TDK-Lambda
ZWQ130/L
SPECIFICATIONS (CONVECTION COOLING)
A191-01-01/L-D
MODEL ZWQ130-5223/L ZWQ130-5225/L
ITEMS V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +3.3 +5 +12 -12 +5
2 Minimum Output Current (Convection) (*1) A 1.5 0 0 0 1.5 0 0 0
3
Minimum Output Current (Peak Application)
(*1) A 2.1 0 0 0 2.1 0 0 0
4 Maximum Output Current A 15.0 4.0 4.0 10.0 15.0 4.0 4.0 10.0
5 Total Allowable Output Power (*2) W 130
6 Maximum Peak Output Current (*3) A 19.0 5.0 5.0 12.0 19.0 5.0 5.0 12.0
7 Total Allowable Peak Output Power (*2) W 149.6 170
8 Efficiency (Typ) (*4) % 72
9 Input Voltage Range (*5) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
10 Input Current (100/200VAC) (Typ) (*4) A 2.0/1.0
11 Inrush Current (Typ) (*6) - 14A at 100VAC, 28A at 200VAC, Ta=25oC, Cold Start
12 PFHC - Designed to meet IEC61000-3-2
13 Power Factor (100/200VAC) (Typ) (*4) - 0.99 / 0.93
14 Output Voltage Range V 5.0-5.25 +12/+15 -12/-15 2.0-3.63 5.0-5.25 +12/+15 -12/-15 2.0-5.25
15 Output Voltage Accuracy - - ±5% ±5% - - ±5% ±5% -
mV 120 150 150 120 120 150 150 120
mV 160 180 180 160 160 180 180 160
17 Maximum Line Regulation (*7,8) mV 20 48 48 20 20 48 48 20
18 Maximum Load Regulation (*7,9) mV 100 300 300 100 100 300 300 100
19 Temperature Coefficient - Less than 0.02% /oC
20 Over Current Protection (*10) More than 152W of Total Output Power More than 173W of Total Output Power
21 Over Voltage Protection (*11) V 5.7 - 7.0 16.5 - 22.5 -22.5 - -16.5 3.79 - 4.95 5.7 - 7.0 16.5 - 22.5 -22.5 - -16.5 5.7 - 7.0
22 Hold-Up Time (Typ) (*12) - 20 ms
23 Leakage Current (*13) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
24 Remote ON/OFF Control (*14) Possible
25 Parallel Operation - -
26 Series Operation - -
27 Operating Temperature (*15) - -10 - +60oC (-10 - +40oC : 100%, +60oC : 50%)
28 Operating Humidity - 30 - 90%RH (No Dewdrop)
29 Storage Temperature - -30 - +85oC
30 Storage Humidity - 10 - 95%RH (No Dewdrop)
31 Cooling - Convection Cooling
Withstand Voltage Input - FG : 2kVAC(20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC(100mA), for 1min.
33 Isolation Resistance - More than 100MW at 25oC and 70%RH Output - FG : 500VDC
Vibration - At no operating, 10-55Hz (Sweep for 1min)
19.6 m/s2 Constant, X, Y, Z 1h each.
35 Shock (In package) - Less than 196.1 m/s2
Safety (*16) - Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Designed to meet DENAN
37 EMI - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
38 Immunity (*17) - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11
39 Weight (Typ) - 950g
40 Size (WxHxD) mm 108 x 38 x 250 (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. For V2, V3,V4 stability, require minimum output current of V1.
*10.
Constant current limit with automatic recovery. Refer to test data (A191-53-01_).
*2. Allowable output power is changed according to V4 voltage Not operate at over load or dead short condition for more than 30 seconds.
refer to derating table (A191-01-05/L-_).
*11.
OVP circuit will shut down all outputs, manual reset (Line recycle).
*3. Operating period at peak current is less than 10sec. (Duty<0.35)
*12.
At 100/200VAC, nominal output voltage and total allowable output power.
*4. At 100/200VAC, Ta=25oC and total allowable output power.
*13.
Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC.
*5. For cases where conformance to various safety specs (UL, CSA, EN) are required,
*14.
For using, refer to note (A191-01-07_).
to be described as 100 - 240VAC(50/60Hz).
*15.
At standard mounting.
*6. Not applicable for the inrush current to Noise Filter for less than 0.2ms. - Load (%) is percent of total allowable output power or
*7. Refer to output measuring (A191-01-07_) for line & load regulation each maximum output current, whichever is greater.
and ripple voltage. For other mountings, refer to derating curve (A191-01-05/L-_).
*8. 85 - 265VAC , constant load.
*16.
As for DENAN, designed to meet at 100VAC.
*9. Minimum load - Full load, constant input voltage.
*17.
Refer to test data(A191-58-01_).
