Standard Proximity Sensor
E2E Additions to the Series
Standard Sensors for Detecting
Ferrous Metals under Standard
Conditions
Wide array of variations. Ideal for a variety of applications.
Lineup includes models with pre-wired connectors that use
highly oil-resistant cables
Lineup includes models with 3-mm diameter and sensing
distance of 0.6 mm
Cable protector provided as a standard feature.
Sensing surface made from material that resists cutting
oil for superior environment resistance.
Be sure to read Safety Precautions on
page 22.
Cylindrical Proximity Sensor Selection Guide
1.50.6 0.8 1.0 2 3 4 5 7 8 10 14 18 20
M30
M18
M8
M5
5.4 dia.
4 dia.
3 dia.
M12
M30
M18
M12
M8
Size
Diameter Sensing distance
Determine the
size based on
the installation
space.
The sensing distance depends on
the diameter, shielding, and type
of power supply.
Shield-
ing Diameter Power supply Sensing distance (mm)
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
DC 3-wire
DC 3-wire
DC 3-wire
DC 3-wire
AC 2-wire
DC 2-wire
AC/DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
AC/DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
AC/DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
DC 3-wire
AC 2-wire
DC 2-wire
Shielded
Unshielded
Resists the influence of surrounding
metal
Long sensing distance
1
E2E
No
Yes
Power/Output
Environment
Maintenance
Reducing troubles Higher oil resistance
Easy replacement
Reducing stocked
models
Wide operating
temperature range
Resists the influence of surrounding metal
AC/DC
Mutual interference
prevention
Miswiring measures
Early discovery
of problems
AC
DC DC 2-wire
power? DC 2-Wire Models
E2E-X@D@
DC 3-Wire Models
E2E-X@E@
AC 2-Wire Models
E2E-X@Y@
AC/DC 2-Wire Models
E2E-X@T1
AC/DC 2-Wire Models
E2E-X@T1
Connector Models
E2E-X@D@-M1(G)
E2E-X@E@-M1
E2E-X@Y@-M1
Pre-wired Connector
Models
E2E-X@D1-M1(G)J(-T)
Smartclick Pre-wired
Connector Models
E2E-X@D@-M1TGJ-U
Models with Highly
Oil-resistant Cables
E2E-X@D@-U
Models with a different
frequency (NO Models
only)
E2E-X@@15
DC 2-Wire Models
E2E-X@D@
DC 3-Wire Models
E2E-X@E@
DC 2-Wire
No-polarity Models
E2E-X@D1-M1J-T
Diagnostic Models
E2E-X@D1S
40 to 85°C
E2E-X@E@
E2E-X@Y@
25 to 70°C
E2E-X@D@
E2E-X@T1
Shielded Models
DC 2-Wire Models
E2E-X@D@
NPN/PNP output
AC/DC
Load short-circuit
protection
No polarity
*Check interface
conditions for load.
Mounting to moving
parts Robotics Cable Models
E2E-X@D1-R
E2E-X@E1-R
Robotics cable
PUR (polyurethane) cable
Note: Ask your OMRON sales representative for detail on Long Body Models, Transmission Couplers, and Power Couplers.
2
E2E
Features
Proximity Sensors with Highly Oil-resistant Cables added to the lineup with the E2E-@-U
Models with Smartclick pre-wired connectors added to the E2E-@-U Series
Ordering Information
Sensors
Higher Oil Resistance, DC 2-Wire, Pre-wired Models
Higher Oil Resistance, DC 2-Wire, M12 Smartclick Pre-wired Models
Additions to the Series
Oil Resistance
Oil Resistance
Cable Flexibility
Cable Flexibility
Cable Flexibility
Cable Flexibility at
Cable Flexibility at
Low Temperatures
Low Temperatures
Oil Resistance (Insulation service life):
twice or three times
that of oil-resistant vinyl chloride
Cable Flexibility:
approximately twice
that of cinyl chloride cables
More Flexibility at -40°C
Oil Resistance
Cable Flexibility at
Low Temperatures
XS5 Smartclick connectors used to
enable checking connector mating
Jacket: Polyester elastomer
Insulation: Oil-resistant grade PUR (polyurethane)
Differentiation from standard models:
Orange Head * The dimensions are the same as for standard models.
