TP3070,TP3070-X,TP3071
TP3070, TP3071, TP3070-X COMBO II Programmable PCM CODEC/Filter
Literature Number: SNOSBX9
TP3070, TP3071, TP3070-X
COMBO®II Programmable PCM CODEC/Filter
General Description
The TP3070 and TP3071 are second-generation combined
PCM CODEC and Filter devices optimized for digital switch-
ing applications on subscriber line and trunk cards. Using
advanced switched capacitor techniques, COMBO II com-
bines transmit bandpass and receive lowpass channel filters
with a companding PCM encoder and decoder. The devices
are A-law and µ-law selectable and employ a conventional
serial PCM interface capable of being clocked up to
4.096 MHz. A number of programmable functions may be
controlled via a serial control port.
Channel gains are programmable over a 25.4 dB range in
each direction, and a programmable filter is included to en-
able Hybrid Balancing to be adjusted to suit a wide range of
loop impedance conditions. Both transformer and active
SLIC interface circuits with real or complex termination im-
pedances can be balanced by this filter, with cancellation in
excess of 30 dB being readily achievable when measured
across the passband against standard test termination net-
works.
To enable COMBO II to interface to the SLIC control leads, a
number of programmable latches are included; each may be
configured as either an input or an output. The TP3070 pro-
vides 6 latches and the TP3071 5 latches.
Features
nComplete CODEC and FILTER system including:
Transmit and receive PCM channel filters
µ-law or A-law companding encoder and decoder
Receive power amplifier drives 300
4.096 MHz serial PCM data (max)
nProgrammable Functions:
Transmit gain: 25.4 dB range, 0.1 dB steps
Receive gain: 25.4 dB range, 0.1 dB steps
Hybrid balance cancellation filter
Time-slot assignment; up to 64 slots/frame
2 port assignment (TP3070)
6 interface latches (TP3070)
A or µ-law
Analog loopback
Digital loopback
nDirect interface to solid-state SLICs
nSimplifies transformer SLIC; single winding secondary
nStandard serial control interface
n80 mW operating power (typ)
n1.5 mW standby power (typ)
nDesigned for CCITT and LSSGR applications
nTTL and CMOS compatible digital interfaces
nExtended temperature versions available for −40˚C to
+85˚C (TP3070V-X)
Note: See also AN-614, COMBO II application guide.
COMBO®and TRI-STATE®are registered trademarks of National Semiconductor Corporation.
April 1994
TP3070, TP3071, TP3070-X COMBO II Programmable PCM CODEC/Filter
© 1999 National Semiconductor Corporation DS008635 www.national.com
Block Diagram
Connection Diagrams
Pin Descriptions
Pin Description
V
CC
+5V ±5%power supply.
V
BB
−5V ±5%power supply.
GND Ground. All analog and digital signals are
referenced to this pin.
FS
X
Transmit Frame Sync input. Normally a pulse
or squarewave with an 8 kHz repetition rate is
applied to this input to define the start of the
transmit time slot assigned to this device
(non-delayed data timing mode), or the start of
the transmit frame (delayed data timing mode
using the internal time-slot assignment
counter).
DS008635-1
FIGURE 1.
DS008635-4
Order Number TP3070V
(0˚C to +70˚C)
Order Number TP3070V-X
(−40˚C to +85˚C)
See NS Package Number V28A
DS008635-2
Order Number TP3071J
See NS Package Number J20A
Order Number TP3071N
See NS Package Number N20A
www.national.com 2
Pin Descriptions (Continued)
Pin Description
FS
R
Receive Frame Sync input. Normally a pulse
or squarewave with an 8 kHz repetition rate is
applied to this input to define the start of the
receive time slot assigned to this device
(non-delayed data timing mode), or the start of
the receive frame (delayed data timing mode
using the internal time-slot assignment
counter).
BCLK Bit clock input used to shift PCM data into and
out of the D
R
and D
X
pins. BCLK may vary
from 64 kHz to 4.096 MHz in 8 kHz
increments, and must be synchronous with
MCLK.
MCLK Master clock input used by the switched
capacitor filters and the encoder and decoder
sequencing logic. Must be 512 kHz, 1.536
MHz, 1.544 MHz, 2.048 MHz or 4.096 MHz
and synchronous with BCLK.
VF
X
I The Transmit analog high-impedance input.
Voice frequency signals present on this input
are encoded as an A-law or µ-law PCM bit
stream and shifted out on the selected D
X
pin.
VF
R
O The Receive analog power amplifier output,
capable of driving load impedances as low as
300(depending on the peak overload level
required). PCM data received on the assigned
D
R
pin is decoded and appears at this output
as voice frequency signals.
D
X
0
D
X
1D
X
1 is available on the TP3070 only; D
X
0is
available on all devices. These Transmit Data
TRI-STATE®outputs remain in the high
impedance state except during the assigned
transmit time slot on the assigned port, during
which the transmit PCM data byte is shifted
out on the rising edges of BCLK.
TS
X
0
TS
X
1TS
X
1 is available on the TP3070 only; TS
X
0is
available on all devices. Normally these
open-drain outputs are floating in a high
impedance state except when a time-slot is
active on one of the D
X
outputs, when the
appropriate TS
X
output pulls low to enable a
backplane line-driver.
D
R
0
D
R
1D
R
1 is available on the TP3070 only; D
R
0is
available on all devices. These receive data
inputs are inactive except during the assigned
receive time slot of the assigned port when
the receive PCM data is shifted in on the
falling edges of BCLK.
CCLK Control Clock input. This clock shifts serial
control information into or out from CI/O or CI
and CO when the CS input is low, depending
on the current instruction. CCLK may be
asynchronous with the other system clocks.
Pin Description
CI/O This is the Control Data I/O pin which is
provided on the TP3071. Serial control
information is shifted to or read from COMBO
II on this pin when CS is low. The direction of
the data is determined by the current
instruction as defined in
Table 1
.
CI This is a separate Control Input, available only
on the TP3070. It can be connected to CO if
required.
CO This is a separate Control Output, available
only on the TP3070. It can be connected to CI
if required.
CS Chip Select input. When this pin is low, control
information can be written to or read from
COMBO II via the CI/O pin (or CI and CO).
IL5–IL0 IL5 through IL0 are available on the TP3070.
IL4 through IL0 are available on the TP3071.
Each Interface Latch I/O pin may be
individually programmed as an input or an
output determined by the state of the
corresponding bit in the Latch Direction
Register (LDR). For pins configured as inputs,
the logic state sensed on each input is latched
into the Interface Latch Register (ILR)
whenever control data is written to COMBO II,
while CS is low, and the information is shifted
out on the CO (or CI/O) pin. When configured
as outputs, control data written into the ILR
appears at the corresponding IL pins.
MR This logic input must be pulled low for normal
operation of COMBO II. When pulled
momentarily high (at least 1 µsec.), all
programmable registers in the device are reset
to the states specified under “Power-On
Initialization”.
NC No Connection. Do not connect to this pin. Do
not route traces through this pin.
Functional Description
POWER-ON INITIALIZATION
When power is first applied, power-on reset circuitry initial-
izes the COMBO II and puts it into the power-down state.
The gain control registers for the transmit and receive gain
sections are programmed to OFF (00000000), the hybrid
balance circuit is turned off, the power amp is disabled and
the device is in the non-delayed timing mode. The Latch Di-
rection Register (LDR) is pre-set with all IL pins programmed
as inputs, placing the SLIC interface pins in a high imped-
ance state. The CI/O pin is set as an input ready for the first
control byte of the initialization sequence. Other initial states
in the Control Register are indicated in Section 2.0.
Areset to these same initial conditions may also be forced by
driving the MR pin momentarily high. This may be done ei-
ther when powered-up or down. For normal operation this
pin must be pulled low. If not used, MR should be hard-wired
to ground.
The desired modes for all programmable functions may be
initialized via the control port prior to a Power-up command.
www.national.com3
Functional Description (Continued)
POWER-DOWN STATE
Following a period of activity in the powered-up state the
power-down state may be re-entered by writing any of the
control instructions into the serial control port with the “P” bit
set to “1” as indicated in
Table 1
. It is recommended that the
chip be powered down before writing any additional instruc-
tions. In the power-down state, all non-essential circuitry is
de-activated and the D
X
0 (and D
X
1) outputs are in the high
impedance TRI-STATE condition.
