TM OxiCap - NOJ Niobium Oxide Capacitor A Kyocera Group Company PRODUCT SPECIFICATIONS : Nominal Capacitance @ 120Hz 22F Capacitance Tolerance (*) M = 20% Rated Voltage DC (VR) o < 85 C Category Voltage DC (VC) < 105 C 7V Surge Voltage (VS) o < 85 C 13V 8V o o < 105 C 10V Temperature Range -55oC to +105oC Direct Leakage Current max. @ VR 4.4A Disipation Factor max. @ 120Hz 6% ESR max. @ 100kHz 1.8 Typical weight (B case) 56mg Pb HALOGEN-FREE COMPOUNDS NON-BURN Moisture sensitivity level: meets MSL 1 LE AD -F R E E NON-SMOKE ENVIRONMENTAL FRIENDLY LEAD-FREE COMPATIBLE Reflow specification: meets J-STD-020C standard COMPONENT COMPONENT Meets requirements of AECQ-200 100% surge current tested All technical data relates to an ambient temperature of +25 C, Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V. DCL is measured at rated voltage after 5 minutes AVX reserves the rights to supply higher voltage rating in the same case size, to the same reliability standards RMS value of Ripple Current (mA) @100kHz 25C 238 85C 214 RMS value of Ripple Voltage (mV) @100kHz 125C 95 25C 428 85C 386 125C 171 HOW TO ORDER: NOJ B 226 M 010 #WJ Type Case code Capacitance Value Cap. Tolerance Rated DC Packaging DRAWING AND DIMENSIONS: Capacitance Value in pF OxiCapTM LOGO 226 = 22F Rated Voltage A = 10V 226 A T 1 5 BB Polarity Band Niobium oxide capacitors are manufactured and sold under patent license from Cabot Corporation, Boyertown, Pennsylvania U.S.A. TM OxiCap - NOJ Niobium Oxide Capacitor A Kyocera Group Company CASE DIMENSIONS: millimetres Case EIA AVX L 0.2 W +0.2 - 0.1 H +0.2 - 0.1 A +0.3 - 0.2 S min. W1 0.2 3528-21 B 3.5 2.8 1.9 0.8 1.4 2.2 PACKAGING INFORMATION: Reel Size (#) R = 7" Reel S = 13" Reel A = 7" Reel Gold Plated Termination B = 13" Reel Gold Plated Termination Quantity Tape Width 2000 8 mm 8000 8 mm 2000 8 mm 8000 8 mm A Kyocera Group Company AVX Myrtle Beach, SC AVX Limited, England AVX/Kyocera, Singapore Corporate Offices European Headquarters Asian-Pacific Tel: 843-448-9411 Tel: +44 (0) 1252 770000 Tel: (65) 258-2833 Fax: 843-448-1943 Fax: +44 (0) 1252 770001 Fax: (65) 350-4880 AVX Northwest, WA AVX/Kyocera, Hong Kong AVX S.A., France Tel: 360-669-8746 Tel: +33 (1) 69.18.46.00 Tel: (60) 4-228-1190 Fax: 360-699-8751 Fax: +33 (1) 69.28.73.87 Fax: (60) 4-228-1196 AVX North Central, IN AVX GmbH, Germany AVX/Kyocera, Korea Tel: 317-848-8114 Tel: +49 (0) 8131 9004-0 Tel: (82) 2-785-6504 Fax: 317-844-9314 Fax: +49 (0) 8131 9004-44 Fax: (82) 2-784-5411 AVX Northeast, MA AVX/Kyocera, China AVX srl, Italy Tel: 508-485-8114 Tel: +390 (0)2 614571 Tel: (86) 21-6249-0314-16 Fax: 508-485-8471 Fax: +390 (0)2 614 2576 Fax: (86) 21-6249-0313 AVX Mid-Pacific, CA AVX Czech Republic s.r.o. AVX/Kyocera, Malaysia Tel: 408-436-5400 Tel: +420 465 358 111 Tel: (60) 4-228-1190 Fax: 408-437-1500 Fax: +420 465 323 010 Fax: (60) 4-228-1196 AVX Southwest, AZ AVX GmbH, Gemany - Elco Kyocera, Japan - AVX Tel: 602-539-1496 Tel: +49 (0) 2741 2990 Tel: (81) 75-604-3426 Fax: 602-539-1501 Fax: +49 (0) 2741 299299 Fax: (81) 75-604-3425 AVX South Central, TX Tel: 972-669-1223 Fax: 972-669-2090 www.avx.com Technical contact: techsale-niobium@avx.cz Tantalum samples: tantalum-samples@avx.cz TM For latest update on OxiCap see: www.avx.com/tabanner.pdf Version 6/05 NOTICE: Specifications are subject to change without notice. Contact your nearest AVX Sales Office for the latest specifications. All statements, information and data given herein are believed to be accurate and reliable, but are presented without guarantee, warranty, or responsibility of any kind, expressed or implied. Statements or suggestions concerning possible use of our product are made without responsibility or warranty that any such use is free of patent infringement and are not recommendations to infringe any patent. The user should not assume that all safety measures are indicated or that other measures are indicated or that measures may not be required. Specifications are typical and may not apply to all applications.