Appearance Sensing distance Model
NO NC
M8 E2E-X2D1-U E2E-X2D2-U
M12 E2E-X3D1-U E2E-X3D2-U
M18 E2E-X7D1-U E2E-X7D2-U
M30 E2E-X10D1-U E2E-X10D2-U
Shielded
2 mm
3 mm
7 mm
10 mm
Appearance Sensing distance Model
NO NC
M8 E2E-X2D1-M1TGJ-U E2E-X2D2-M1TGJ-U
M12 E2E-X3D1-M1TGJ-U E2E-X3D2-M1TGJ-U
M18 E2E-X7D1-M1TGJ-U E2E-X7D2-M1TGJ-U
M30 E2E-X10D1-M1TGJ-U E2E-X10D2-M1TGJ-U
Shielded
2 mm
3 mm
7 mm
10 mm
3
E2E
DC 2-Wire, Pre-wired Models (Models with self-diagnostic function are 3-wire.)
*1. Models with different frequencies are also available. The model numbers are E2E-X @D15 (example: E2E-X3D15-N).
*2. Models with robotics cables are also available. Add "-R" to the end of the model number (example: E2E-X4MD1-R).
The model number E2E-X2D1-N, however, becomes E2E-X2D1-R.
*3. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X3D1-N 5M).
DC 2-Wire, Connector Models (Models with self-diagnostic function are 3-wire.)
*1. Models with different frequencies are also available. The model numbers are E2E-X@D15-M1G (example: E2E-X3D15-M1G).
*2. Refer to page 19 for details.
Self-diagnostic
output Appearance Sensing distance Model
NO NC
Yes
M12 E2E-X3D1S *1---
M18 E2E-X7D1S *1---
M30 E2E-X10D1S *1---
M12 E2E-X8MD1S *1---
M18 E2E-X14MD1S *1---
M30 E2E-X20MD1S *1---
None
M8 E2E-X2D1-N *2*3 E2E-X2D2-N *3
M12 E2E-X3D1-N *1*2*3 E2E-X3D2-N *3
M18 E2E-X7D1-N *1*2*3 E2E-X7D2-N *3
M30 E2E-X10D1-N *1*2*3E2E-X10D2-N
M8 E2E-X4MD1 *2*3E2E-X4MD2
M12 E2E-X8MD1 *1*2*3E2E-X8MD2
M18 E2E-X14MD1 *1*2*3 E2E-X14MD2
M30 E2E-X20MD1 *1*2*3 E2E-X20MD2
Con-
nector
Self-diag-
nostic
output
Appearance Sensing distance
Model
NO
Applicable
connector
code *2
NC
Applicable
connector
code *2
M12
Yes
M12 E2E-X3D1S-M1 D --- ---
M18 E2E-X7D1S-M1 D --- ---
M30 E2E-X10D1S-M1 D --- ---
M12 E2E-X8MD1S-M1 D --- ---
M18 E2E-X14MD1S-M1 D --- ---
M30 E2E-X20MD1S-M1 D --- ---
None
M8 E2E-X2D1-M1G AE2E-X2D2-M1G D
M12 E2E-X3D1-M1G *1AE2E-X3D2-M1G D
M18 E2E-X7D1-M1G *1AE2E-X7D2-M1G D
M30 E2E-X10D1-M1G *1AE2E-X10D2-M1G D
M8 E2E-X4MD1-M1G AE2E-X4MD2-M1G D
M12 E2E-X8MD1-M1G *1AE2E-X8MD2-M1G D
M18 E2E-X14MD1-M1G *1AE2E-X14MD2-M1G D
M30 E2E-X20MD1-M1G *1AE2E-X20MD2-M1G D
M8 M8
E2E-X2D1-M3G GE2E-X2D2-M3G G
E2E-X4MD1-M3G GE2E-X4MD2-M3G G
Shielded 3 mm
7 mm
10 mm
Unshielded 8 mm
14 mm
20 mm
Shielded
2 mm
3 mm
7 mm
10 mm
Unshielded
4 mm
8 mm
14 mm
20 mm
Shielded 3 mm
7 mm
10 mm
Unshielded 8 mm
14 mm
20 mm
Shielded
2 mm
3 mm
7 mm
10 mm
Unshielded
4 mm
8 mm
14 mm
20 mm
Shielded
2 mm
Unshielded
4 mm
4
E2E
DC 2-Wire, Pre-wired Connector Models
Note: 1. A model with no polarity has a residual voltage of 5 V, which must be taken into consideration together with the interface conditions (the PLC’s ON voltage, for
example) when connecting the Proximity Sensor to a load. Refer to page 19 for details.