The coefficients stored in the Hybrid Balance circuit and the
Gain Control registers, the data in the LDR and ILR, and all
control bits remain unchanged in the power-down state un-
less changed by writing new data via the serial control port,
which remains active. The outputs of the Interface Latches
also remain active, maintaining the ability to monitor and
control the SLIC.
TRANSMIT FILTER AND ENCODER
The Transmit section input, VF
X
I, is a high impedance sum-
ming input which is used as the differencing point for the in-
ternal hybrid balance cancellation signal. No external com-
ponents are necessary to set the gain. Following this circuit
is a programmable gain/attenuation amplifier which is con-
trolled by the contents of the Transmit Gain Register (see
Programmable Functions section). An active pre-filter then
precedes the 3rd order high-pass and 5th order low-pass
switched capacitor filters. The A/D converter has a com-
pressing characteristic according to the standard CCITTA or
µ255 coding laws, which must be selected by a control in-
struction during initialization (see
Table 1
and
Table 2
).Apre-
cision on-chip voltage reference ensures accurate and highly
stable transmission levels. Any offset voltage arising in the
gain-set amplifier, the filters or the comparator is canceled by
an internal auto-zero circuit.
Each encode cycle begins immediately following the as-
signed Transmit time-slot. The total signal delay referenced
to the start of the time-slot is approximately 165 µs (due to
the Transmit Filter) plus 125 µs (due to encoding delay),
which totals 290 µs. Data is shifted out on D
X
0orD
X
1 during
the selected time slot on eight rising edges of BCLK.
DECODER AND RECEIVE FILTER
PCM data is shifted into the Decoder’s Receive PCM Regis-
ter via the D
R
0orD
R
1 pin during the selected time-slot on
the 8 falling edges of BCLK. The Decoder consists of an ex-
panding DAC with either A or µ255 law decoding character-
istic, which is selected by the same control instruction used
to select the Encode law during initialization. Following the
Decoder is a 5th order low-pass switched capacitor filter with
integral Sin x/x correction for the 8 kHz sample and hold. A
programmable gain amplifier, which must be set by writing to
the Receive Gain Register, is included, and finally a Power
Amplifier capable of driving a 300load to ±3.5V, a 600
load to ±3.8V or a 15 kload to ±4.0V at peak overload.
A decode cycle begins immediately after the assigned re-
ceive time-slot, and 10 µs later the Decoder DAC output is
updated. The total signal delay is 10 µs plus 120 µs (filter de-
lay) plus 62.5 µs (
1
2
frame) which gives approximately 190
µs.
PCM INTERFACE
The FS
X
and FS
R
frame sync inputs determine the begin-
ning of the 8-bit transmit and receive time-slots respectively.
They may have any duration from a single cycle of BCLK
HIGH to one MCLK period LOW. Two different relationships
may be established between the frame sync inputs and the
actual time-slots on the PCM busses by setting bit 3 in the
Control Register (see
Table 2
). Non-delayed data mode is
similar to long-frame timing on the TP3050/60 series of de-
vices (COMBO); time-slots begin nominally coincident with
the rising edge of the appropriate FS input. The alternative is
to use Delayed Data mode, which is similar to short-frame
sync timing on COMBO, in which each FS input must be high
at least a half-cycle of BCLK earlier than the time-slot. The
Time-Slot Assignment circuit on the device can only be used
with Delayed Data timing.
When using Time-Slot Assignment, the beginning of the first
time-slot in a frame is identified by the appropriate FS input.
The actual transmit and receive time-slots are then deter-
mined by the internal Time-Slot Assignment counters.
Transmit and Receive frames and time-slots may be skewed
from each other by any number of BCLK cycles. During each
assigned Transmit time-slot, the selected D
X
0/1 output shifts
data out from the PCM register on the rising edges of BCLK.
TS
X
0 (or TS
X
1 as appropriate) also pulls low for the first 7
1
2
bit times of the time-slot to control the TRI-STATE Enable of
a backplane line-driver. Serial PCM data is shifted into the
selected D
R
0/1 input during each assigned Receive time-slot
on the falling edges of BCLK. D
X
0orD
X
1 and D
R
0orD
R
1
are selectable on the TP3070 only, see Section 6.
www.national.com 4
Functional Description (Continued)
TABLE 1. Programmable Register Instructions
Function Byte 1 (Note 1) Byte 2 (Note 1)
76543210 76543210
Single Byte Power-Up/Down PXXXXX0X None
Write Control Register P 000001X See
Table 2
Read-Back Control Register P 000011X See
Table 2
Write to Interface Latch Register P 000101X See
Table 4
Read Interface Latch Register P 000111X See
Table 4
Write Latch Direction Register P 001001X See
Table 3
Read Latch Direction Register P 001011X See
Table 3
Write Receive Gain Register P 010001X See
Table 8
Read Receive Gain Register P 010011X See
Table 8
Write Transmit Gain Register P 010101X See
Table 7
Read Transmit Gain Register P 010111X See
Table 7
Write Receive Time-Slot/Port P 100101X See
Table 6
Read-Back Receive Time-Slot/Port P 100111X See
Table 6
Write Transmit Time-Slot/Port P 101001X See
Table 6
Read-Back Transmit Time-Slot/Port P 101011X See
Table 6
Write Hybrid Balance Register 1 P 011001X Derive from
Optimization
Routine in
TP3077SW
Program
Read Hybrid Balance Register 1 P 011011X
Write Hybrid Balance Register 2 P 011101X
Read Hybrid Balance Register 2 P 011111X
Write Hybrid Balance Register 3 P 100001X
Read Hybrid Balance Register 3 P 100011X
Note 1: Bit 7 of bytes 1 and 2 is always the first bit clocked into or out from the CI, CO or CI/O pin. X =don’t care.
Note 2: “P” is the power-up/down control bit, see “Power-Up/Down Control” section. (“0” =Power Up, “1” =Power Down)
Note 3: Other register address codes are invalid and should not be used.
SERIAL CONTROL PORT
Control information and data are written into or read-back
from COMBO II via the serial control port consisting of the
control clock CCLK, the serial data input/output CI/O, (or
separate input, CI, and output, CO, on the TP3070 only), and
the Chip Select input, CS. All control instructions require 2
bytes, as listed in
Table 1
, with the exception of a single byte
power-up/down command. The byte 1 bits are used as fol-
lows: bit 7 specifies power up or power down; bits 6, 5, 4 and
3 specify the register address; bit 2 specifies whether the in-
struction is read or write; bit 1 specifies a one or two byte in-
struction; and bit 0 is not used.
To shift control data into COMBO II, CCLK must be pulsed 8
times while CS is low. Data on the CI/O (or CI) input is
shifted into the serial input register on the falling edge of
each CCLK pulse. After all data is shifted in, the contents of
the input shift register are decoded, and may indicate that a
2nd byte of control data will follow. This second byte may ei-
ther be defined by a second byte-wide CS pulse or may fol-
low the first contiguously, i.e. it is not mandatory for CS to re-
turn high between the first and second control bytes. At the
end of CCLK8 in the 2nd control byte the data is loaded into
the appropriate programmable register. CS may remain low
continuously when programming successive registers, if de-
sired. However, CS should be set high when no data trans-
fers are in progress.
To readback Interface Latch data or status information from
COMBO II, the first byte of the appropriate instruction is
strobed in while CS is low, as defined in
Table 1
. CS must be
kept low, or be taken low again for a further 8 CCLK cycles,
during which the data is shifted onto the CO or CI/O pin on
the rising edges of CCLK. When CS is high the CO or CI/O
pin is in the high-impedance TRI-STATE, enabling the CI/O
pins of many devices to be multiplexed together.
If CS returns high during either byte 1 or byte 2 before all
eight CCLK pulses of that byte occur, both the bit count and
byte count are reset and register contents are not affected.
This prevents loss of synchronization in the control interface
as well as corruption of register data due to processor inter-
rupt or other problem. When CS returns low again, the de-
vice will be ready to accept bit 1 of byte 1 of a new instruc-
tion.
