HPS3000 Series Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn
Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of
this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn
Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other
names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners.
© 2015 Artesyn Embedded Technologies, Inc.
www.artesyn.com
HPS3000 Series DS 01-30-2015
MTBF
The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6 specication @ 25 °C and 40 °C, ambient, at full load.
With the power supply installed in a system in a 25 °C ambient environment and operating at full load, capacitor life shall be 10 years, minimum for
ALL electrolytic capacitors contained within this power supply. The power supply shall demonstrate a MTBF level of > 500,000 hours.
Quality Assurance
Full QAV testing shall be conducted in accordance with Artesyn Embedded Technologies Standards with reports available upon request.
Warranty
Artesyn Embedded Technologies shall warrant the power supply to be free of defects in materials and workmanship for a minimum period of two
years from the date of shipment, when operated within specications. The warranty shall be fully transferable to the end owner of the equipment
powered by the supply.
Ordering Information
Model Number Main Output Main Output Current Standby Output Standby Current
HPS3000-9 48 Vdc 62.0 A 5.0 V 3.0 A
HPS3000-9-001 48 Vdc 62.0 A 5.0 V 3.0 A
Signals and Controls - All Models
LED INDICATORS
There will be a green POWER LED (PWR) to indicate that AC is applied to the PSU and standby voltage is available when blinking. This same LED
should go solid when the 48 V output is enabled and operational.
There will be an Amber Power Supply Fail LED (FAIL) to indicate that the power supply has failed and a replacement of the unit is necessary. Faults
including UVP, OVP, OTP, or Fan Fail when PSON# is asserted “Logic Low” shall cause the amber LED to turn on. The LED can be turned off by
recycling PSON# signal or by an AC power interruption more than 1 second. The LED shall be off when PSON# is not asserted “Logic Low”. Refer
to table 13 for conditions of the LED’s:
Table 13 LED Indicators
Power Supply Condition Power LED (GREEN) Fail LED (AMBER)
No AC power to PSU OFF OFF
AC present / Standby Output On Blinking OFF
Power supply 48 V output ON and OK ON OFF
Power supply failure (includes overvoltage,
overtemperature)
OFF ON
Current limit ON Blinking
Note: HPS3000-9-001 version is recommended for applications where higher airow is required.