2. The standard cable length is 300 mm. Models are also available with 500 mm and 1 m cables.
* Refer to page 19 for details.
Connector Pin Assignments of DC 2-Wire Models
The connector pin assignments of each New E2E DC 2-Wire Model
conform to IEC 947-5-2 Table III. (Only DC 2-Wire Models have
been changed in comparison to the previous models.)
The following models with conventional connector pin assignments
are available as well. (Only NO Models can be used.)
The cable at the right should also be used if the XW3A-P@45-G11
Connector Junction Box is already being used.
Models with conventional connector pin assignments are available as well.
Note: Refer to page 19 for details.
Appearance Sensing distance Operate
Mode
Model
Polarity: Yes Applicable
connector code *Polarity: None Applicable
connector code *
M12
NO
E2E-X3D1-M1GJ AE2E-X3D1-M1J-T B
M18 E2E-X7D1-M1GJ AE2E-X7D1-M1J-T B
M30 E2E-X10D1-M1GJ AE2E-X10D1-M1J-T B
M12 E2E-X8MD1-M1GJ A --- ---
M18 E2E-X14MD1-M1GJ A --- ---
M30 E2E-X20MD1-M1GJ A --- ---
Shielded 3 mm
7 mm
10 mm
Unshielded
8 mm
14 mm
20 mm
Cable length Model
500 mm XS2W-D421-BY1
3
4
4
1
Internal Wiring
(Proximity Sensor end) (Wired end)
Appearance Model
NO Applicable connector code *NC Applicable connector code *
M8 E2E-X2D1-M1 CE2E-X2D2-M1 D
M12 E2E-X3D1-M1 CE2E-X3D2-M1 D
M18 E2E-X7D1-M1 CE2E-X7D2-M1 D
M30 E2E-X10D1-M1 CE2E-X10D2-M1 D
M8 E2E-X4MD1-M1 CE2E-X4MD2-M1 D
M12 E2E-X8MD1-M1 CE2E-X8MD2-M1 D
M18 E2E-X14MD1-M1 CE2E-X14MD2-M1 D
M30 E2E-X20MD1-M1 CE2E-X20MD2-M1 D
Shielded
Unshielded
5
E2E
DC 3-Wire, Pre-Wired Models
Note: Models with NPN NC output configurations are also available for all of the above models.
*1. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X2E1 5M).
*2. Models with robotics cables are also available. The model numbers are E2E-X @E1-R (example: E2E-X5E1-R).
*3. Models with different frequencies are also available. The model numbers are E2E-X @E@5 (example: E2E-X5E15).
*4. These models are also available with e-CON connectors (0.3-m cable). Add "-ECON" to the end of the model number (example: E2E-X2E1-ECON).
DC 3-Wire, Connector Models
Note: Models with NPN NC output configurations are also available for all of the above models.
* Refer to page 19 for details.
Appearance Sensing distance Model
Output configuration: NPN NO Output configuration: PNP NO
3 dia. E2E-CR6C1 E2E-CR6B1
4 dia. E2E-CR8C1 *1*2 E2E-CR8B1 *2
M5 E2E-X1C1 *1*2 E2E-X1B1 *2
5.4 dia. E2E-C1C1 *1*2 E2E-C1B1
M8 E2E-X1R5E1 *1*2 E2E-X1R5F1 *1*2
M12 E2E-X2E1 *1*2*3*4 E2E-X2F1 *1*2*3
M18 E2E-X5E1 *1*2*3*4 E2E-X5F1 *1*2*3
M30 E2E-X10E1 *1*2*3*4 E2E-X10F1 *2
M8 E2E-X2ME1 *2 E2E-X2MF1 *2
M12 E2E-X5ME1 *1*2*3*4 E2E-X5MF1 *2
M18 E2E-X10ME1 *1*2*3*4E
2E-X10MF1 *2
M30 E2E-X18ME1 *1*2*3*4 E2E-X18MF1 *2
Connec-
tor Appearance Sensing distance
Model Applicable connector
code *
Output configuration:
NPN NO
Output configuration:
PNP NO
M12
M8 E2E-X1R5E1-M1 E2E-X1R5F1-M1 B
M12 E2E-X2E1-M1 E2E-X2F1-M1 B
M18 E2E-X5E1-M1 E2E-X5F1-M1 B
M30 E2E-X10E1-M1 E2E-X10F1-M1 B
M8 E2E-X2ME1-M1 E2E-X2MF1-M1 B
M12 E2E-X5ME1-M1 E2E-X5MF1-M1 B
M18 E2E-X10ME1-M1 E2E-X10MF1-M1 B
M30 E2E-X18ME1-M1 E2E-X18MF1-M1 B
M8 M8
E2E-X1R5E1-M3 E2E-X1R5F1-M3 G
E2E-X2ME1-M3 E2E-X2MF1-M3 G
Shielded
0.6 mm
0.8 mm
1 mm
1 mm
1.5 mm
2 mm
5 mm
10 mm
Unshielded
2 mm
5 mm
10 mm
18 mm
Shielded
1.5 mm
2 mm
5 mm
10 mm
Unshielded
2 mm
5 mm
10 mm
18 mm
Shielded
1.5 mm
Unshielded
2 mm
6
E2E
AC 2-Wire, Pre-wired Models
*1. Models with different frequencies are also available. The model numbers are E2E-X @Y@5 (example: E2E-X5Y15).
