Total Counter/Time Counter (DIN 72 x 36) H7HP Compact Total Counters and Time Counters with Easy-to-read Displays and IP66G/ NEMA4 Water and Oil Resistance * Large, easy-to-read displays: 15-mm-high characters for 6-digit models; 12-mm-high characters for 8-digit models. * High-visibility, negative transmissive LCD display with built-in red LED backlight at low power consumption. * Compact (66 mm) body. * Switch 6-digit models between total counter and time counter operation. Model Number Structure Model Number Legend H7HP-@@@@ 1 2 3 4 1. Classification A: Total counter/time counter C: Total counter 2. Digits None: 6 digits 8: 8 digits 3. Supply Voltage None: 100 to 240 VAC D: 12 to 24 VDC 4. Case Color None: Light gray (Munsell 5Y7/1) B: Black Ordering Information List of Models Supply voltage 6-digit total counter/time counter Light gray Black 8-digit total counter Light gray Black 100 to 240 VAC H7HP-A H7HP-AB H7HP-C8 H7HP-C8B 12 to 24 VDC H7HP-AD H7HP-ADB H7HP-C8D H7HP-C8DB http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 1 H7HP Specifications Ratings Item 6-digit total counter/time counter H7HP-A 8-digit total counter H7HP-AD H7HP-C8 H7HP-C8D Rated supply voltage 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (see note 1) External power supply 50 mA at 12 VDC Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 to 240 VAC: 6.5 VA max. 12 to 24 VDC: 0.6 W max. Dimensions 72 x 36 x 66 mm (W x H x D) Mounting method Flush mounting External connections Screw terminals Degree of protection Panel surface: IEC IP66 (JEM standard IP66G) and NEMA Type 4 (indoors) Display 7-segment, negative transmissive LCD (with red backlight) Digits 6 digits (15-mm-high characters) 8 digits (12-mm-high characters) Function Total counter/time counter (selected via DIP switch) Total counter Input mode Up/down (individual) (total counter), or accumulative (time counter) Up/down (individual) Max. counting speeds 30 Hz or 5 kHz (selected via DIP switch) Counting range -99999 to 999999 Time specification 0.1 to 99999.9 h/1 s to 99 h 59 min 59 s --- Timing accuracy 100 ppm (-10C to 55C) --- Memory backup EEP-ROM: 200,000 operations min. Input Input signals Count 1/start, count 2/gate, reset, and key protection (see note 2) Input method No-voltage input (NPN transistor input) or voltage input (PNP transistor input) (selected via DIP switch) Count, start, gate, reset No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage: 2 VDC max. Open (OFF) impedance: 100 k min. Voltage input (PNP transistor input) Short-circuit (ON) impedance: 1 k max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 k max. Key protection No-voltage input (NPN transistor input) Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage: 0.5 VDC max. Open (OFF) impedance: 100 k min. Reset Time counter: 20 ms; total counter: 20 ms or 1 ms (automatically switched according to counting speed) Start Time counter: 20 ms Key protection Approx. 1 s Input response speed Reset system --- 50 mA at 12 VDC --- -9999999 to 99999999 Approx. 1 s External and manual resets Note: 1. Contains 20% ripple (p-p) max. 2. Only a non-voltage input (NPN transistor) is possible for the key protection input. The key protection input will be a non-voltage input even if the NPN/PNP input mode is set to PNP. Key protection is used to prohibit operating the Reset Key. The reset input terminals will still be functional. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 2 H7HP Characteristics Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (AC model) 1,000 VAC, 50/60 Hz for 1 min between current-carrying terminal and exposed non-current-carrying metal parts (DC model) 2,000 VAC, 50/60 Hz for 1 min between power terminals and control input terminals (AC model) Impulse withstand voltage 3 kV (between power terminals) (1 kV for 12-to-24-VDC models) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) (1.5 kV for 12-to-24-VDC models) Noise immunity 1.5 kV (between AC power terminals), 480 V (between DC power terminals), 480 V (between input terminals); square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Static immunity Display: Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction: 10 to 55 Hz with 0.5-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Shock resistance Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions Ambient temperature Operating: -10C to 55C (with no icing) Storage: -25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% EMC (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: E61326 EN55011 Group 1 class A EN55011 Group 1 class A EN61326 EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3); 2 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2); 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) Approved standards UL508, CSA22.2 No.14, conforms to EN61010-1, VDE0106/P100 Case color Rear section: Gray smoke; Front section: 5Y7/1 (light gray) or N1.5 (black) Weight Approx. 