Programmable Functions
1.0 POWER-UP/DOWN CONTROL
Following power-on initialization, power-up and power-down
control may be accomplished by writing any of the control in-
structions listed in
Table 1
into COMBO II with the “P” bit set
to “0” for power-up or “1” for power-down. Normally it is rec-
ommended that all programmable functions be initially pro-
grammed while the device is powered down. Power state
control can then be included with the last programming in-
struction or the separate single-byte instruction. Any of the
programmable registers may also be modified while the de-
www.national.com5
Programmable Functions (Continued)
vice is powered-up or down by setting the “P” bit as indi-
cated. When the power-up or down control is entered as a
single byte instruction, bit one (1) must be reset to a 0.
When a power-up command is given, all de-activated circuits
are activated, but the TRI-STATE PCM output(s), D
X
0 (and
D
X
1), will remain in the high impedance state until the sec-
ond FS
X
pulse after power-up.
2.0 CONTROL REGISTER INSTRUCTION
The first byte of a READ or WRITE instruction to the Control
Register is as shown in
Table 1
. The second byte has the fol-
lowing bit functions:
TABLE 2. Control Register Byte 2 Functions
Bit Number and Name
76 5 43210 Function
F1F0MA IA DN DL AL PP
0 0 MCLK =512 kHz
0 1 MCLK =1.536
or 1.544 MHz
1 0 MCLK =2.048 MHz
(Note 4)
1 1 MCLK =4.096 MHz
0 X Select µ-255 law (Note 4)
1 0 A-law, Including Even
Bit Inversion
1 1 A-law, No Even Bit Inversion
0 Delayed Data Timing
1 Non-Delayed Data
Timing (Note 4)
0 0 Normal Operation
(Note 4)
1 X Digital Loopback
0 1 Analog Loopback
0 Power Amp Enabled in PDN
1 Power Amp Disabled in
PDN (Note 4)
Note 4: State at power-on initialization. (Bit 4 =0)
2.1 Master Clock Frequency Selection
A Master clock must be provided to COMBO II for operation
of the filter and coding/decoding functions. The MCLK fre-
quency must be either 512 kHz, 1.536 MHz, 1.544 MHz,
2.048 MHz, or 4.096 MHz and must be synchronous with
BCLK. Bits F
1
and F
0
(see
Table 2
) must be set during initial-
ization to select the correct internal divider.
2.2 Coding Law Selection
Bits “MA” and “IA” in
Table 2
permit the selection of µ255
coding or A-law coding, with or without even bit inversion.
2.3 Analog Loopback
Analog Loopback mode is entered by setting the “AL” and
“DL” bits in the Control Register as shown in
Table 2
.Inthe
analog loopback mode, the Transmit input VF
X
I is isolated
from the input pin and internally connected to the VF
R
O out-
put, forming a loop from the Receive PCM Register back to
the Transmit PCM Register. The VF
R
O pin remains active,
and the programmed settings of the Transmit and Receive
gains remain unchanged, thus care must be taken to ensure
that overload levels are not exceeded anywhere in the loop.
Hybrid balance must be disabled for meaningful analog loop-
back function.
2.4 Digital Loopback
Digital Loopback mode is entered by setting the “AL” and
“DL” bits in the Control Register as shown in
Table 2
. This
mode provides another stage of path verification by enabling
data written into the Receive PCM Register to be read back
from that register in any Transmit time-slot at D
X
0/1. In digital
loopback, the decoder will remain functional and output a
signal at VF
R
O. If this is undesirable, the receive output can
be turned off by programming the receive gain register to all
zeros.
3.0 INTERFACE LATCH DIRECTIONS
Immediately following power-on, all Interface Latches as-
sume they are inputs, and therefore all IL pins are in a high
impedance state. Each IL pin may be individually pro-
grammed as a logic input or output by writing the appropriate
instruction to the LDR, see
Table 1
and
Table 3
. For mini-
mum power dissipation, unconnected latch pins should be
programmed as outputs. For the TP3071, L5 should always
be programmed as an output.
Bits L
5
–L
0
must be set by writing the specified instruction to
the LDR with the L bits in the second byte set as follows:
TABLE 3. Byte 2 Functions of Latch Direction Register
Byte 2 Bit Number
76543210
L
0
L
1
L
2
L
3
L
4
L
5
XX
L
n
Bit IL Direction
0 Input
1 Output
X=don’t care
INTERFACE LATCH STATES
Interface Latches configured as outputs assume the state
determined by the appropriate data bit in the 2-byte instruc-
tion written to the Interface Latch Register (ILR) as shown in
Table 1
and
Table 4
. Latches configured as inputs will sense
the state applied by an external source, such as the
Off-Hook detect output of a SLIC. All bits of the ILR, i.e.
sensed inputs and the programmed state of outputs, can be
read back in the 2nd byte of a READ from the ILR.
It is recommended that during initialization, the state of IL
pins to be configured as outputs should be programmed first,
followed immediately by the Latch Direction Register.
TABLE 4. Interface Latch Data Bit Order
Bit Number
76543210
D
0
D
1
D
2
D
3
D
4
D
5
XX
www.national.com 6
Programmable Functions (Continued)
TABLE 5. Coding Law Conventions
µ255 law True A-law with A-law without
even bit inversion even bit inversion
MSB LSB MSB LSB MSB LSB
V
IN
=+Full Scale 10000000 10101010 11111111
V
IN
=0V 11111111 11010101 10000000
01111111 01010101 00000000
V
IN
=−Full Scale 00000000 00101010 01111111
Note 5: The MSB is always the first PCM bit shifted in or out of COMBO II.
TABLE 6. Time-Slot and Port Assignment Instruction
Bit Number and Name Function
7 6 5 43210
EN PS T
5
T
4
T
3
T
2
T
1
T
0
(Note 6) (Note 7)
0 0 X XXXXXDisable D
X
0 Output (Transmit Instruction)
Disable D
R
0 Input (Receive Instruction)
0 1 X XXXXXDisable D
X
1 Output (Transmit Instruction)
Disable D
R
1 Input (Receive Instruction)
1 0 Assign One Binary Coded Time-Slot from 0–63 Enable D
X
0 Output (Transmit Instruction)
Assign One Binary Coded Time-Slot from 0–63 Enable D
R
0 Input (Receive Instruction)
1 1 Assign One Binary Coded Time-Slot from 0–63 Enable D
X
1 Output (Transmit Instruction)
Assign One Binary Coded Time-Slot from 0–63 Enable D
R
1 Input (Receive Instruction)
Note 6: The “PS” bit MUST always be set to 0 for the TP3071.
Note 7: T5 is the MSB of the Time-slot assignment bit field. Time slot bits should be set to “000000” for both transmit and receive when operating in non-delayed
data timing mode.
5.0 TIME-SLOT ASSIGNMENT
COMBO II can operate in either fixed time-slot or time-slot
assignment mode for selecting the Transmit and Receive
PCM time-slots. Following power-on, the device is automati-
cally in Non-Delayed Timing mode, in which the time-slot al-
ways begins with the leading (rising) edge of frame sync in-
puts FS
X
and FS
R
. Time-Slot Assignment may only be used
with Delayed Data timing; see
Figure 5
.FS
X
and FS
R
may
have any phase relationship with each other in BCLK period
increments.
Alternatively, the internal time-slot assignment counters and
comparators can be used to access any time-slot in a frame,
using the frame sync inputs as marker pulses for the begin-
ning of transmit and receive time-slot 0. In this mode, a
frame may consist of up to 64 time-slots of 8 bits each. A
time-slot is assigned by a 2-byte instruction as shown in
Table 1
and
Table 6
. The last 6 bits of the second byte indi-
cate the selected time-slot from 0–63 using straight binary
notation. When writing a timeslot and port assignment regis-
ter, if the PCM interface is currently active, it is immediately
deactivated to prevent possible bus clashes. A new assign-
ment becomes active on the second frame following the end
of the Chip-Select for the second control byte. Rewriting of
register contents should not be performed during the talking
period of a connection to prevent waveform distortion
caused by loss of a sample which will occur with each regis-
ter write. The “EN” bit allows the PCM inputs, D
R
0/1, or out-
puts, D
X
0/1, as appropriate, to be enabled or disabled.
