AJM90 Series AC-DC Power Supplies 90 Watts * Energy Efficiency Level VI * Medical and ITE Safety Approvals * 4th Edition Medical EMC * Class I and Class II Versions * <0.21 W Standby Power * 0 C to 60 C Operation * Low Earth Leakage Current * 3 Year Warranty Dimensions: AJM90: 5.51 x 2.8 x 0.87" (140.0 x 71.0 x 22.0 mm) Models & Ratings Output Power Output Voltage Output Current 12.0 V 18.0 V 19.0 V 24.0 V 90 W 7.50 A 5.00 A 4.74 A 3.75 A Total Regulation Efficiency(1) 5% 88% 89% 90% 90% Model Number(2) AJM90PS12 AJM90PS18 AJM90PS19 AJM90PS24 Notes 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 2. For class II versions, add suffix 'C2' to the end of the part number e.g. AJM90PS24C2. Class II versions do not have ITE approvals. Mechanical Details 5.5 (140.0) 59.0 (1500.0) Pin 4(+) Pin 2(+) Pin 3(-) 1.6 (42.4) 0.26 (6.5) 0.39 Pin 1(-) (10.0) With Lock 1.18 (30.0) 1.5 (39.0) 2.8 (71.0) 0.94 (24.0) 0.59 (15.0) Wire no. UL11352 Gauge: 18 AWG Colour: Black 0.29 (7.4) IEC320-C6 Inlet 0.29 (7.4) Optional C2 Version IEC320-C8 Inlet 0.86 (22.0) 4.72 (120.0) 3.15 (80.0) Pin Connector Pin 1 2 3 4 Shell Function Return Output + Return Output + Return Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Output connector: Locking Power Mini DIN, mates with Kycon KPJX-4S or equivalent. 1 3. Weight: 0.77 lbs (350 g) approx. 4. For European mains lead order part EU-MAINS-5 or EU-MAINS-8 for C2 versions. 5. For UK mains lead order part UK-MAINS-5 or UK-MAINS-8 for C2 versions. 6. For US mains lead order part US-MAINS-5 or US-MAINS-8 for C2 versions. www.xppower.com AJM90 Series AC-DC Power Supplies Input Units Notes & Conditions 264 VAC Derate output power below 90 VAC to 90% at 85 VAC and 85% at 80 VAC 63 60/100 Hz A A 250 0.21 A W Max. 48 2 Units VDC % 3 50 Full load and 115 VAC 0.5 5 s ms ms % % Transient Response 4 % Maximum deviation, recovering to less than 1% within 500 s for 25% step load Ripple and Noise 1 % pk-pk 150 mV pk-pk for 12 V model, measured with 20 MHz bandwidth and 10 F electrolytic in parallel with 0.1 F ceramic capacitor. 5 175 150 % % % 100 %/C A 264 VAC, 60 Hz Maximum +60 Units C Notes & Conditions Derate from 100% load at 40 C to 50% load at 60 C Characteristic Minimum Input Voltage 80 Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current No Load Input Power Input Protection 47 Typical Maximum 1.5/0.6 0.9 220 Measured at 115/230 VAC 115/230 VAC, cold start at 25 C EN61000-3-2 Class A 264 VAC, 60 Hz T3.15A/250 VAC internal fuse in both line Output Characteristic Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Total Regulation Min. 12 Typ. 10 Overshoot Overload Protection Overvoltage Protection Short Circuit Protection Thermal Protection Temperature Coefficient Patient Leakage Current 115 112 Trip and restart (hiccup), auto resetting Measured internally, recycle AC to reset 0.04 Notes & Conditions See Models and Ratings table At 50% load No minimum load required At turn on / turn off Recycle mains to reset Environmental Characteristic Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Vibration Minimum 0 Natural convection 5 -40 Typical 90 %RH +85 C 5000 m IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes Non-condensing 100% Output Power (%) Derating Curve 80% 60% 40% 20% 0 20 40 Ambient Temperature (C) www.xppower.com 60 2 AJM90 Series AC-DC Power Supplies General Characteristic Minimum Typical Efficiency Maximum % VAC 2 x MOPP 1500 VAC 1 x MOPP (Class I versions only) 1500 VAC 1 x MOPP (Class I versions only) 105/100 kHz PFC/Main Converter 4.55 W/in3 Power Density Mean Time Between Failure Weight See Models and Ratings table and curves. 4000 Isolation: Input to Output Input to Ground Output to Ground Switching Frequency Notes & Conditions Units 90 >100 kHrs 0.77 (350) lb (g) MIL-HDBK-217F at 25 C GB Efficiency Curves AJM90PS12 100% 90% 80% Efficiency 70% 60% 50% 115Vac input 40% 230Vac input 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) AJM90PS24 100% 90% 80% Efficiency 70% 60% 50% 115Vac input 40% 230Vac input 30% 20% 10% 0% 10 20 30 40 50 60 70 80 90 100 Load (%) EMC: Emissions Phenomenon Emissions Harmonic Current Voltage Flicker Standard EN55011 EN61000-3-2 EN61000-3-3 Test Level Level B Class A www.xppower.com Notes & Conditions Conducted & Radiated 3 AJM90 Series AC-DC Power Supplies EMC: Immunity Test Level Criteria ESD Phenomenon EN61000-4-2 Standard 15 kV Air, 8 kV contact A Radiated EN61000-4-3 10 V/m A EFT/Burst Surge Conducted Magnetic Fields EN61000-4-4 EN61000-4-5 EN61000-4-6 EN61000-4-8 3 Installation Class 3 6V 30 A/m Dip: 30% 500 ms Dip: 60% 200 ms Int: 100% 5000 ms Int: 100% 10 ms Dip: 30% 500 ms Dip: 60% 100 ms Int: 100% 5000 ms Int: 100% 10 ms A A A A A/B A/B B A A/B A/B B A EN61000-4-11 Dips and Interruptions EN60601-1-2 Notes & Conditions Class I is 3 V/m, Class II is 10 V/m 80-2700 MHz. IEC60601-1-2 Ed.4 at other frequencies High Line/Low Line High Line/Low Line High Line/Low Line High Line/Low Line Safety Approvals Safety Agency Safety Standard Notes & Conditions UL ANSI/AAMI ES 60601-1 CSA CSA C22.2 No. 60601 TUV EN60601-1 CB IEC60601-1 UL UL60950-1 TUV EN60950-1 CB IEC60950-1 AU/NZ AU/NZ 60950.1 Medical ITE, on class I version only Mechanical Details 5.5 (140.0) 59.0 (1500.0) 1.6 (42.4) Pin 4(+) Pin 2(+) Pin 3(-) 0.26 (6.5) 0.39 Pin 1(-) (10.0) With Lock 1.18 (30.0) 1.5 (39.0) 2.8 (71.0) 0.94 (24.0) 0.59 (15.0) Wire no. UL11352 Gauge: 18 AWG Colour: Black 0.29 (7.4) IEC320-C6 Inlet 0.29 (7.4) Optional C2 Version IEC320-C8 Inlet 0.86 (22.0) 4.72 (120.0) 3.15 (80.0) Pin Connector Pin 1 2 3 4 Shell Function Return Output + Return Output + Return Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJX-4S or equivalent. 3. Weight: 0.77 lbs (350 g) approx. 4. For European mains lead order part EU-MAINS-5 or EU-MAINS-8 for C2 versions. 5. For UK mains lead order part UK-MAINS-5 or UK-MAINS-8 for C2 versions. 6. For US mains lead order part US-MAINS-5 or US-MAINS-8 for C2 versions. www.xppower.com 14 Feb 19