Panel Mount Datasheet GN3 Series * Current ratings of 25 and 50 Amps * Output voltage rating: 48-600 VAC * Direct bond copper substrate * LED input status indicator * IP20 "touch-safe" cover * Transient protection built-in * UL508 endurance rating for enhanced reliability * UL/CSA/TUV Approved, CE Compliant to EN60950-1 PRODUCT SELECTION Control Voltage 4-32 VDC 18-36 VAC 90-140 VAC 180-260 VAC 25A 50A GN325DLZ GN325ELZ GN325BLZ GN325ALZ GN350DLZ GN350ELZ GN350BLZ GN350ALZ AVAILABLE OPTIONS Control Voltage A: 180-260 VAC B: 90-140 VAC D: 4-32 VDC E: 18-36 VAC Series GN3 25 A Rated Load Current 25: 25 Amps 50: 50 Amps L Switching Type R: Instantaneous Turn-on Z: Zero voltage Turn-on Z Snubber Option L: No Snubber (48-600 VAC) S: Snubber Included (48-530 VAC) Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1) Description Operating Voltage (47-400Hz) [Vrms ] (2) Transient Overvoltage [Vpk, t=1 min.] (3) Static off-state dv/dt (V/sec, Ta=25C) (4) Maximum Load Current [Arms] (5) Minimum Load Current [mArms] Maximum Off-State Leakage Current [mArms] (6)(7) 1 Cycle surge current (50Hz) 1 Cycle surge current (60Hz) 1 Second surge current (Apk. Ta=25C) 50/60 Hz Forward Voltage Drop (Vpk @ Imax, Ta=25C) I2T (50Hz, 1/2 cycle) I2T (60Hz, 1/2 cycle) Thermal Resistance Junction to baseplate (Rjb) [C/W] HP Ratings at 120V / FLC [Arms] HP Ratings at 240V / FLC [Arms] HP Ratings at 480V / FLC [Arms] HP Ratings at 600V / FLC [Arms] Min/Max wire size Screw Torque Range [in-lb/Nm] 25A 50A 48-600 1200 500 25 100 0.06 275 300 85 1.35 380 370 0.24 0.75 / 6.4 1 / 4.2 3 / 4.8 5 / 6.1 16/8 AWG 18-20 / 2.03-2.26 48-600 1200 500 50 100 0.06 710 750 150 1.35 2520 2320 0.12 1.5 / 12 3 / 9.6 7.5 / 11 10 / 11 16/8 AWG 18-20 / 2.03-2.26 FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description Control Voltage Range Minimum Turn-On Voltage Must Turn-Off Voltage Maximum input current Minimum input current (for on-state) Input Resistance Turn-On Time [msec] (8) Turn-Off Time [msec] Min/Max wire size Screw Torque Range [in-lb/Nm] GN3xxDx GN3xxEx GN3xxBx GN3xxAx 4.0-32 VDC 4.0 VDC 1.0 VDC 39 mA 24 mA 18-36 Vrms 18 Vrms 2 Vrms 20 mArms 15 mArms 90-140 Vrms 90 Vrms 10 Vrms 16 mArms 7 mArms 180-260 Vrms 180 Vrms 10 Vrms 16 mArms 7 mArms 1/2 Cycle 1/2 Cycle 20 30 20 30 20 30 Current Regulated 24/14 AWG 8-10 / 0.9-1.13 GENERAL SPECIFICATIONS Description Parameters Ambient Operating Temperature Range (9) Ambient Storage Temperature Range -40C to 80C -40C to 125C 4000 Vrms 2500 Vrms 8 pF UL 94V0 (self extinguishing) Green LED 0.79 oz (360 g) Input to output isolation Input/Output to ground isolation Input to output capacitance Housing Material Input Status Indicator Weight (typical) GENERAL NOTES 1) All parameters at 25C unless otherwise specified. 2) For part numbers with snubber Hz range is 47-63 and line voltage is 48-530VAC 3) Output will self trigger between 900-1200Vpk. 4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 5) When mounted to the proper size heat sink (see derating curves) 6) For part numbers with snubber maximum leakage current is 5mA. 7) Measured between 1/L1 and 2/T1 or 3/L2 and 4/T2 or 5/L3 and 6/T3 8) For DC control Instantaneous turn-on is 100 sec while for AC control is 20 msec 9) Operating temperature range for 180-280VAC is -20 to +60C MECHANICAL SPECIFICATIONS Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] 4.0 [101.3] 3.6 [92.0] 5/L3 3/L2 1/L1 1.87 [47.6] 3.2 [79.7] 0.2 [5.1] 6/T3 4/T2 2/T1 0.8 [19.3] 1.5 [38.6] 1.45 [36.83] 4.09 [103.9] Do not forget to visit us at: www.crydom.com Copyright (c) 2017Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet EQUIVALENT CIRCUIT BLOCK DIAGRAM LOAD L3 AC + A1 Load can be wired in either position - A2 T3 LOAD AC L2 LOAD AC Load can be wired in either position T2 LOAD AC L1 LOAD AC Load can be wired in either position LOAD T1 AC * Snubber not included in all models THERMAL DERATE INFORMATION GN325xxx GN350xxx 1.0 C/W 0.7 C/W 0.25 C/W 25 50 20 40 Load Current (Amps) Load Current (Amps) 0.5 C/W 15 10 5 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) 0.7 C/W 0.5 C/W 30 20 10 0 0 10 20 30 40 50 60 Ambient Temperature (C) Heat Sink part numbers corresponding to C/W ratings above: 1.0 C/W = HS103, 0.5 C/W = HS053. All others consult factory Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. 1.0 C/W 70 80 Panel Mount Datasheet AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: IEC 62314 IEC 60068-2-6 35mm / 10-55Hz IEC 60068-2-27 15G / 11ms IEC 1000-4-2: Electrostatic Discharge - Level 3 IEC 1000-4-3: Radiated Electromagnetic Noise - Level 3 IEC 1000-4-4: Electrically Fast Transients - Level 3 IEC 1000-4-5: Electrical Surges - Level 3 IEC 1000-4-6: Conducted Electromagnetic Noise - Level 3 E79183 LR38595 Rev. 102017 ECN 20340 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSIONE. * Spenga tutta l'alimentazione che fornisce questa apparecchiatura prima di lavorare a questa apparecchiatura * * Verificare tutti i collegamenti e sostituire tutte le coperture prima dell'accensione L'omissione di queste istruzioni provochera la morte o lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. * * * Panel Mount Datasheet ANNEX - ENVIRONMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)