Description



{












GSM120B seri e s
120W AC-DC Reliable Green Medical Adaptor





Features
  
 







 



+
+
μ

File Name:GSM120B-SPEC 2020-08-03
 

SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 9)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GSM120B15-R7BGSM120B12-R7B GSM120B20-R7B GSM120B24-R7B GSM120B48-R7B
15V12V
GSM120B15GSM120B12
20V
GSM120B20
24V
GSM120B24
48V
GSM120B48
120mVp-p100mVp-p 150mVp-p 180mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0% ±5.0% ±3.0% ±2.5%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
PF>0.93 / 230VAC PF>0.97 / 115VAC at full load
89%88% 89.5% 90% 91.5%
1.4A / 115VAC 0.7A / 230VAC
Cold start 35A / 115VAC 70A / 230VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 4KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
372K hrs min. MIL-HDBK-217F(25 )
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
167*67*35mm (L*W*H)
0.6Kg; 20pcs/13,0Kg/0.89CUFT
CONNECTOR
PLUG
CABLE See page 4~5; Other type available by customer requested
See page 4~5; Other type available by customer requested
OVERLOAD
OVER VOLTAGE
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
7A8.5A 6A 5A 2.5A
0 ~ 7A0 ~ 8.5A 0 ~ 6A 0 ~ 5A
0 ~ 2.5A
105W102W 120W 120W 120W
Protection type : Shut down o/p voltage, re-power on to recover
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
1500ms, 30ms / 230VAC 2000ms, 30ms / 115VAC at full load
40ms / 230VAC 24ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
Touch current < 100 A/264VAC
±5.0%
±0.03% / (0 ~ 40)
ISOLATION LEVEL Primary-Secondary: 2xMOPP







  

For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
GSM120B seri e s
120W AC-DC Reliable Green Medical Adaptor
OPERATING ALTITUDE Note.8
Parameter
Parameter
ESD
Standard
Standard
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Class B
Class B
Class A
-----
EMC IMMUNITY
EMC EMISSION
EN60601-1-2, EN61204-3
Level 4, 15KV air ; Level 4, 8KV contact
100% dip 1 periods, 30% dip 25 periods,
100% interruptions 250 periods
Level 3, 1KV/Line-Line
Level 4, 30A/m
Level 3, 10V
Level 3, 2KV
IEC60601-1/IEC60601-1-11, EN60601-1 EN , ANSI/AAMI ES60601-1 (3.1 version), / 60601-1-11 / ES60601-1-11
CAN/CSA-C22.2 No. 60601-1:14 - Edition 3 approved, EAC TP TC 004
μ
3000 meters
μ
RF field susceptibility
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field immunity
Voltage dip, interruption
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
File Name:GSM120B-SPEC 2020-08-03
Level 3, 10V/m( 80MHz~2.7GHz )
Table 9, 9~28V/m( 385MHz~5.78GHz )
EN55011 (CISPR11), FCC PART 15 / CISPR22,
CAN ICES-3(B)/NMB-3(B)
EN55011 (CISPR11), FCC PART 15 / CISPR22,
CAN ICES-3(B)/NMB-3(B)
Derating Curve Static Characteristics
Mechanical Specification Case No. GS120A Unit:mm
INPUT VOLTAGE (VAC) 60Hz
80 10090 120110 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
35 167
67
Power LED
30±3mm
UL2464 16AWGx4C 1000±50mm for 12V
UL2464 18AWGx4C 1200±50mm for 15 ~ 48V
GSM120B seri e s
120W AC-DC Reliable Green Medical Adaptor
AC Inlet
IEC320-C8
PIN NO.
1
2
3
4
OUTPUT
+Vo
-Vo
-Vo
+Vo
23
14
2
1 4
3
KYCON KPPX-4P equivalent
Standard plug: R7B
R7B Pin Assignment
DC output plug
AMBIENT TEMPERATURE ()
LOAD (%)
0-30 2010 30 40
20
50
80
100
6050 70 (HORIZONTAL)
40
60
File Name:GSM120B-SPEC 2020-08-03
GSM120B seri e s
120W AC-DC Reliable Green Medical Adaptor
File Name:GSM120B-SPEC 2020-08-03
Available for 15 ~ 48V
Optional DC plug: (Available in customized cable or quick adapter)
DC plug changeable through:
(1) Customization of the standard part with an optional DC plug according to the table (MOQ applicable)
(2) Quick adapter accessory (sold separately without MOQ)
Please refer to below table and online selection guide :
Example quick adapter accessory:
(Current rating: 7.5A max.)
Type No. ABC
OD ID L
P1M 5.5 2.5 11.0
P1J 5.5 2.1 11.0
Tuning Fork Style
B
AC
(Straight)
Quick Adapter
Accessory
Type No.
MOLEX 39-01-2060 (4.2mm) equivalent
Pin Assignment
PIN No.Output
1
2
3
4
5
+Vo
+Vo
-Vo
+Vo
-Vo
321
654
6-Vo
C6P
MIC4
Pin Assignment
1
2
PIN No.Output
NEUTRIK XLR NC4FX equivalent
3
4
Type No.
+Vo
+Vo
-Vo
-Vo
R1B
25
3
1
4
1
2
4
3
R7BF
+Vo
-Vo
Type No.
KYCON KPJX-CM-4S equivalent
Pin Assignment
PIN No.Output
1
2
3
4+Vo
-Vo
Min. DIN 4 Pin with Lock (female)
None
-Vo
-Vo
Type No. Pin Assignment
PIN No.Output
1
2
3
4-Vo
+Vo
None
DIN 5 Pin (male)
5+Vo
None
None
41
32
FG not connected to output connector
GSM120B seri e s
120W AC-DC Reliable Green Medical Adaptor
File Name:GSM120B-SPEC 2020-08-03
Length of Land L1 by request
( ’s standard length, L: mm, L1: mm)
MW 25 5
by customer
2
1
L1
L
2
1
Stripped and tinned leads
+Vo
-Vo
Pin Assignment
PIN No.Output
Type No.
None
(black,white)
(red,blue)
Quick Adapter
Accessory
1
2
3
4
C4P
+Vo
+Vo
Type No.
AMP 1-480702-0 (6.35mm) equivalent Pin Assignment
PIN No.Output
1
2
3
4-Vo
-Vo
None
FG not connected to output connector
Installation Manual