115 g Malfunction: Destruction: DIP switch: Malfunction: Destruction: http://www.ia.omron.com/ 8 kV 15 kV 4 kV 8 kV (c)Copyright OMRON Corporation 2007 All Rights Reserved. 3 H7HP Connections Terminal Arrangement Note: 1. Incremented for count 1 (CP1) inputs; decremented for count 2 (CP2) inputs. 2. Non-contact input is also available. AC Models H7HP-A H7HP-C8 External power supply 12 VDC 50 mA max. 100 to 240 VAC Power supply Power supply 5 Unused Unused Unused 6 7 8 9 1 2 3 4 Key protection input 0V 12 VDC Power supply 10 11 5 Power supply Unused Unused Unused 6 7 8 9 1 2 3 4 Key protection input Count 1 Count 2 input or input or start input gate input Reset input External power supply 12 VDC 50 mA max. 100 to 240 VAC 0V 12 VDC 10 11 Count 1 Count 2 input input Reset input NPN mode NPN mode PNP mode PNP mode DC Models H7HP-AD H7HP-C8D 12 to 24 VDC 12 to 24 VDC Power supply 0V 5 6 7 8 9 1 2 3 4 Key protection input 0V Unused Unused Unused Unused Unused Reset input 10 5 11 Power supply 6 7 8 9 1 2 3 4 Key protection input Count 1 Count 2 input or input or start input gate input Unused Unused Unused Unused Unused Reset input 10 11 Count 1 Count 2 input input NPN mode NPN mode PNP mode PNP mode Operation DIP Switch Settings H7HP-C8/-C8D Switches 1 to 4 are all set to OFF before shipping. Pin no. Item OFF ON 1 Function Total counter Time counter 2 Counting speed (note) 30 Hz 5 kHz Time range (note) 99999.9 h 99 h 59 min 59 s 3 Input mode (note) NPN PNP 4 Unused --- --- http://www.ia.omron.com/ OFF ON Unused --- --- 2 Counting speed (note) 30 Hz 5 kHz 3 Input mode (note) NPN PNP 4 Unused --- H7HP-A/-AD Pin no. Item 1 --- Note: When the setting has been changed, turned power off and on to continue. The display will show "0" when the power is turned back on. (c)Copyright OMRON Corporation 2007 All Rights Reserved. 4 H7HP Operating Modes Total Counters Reset input CP1 CP2 999999 (see note) Display 0 -99999 (see note) display Note: Display values are shown for a 6-digit model. The count value will return to "0" when "999999" is exceeded. Time Counters Reset input Gate input Start input 99999.9h (see note 1) Display 0.0 h Note: 1. Display values are shown for full scale set to 99999.9 h. The count value will return to "0" when "99999.9" is exceeded. 2. Gate input is available only when H7HP-A settings are made. Nomenclature 2 (The figure shows the DIP switch label stuck to the rear of the case.) 1 3 1. Reset Key Resets the count value, but will not operate while the keys are protected. 2. Key Protection Indicator Lit while the keys are protected (Reset Key is disabled.). 3. DIP Switch Use to change a setting. Refer to DIP Switch Settings for details. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 5 H7HP Dimensions Note: All units are in millimeters unless otherwise indicated. H7HP-A H7HP-C8 M3.5 terminal screw Terminal cover (provided) Panel Cutouts Panel cutouts are as shown below (according to DIN43700). Note: 1. The mounting panel thickness should be 1 to 6 mm. 2. Water resistance will be lost if Counters are mounted side-by-side. With Flush Mounting Bracket Y92S-33 rubber packing (provided) http://www.ia.omron.com/ Panel Y92F-33 flush mounting adaptor (provided) (c)Copyright OMRON Corporation 2007 All Rights Reserved. 6 H7HP Connections (Common) Input Connections Note: The undermentioned is common for all H7GP/H7HP models. No-voltage Input (NPN Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Open Collector Output Voltage Output H7GP/H7HP Sensor 12 VDC (12 to 24 VDC) Sensor Reset input Count 1 input Count 2 input Start input Gate input 12 VDC (12 to 24 VDC) Reset input Count 1 input Count 2 input Start input Gate input 0V 12 VDC (12 to 24 VDC) Reset, Count 1, Count 2, Start, and Gate Inputs Specification Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage: 2 VDC max. Current flow for 0- short-circuit: Approx. 2 mA Open (OFF) impedance: 100 k min. Note: Two-wired sensors cannot be used. 0V Key Protection Input Open Collector Output Voltage Output H7GP/H7HP 12 VDC (12 to 24 VDC) Sensor Sensor Key protection input 0V 12 VDC (12 to 24 VDC) Key protection input Key Protection Inputs Specification Short-circuit (ON) impedance: 1 k max. Short-circuit (ON) residual voltage: 0.5 VDC max. Current flow for 0- short-circuit: Approx. 