Time-Slot Assignment mode requires that the FS
X
and FS
R
pulses must conform to the delayed data timing format
shown in
Figure 5
.
6.0 PORT SELECTION
On the TP3070 only, an additional capability is available; 2
Transmit serial PCM ports, D
X
0 and D
X
1, and 2 Receive se-
rial PCM ports, D
R
0 and D
R
1, are provided to enable
two-way space switching to be implemented. Port selections
for transmit and receive are made within the appropriate
time-slot assignment instruction using the “PS” bit in the sec-
ond byte. The PS bit selects either Port 0 or Port 1. Both
ports cannot be active at the same time.
On the TP3071, only ports D
X
0 and D
R
0 are available, there-
fore the “PS” bit MUST always be set to 0 for these devices.
Table 6
shows the format for the second byte of both trans-
mit and receive time-slot and port assignment instructions.
7.0 TRANSMIT GAIN INSTRUCTION BYTE 2
The transmit gain can be programmed in 0.1 dB steps by
writing to the Transmit Gain Register as defined in
Table 1
and
Table 7
. This corresponds to a range of 0 dBm0 levels at
VF
X
I between 1.619 Vrms and 0.087 Vrms (equivalent to
+6.4 dBm to −19.0 dBm in 600).
To calculate the binary code for byte 2 of this instruction for
any desired input 0 dBm0 level in Vrms, take the nearest in-
teger to the decimal number given by:
200 x log
10
(V/0.08595)
www.national.com7
Programmable Functions (Continued)
and convert to the binary equivalent. Some examples are
given in
Table 7
and a complete tabulation is given in Appen-
dix I of AN-614.
It should be noted that the Transmit (idle channel) Noise and
Transmit Signal to Total Distortion are both specified with
transmit gain set to 0 dB (Gain Register set to all ones). At
high transmit gains there will be some degradation in noise
performance for these parameters. See Application Note
AN-614 for more information on this subject.
TABLE 7. Byte 2 of Transmit Gain Instruction
Bit Number 0 dBm0 Test Level (Vrms)
76543210 atVF
X
I
00000000 NoOutput (Note 8)
00000001 0.087
00000010 0.088
——
11111110 1.600
11111111 1.619
Note 8: Analog signal path is cut off, but DXremains active and will output
codes representing idle noise.
8.0 RECEIVE GAIN INSTRUCTION BYTE 2
The receive gain can be programmed in 0.1 dB steps by writ-
ing to the Receive Gain Register as defined in
Table 1
and
Table 8
. Note the following restrictions on output drive capa-
bility:
a) 0 dBm0 levels 1.96 Vrms at VF
R
O may be driven into
a load of 15 kto GND; receive gain set to 0 dB (Gain
Register set to all ones)
b) 0 dBm0 levels 1.85 Vrms at VF
R
O may be driven into
a load of 600to GND; receive gain set to −0.5 dB
c) 0 dBm0 levels 1.71 Vrms at VF
R
O may be driven into
a load of 300to GND; receive gain set to −1.2 dB
To calculate the binary code for byte 2 of this instruction for
any desired output 0 dBm0 level in Vrms, take the nearest in-
teger to the decimal number given by:
200 x log
10
(V/0.1043)
and convert to the binary equivalent. Some examples are
given in
Table 8
and a complete tabulation is given in Appen-
dix I of AN-614.
TABLE 8. Byte 2 of Receive Gain Instruction
Bit Number 0 dBm0 Test Level (Vrms)
76543210 atVF
R
O
00000000 NoOutput (Low Z to GND)
00000001 0.105
00000010 0.107
——
11111110 1.941
11111111 1.964
9.0 HYBRID BALANCE FILTER
The Hybrid Balance Filter on COMBO II is a programmable
filter consisting of a second-order section, Hybal1, followed
by a first-order section, Hybal2, and a programmable attenu-
ator. Either of the filter sections can be bypassed if only one
is required to achieve good cancellation. A selectable 180
degree inverting stage is included to compensate for inter-
face circuits which also invert the transmit input relative to
the receive output signal. The 2nd order section is intended
mainly to balance low frequency signals across a trans-
former SLIC, and the first order section to balance midrange
to higher audio frequency signals.
As a 2nd order section, Hybal1 has a pair of low frequency
zeroes and a pair of complex conjugate poles. When config-
uring Hybal1, matching the phase of the hybrid at low to
mid-band frequencies is most critical. Once the echo path is
correctly balanced in phase, the magnitude of the cancella-
tion signal can be corrected by the programmable attenua-
tor.
The 2nd order mode of Hybal1 is most suitable for balancing
interfaces with transformers having high inductance of 1.5
Henries or more. An alternative configuration for smaller
transformers is available by converting Hybal1 to a simple
first-order section with a single real low-frequency pole and
zero. In this mode, the pole/zero frequency may be pro-
grammed.
Many line interfaces can be adequately balanced by use of
the Hybal1 section only, in which case the Hybal2 filter
should be de-selected to bypass it.
Hybal2, the higher frequency first-order section, is provided
for balancing an electronic SLIC, and is also helpful with a
transformer SLIC in providing additional phase correction for
mid and high-band frequencies, typically 1 kHz to 3.4 kHz.
Such a correction is particularly useful if the test balance im-
pedance includes a capacitor of 100 nF or less, such as the
loaded and non-loaded loop test networks in the United
States. Independent placement of the pole and zero location
is provided.
Figure 2
shows a simplified diagram of the local echo path
for a typical application with a transformer interface. The
magnitude and phase of the local echo signal, measured at
VF
X
I, are a function of the termination impedance Z
T
, the line
transformer and the impedance of the 2W loop, Z
L
. If the im-
pedance reflected back into the transformer primary is ex-
pressed as Z
L
' then the echo path transfer function from
VF
R
OtoVF
X
I is: H(w) =Z
L
'/(Z
T
+Z
L
') (1)
9.1 PROGRAMMING THE FILTER
On initial power-up, the Hybrid Balance filter is disabled. Be-
fore the hybrid balance filter can be programmed it is neces-
sary to design the transformer and termination impedance in
order to meet system 2W input return loss specifications,
which are normally measured against a fixed test impedance
(600 or 900in most countries). Only then can the echo
path be modeled and the hybrid balance filter programmed.
Hybrid balancing is also measured against a fixed test im-
pedance, specified by each national Telecom administration
to provide adequate control of talker and listener echo over
the majority of their network connections. This test imped-
ance is Z
L
in
Figure 2
. The echo signal and the degree of
transhybrid loss obtained by the programmable filter must be
measured from the PCM digital input, D
R
0, to the PCM digi-
tal output, D
X
0, either by digital test signal analysis or by
conversion back to analog by a PCM CODEC/Filter.
www.national.com 8
Programmable Functions (Continued)
Three registers must be programmed in COMBO II to fully
configure the Hybrid Balance Filter as follows:
Register 1: select/de-select Hybrid Balance Filter;
invert/non-invert cancellation signal;
select/de-select Hybal2 filter section;
attenuator setting.
Register 2: select/de-select Hybal1 filter;
set Hybal1 to 2nd order or 1st order;
pole and zero frequency selection.
Register 3: program pole frequency in Hybal2 filter;
program zero frequency in Hybal2 filter.
Standard filter design techniques may be used to model the
echo path (see
Equation (1)
) and design a matching hybrid
balance filter configuration. Alternatively, the frequency re-
sponse of the echo path can be measured and the hybrid
balance filter designed to replicate it.
A Hybrid Balance filter design guide and software optimiza-
tion program are available under license from National Semi-
conductor Corporation; order TP3077SW.
Applications Information
Figure 3
shows a typical application of the TP3071 together
with a typical monolithic SLIC. Four of the IL latches are con-
figured as outputs to control the relay drivers on the SLIC,
while IL4 is an input for the Supervision signal.
