Product Data Sheet 1.8 WATT REGULATED DC/DC CONVERTER PWR60XX DESCRIPTION The PWR60XX Series offers a low-cost alternative for some of the most popular DC/DC converters industry wide. Each model has very low noise and an outstanding MTTF. The superior reliability, excellent filtering, and low cost make it an excellent choice for industry-standard usage. The series includes eleven models (other input and output voltages are available upon request), all set in an encapsulant for excellent thermal dissipation for internal components. The use of surface-mount devices and manufacturing processes combined with the encapsulation process, provides the user a product that is more environmentally rugged. FEATURES Low Cost Low Noise Industry-Standard Package Single and Dual Outputs High Isolation Voltage Option Available Linear Output Regulation Internal Input and Output Filtering Low EMI Transformer Design No External Components Required The PWR60XX has full isolation between input and output to give the designer maximum flexibility in grounding options and polarity configurations. The outputs are protected against shorts to increase the units survivability in harsh environments. Thermal Shutdown Protection MECHANICAL TOP VIEW SIDE VIEW 2.0000.015" (50.800.38) 0.4000.10" (10.16) 0.015.005" (0.38) 1.0000.015" (25.40.38) 0.0400.003" (1.020.08) +VOUT 0.170" Min. (4.32) NOTES: All dimensions are in inches (millimeters). GRID: 0.100 inches (2.54 millimeters) PIN PLACEMENT TOLERANCE: 0.015 +VIN * COM -VIN -VOUT BOTTOM VIEW * Common pins are not present on single output models. Product marked with specific model ordered, date code, job code. MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent chemical resistance, wide operating temperature range, and good electrical properties under high humidity environments. The encapsulant and the outer shell of the unit have UL94V-0 ratings. Lead material is brass with a solder plated surface to allow ease of solderability. Internet: http://www.cdpowerelectronics.com Power Electronics Division, United States 3400 E Britannia Drive, Tucson, Arizona 85706 Phone: 800.547.2537 Fax: 520.770.9369 PWR60XX 6/99 REV D Power Electronics Division, Europe C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland Tel: +353.61.474.133 Fax:+353.61.474.141 Page 1 ELECTRICAL SPECIFICATIONS Specifications typical at TA = +25C, rated input voltage, rated output current unless otherwise specified. NOMINAL INPUT VOLTAGE RATED OUTPUT VOLTAGE (VDC) (VDC) (mA) (mA) (mA) (mAp-p) (%) 5 5 5 12 12 12 15 15 15 24 24 5 12 15 5 12 15 5 12 15 5 15 360 75 60 360 75 60 360 75 60 360 60 70 70 70 30 30 30 25 25 25 13 13 655 570 555 275 240 230 220 190 185 120 120 15 15 15 10 10 10 8 8 8 12 12 55 63 65 55 63 65 55 63 65 62 62 MODEL PWR6000 PWR6004 PWR6005 PWR6006 PWR6010 PWR6011 PWR6012 PWR6016 PWR6017 PWR6018 PWR6023 RATED INPUT CURRENT REFLECTED OUTPUT NO RATED RIPPLE CURRENT LOAD LOAD CURRENT EFFICIENCY ABSOLUTE MAXIMUM RATINGS Output Short-Circuit Duration Outputs to Common .................. Continuous Output to Output ....................... Momentary Output Power ......................................... 2.0W Lead Temperature .............................. +300C (soldering, 10 seconds max) TYPICAL APPLICATIONS NOTE: Other input to output voltages may be available. Please consult factory. COMMON SPECIFICATIONS Specifications typical at TA = +25C, rated input voltage, rated output current unless otherwise specified. PARAMETER INPUT ISOLATION (Standard) Rated Voltage Test Voltage Resistance Capacitance Leakage Current ISOLATION (-HV Option) Rated Voltage Test Voltage Resistance Capacitance Leakage Current OUTPUT Rated Power Voltage Setpoint Accuracy Temperature Coefficient Ripple and Noise REGULATION Line Load GENERAL Switching Frequency Package Weight MTTF per MIL-HDBK-217, RevE TEMPERATURE Specification Operation Storage Page 2 CONDITIONS MIN TYP MAX UNITS PWR6000 PWR6004 PWR6005 PWR6006 PWR6010 PWR6011 PWR6012 PWR6016 PWR6017 PWR6018 PWR6023 4.65 4.65 4.65 10.9 10.9 10.9 13.9 13.9 13.9 21.6 21.6 5.0 5.0 5.0 12.0 12.0 12.0 15.0 15.0 15.0 24 24 5.5 5.5 5.5 13.2 13.2 13.2 16.5 16.5 16.5 26.4 26.4 VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC VDC 5 VDC Vpk G pF Arms 5 VDC Vpk G pF Arms 500 500 10 27 VISO = 240VAC, 60Hz 1000 3000 10 27 VISO = 240VAC, 60Hz ORDERING INFORMATION -25C - TA - +70C Rated Load, Nominal Vin 1.8 BW = DC to 10MHz 0.01 20 45 Watts % %/C mVp-p High Line to Low Line Full Load to No Load 0.2 0.5 1.0 1.0 % % Circuit Stress Method 150 20 930,000 2 -25 -25 -40 +25 kHz g Hr +70 +100 +110 PWR 60XX -HV /H Device Family PWR Indicates DC/DC converter Model Number Selected From Table of Electrical Characteristics High Voltage Option No Designator Indicates Standard Model Screening Option C C C PWR60XX 6/99 REV D TYPICAL PERFORMANCE CURVES TA = +25C, Rated Input Voltage, Rated Output Current unless otherwise noted. PWR60XX 6/99 REV D Page 3 TYPICAL PERFORMANCE CURVES TA = +25C, Rated Input Voltage, Rated Output Current unless otherwise noted. Page 4 PWR60XX 6/99 REV D