TransGlobal(R) TGC Series International Transformer Chassis Mount SPECIFICATIONS: ! WARNING ELECTROCUTION HAZARD Disconnect electric power to system at main fuse or circuit breaker box before servicing. Failure to do so could result in death or serious injury. INPUT: OUTPUT: INSULATION RATING: DIELECTRIC STRENGTH: AGENCY APPROVALS: FIRE HAZARD Do not exceed transformer ratings. Higher voltage may damage control and could cause personal injury or property damage. 115/230 VAC, 50/60 Hz See Table Class B (130 C) 4,000 VRMS UL recognized component for use in the US and Canada TUV certified to EN61558 FILE NOs.: Designed to requirements of EN60950 UL File # E173993 TUV Report # DI 401341 NOTES: 1. Designed for single input and single output use only and requires simultaneous use of all windings. STANCOR PART NUMBER Agency Certif. STANCOR PART NUMBER VA VA TGC25-10 25 10.0 C.T. @ 2.50 TGC43-10 43 10.0 C.T. @ 4.30 5.0 @ 5.00 TGC25-24 25 24.0 C.T. @ 1.00 12.0 @ 2.00 5.0 @ 8.60 TGC43-24 43 24.0 C.T. @ 1.80 12.0 @ 3.60 TGC80-10 80 10.0 C.T. @ 8.00 5.0 @ 16.00 TGC80-24 80 24.0 C.T. @ 3.30 12.0 @ 6.60 TGC130-10 130 10.0 C.T. @ 13.00 5.0 @ 26.00 TGC130-24 130 24.0 C.T. @ 5.40 12.0 @ 10.80 TGC175-10 175 10.0 C.T. @ 17.50 5.0 @ 35.00 TGC175-24 175 24.0 C.T. @ 7.30 12.0 @ 14.60 TGC25-12 25 12.6 C.T. @ 2.00 6.3 @ 4.00 TGC25-28 25 28.0 C.T. @ 0.90 14.0 @ 1.80 TGC43-12 43 12.6 C.T. @ 3.40 6.3 @ 6.80 TGC43-28 43 28.0 C.T. @ 1.50 14.0 @ 3.00 TGC80-12 80 12.6 C.T. @ 6.30 6.3 @ 12.60 TGC80-28 80 28.0 C.T. @ 2.80 14.0 @ 5.60 TGC130-12 130 12.6 C.T. @ 10.30 6.3 @ 20.60 TGC130-28 130 28.0 C.T. @ 4.60 14.0 @ 9.20 TGC175-12 175 12.6 C.T. @ 14.00 6.3 @ 28.00 TGC175-28 175 28.0 C.T. @ 6.25 14.0 @ 12.50 TGC25-16 25 16.0 C.T. @ 1.60 8.0 @ 3.20 TGC25-36 25 36.0 C.T. @ 0.70 18.0 @ 1.40 TGC43-16 43 16.0 C.T. @ 2.70 8.0 @ 5.40 TGC43-36 43 36.0 C.T. @ 1.20 18.0 @ 2.40 TGC80-16 80 16.0 C.T. @ 5.00 8.0 @ 10.00 TGC80-36 80 36.0 C.T. @ 2.20 18.0 @ 4.40 TGC130-16 130 16.0 C.T. @ 8.10 8.0 @ 16.20 TGC130-36 130 36.0 C.T. @ 3.60 18.0 @ 7.20 TGC175-16 175 16.0 C.T. @ 11.00 8.0 @ 22.00 TGC175-36 175 36.0 C.T. @ 4.80 18.0 @ 9.60 TGC25-20 25 20.0 C.T. @ 1.25 10.0 @ 2.50 TGC25-230 25 230.0 C.T. @ 0.11 115.0 @ 0.22 TGC43-20 43 20.0 C.T. @ 2.20 10.0 @ 4.40 TGC43-230 43 230.0 C.T. @ 0.19 115.0 @ 0.38 TGC80-20 80 20.0 C.T. @ 4.00 10.0 @ 8.00 TGC80-230 80 230.0 C.T. @ 0.35 115.0 @ 0.70 TGC130-20 130 20.0 C.T. @ 6.50 10.0 @ 13.00 TGC130-230 130 230.0 C.T. @ 0.57 115.0 @ 1.14 TGC175-20 175 20.0 C.T. @ 8.80 10.0 @ 17.60 TGC175-230 175 230.0 C.T. @ 0.76 115.0 @ 1.52 Agency Certification : Secondary RMS Rating Series Parallel Volts Amps Volts Amps 2. The input to the transformer must be fused with an IEC 60127-2 Standard Sheet 3 Time lag (surge-proof) Low-breaking capacity or Standard Sheet 6 Time lag (surge-proof) Enhanced breaking capacity fuse. The fuse value are shown in the Dimensions and Requirements Table Secondary RMS Rating Series Parallel Volts Amps Volts Amps Agency Certif. PART NO. 37-6608B www.stancor.com Replaces 37-6608A 0837 TGC Series Dimensions and Requirements DIMENSIONS-INCHES INPUT FUSE Weight (lbs.) VA Style H W D MW MD C Q.C. Mounting Slots Series Parallel 25 S 2.38 2.81 1.94 2.38 - 0.31 .187 0.156 x 0.250 1.3 0.16A 0.315A 43 S 2.75 3.25 1.94 2.81 - 0.31 .187 0.187 x 0.281 1.8 0.315A 0.63A 80 NV 3.00 2.50 2.38 2.00 2.19 0.31 .187 0.218 x 0.312 2.9 0.5A 1.0A 130 NV 3.38 2.81 2.88 2.25 2.50 0.38 .250 0.218 x 0.312 4.5 1.0A 2.0A 175 NV 3.75 3.13 2.88 2.50 2.50 0.38 .250 0.187 x 0.375 5.6 1.25A 2.5A Label "A" on this surface Label "A" on this surface D D C C H quick connect or solder terminals quick connect or solder terminals Mtg. Slots (4) H MW W MW MD Term 1 ref. Mtg Slots (2) W Term 1 ref. Style S Style NV Primary: 115/230 V, 50/60 Hz Line For 230 V: connect 2 & 5 For 115 V: connect 1 & 5, 2 & 6 Line 1 7 2 8 5 11 6 12 Schematic Diagram Load Series: connect 8 & 11 Parallel: connect 7 & 11, 8 & 12 Load 12 TGCXX-XX 6 11 PRI: 115/230V 50/60Hz 5 SEC: SERIES: XX.XVCT X.XA 8 PARALLEL: X.XV X.XA 7 CHINA 2 1 PA41-XX-XX Label "A" Detail