GE Data Sheet
EVW010A0B Series (Ei
hth-Brick) DC-DC Power Modules
36–75Vdc Input; 12.0Vdc Output; 10A Output Current
October 1, 2015 ©2012 General Electric Company. All rights reserved. Page 4
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
Parameter Device Symbol Min Typ Max Unit
Remote On/Off Signal Interface
(VIN=VIN, min to VIN, max ; open collector or equivalent,
Signal referenced to VIN- terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low - Remote On/Off Current All Ion/off 1.0 mA
Logic Low - On/Off Voltage All Von/off -0.7 1.0 Vdc
Logic High Voltage – (Typ = Open Collector) All Von/off 2.0 5.0 Vdc
Logic High maximum allowable leakage current All Ion/off 10 μA
Turn-On Delay1 and Rise Times
(IO=IO, max , VIN=VIN, nom, TA = 25 oC)
Case 1: On/Off input is set to Logic Low (Module
ON) and then input power is applied (Tdelay from
instant at which VIN = VIN, min until VO = 10% of VO,set)
All Tdelay — 25 30 msec
Case 2: Input power is applied for at least 1 second
and then the On/Off input is set from OFF to ON (Tdelay from
instant Von/off toggles until VO = 10% of VO, set).
All Tdelay — 12 20 msec
Output voltage Rise time (time for Vo to rise from 10%
of Vo,set to 90% of Vo, set) All Trise — 10 15 msec
Output voltage overshoot – Startup All
— 3 % VO, set
IO= IO, max; VIN=VIN, min to VIN, max, TA = 25 oC
Remote Sense Range All VSENSE 10 % VO, set
(Max voltage drop is 0.5V)
Output Voltage Adjustment Range2 All 80 110 % VO, set
Output Overvoltage Protection All VO, limit 13.8 16.5 Vdc
Input Undervoltage Lockout All VUVLO
Turn-on Threshold 30 34.5 36 Vdc
Turn-off Threshold 30 32.5 Vdc
Hysterisis 1.5 2.0
Vdc
Input Overvoltage Lockout All VOVLO
Turn-off Threshold 80 83 Vdc
Turn-on Threshold 75 78 Vdc
Hysterisis 1 2
Vdc
Notes:
1. The module has an adaptable extended Turn-On Delay interval, Tdelay, of 4 seconds. The extended Tdelay will occur when the module restarts following either:
1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back to normal; or 2)
toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, Tdelay, will occur whenever a
module restarts with input voltage removed from the module for the preceding 1 second.
2. Maximum trim up possible only for Vin>40V.