65 Series Power Relays 20 - 30 A A range of power relays for switching heavy duty loads (up to 7.5 kVA in AC1) * Top and rear DIN rail mount, top and rear mount flange options * AC or DC coils * 3 mm gap between open contacts on NO (AC coil version), FASTON 250 (6.3 x 0.8 mm) versions * Approvals (according to type): IMQ, CSA, SEMKO, SEV, cUL, VDE WHITE GOODS CONDITIONING COFFEE MACHINES AUTOMATIC GATES IIII I II I I II I VOLTAGE STABILIZERS I III FOOTWEAR MACHINES 87 65 Series Power Relays 20 - 30 A 65.31 C DOUBLE BREAKING FASTON 250 RELAY TYPE 65.31 1 NO + 1 NC (SPDT-NC-NO) 20 A - Flange mount with 3 to 3.5 mm O screws - Tin plated brass connections (6.3 x 0.8 mm) - Standard contact material: Ag CdO Options: TYPE 65.31 - 0300 1 NO (SPST-NO) 30 A - 1.5 + 1.5 mm gap between open contacts - Ordering information: see page 93 36.5 9.5 42 32.2 9.1 14 14 11 9.1 13.1 21 b 65.31 6.4 4 14 22 a 13 11 a b 65.31 - 0300 3.6 88 3.5 7 52 42 3 3.6 3.5 32.2 65 Series Power Relays 20 - 30 A TECHNICAL DATA DIELECTRIC STRENGTH tested at leakage current 10 mA for 1 min at 50 Hz between coil and contacts 2,000 V between open contacts 1,500 V between open contacts NO version 2,500 V between adjacent contacts 2,500 V between frame and live parts 2,000 V SURGE TEST (1.2/50 s) between coil and contacts 2,500 V ISOLATION RESISTANCE 20 * 103 M ISOLATION GROUP C 250 MAXIMUM SWITCHING FREQUENCY - without load 36,000 cycles/h - at rated load 600 cycles/h AMBIENT TEMPERATURE (-40 ... +50)C MECHANICAL LIFE 10 * 106 cycles version AC PROTECTION CATEGORY OF ENCLOSURES IP 40 OPERATE AND RELEASE TIME CO NO 20 ms (including contact bounce) 25 ms (including contact bounce) 20 ms (including contact bounce) -- Option = +75C 30 * 106 cycles version DC - pick-up time (0 to UN) - drop-out time (UN to 0) TYPE OF DUTY DIELECTRIC TEST TYPE OF RELAY continuous 2 all-or-nothing 89 65 Series Power Relays 20 - 30 A CONTACT SPECIFICATIONS 65.31 65.31 NO RATED CURRENT 20 A 30 A MAXIMUM PEAK CURRENT 40 A 50 A 5,000 VA 7,500 VA NOMINAL RATE IN AC1 NOMINAL RATE IN AC15 1,000 VA 1,250 VA RATED VOLTAGE 250 V AC 250 V AC MAXIMUM SWITCHING VOLTAGE 400 V AC 400 V AC see diagram H 65 see diagram H 65 1.1 kW/1.5 HP 1.5 kW/2 HP BREAKING CAPACITY IN DC1 SINGLE PHASE HP MOTOR RATING CONTACT RESISTANCE: - initial 50 m 50 m MINIMUM SWITCHING LOAD 1,000 mW (10 V/10 mA) 1,000 mW (10 V/10 mA) AgCdO AgCdO STANDARD CONTACT MATERIAL F 65 20 MAX SWITCHING CURRENT (A) 5 * 10 CYCLES H 65 30 6 5 * 105 1 10 6 4 2 1 0.4 0.2 0.1 5 * 104 1 3 5 7 KVA B A 0.6 20 100 140 180 VOLTAGE DC (V) LOAD (kVA) Breaking capacity for DC1 load at 600 cycles/h. Load applied to 1 contact. A - types 65.31 - 65.61 B - NO versions Contact life vs AC1 load at 600 cycles/h. 1 - types 65.31 and 65.31-0300; 65.61 and 65.61-0300 K 65 REDUCTION FACTOR K 1 0.8 0.6 0.4 1 0.8 0.6 0.4 COS Load reduction factor vs cos . 