Du line Remote Relay Output Type G 8830 1143 (R) Fieldbus Installationbus * Small sized single relay output * Load: 13 A/250 VAC * Withstands 130A inrush current * Powered via Dupline(R) * Address coding by GAP 1605 Ordering Key Product Description (R) The Dupline decentral receiver has a build-in SPST relay for control of a load of up to 13 A/250 VAC. The module is especially designed for the use in building automation applications where it allows a flexible installation concept featuring a separate power and signal (control) bus. The compact size of the module makes it possible to fit it in a junction box or directly behind a power outlet. G 8830 1143 (R) Type: Dupline Housing Receiver No. of channels Output type Type Selection Ordering no. 1 channel 13 A/250 VAC G 8830 1143 Output Specifications Output Contact ratings (AgSnO2) Resistive load AC 1 Minimum load (recommended) Lifetime Operating frequency Response time 1 SPST relay (micro gap) 13 A/250 VAC 100 mA/12 V see table to the right 60 operations/minute 1 pulse train Relay data VDC Supply Max. current (A) 250 VDC 350 mA 100 VDC 500 mA 50 VDC 1,1 Amp 24 VDC 13 Amp Max. DC load breaking capacity 300 200 resistive load DC voltage (Vdc) 100 50 40 30 20 10 0,1 0,2 0,5 1 2 5 10 20 DC current (A) Relay data VAC Load Typical number of operations 250 V, 12 A, cos =1 1.0 x 105 250 V, 8 A, cos =1 3.5 x 105 250 V, 4 A, cos =1 5.0 x 105 250 V, 3 A, cos =1 7.5 x 105 230 V, 550 W filament lamps Iin 40 Apeak Ioff = 2.5 A 2.0 x 105 230 V, 1000 W filament lamps Iin 71.5 Apeak Ioff = 4.5 A 7.0 x 104 230 V, 900 W fluorescent tubes (25 x 36 W) parallel compensated, 30 F 1.0 x 104 230 V, compressor Iin 21 Apeak Ioff =3.5 A cos = 0.5 1.7 x 105 250 V, 8 A, cos = 0.3 1.0 x 105 Specifications are subject to change without notice (19.10.05) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group 1 Du line G 8830 1143 (R) Fieldbus Supply Specifications Insulation Voltage Supplied by Dupline(R) Normal consumption Charge consumption Live parts - Dupline(R) Enclosure - Live parts Enclosure - Dupline(R) General Specifications Mode of Operation Fail-safe mode The output address and failpolarity may be coded by means of the code programmer GAP 1605, with GAPTHP-CAB cable. 1,1 mA 3,1 mA (for max 1 s after relay state change) Power-on delay Typ. 2 s Power-off delay 1s Power dissipation at max. load 0.7 W In case of interruption of the Dupline(R) connection, the channel will be forced into a specific optional status as either active high or active low. Environment Pollution degree Operation temperature Storage temperature Humidity (non-condensing) Housing Material Dimensions (h x w x d) Installationbus 4 kVAC rms (6 mm) 2 kVAC rms (3 mm) 2 kVAC rms (3 mm) Upon loss of Dupline(R) carrier the output goes to the predefined fail-polarity. 3 (IEC 60664) -20 to +50C (-4 to 122F) -50 to +85C (-58 to 185F) 20 to 80% Noryl GFN 1, black 26 x 39 x 17 mm Wiring Diagrams Dimensions S White Black Out 1 Orange Brown 26 D+ D- 17 39 Wire Connections Bus: Output: Bus wires: Output wires: 2 White = Dupline(R) signal, D+ Black = Dupline(R) negative, DBrown = Relay contact set Orange = Relay contact set 2 x 0,75 mm2, 250 V isolation, single core, 150 mm 2 x 1,5 mm2 , 250 V isolation, single core, 150 mm Accessories Programming cable to GAP 1605 GAP-TPH-CAB Specifications are subject to change without notice (19.10.05) Dupline(R) is a registered trademark. A product of the CARLO GAVAZZI Group