POWER SUPPLIES
While the pins of the TP3070 COMBO II devices are well
protected against electrical misuse, it is recommended that
the standard CMOS practice of applying GND to the device
before any other connections are made should always be
followed. In applications where the printed circuit card may
be plugged into a hot socket with power and clocks already
present, extra long pins on the connector should be used for
ground and V
BB
. In addition, a Schottky diode should be con-
nected between V
BB
and ground.
To minimize noise sources, all ground connections to each
device should meet at a common point as close as possible
to the device GND pin in order to prevent the interaction of
ground return currents flowing through a common bus im-
pedance. Power supply decoupling capacitors of 0.1 µF
should be connected from this common device ground point
to V
CC
and V
BB
as close to the device pins as possible. V
CC
and V
BB
should also be decoupled with Low Effective Series
Resistance Capacitors of at least 10 µF located near the
card edge connector.
Further guidelines on PCB layout techniques are provided in
Application NoteAN-614, COMBO IIProgrammable PCM
CODEC/Filter Family Application Guide”.
DS008635-5
FIGURE 2. Simplified Diagram of Hybrid Balance Circuit
www.national.com9
Applications Information (Continued)
DS008635-7
FIGURE 3. Typical Application with Monolithic SLIC
www.national.com 10
Absolute Maximum Ratings (Note 9)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
V
CC
to GND 7V
Voltage at VF
X
IV
CC
+ 0.5V to V
BB
0.5V
Voltage at any Digital Input V
CC
+ 0.5V to GND 0.5V
Storage Temperature Range −65˚C to + 150˚C
V
BB
to GND −7V
Current at VF
R
0±100 mA
Current at any Digital Output ±50 mA
Lead Temperature
(Soldering, 10 sec.) 300˚C
Electrical Characteristics
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. All other limits are assured by
correlation with other production tests and/or product design and characterization. All signals referenced to GND. Typicals
specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
DIGITAL INTERFACES
V
IL
Input Low Voltage All Digital Inputs (DC Meas.) (Note 10) 0.7 V
V
IH
Input High Voltage All Digital Inputs (DC Meas.) (Note 10) 2.0 V
V
OL
Output Low Voltage D
X
0, D
X
1, TS
X
0, TS
X
1 and CO, I
L
=3.2 mA, 0.4 V
All Other Digital Outputs, I
L
=1mA
V
OH
Output High Voltage D
X
0, D
X
1 and CO, I
L
=−3.2 mA, 2.4 V
All Other Digital Outputs (except TS
X
), I
L
=−1 mA
All Digital Outputs, I
L
=−100 µA V
CC
0.5 V
I
IL
Input Low Current Any Digital Input, GND <V
IN
<V
IL
−10 10 µA
I
IH
Input High Current Any Digital Input except MR, V
IH
<V
IN
<V
CC
−10 10 µA
MR Only −10 100 µA
I
OZ
Output Current in D
X
0, D
X
1, TS
X
0, TS
X
1, CO and CI/O (as an Output)
High Impedance IL5–IL0 When Selected as Inputs −10 10 µA
State (TRI-STATE) GND <V
OUT
<V
CC
−40˚C to +85˚C (TP3070-X) −30 30 µA
ANALOG INTERFACES
I
VFXI
Input Current, VF
X
I −3.3V <VF
X
I<3.3V −10.0 10.0 µA
R
VFXI
Input Resistance −3.3V <VF
X
I<3.3V 390 620 k
VOS
X
Input Offset Voltage Transmit Gain =0 dB 200 mV
Applied at VF
X
I Transmit Gain =25.4 dB 10 mV
RL
VFRO
Load Resistance Receive Gain =0 dB 15k
Receive Gain =−0.5 dB 600
Receive Gain =−1.2 dB 300
CL
VFRO
Load Capacitance RL
VFRO
300200 pF
CL
VFRO
from VF
R
OtoGND
RO
VFRO
Output Resistance Steady Zero PCM Code Applied to 1.0 3.0
D
R
0orD
R
1
VOS
R
Output Offset Alternating ±Zero PCM Code Applied to −200 200 mV
Voltage at V
FRO
D
R
0orD
R
1, Maximum Receive Gain
POWER DISSIPATION
I
CC
0 Power Down Current CCLK, CI/O, CI, CO, =0.4V, CS =2.4V
Interface Latches Set as Outputs with No Load, 0.1 0.6 mA
All Other Inputs Active, Power Amp Disabled
I
BB
0 Power Down Current As Above −0.1 −0.3 mA
−40˚C to +85˚C (TP3070-X) −0.4 mA
I
CC
1 Power Up Current CCLK, CI/O, CI, CO =0.4V, CS =2.4V
No Load on Power Amp 8.0 11.0 mA
Interface Latches Set as Outputs with No Load
−40˚C to +85˚C (TP3070-X) 13.0 mA
www.national.com11
Electrical Characteristics (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. All other limits are assured by
correlation with other production tests and/or product design and characterization. All signals referenced to GND. Typicals
specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
POWER DISSIPATION
I
BB
1 Power Up Current As Above −8.0 −11.0 mA
−40˚C to +85˚C (TP3070-X) −13.0 mA
I
CC
2 Power Down Current Power Amp Enabled 2.0 3.0 mA
−40˚C to +85˚C (TP3070-X) 4.0 mA
I
BB
2 Power Down Current Power Amp Enabled −2.0 −3.0 mA
−40˚C to +85˚C (TP3070-X) −4.0 mA
Note 9: “Absolute Maximum Ratings” indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for which the device is
functional, but do not guarantee specific performance limits.
Note 10: See definitions and timing conventions section.
Timing Specifications
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%;V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. All other limits are assured by
correlation with other production tests and/or product design and characterization. All signals referenced to GND. Typicals
specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
All timing parameters are measured at V
OH
=2.0V and V
OL
=0.7V.
See Definitions and Timing Conventions section for test methods information.
Symbol Parameter Conditions Min Typ Max Units
MASTER CLOCK TIMING
f
MCLK
Frequency of MCLK Selection of Frequency is 512 kHz
Programmable (See
Table 5
) 1536 kHz
1544 kHz
2048 kHz
4096 kHz
t
WMH
Period of MCLK High Measured from V
IH
to V
IH
(Note 11) 80 ns
t
WML
Period of MCLK Low Measured from V
IL
to V
IL
(Note 11) 80 ns
t
RM
Rise Time of MCLK Measured from V
IL
to V
IH
30 ns
t
FM
Fall Time of MCLK Measured from V
IH
to V
IL
30 ns
t
HBM
HOLD Time, BCLK LOW TP3070 Only 50 ns
to MCLK HIGH
t
WFL
Period of F
SX
or F
SR
Low Measured from V
IL
to V
IL
1 MCLK Period
PCM INTERFACE TIMING
f
BCLK
Frequency of BCLK May Vary from 64 kHz to 4096 kHz 64 4096 kHz
in 8 kHz Increments
t
WBH
Period of BCLK High Measured from V
IH
to V
IH
80 ns
t
WBL
Period of BCLK Low Measured from V
IL
to V
IL
80 ns
t
RB
Rise Time of BCLK Measured from V
IL
to V
IH
30 ns
t
FB
Fall Time of BCLK Measured from V
IH
to V
IL
30 ns
t
HBF
Hold Time, BCLK Low 30 ns
to FS
X/R
High or Low
t
SFB
Setup Time, FS
X/R
30 ns
High to BCLK Low
t
DBD
Delay Time, BCLK High Load =100 pF Plus 2 LSTTL Loads 80 ns
to Data Valid −40˚C to +85˚C (TP3070-X) 90 ns
www.national.com 12
Timing Specifications (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%;V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. All other limits are assured by
correlation with other production tests and/or product design and characterization. All signals referenced to GND. Typicals
specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
All timing parameters are measured at V
OH
=2.0V and V
OL
=0.7V.
See Definitions and Timing Conventions section for test methods information.