0.5 mA Open (OFF) impedance: 100 k min. Note: Two-wired sensors cannot be used. 0V Voltage Input (PNP Input Mode) Reset, Count 1, Count 2, Start, and Gate Inputs Sensor 12 VDC (12 to 24 VDC) Reset input Count 1 input Count 2 input Start input Gate input Reset, Count 1, Count 2, Start, and Gate Inputs Specification Short-circuit (ON) impedance: 1 k max. ON voltage: 9 to 24 VDC OFF voltage: 5 VDC max. Open (OFF) impedance: 100 k min. Note: Two-wired sensors cannot be used. 0V http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 7 H7HP Safety Precautions (Common) Note: The undermentioned is common for all H7GP/H7HP models. Flush Mounting !CAUTION This may occasionally cause electric shock, fire, or malfunction. Never disassemble, repair, or modify the H7GP/H7HP. This may occasionally cause electric shock, fire, or malfunction. Do not allow metal fragments or lead wire scraps to fall inside the H7GP/H7HP. The panel surface is water-resistive (conforming to NEMA 4 and IP66). In order to prevent the internal circuit from water penetration through the space between the counter and operating panel, attach a rubber packing between the counter and operating panel and secure the rubber packing with the Y92F-3@ flush-mounting adaptor. Observe the following items to ensure the safe use of this product. Be sure the rubber packing is installed in the correct direction. The wider portion must be facing the panel when installed, as shown in the following illustration. Using a flat-head screwdriver, press in the Mounting Adapter until it cannot be pressed in any further in order to ensure water-resistive performance. Environmental Precautions Wider portion facing panel Precautions for Safe Use * Store the H7GP/H7HP within the specified ratings. If the H7GP/ H7HP has been stored at temperatures -10C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. * Use the H7GP/H7HP within the specified ratings for operating temperature and humidity. * Do not operate the H7GP/H7HP in locations subject to sudden or extreme changes in temperature, or locations where high humidity may result in condensation. * Do not use the H7GP/H7HP in locations subject to vibrations or shock. Extended use in such locations may result in damage due to stress. * Do not use the H7GP/H7HP in locations subject to excessive dust, corrosive gas, or direct sunlight. * Install the H7GP/H7HP well away from any sources of static electricity, such as pipes transporting molding materials, powders, or liquids. * The H7GP/H7HP is not waterproof or oil resistant. Do not use it in locations subject to water or oil. * The life expectancy of internal components may be reduced if the H7GP/H7HP is mounted side-by-side. * Do not use organic solvents (such as paint thinner or benzine), strong alkaline, or strong acids because they will damage the external finish. Adapter Panel Other Oil resistance is not applicable to all types of oil. Be sure to test any specific oils before actual application. Usage Precautions * Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. * Be sure to wire the terminals correctly. * Do not install input lines in the same duct or conduit as power supply or other high-voltage lines. Doing so may result in malfunction due to noise. Separate the input lines from highvoltage lines. * Internal elements may be destroyed if a voltage outside the rated voltage is applied. * Maintain voltage fluctuations in the power supply within the specified range. * Use a switch, relay, or other contact so that the rated power supply voltage will be reached within 0.1 s. If the power supply voltage is not reached quickly enough, the H7GP/H7HP may malfunction or outputs may be unstable. * Although the H7GP/H7HP power supply (primary side) is isolated from control circuits (secondary side) by a transformer, the primary and secondary sides of the transformer are linked by a capacitor, making it possible for high-frequency components to leak to the secondary side. Take adequate precautions against electrical shock. Do not connect input circuits to exposed parts (such as the machine body) and be sure that the power supply is turned off before wiring. Control circuit Display circuit Input circuit http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 8 H7HP Precaution for Correct Use Power Supplies When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Apply the power supply voltage through a relay or switch in such a way that the voltage reaches a fixed value immediately. Power supply ON OFF 200 ms 0 to 90 ms 5 ms Input Impossible 0 to 2 s Possible Unstable Impossible Unstable Self-diagnostic Function The following displays will appear if an error occurs. Display Error Correction ---- Less than -99999 (H7HP, 6-digit model) Less than -99999999 (H7HP, 8-digit model) Press RST Key or reset input e1 CPU e2 Memory Press RST Key or turn power OFF and then ON Labels Unit labels are included with the H7GP/H7HP and DIP switch labels are included with the H7HP. Attach these labels as shown in the following illustrations. Unit Labels H7GP H7HP DIP Switch Labels H7HP ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved. 9 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. 2007. 3 OMRON Corporation In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2007 All Rights Reserved.