0oC <Ta< +60oC
-10oC <Ta< 0oC
Maximum Ripple & Noise (*7)
36
16
32
34
DENSEI-LAMBDA
Z
W
Q
130/L SPECIFICATIONS
FORCED AIR COOLING
A191-01-02/L-D
MODEL ZWQ130-5223/L ZWQ130-5225/L
ITEMS V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +3.3 +5 +12 -12 +5
2 Minimum Output Current (*1) A 2.1 0 0 0 2.1 0 0 0
3 Maximum Output Current A 19.0 5.0 5.0 12.0 19.0 5.0 5.0 12.0
4 Total Allowable Output Power (*2) W 149.6 170
5 Input Current (100/200VAC) (Typ) (*3) A 2.6/1.3
6 Operating Temperature (*4) - -10 ~ +70oC
(
-10 ~+50oC : 100%, +70oC : 50%
)
7 Cooling (*5) - Forced Air Cooling
=NOTES=
*For other items, refer to convection cooling specifications (A191-01-01/L-_).
*1. For V2, V3,V4 stability, require minimum output current of V1.
When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling.
*2. Allowable output power is changed according to V4 voltage, refer to derating table (A191-01-06/L-_).
*3. At 100/200VAC, Ta=25oC total allowable out
p
ut
p
ower
*4. At standard mounting.
- Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
For other mountings, refer to derating curve (A191-01-06/L-_).
*5. Air flow > 0.85m3/min
(
30cfm
)
*Read instruction manual carefully, before using the power supply u
n
TDK-Lambda
ZWQ130/L
SPECIFICATIONS (CONVECTION COOLING)
A191-01-03/L-C
MODEL ZWQ130-5222/L ZWQ130-5224/L
ITEMS V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +12 +5 +12 -12 +24
2
Minimum Output Current (Convection)
(*1) A 1.5 0 0 0 1.5 0 0 0
3
Minimum Output Current (Peak Application)
(*1) A 2.1 0 0 0 2.1 0 0 0
4 Maximum Output Current A 15.0 4.0 4.0 4.0 15.0 4.0 4.0 2.0
5 Total Allowable Output Power W 130
6 Maximum Peak Output Current (*2) A 19.0 5.0 5.0 5.0 19.0 5.0 5.0 2.5
7 Total Allowable Peak Output Power W 170
8 Efficiency (Typ) (*3) % 72
9 Input Voltage Range (*4) - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
10 Input Current (100/200VAC) (Typ) (*3) A 2.0 / 1.0
11 Inrush Current (Typ) (*5) - 14A at 100VAC, 28A at 200VAC, Ta=25°C, Cold Start.
12 PFHC - Designed to meet IEC61000-3-2
13 Power Factor (100/200VAC) (Typ) (*3) - 0.99 / 0.93
14 Output Voltage Range - 5.0-5.25 +12/+15 -12/-15 11.4-12.6 5.0-5.25 +12/+15 -12/-15 22.8-25.2
15 Output Voltage Accuracy - - ±5% ±5% - - ±5% ±5% -
mV 120 150 150 150 120 150 150 200
mV 160 180 180 180 160 180 180 200
17 Maximum Line Regulation (*6,7) mV 20 48 48 48 20 48 48 96
18 Maximum Load Regulation (*6,8) mV 100 300 300 300 100 300 300 400
19 Temperature Coefficient - Less than 0.02% / °C
20 Over Current Protection (*9) More than 173W of Total Output Power
21 Over Voltage Protection (*10) V 5.7 - 7.0 16.5 - 22.5 -22.5 - -16.5 13.8 - 16.2 5.7 - 7.0 16.5 - 22.5 -22.5 - -16.5 27.6 - 32.4
22 Hold-Up Time (Typ) (*11) - 20 ms
23 Leakage Current (*12) - 0.75mA MAX,0.2mA(Typ) at 100VAC / 0.44mA(Typ) at 230VAC
24 Remote ON/OFF Control (*13) Possible
25 Parallel Operation - -
26 Series Operation - -
27 Operating Temperature (*14) - -10 - +60°C (-10 - +40°C :100%, +60°C :50%)
28 Operating Humidity - 30 - 90%RH (No Dewdrop)
29 Storage Temperature - -30 - +85°C
30 Storage Humidity - 10 - 95%RH (No Dewdrop)
31 Cooling - Convection Cooling
Input - FG:2kVAC(20mA), Input - Output:3kVAC (20mA)
Output - FG:500VAC(100mA), for 1min.
33 Isolation Resistance - More than 100MW at 25°C and 70%RH Output - FG:500VDC
- At no operating, 10-55Hz (Sweep for 1min)
19.6 m/s2 Constant, X, Y, Z 1h each.
35 Shock (In package) - Less than 196.1 m/s2
- Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Designed to meet DENAN
37 EMI - Designed to meet EN55011/EN55022-B, FCC-ClassB, VCCI-B
38 Immunity (*16) - Designed to meet EN61000-4-2, -3, -4, -5, -6, -8, -11
39 Weight (Typ) - 950g
40 Size (WxHxD) mm 108 x 38 x 250 (Refer to Outline Drawing)
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*1. For V2, V3,V4 stability, require minimum output current of V1. *9. Constant current limit with automatic recovery. Refer to test data (A191-53-01_).
*2. Operating period at peak current is less than 10sec. (Duty<0.35) Not operate at over load or dead short condition for more than 30 seconds.
*3. At 100/200VAC, Ta=25oC and total allowable output power.