90 60 0.2 220 65 Series Power Relays 20 - 30 A COIL SPECIFICATIONS VERSIONS: AC - alternating current 50/60 Hz DC - direct current AC RATED POWER DC 2.2 VA 1.3 W OPERATING RANGE (0.8 ... 1.1) UN (0.8 ... 1.1) UN HOLDING VOLTAGE 0.8 UN 0.6 UN MUST DROP-OUT VOLTAGE 0.2 UN 0.1 UN NOMINAL MAGNETOMOTIVE FORCE THERMAL INSULATION CLASS OF WIRE THERMAL RESISTANCE CONDUCTED DISTURBANCE IMMUNITY 180 A 250 A F (+155C) F (+155C) 41C/W 41C/W BURST (acc. to EN 61000 - 4 - 4) livel 4 (4 kV) SURGE (acc. to EN 61000 - 4 - 5) livel 4 (4 kV) AC VERSION DATA R values relate to +20C. Tolerance of R and I values: 10%. Rated voltage Operating range UN Umin V V U Resistance Nominal coil absorption max R UN 50 Hz I V mA 6 4.8 6.6 12 9.6 13.2 4.6 19 367 183 24 19.2 26.4 80 91.7 48 38.4 52.8 320 45.8 60 48 66 500 110 88 121 1,800 36.7 20 120 96 132 1,940 18.6 230 184 253 7,250 10.4 240 192 264 8,500 9.2 DC VERSION DATA R values relate to +20C. Tolerance of R and I values: 10%. Rated Resistance Nominal coil Operating range voltage absorption UN Umin V V U max R V I mA 6 5.1 6.6 28 214 12 10.2 13.2 110 109 24 20.4 26.4 445 53.9 48 40.8 52.8 1,770 27.1 60 51 66 2,760 21.7 121 9,420 11.7 110 93.5 91 65 Series Power Relays 20 - 30 A COIL SPECIFICATIONS R 65 Umin S 65/1 1 70 TEMPERATURE RISE "t" (C) UN 0.9 0.8 0.7 0.6 60 1.1 UN 50 UN 40 30 0.8 UN 20 10 0.5 0 - 40 -20 0 20 40 60 10 80 AMBIENT TEMPERATURE (C) 20 30 60 min Temperature rise "t " vs applied voltage. DC coils. S 65/2 S 65/3 70 70 60 60 50 1.1 UN 40 UN 30 0.8 UN 20 10 0 TEMPERATURE RISE "t" (C) TEMPERATURE RISE "t" (C) 50 HEATING TIME (min) DC coil min pick-up voltage vs ambient temperature. Umin = pick-up voltage UN = rated voltage 50 1.1 UN 40 UN 30 0.8 UN 20 10 0 10 20 30 40 50 60 min HEATING TIME (min) Temperature rise "t " vs applied voltage. AC 50 Hz coils. 92 40 10 20 30 40 50 60 min HEATING TIME (min) Temperature rise "t " vs applied voltage. AC 60 Hz coils. 65 Series Power Relays 20 - 30 A ORDERING INFORMATION Example: a 65 series power relays with 1 CO contact with a 12 V DC coil. 6 5 Series 3 1 No. of poles 1 = 1 CO 0 1 2 9 Coil version 8 = AC (50/60 Hz) 9 = DC Type 3 = FASTON 250, with rear flange mount Coil rated voltage 6V 006 = 012 = 12 V 024 = 24 V 048 = 48 V 060 = 60 V 110 = 110 V 125 = 125 V 230 = 230 V 0 0 0 0 Contact material and contact circuit 00 = Standard 03 = NO Light and mechanical indicators 00 = Standard 05 = Top flange mount 07 = Top DIN rail mount 08 = Rear DIN rail mount OPTIONS TOP DIN RAIL MOUNT (0007) REAR DIN RAIL MOUNT (0008) 93