Symbol Parameter Conditions Min Typ Max Units
PCM INTERFACE TIMING
t
DBZ
Delay Time, BCLK Low to D
X
0/1 D
X
0/1 Disabled is measured at V
OL
or V
OH
according to
Figure 4
or
Figure 5
Disabled if FS
X
Low, FS
X
Low to
D
X
0/1 disabled if 8th BCLK 15 80 ns
Low, or BCLK High to D
X
0/1
Disabled if FS
X
High −40˚C to +85˚C (TP3070-X) 15 100 ns
t
DBT
Delay Time, BCLK High to TS
X
Low if FS
X
High, or FS
X
High to
TS
X
Low if BCLK High (Non
Delayed Mode); BCLK High to
TS
X
Low (Delayed Data Mode)
Load =100 pF Plus 2 LSTTL Loads 60 ns
t
ZBT
TRI-STATE Time, BCLK Low to
TS
X
High if FS
X
Low, FS
X
Low
to TS
X
High if 8th BCLK Low, or
BCLK High to TS
X
High if FS
X
High
15 60 ns
t
DFD
Delay Time, FS
X/R
Load =100 pF Plus 2 LSTTL Loads,
High to Data Valid Applies if FS
X/R
Rises Later than 80 ns
BCLK Rising Edge in Non-Delayed
Data Mode Only
−40˚C to +85˚C (TP3070-X) 90 ns
t
SDB
Setup Time, D
R
0/1 30 ns
Valid to BCLK Low
t
HBD
Hold Time, BCLK 15 ns
Low to D
R
0/1 Invalid −40˚C to +85˚C (TP3070-X) 15 ns
SERIAL CONTROL PORT TIMING
f
CCLK
Frequency of CCLK 2048 kHz
t
WCH
Period of CCLK High Measured from V
IH
to V
IH
160 ns
t
WCL
Period of CCLK Low Measured from V
IL
to V
IL
160 ns
t
RC
Rise Time of CCLK Measured from V
IL
to V
IH
50 ns
t
FC
Fall Time of CCLK Measured from V
IH
to V
IL
50 ns
t
HCS
Hold Time, CCLK Low CCLK1 10 ns
to CS Low
t
HSC
Hold Time, CCLK CCLK 8 100 ns
Low to CS High
t
SSC
Setup Time, CS 60 ns
Transition to CCLK Low
t
SSCO
Setup Time, CS 50 ns
Transition to CCLK High
t
SDC
Setup Time, CI (CI/O) 50 ns
Data In to CCLK Low
t
HCD
Hold Time, CCLK 50 ns
Low to CI/O Invalid
t
DCD
Delay Time, CCLK High Load =100 pF plus 2 LSTTL Loads 80 ns
to CI/O Data Out Valid −40˚C to +85˚C (TP3070-X) 100 ns
www.national.com13
Timing Specifications (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%;V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. All other limits are assured by
correlation with other production tests and/or product design and characterization. All signals referenced to GND. Typicals
specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
All timing parameters are measured at V
OH
=2.0V and V
OL
=0.7V.
See Definitions and Timing Conventions section for test methods information.
Symbol Parameter Conditions Min Typ Max Units
SERIAL CONTROL PORT TIMING
t
DSD
Delay Time, CS Low Applies Only if Separate 80 ns
to CO (CI/O) Valid CS used for Byte 2
−40˚C to +85˚C (TP3070-X) 100 ns
t
DDZ
Delay Time, CS or 9th CCLK
High to CO (CI/O) High
Impedance
Applies to Earlier of CS High or 9th
CCLK High 15 80 ns
INTERFACE LATCH TIMING
t
SLC
Setup Time, IL to Interface Latch Inputs Only 100 ns
CCLK 8 of Byte 1
t
HCL
Hold Time, IL Valid from 50 ns
8th CCLK Low (Byte 1)
t
DCL
Delay Time CCLK 8 of Interface Latch Outputs Only 200 ns
Byte2toIL C
L
=50 pF
MASTER RESET PIN
t
WMR
Duration of 1 µs
Master Reset High
Note 11: Applies only to MCLK Frequencies 1.536 MHz. At 512 kHz a 50:50 ±2%Duty Cycle must be used.
Timing Diagrams
DS008635-8
FIGURE 4. Non Delayed Data Timing Mode
www.national.com 14
Timing Diagrams (Continued)
DS008635-9
FIGURE 5. Delayed Data Timing Mode
(Time Slot Zero Only)
www.national.com15
Timing Diagrams (Continued)
DS008635-10
FIGURE 6. Control Port Timing
www.national.com 16
Transmission Characteristics
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. f =1015.625 Hz, VF
X
I=
0 dBm0, D
R
0orD
R
1=0 dBm0 PCM code. Transmit and receive gains programmed for maximum 0 dBm0 test levels (0 dB
gain), hybrid balance filter disabled. All other limits are assured by correlation with other production tests and/or product de-
sign and characterization. All signals referenced to GND. Typicals specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
AMPLITUDE RESPONSE
Absolute Levels The Maximum 0 dBm0 Levels are:
VF
X
I 1.619 Vrms
VF
R
O (15 kLoad) 1.964 Vrms
The Minimum 0 dBm0 Levels are:
VF
X
I 87.0 mVrms
VF
R
O (Any Load 300) 105.0 mVrms
Overload Levels are 3.17 dBm0 (µLaw)
and 3.14 dBm0 (A-Law)
G
XA
Transmit Gain Transmit Gain Programmed for Maximum
Absolute Accuracy 0 dBm0 Test Level. (All 1’s in gain register)
Measure Deviation of Digital Code from
Ideal 0 dBm0 PCM Code at D
X
0/1.
T
A
=25˚C −0.15 0.15 dB
G
XAG
Transmit Gain T
A
=25˚C, V
CC
=5V, V
BB
=5V
Variation with Programmed Gain from 0 dB to 19 dB
Programmed Gain (0 dBm0 Levels of 1.619 Vrms to
0.182 Vrms) −0.1 0.1 dB
Programmed Gain from 19.1 dB to 25.4 dB
(0 dBm0 Levels of 0.180 Vrms to
0.087 Vrms) −0.3 0.3 dB
Note: ±0.1 dB min/max is available as a selected
part.
G
XAF
Transmit Gain Relative to 1015.625 Hz, (Note 15)
Variation with Minimum Gain <G
X
<Maximum Gain
Frequency f =60 Hz −26 dB
f=200 Hz −1.8 −0.1 dB
f=300 Hz to 3000 Hz −0.15 0.15 dB
f=3400 Hz −0.7 0.0 dB
f=4000 Hz −14 dB
f4600 Hz. Measure Response −32 dB
at Alias Frequency from 0 kHz to 4 kHz.
G
X
=0 dB, VF
X
I=1.619 Vrms
Relative to 1015.625 Hz
f=62.5 Hz −24.9 dB
f=203.125 Hz −1.7 −0.1 dB
f=343.75 Hz −0.15 0.15 dB
f=515.625 Hz −0.15 0.15 dB
f=2140.625 Hz −0.15 0.15 dB
f=3156.25 Hz −0.15 0.15 dB
f=3406.250 Hz −0.74 0.0 dB
f=3984.375 Hz −13.5 dB
Relative to 1062.5 Hz (Note 15)
f=5250 Hz, Measure 2750 Hz −32 dB
f=11750 Hz, Measure 3750 Hz −32 dB
f=49750 Hz, Measure 1750 Hz −32 dB
www.national.com17
Transmission Characteristics (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. f =1015.625 Hz, VF
X
I=
0 dBm0, D
R
0orD
R
1=0 dBm0 PCM code. Transmit and receive gains programmed for maximum 0 dBm0 test levels (0 dB
gain), hybrid balance filter disabled. All other limits are assured by correlation with other production tests and/or product de-
sign and characterization. All signals referenced to GND. Typicals specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
AMPLITUDE RESPONSE
G
XAT
Transmit Gain Measured Relative to G
XA
,V
CC
=5V,
Variation with V
BB
=−5V, −0.1 0.1 dB
Temperature Minimum gain <G
X
<Maximum Gain
−40˚C to +85˚C (TP3070-X) −0.15 0.15 dB
G
XAL
Transmit Gain Sinusoidal Test Method.
Variation with Signal Reference Level =0 dBm0.
