 38150: 1 to 20,000 pulse per second - 38151: 1 to 10,000 pulse per second Rise Time: < 1 S Pulses per Rev.: 1 to 1270 Accuracy: Within 0.1 For more information visit: www.eaton.com Operating Temperature: 32 to 167F (0 to 75C) Vibration: 3 Gs at 5 to 1000 cps Shock: 20 Gs, 10 mS Mechanical Shaft Speed: 6000 RPM max. Shaft Rotation: CW or CCW Bearings: Sealed ball bearings Starting Torque: 0.1 oz-in Moment of Inertia: 0.0025 ounce inch-sec2 Radial Loading: 50 pounds operating Axial Loading: 10 pounds operating Shaft: 3/8" (9.5 mm) dia. Operating Life: Up to 100,000 hours, depending on speed Housing: Aluminum with black anodized finish. Sealed against dust, oil, vapor and moisture. Mounting: Bottom or front face Weight: 1 lb. (0.5 kg) max. Connector: MS-3102E-14S-6P Mating Connector: MS-3106A-14S-6S with 10' (3m) shielded cable and termination for electronic controls 85 86 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Shaft Encoders -- Cube Style Product Selection Table 83. Product Selection -- Cube Shaft Encoders Description Catalog Number * Single Channel 60 Pulses per Revolution 100 Pulses per Revolution 120 Pulses per Revolution 600 Pulses per Revolution 38150060 38150100 38150120 38150600 Quadrature 60 Pulses per Revolution 100 Pulses per Revolution 120 Pulses per Revolution 600 Pulses per Revolution 38151060 38151100 38151120 38151600 Dimensions 2.25 (57.2) 0.50 (12.7) 0.25 (6.4) 0.06 (1.6) 0.70 (17.8) 0.33 (8.3) 2.25 (57.2) 45 (4) 6.32 (160.5) Tapped Holes 0.25 (6.4) Deep on 2.00 (50.8) B.C. (Same Mtg. Holes on Opposite End and Bottom) 0.38 (9.5) 2.25 (57.2) (4) 6.32 (160.5) Tapped Holes 0.25 (6.4) Deep on 2.00 (50.8) B.C. Figure 71. Cube Shaft Encoders -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Shaft Encoders -- Heavy Duty Technical Data and Specifications Cat. No. 48370060 Features 5 - 28V DC input power 80 mA current draw NPN transistor output, 250 mA sinking capacity Square wave output Single channel and quadrature models 3/8" (9.5 mm) single ended shaft ABEC 3 double sealed ball bearings Tapped holes for face or base mounting Military style connector PG05400001E Electrical Mechanical Input -- Voltage: 5 to 28V DC Current: 60 mA nom., 100 mA max. Ripple: -2% Output -- Type: Current sinking transistor with 1.5 k1 pull-up - Sinking current: 100 mA max. - Max. voltage @ 100 mA: 1.3V DC - Blocking voltage: 40V DC max. Polarity: Positive Wave Shape: Square wave (50-50 duty) Pulse Rate: 0 to 20,000 pulse per second Rise Time: < 1 S Pulses per Rev.: 1 to 1270 Accuracy: Within 0.1 or 6 arc minutes Environmental Operating Temperature: 32 to 167F (0 to 75C) Vibration: 3 Gs at 58 to 500 cps Shock: 50 Gs, 11 mS duration For more information visit: www.eaton.com Shaft Speed: 6000 RPM max. Shaft Rotation: CW or CCW Bearings: Sealed ball bearings Starting Torque: 1.0 oz-in Radial Loading: 50 pounds operating Axial Loading: 35 pounds operating Shaft: 3/8" (9.5 mm) dia. Housing: Aluminum with black painted finish. Sealed against dust, oil, vapor and moisture. Mounting: Provisions for bottom or front face Weight: 3.25 lbs. (1.47 kg) max. Connector: MS-3102E-14S-6P Mating Connector -- MS-3106A-14S-6S with 10' (3m) shielded cable and termination for electronic controls (Part No. 29665-300) Connector, clamp and bushing only (Part No. 29729-300) 87 88 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Shaft Encoders -- Heavy Duty Product Selection Table 84. Product Selection -- Heavy Duty Encoder Description Catalog Number * Single Channel 60 Pulses per Revolution 100 Pulses per Revolution 120 Pulses per Revolution 600 Pulses per Revolution 48370060 48370100 48370120 48370600 Quadrature 60 Pulses per Revolution 100 Pulses per Revolution 100 Pulses per Revolution 600 Pulses per Revolution 48371060 48371100 48371120 48371600 Dimensions 3.00 (76.2) 1.50 (38.1) 0.70 (17.8) 0.81 (20.6) 3.00 (76.2) 0.06 (1.6) 1.50 (38.1) 1.13 (28.6) 1.18 (30.0) 1.50 (38.1) 3.00 (76.2) 