*10.
OVP circuit will shut down all outputs, manual reset (Line recycle).
*4.
For cases where conformance to various safety specs (UL, CSA, EN) are required,
*11.
At 100/200VAC, nominal output voltage and total allowable output power.
to be described as 100 - 240VAC(50/60Hz).
*12.
Measured by the each method of UL, CSA, EN and DENAN (at 60Hz), Ta=25oC.
*5. Not applicable for the inrush current to Noise Filter for less than 0.2ms.
*13.
For using, refer to note (A191-01-07_).
*6. Refer to output measuring (A191-01-07_) for line & load regulation
*14.
At standard mounting.
and ripple voltage. - Load (%) is percent of total allowable output power or
*7. 85 - 265VAC , constant load. each maximum output current, whichever is greater.
*8. Minimum load - Full load, constant input voltage. For other mountings, refer to derating curve (A191-01-05/L-_).
*15.
As for DENAN, designed to meet at 100VAC.
*16.
Refer to test data(A191-58-01_).
36
Withstand Voltage
Vibration
Safety (*15)
32
34
16 0oC <Ta< +60oC
-10oC <Ta< 0oC
Maximum Ripple & Noise (*6)
DENSEI-LAMBDA
ZWQ130/L SPECIFICATIONS (FORCED AIR COOLING)
A191-01-04/L-C
MODEL ZWQ130-5222/L ZWQ130-5224/L
ITEMS V1 V2 V3 V4 V1 V2 V3 V4
1 Nominal Output Voltage V +5 +12 -12 +12 +5 +12 -12 +24
2 Minimum Output Current (*1) A 2.1 0 0 0 2.1 0 0 0
3 Maximum Output Current A 19.0 5.0 5.0 5.0 19.0 5.0 5.0 2.5
4 Total Allowable Output Power W 170
5 Input Current (100/200VAC) (Typ) (*2) A 2.6/1.3
6 Operating Temperature (*3) - -10 ~ +70oC
(
-10 ~+50oC : 100%, +70oC : 50%
)
7 Cooling (*4) - Forced Air Cooling
*Read instruction manual carefully, before using the power supply unit.
=NOTES=
*For other items, refer to convection cooling specifications (A191-01-01/L-_).
*1. For V2, V3,V4 stability, require minimum output current of V1.
When it is using under condition of forced air cooling, V1 minimum output current is same as convection cooling.
*2. At 100/200VAC, Ta=25oC total allowable output power.
*3. At standard mounting.
- Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
For other mountings, refer to derating curve (A191-01-06/L-_).
*4. Air flow > 0.85m3/min(30cfm)
DENSEI-LAMBDA
ZWQ130/L
OUTPUT DERATING
(
CONVECTION COOLING
)
A191-01-05/L
Allowable output power
5225/L 5223/L
Ta
(
oC
)
ABC ABC
-10 ~+25 5V 170W 130W 3.3V 149.6W 130W
30 3V 146W 130W 3V 146W 130W
35 2V 134W 130W 2V 134W 130W
40
45 A : V4 setting voltage
50 B : Total Allowable Peak Output Power
55 C : Total Allowable Output Power
60 * The period of peak current at Convection Cooling
is limited less than 10sec. (Duty < 0.35)
For peak current application, refer to note
(A191-01-07_).
* Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
100 87
LOAD (%)
MOUNTING A MOUNTING B,C,D MOUNTING E
100 100 100
100
50
87
75
6287
75
100
100 75
62
62 50 50
MOUNTING
B
MOUNTING
C
PROHIBI
T
OUTPUT DERATING CURVE FOR CONVECTION COOLING
0
20
40
60
80
100
-100 10203040506070
Ta (°C)
LOAD (%)
MOUNTING A
MOUNTING B,C,D
MOUNTING E
Please refer to Instruction manual.
MOUNTING
A
(STANDARD MOUNTING) ×
MOUNTING
E
MOUNTING
D
DENSEI-LAMBDA
Z
W
Q
130/L
OUTPUT DERATING
(
FORCED AIR COOLING
)
A191-01-06/L
Allowable output power
5225/L 5223/L
Ta
(
oC
)
AA
-10 ~+40 100 5V 3.3V
45 100 3V 3V
50 100 2V 2V
55 87
60 75 A : V4 setting voltage
65 62 B : Total Allowable Output Power
70 50 * Air flow > 0.85m3/min(30cfm)
Air must flow throu
g
h com
p
onent side.
* Load (%) is percent of total allowable output power or each maximum output current, whichever is greater.
LOAD (%)
MOUNTING A,B,C,D,E
146W
B
170W
146W
134W 134W
B
149.6W
MOUNTING
B
MOUNTING
C
MOUNTING
D
PROHIBI
T
OUTPUT DERATING CURVE FOR FORCED AIR COOLING
0
20
40
60
80
100
-100 1020304050607080
Ta (oC)
LOAD (%)
MOUNTING A,B,C,D,E
Please refer to Instruction manual.
MOUNTING
A
(
STANDARD MOUNTING
)
×
MOUNTING
E
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TDK-Lambda:
ZWQ1305225/L