Model A-105
DESCRIPTION
Model A-105 gage pressure transducers are manufactured with
a unitized stainless steel diaphragm. The advantage of this type
of design is that a thin diaphragm and heavy sidewalls are made
from one piece of stainless steel. This unitized diaphragm is rug-
ged, but at the same time can be made thin enough to measure
low pressures. Available pressure ranges span from 100 psig
to 15,000 psig. These models can be used in corrosive fluid
environments. Model A-105 has welded electrical connectors
as an integral part of the transducer body and recommended
for applications involving rough handling or where an all-welded
stainless steel transducer is required.
All units have four (4) active bonded strain gages arranged in a
Wheatstone-bridge configuration.
FEATURES
• 100psigto15000psigrange
• Flushmountdesign
• Nodeadvolume
• Miniaturefootprint
• Stainlesssteel
• CEapproved
Flush Diaphragm Pressure Transducer
2Honeywell•SensingandControl
Model A-105
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Pressure ranges 100, 150, 200, 300, 500, 750, 1000,
1500, 2000, 3000, 5000, 7500, 10000,
15000 psig
Accuracy6 0.5 % full scale
Non-linearityandhysteresis ±0.5 % full scale
Non-repeatability ±0.1 % full scale
Output 2 mV/V nominal
Resolution Infinite
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto149°C[-65°Fto300°F]
Temperature, compensated 16°Cto71°C[60°Fto160°F]
Temperature effect, zero 0.01%fullscale/°F
Temperature effect, span 0.02%reading/°F
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Strainedgagetype Bonded foil
Excitation(calibration) 5 Vdc
Excitation(acceptable) Up to 5 Vdc or (Vac)
Insulation resistance 5000 mOhm @ 50 Vdc
Bridge resistance 350 ohm
Shuntcalibrationdata Included
Electricaltermination(std) PTIH-10-6P or equivalent (hermetic)
Mating connector (not incl.) PT06A-10-6Sorequiv.(AA111)
MECHANICAL SPECIFICATIONS
Characteristic Measure
Media Gases, liquids compatible with wetted
parts
Overload, safe 50 % over capacity
Proof pressure 400%(max.25kpsi)
Dead volume Flushdiaphragm
Wetted parts material 17-4 PH stainless steel
Weight 2 oz
Casematerial Stainlesssteel
Installation SeeModel355
RANGE CODES
Range Code Available ranges
BR 100 psi
CJ 150 psi
CL 200 psi
CP 300 psi
CR 500 psi
CT 750 psi
CV 1000 psi
DJ 1500 psi
DL 2000 psi
DN 3000 psi
DR 5000 psi
DT 7500 psi
DV 10000 psi
EJ 15000 psi
OPTION CODES
Range Code Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Pressure ranges 100, 150, 200, 300, 500, 750, 1000, 1500, 2000,
3000, 5000, 7500, 10000, 15000 psig
Temperature
compensation
1a.60°Fto160°F
1b.30°Fto130°F
1c.0°Fto185°F
1d.-20°Fto130°F
1e.-20°Fto200°F
1f.70°Fto250°F
1i.-65°Fto250°F
1g.70°Fto325°F
1h.70°Fto400°F
Internal
ampliers 2u. Unamplified, mV/V output
Pressure ports 5d.7/16-20UNFmale
5p.M12x1.5male
Electrical
termination
6a.BendixPTIH-10-6P(orequivalent)
6pin(max250°F)
6e.Integralcable:Teon(-65°Fto475°F)
6h.Integralcable:Silicone(-65°Fto300°F)
6i.Integralunderwatercable:(max180°F)1
6v.Phoenixconnectoronendofcable
Special
calibration3
9a.10point(5up/5down)
20%increments@70°F3
9b.20point(10up/10down)
10%increments@70°F3
Wetted
diaphragm 10e. Iconel X-750
Shock and
vibration 44a.Shock&vibrationresistance
Honeywell•SensingandControl3
Flush Diaphragm Pressure Transducer
MOUNTING DIMENSIONS AND CHARACTERISTICS TYPICAL SYSTEM DIAGRAM
SPECIAL REQUIREMENTS (CONSULT FACTORY)
Haveaspecialrequirement?Newcasepressure,differentcablelengths,
electricalconnectors,ormaterials?Consultourfactorybycalling+1
614-850-5000(800-848-6564).Customizationiskeytoourtestand
measurementbusiness.Specialoutputs,wiringcodes,andcalibrations
are all standard to us.
Forreferenceonly
WIRING CODES
Connector Connector, unamplied
A(+)excitation
B(+)excitation
C (-)excitation
D(-)excitation
E(-) output
F (+)output
SensingandControl
AutomationandControlSolutions
Honeywell
1985DouglasDriveNorth
GoldenValley,MN55422USA
+1-815-235-6847
www.honeywell.com/sensing
008617-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
Model A-105 Flush Diaphragm Pressure Transducer
Warranty. Honeywell warrants goods of its manufacture as
beingfreeofdefectivematerialsandfaultyworkmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
orderacknowledgementorconsultyourlocalsalesofcefor
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
Specicationsmaychangewithoutnotice.Theinformationwe
supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
FormoreinformationaboutSensingandControlproducts,visit
www.honeywell.com/sensingorcall+1-815-235-6847
Emailinquiriestoinfo.sc@honeywell.com
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stopdevicesorinanyotherapplicationwherefailureof
theproductcouldresultinpersonalinjury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthiscatalogueisfor
referenceonly.DONOTUSEthisdocumentasproduct
installationinformation.
•Completeinstallation,operationandmaintenance
informationisprovidedintheinstructionssuppliedwith
eachproduct.
Failure to comply with these instructions could result in
death or serious injury.
NOTES
1. Notavailablewithoption1c.
2. G=Green;B=Blue;W=White;Bl=Black;Br=Brown;Y=Yellow;
R=Red;O=Orange.Colorspecifyingcableandnumberorletter
specifying connector.
3. Availability varies with range.
4. Nomatingconnectornecessarywithcableoption.
5. Notavailablewithtemperaturesbelow-29°C[-20°F]orabove85
°C[185°F].
6. Accuraciesstatedareexpectedforbest-tstraightlineforaller-
rors,includinglinearity,hysteresis&non-repeatabilitythruzero.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
060-0287-13G 060-0287-15G 060-0287-07G 060-0287-17G