1.50 (38.1) 45 Mounting Holes (Typical) 1/4-20, 0.55 (14.0) Deep on 2.00 (50.8) B.C. 6.00 (152.4) Dia. 0.38 (9.5) Shaft with Flat 2.00 (50.8) Bolt Hole Circle Figure 72. Heavy Duty Encoder -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Shaft Encoders -- Right Angle, Size 20 Technical Data and Specifications Electrical Environmental Input Voltage: 5 to 28V DC (4.75 min., 28.0 max.) Current: 100 mA max. with no output load Ripple: -2% peak to peak at 5V DC Output Type: Quadrature current sinking transistors with 2.2 k1 pull-up Sinking current: 100 mA max. Max. voltage @ 100 mA: 1.3V DC Blocking voltage: 40V DC max. Polarity: Positive Wave Shape: Square wave (50-50 duty cycle) Pulse Rate: 0 to 100,000 pulses per second Noise Immunity: Tested to BS EN6100-4-2; IEC801-3; BS EN61000-4-4; DDENV 50141; DDENV 50204; BS EN55022 (with European compliance option) Symmetry: 180 electrical degrees 18 Quadrature Phasing: 90 electrical degrees 36 Minimum Edge Separation: 54 electrical degrees Rise Time: < 1 S Pulses per Rev.: 1 to 1270 Accuracy: Within 0.1 Cat. No. 38159100 Features 5 - 28V DC input power 100 mA current draw NPN transistor output, 100 mA sinking capacity Quadrature output, 2 square waves Up to 1800 pulses per revolution Flange mounting 3/8" (9.5 mm) shaft diameter Double shielded ball bearings Military style connector PG05400001E For more information visit: www.eaton.com Operating Temperature: 32 to 158F (0 to 70C) Vibration: 20 Gs at 50 to 500 cps Shock: 75 Gs, 11 mS Mechanical Shaft Speed: 8000 RPM max. Shaft Rotation: CW or CCW Bearings: Double shielded ball bearings Starting Torque: 1.0 oz-in typical Moment of Inertia: 5.2 x 104 ounce inch-sec2 Radial & Axial Loading: (80 lbs max.) 20 - 40 lbs for bearing life of 1.5x109 revolutions Maximum Acceleration: 1x105 Radians/second2 Shaft: 0.375" (9.5 mm) dia. Housing: Black non-corrosive finish. Sealed against dust, oil, vapor and moisture. Mounting: Flange mount Weight: 11 oz (312 g) Connector: MS-3102E-14S-6P Mating Connector -- MS-3106A-14S-6S with 10' (3m) shielded cable and termination for electronic controls (Part No. 29665-300) Connector, clamp and bushing only (Part No. 29729-300) 89 90 Counters, Panel Meters, Tachometers and Timers Accessories and Encoders April 2007 Shaft Encoders -- Right Angle, Size 20 Product Selection Table 85. Product Selection -- Right-Angle Shaft Encoder, Size 20 Description Catalog Number 100 Pulses per Revolution 120 Pulses per Revolution 600 Pulses per Revolution 38159100 38159120 38159600 1000 Pulses per Revolution 1800 Pulses per Revolution 381591000 381591800 * Dimensions 6-32 UNC 0.25 (6.4) Deep 4 x 90 Dia. 2.0 (50.8) B.C. Side Mount MS Style Connector Shaft Size 3/8" 0.3745 (9.512) 0.87 (22.1) 0.75 (19.1) 0.80 (20.3) 0.63 (15.9) 1.18 (30) 2.06 1.75 (52.3) (44.5) 1.41 (35.9) 2.06 (52.3) 0.05 (1.3) Dia. 0.16 (4.0) Through 4 x 90 Dia. 2.48 (62.9) B.C. 2.0 (50.8) 0.05 (1.3) 0.30 (7.6) 0.60 (15.2) 2.0 (50.8) Figure 73. Right-Angle Shaft Encoder -- Approximate Dimensions in Inches (mm) Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . . CC-4 * Consult Sales Office for Pricing For more information visit: www.eaton.com PG05400001E Eaton's electrical business is a global leader in electrical control, power distribution, uninterruptible power supply and industrial automation products and services. Eaton's global electrical brands, including Cutler-Hammer , Powerware , Holec and MEM , provide customer-driven PowerChain Management solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide. (R) (R) (R) (R) TM Eaton Corporation is a diversified industrial manufacturer with 2006 sales of $12.4 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 60,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com. Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN CARE (877-386-2273) Eaton.com (c) 2007 Eaton Corporation All Rights Reserved Printed in USA Form No. PG05400001E April 2007 1