Level VF
X
I=−40 dBm0 to +3 dBm0 −0.2 0.2 dB
VF
X
I=−50 dBm0 to −40 dBm0 −0.4 0.4 dB
VF
X
I=−55 dBm0 to −50 dBm0 −1.2 1.2 dB
G
RA
Receive Gain Receive Gain Programmed for Maximum
Absolute Accuracy 0 dBm0 Test Level (All 1’s in
Gain Register). Apply 0 dBm0 PCM Code
to D
R
0orD
R
1. Measure VF
R
O.
T
A
=25˚C −0.15 0.15 dB
G
RAG
Receive Gain T
A
=25˚C, V
CC
=5V, V
BB
=−5V
Variation with Programmed Gain from 0 dB to 19 dB
Programmed Gain (0 dBm0 Levels of 1.964 Vrms to
0.220 Vrms) −0.1 0.1 dB
Programmed Gain from 19.1 dB to 25.4 dB
(0 dBm0 Levels of 0.218 Vrms to
0.105 Vrms) −0.3 0.3 dB
Note: ±0.1 dB min/max is available as a selected
part.
G
RAT
Receive Gain Measured Relative to G
RA
.
Variation with Temperature V
CC
=5V, V
BB
=−5V. −0.1 0.1 dB
Minimum Gain <G
R
<Maximum Gain
−40˚C to +85˚C (TP3070-X) −0.15 0.15 dB
G
RAF
Receive Gain Relative to 1015.625 Hz, (Note 15)
Variation with Frequency D
R
0orD
R
1=0 dBm0 code.
Minimum Gain <G
R
<Maximum Gain
f=200 Hz −0.25 0.15 dB
f=300 Hz to 3000 Hz −0.15 0.15 dB
f=3400 Hz −0.7 0.0 dB
f=4000 Hz −14 dB
G
R
=0 dB, D
R
0=0 dBm0 Code,
G
X
=0 dB (Note 15)
f=296.875 Hz −0.15 0.15 dB
f=1875.00 Hz −0.15 0.15 dB
f=2906.25 Hz −0.15 0.15 dB
f=2984.375 Hz −0.15 0.15 dB
f=3406.250 Hz −0.74 0.0 dB
f=3984.375 Hz −13.5 dB
www.national.com 18
Transmission Characteristics (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. f =1015.625 Hz, VF
X
I=
0 dBm0, D
R
0orD
R
1=0 dBm0 PCM code. Transmit and receive gains programmed for maximum 0 dBm0 test levels (0 dB
gain), hybrid balance filter disabled. All other limits are assured by correlation with other production tests and/or product de-
sign and characterization. All signals referenced to GND. Typicals specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
AMPLITUDE RESPONSE
G
RAL
Receive Gain Sinusoidal Test Method.
Variation with Signal Reference Level =0 dBm0.
Level D
R
0=−40 dBm0 to +3 dBm0 −0.2 0.2 dB
D
R
0=−50 dBm0 to −40 dBm0 −0.4 0.4 dB
D
R
0=−55 dBm0 to 50 dBm0 −1.2 1.2 dB
D
R
0=3.1 dBm0
R
L
=600,G
R
=−0.5 dB −0.2 0.2 dB
R
L
=300,G
R
=−1.2 dB −0.2 0.2 dB
ENVELOPE DELAY DISTORTION WITH FREQUENCY
D
XA
Tx Delay, Absolute f =1600 Hz 315 µs
D
XR
Tx Delay, Relative to D
XA
f=500–600 Hz 220 µs
f=600–800 Hz 145 µs
f=800–1000 Hz 75 µs
f=1000–1600 Hz 40 µs
f=1600–2600 Hz 75 µs
f=2600–2800 Hz 105 µs
f=2800–3000 Hz 155 µs
D
RA
Rx Delay, Absolute f =1600 Hz 200 µs
D
RR
Rx Delay, Relative to D
RA
f=500–1000 Hz −40 µs
f=1000–1600 Hz −30 µs
f=1600–2600 Hz 90 µs
f=2600–2800 Hz 125 µs
f=2800–3000 Hz 175 µs
NOISE
N
XC
Transmit Noise, C Message (Note 12) 12 15 dBrnC0
Weighted, µ-law Selected All ‘1’s in Gain Register
N
XP
Transmit Noise, P Message (Note 12) −74 −67 dBm0p
Weighted, A-law Selected All ‘1’s in Gain Register
N
RC
Receive Noise, C Message PCM Code is Alternating Positive 8 11 dBrnC0
Weighted, µ-law Selected and Negative Zero
N
RP
Receive Noise, P Message PCM Code Equals Positive Zero −82 −79 dBm0p
Weighted, A-law Selected
N
RS
Noise, Single Frequency f =0 kHz to 100 kHz, Loop Around −53 dBm0
Measurement, VF
X
I=0 Vrms
PPSR
X
Positive Power Supply V
CC
=5.0 V
DC
+ 100 mVrms
Rejection, Transmit f =0 kHz–4 kHz (Note 13) 36 dBC
f=4 kHz–50 kHz 30 dBC
NPSR
X
Negative Power Supply V
BB
=−5.0 V
DC
+ 100 mVrms
Rejection, Transmit f =0 kHz–4 kHz (Note 13) 36 dBC
f=4 kHz–50 kHz 30 dBC
www.national.com19
Transmission Characteristics (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. f =1015.625 Hz, VF
X
I=
0 dBm0, D
R
0orD
R
1=0 dBm0 PCM code. Transmit and receive gains programmed for maximum 0 dBm0 test levels (0 dB
gain), hybrid balance filter disabled. All other limits are assured by correlation with other production tests and/or product de-
sign and characterization. All signals referenced to GND. Typicals specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
NOISE
PPSR
R
Positive Power Supply PCM Code Equals Positive Zero
Rejection, Receive V
CC
=5.0 V
DC
+ 100 mVrms
Measure VF
R
O
f=0 Hz–4000 Hz 36 dBC
f=4 kHz–25 kHz 40 dB
f=25 kHz–50 kHz 36 dB
NPSR
R
Negative Power Supply PCM Code Equals Positive Zero
Rejection, Receive V
BB
=−5.0 V
DC
+ 100 mVrms
Measure VF
R
O
f=0 Hz–4000 Hz 36 dBC
f=4 kHz–25kHz 40 dB
f=25 kHz–50 kHz 36 dB
SOS Spurious Out-of-Band 0 dBm0, 300 Hz to 3400 Hz Input PCM
Signals at the Channel Code Applied at D
R
0 (or D
R
1)
Output 4600 Hz–7600 Hz −30 dB
7600 Hz–8400 Hz −40 dB
8400 Hz–50,000 Hz −30 dB
DISTORTION
STD
X
Signal to Total Distortion Sinusoidal Test Method
STD
R
Transmit or Receive Level =3.0 dBm0 33 dBC
Half-Channel, µ-law Selected =0 dBm0 to 30 dBm0 36 dBC
=−40 dBm0 30 dBC
=−45 dBm0 25 dBC
STD
RL
Signal to Total Distortion Sinusoidal Test Method
Receive with Level =+3.1 dBm0
Resistive Load R
L
=600,G
R
=−0.5 dB 33 dBC
R
L
=300,G
R
=−1.2 dB 33 dBC
SFD
X
Single Frequency −46 dB
Distortion, Transmit
SFD
R
Single Frequency −46 dB
Distortion, Receive
IMD Intermodulation Distortion Transmit or Receive
Two Frequencies in the Range −41 dB
300 Hz–3400 Hz
www.national.com 20
Transmission Characteristics (Continued)
Unless otherwise noted, limits printed in BOLD characters are guaranteed for V
CC
=+5V ±5%,V
BB
=−5V ±5%;T
A
=0˚C to
+70˚C (−40˚C to +85˚C for TP3070-X) by correlation with 100%electrical testing at T
A
=25˚C. f =1015.625 Hz, VF
X
I=
0 dBm0, D
R
0orD
R
1=0 dBm0 PCM code. Transmit and receive gains programmed for maximum 0 dBm0 test levels (0 dB
gain), hybrid balance filter disabled. All other limits are assured by correlation with other production tests and/or product de-
sign and characterization. All signals referenced to GND. Typicals specified at V
CC
=+5V, V
BB
=−5V, T
A
=25˚C.
Symbol Parameter Conditions Min Typ Max Units
CROSSTALK
CT
X-R
Transmit to Receive
Crosstalk, 0 dBm0 Transmit
Level
f=300 Hz–3400 Hz −90 −75 dB
D
R
=Idle Code
CT
R-X
Receive to Transmit
Crosstalk, 0 dBm0 Receive
Level
f=300 Hz–3400 Hz −90 −70 dB
(Note 13)
Note 12: Measured by grounded input at VFXI.
Note 13: PPSRX, NPSRX, and CTR–X are measured with a −50 dBm0 activation signal applied to VFXI.
Note 14: A signal is Valid if it is above VIHor below VIL and Invalid if it is between VIL and VIH. For the purposes of this specification the following conditions apply:
a) All input signals are defined as: VIL =0.4V, VIH =2.7V, tR<10 ns, tF<10 ns.
b) tRis measured from VIL to VIH.t
Fis measured from VIH to VIL.
c) Delay Times are measured from the input signal Valid to the output signal Valid.
d) Setup Times are measured from the data input Valid to the clock input Invalid.
e) Hold Times are measured from the clock signal Valid to the data input Invalid.
f) Pulse widths are measured from VIL to VIL or from VIH to VIH.
Note 15: A multi-tone test technique is used.
www.national.com21
Definitions and Timing Conventions
DEFINITIONS
V
IH
V
IH
is the D.C. input level above which
an input level is guaranteed to appear as
a logical one. This parameter is to be
measured by performing a functional
test at reduced clock speeds and nomi-
nal timing, (i.e., not minimum setup and
hold times or output strobes), with the
high level of all driving signals set to V
IH
and maximum supply voltages applied
to the device.
V
IL
V
IL
is the D.C. input level below which
an input level is guaranteed to appear as
a logical zero to the device. This param-
eter is measured in the same manner as
V
IH
but with all driving signal low levels
set to V
IL
and minimum supply voltages
applied to the device.
V
OH
V
OH
is the minimum D.C. output level to
which an output placed in a logical one
state will converge when loaded at the
maximum specified load current.
V
OL
V
OL
is the maximum D.C. output level to
which an output placed in a logical zero
state will converge when loaded at the
maximum specified load current.
Threshold Region The threshold region is the range of in-
put voltages between V
IL
and V
IH
.
Valid Signal A signal is Valid if it is in one of the valid
logic states. (i.e., above V
IH
or below
V
IL
). In timing specifications, a signal is
deemed valid at the instant it enters a
valid state.
Invalid signal A signal is invalid if it is not in a valid
logic state, i.e., when it is in the thresh-
old region between V
IL
and V
IH
. In timing
specifications, a signal is deemed In-
valid at the instant it enters the threshold
region.
TIMING CONVENTIONS
For the purposes of this timing specification the following
conventions apply.
Input Signals All input signals may be characterized
as: V
L
=0.4V, V
H
=2.4V, t
R
<10 ns, t
F
<
10 ns.
Period The period of the clock signal is desig-
nated as t
Pxx
where
xx
represents the
mnemonic of the clock signal being
specified.
Rise Time Rise times are designated as t
Ryy
, where
yy represents a mnemonic of the signal
whose rise time is being specified. t
Ryy
is
measured from V
IL
to V
IH
.
Fall Time Fall times are designated as t
Fyy
, where
yy represents a mnemonic of the signal
whose fall time is being specified. t
Fyy
is
measured from V
IH
to V
IL
.
Pulse Width High The high pulse width width is designated
as t
WzzH
, where zz represents the mne-
monic of the input or output signal whose
pulse width is being specified. High
pulse widths are measured from V
IH
to
V
IH
.
Pulse Width Low The low pulse width is designated as
t
WzzL
, where zz represents the mne-
monic of the input or output signal whose
pulse width is being specified. Low pulse
widths are measured from V
IL
to V
IL
.
Setup Time Setup times are designated as t
Swwxx
,
where ww represents the mnemonic of
the input signal whose setup time is be-
ing specified relative to a clock or strobe
input represented by mnemonic xx.
Setup times are measured from the ww
Valid to xx Invalid.
Hold Time Hold times are designated as T
Hwwxx
,
where ww represents the mnemonic of
the input signal whose hold time is being
specified relative to a clock or strobe in-
put represented by the mnemonic xx.
Hold times are measured from xx Valid
to ww Invalid.
Delay Time Delay times are designated as
T
Dxxyy
[ IHIL], where xx represents the
mnemonic of the input reference signal
and yy represents the mnemonic of the
output signal whose timing is being
specified relative to xx. The mnemonic
may optionally be terminated by an H or
L to specify the high going or low going
transition of the output signal. Maximum
delay times are measured from xx Valid
to yy Valid. Minimum delay times are
measured from xx Valid to yy Invalid.
This parameter is tested under the load
conditions specified in the Conditions
column of the Timing Specifications sec-
tion of this datasheet.
www.national.com 22
23
Physical Dimensions inches (millimeters) unless otherwise noted
Ceramic Dual-In-Line Package (J)
Order Number TP3071J
NS Package Number J20A
Ceramic Dual-In-Line Package (J)
Order Number TP3070J
NS Package Number J28A
www.national.com 24
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
Molded Dual-In-Line Package (N)
Order Number TP3071N
NS Package Number N20A
www.national.com25
Physical Dimensions inches (millimeters) unless otherwise noted (Continued)
LIFE SUPPORT POLICY
NATIONAL’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DE-
VICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF NATIONAL SEMI-
CONDUCTOR CORPORATION. As used herein:
1. Life support devices or systems are devices or sys-
tems which, (a) are intended for surgical implant into
the body, or (b) support or sustain life, and whose fail-
ure to perform when properly used in accordance
with instructions for use provided in the labeling, can
be reasonably expected to result in a significant injury
to the user.
2. A critical component is any component of a life support
device or system whose failure to perform can be rea-
sonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
National Semiconductor
Corporation
Americas
Tel: 1-800-272-9959
Fax: 1-800-737-7018
Email: support@nsc.com
www.national.com
National Semiconductor
Europe Fax: +49 (0) 1 80-530 85 86
Email: europe.support@nsc.com
Deutsch Tel: +49 (0) 1 80-530 85 85
English Tel: +49 (0) 1 80-532 78 32
Français Tel: +49 (0) 1 80-532 93 58
Italiano Tel: +49 (0) 1 80-534 16 80
National Semiconductor
Asia Pacific Customer
Response Group
Tel: 65-2544466
Fax: 65-2504466
Email: sea.support@nsc.com
National Semiconductor
Japan Ltd.
Tel: 81-3-5639-7560
Fax: 81-3-5639-7507
Plastic Leaded Chip Carrier (V)
Order Number TP3070V or TP3070V-X
NS Package Number V28A
TP3070, TP3071, TP3070-X COMBO II Programmable PCM CODEC/Filter
National does not assume any responsibility for use of any circuitry described, no circuit patent licenses are implied and National reserves the right at any time without notice to change said circuitry and specifications.
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,
and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should
obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are
sold subject to TIs terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TIs standard
warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right,
or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information
published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a
warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual
property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied
by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive
business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional
restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all
express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not
responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably
be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing
such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and
acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products
and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be
provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in
such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic."Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at
the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are
designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated
products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products Applications
Audio www.ti.com/audio Communications and Telecom www.ti.com/communications
Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers
Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps
DLP®Products www.dlp.com Energy and Lighting www.ti.com/energy
DSP dsp.ti.com Industrial www.ti.com/industrial
Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical
Interface interface.ti.com Security www.ti.com/security
Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense
Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive
Microcontrollers microcontroller.ti.com Video and Imaging www.ti.com/video
RFID www.ti-rfid.com
OMAP Mobile Processors www.ti.com/omap
Wireless Connectivity www.ti.com/wirelessconnectivity
TI E2E Community Home Page e2e.ti.com
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright ©2011, Texas Instruments Incorporated
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Texas Instruments:
TP3070V-G TP3070V-G/63SN TP3070V-G/NOPB TP3070V-XG TP3070V-XG/63 TP3070V-XG/63SN TP3070V-
XG/NOPB