*2. Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X2Y1 5M).
AC 2-wire, Connector Models
* Refer to page 19 for details.
AC/DC 2-Wire, Pre-wired Models
Note: These models do not conform to CE standards.
* Models are also available with 5-m cables. Add the cable length to the model number (example: E2E-X7T1 5M).
Accessories (Order Separately)
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
Appearance Sensing distance Model
NO NC
M8 E2E-X1R5Y1 E2E-X1R5Y2
M12 E2E-X2Y1 *1*2 E2E-X2Y2
M18 E2E-X5Y1 *1*2 E2E-X5Y2
M30 E2E-X10Y1 *1*2 E2E-X10Y2
M8 E2E-X2MY1 E2E-X2MY2
M12 E2E-X5MY1 *1*2 E2E-X5MY2
M18 E2E-X10MY1 *1 E2E-X10MY2
M30 E2E-X18MY1 *1 E2E-X18MY2
Connec-
tor Appearance Sensing distance
Model
NO
Applicable
connector
code *
NC
Applicable
connector
code *
M12
M12 E2E-X2Y1-M1 EE2E-X2Y2-M1 F
M18 E2E-X5Y1-M1 EE2E-X5Y2-M1 F
M30 E2E-X10Y1-M1 EE2E-X10Y2-M1 F
M12 E2E-X5MY1-M1 EE2E-X5MY2-M1 F
M18 E2E-X10MY1-M1 EE2E-X10MY2-M1 F
M30 E2E-X18MY1-M1 EE2E-X18MY2-M1 F
Appearance Sensing distance Operation mode Model
M12
NO
E2E-X3T1
M18 E2E-X7T1 *
M30 E2E-X10T1
Shielded
1.5 mm
2 mm
5 mm
10 mm
Unshielded
2 mm
5 mm
10 mm
18 mm
Shielded 2 mm
5 mm
10 mm
Unshielded 5 mm
10 mm
18 mm
Shielded 3 mm
7 mm
10 mm
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@for details.
7
E2E
Ratings and Specifications
E2E-X@D@ DC 2-Wire Models
*1. Use the E2E within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
*3. The residual voltage of each M1J-T Model is 5 V. When connecting to a device, make sure that the device can withstand the residual voltage. (Refer to page 23 for
details.)
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X2D@E2E-X4MD@E2E-X3D@E2E-X8MD@E2E-X7D@E2E-X14MD@E2E-X10D@E2E-X20MD@
Sensing distance 2 mm ±10% 4 mm ±10% 3 mm ±10% 8 mm ±10% 7 mm ±10% 14 mm ±10% 10 mm ±10% 20 mm ±10%
Set distance *10 to 1.6 mm 0 to 3.2 mm 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm
Differential travel 15% max. of sensing distance 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 13 and 14.
Standard sensing
object
Iron,
8× 8 × 1mm
Iron,
20 × 20 × 1 mm
Iron,
12 × 12 × 1 mm
Iron,
30 × 30 × 1 mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency
*21.5 kHz 1 kHz 0.8 kHz 0.5 kHz 0.4 kHz 0.1 kHz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Control
output
Load
current 3 to 100 mA, Diagnostic output: 50 mA for -D1(5)S Models
Residual
voltage
*3
3 V max. (Load current: 100 mA, Cable length: 2 m, M1J-T Models only: 5 V max.)
Indicators D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Diagnostic output
delay 0.3 to 1 s
Protection circuits Surge suppressor, Load short-circuit protection (for control and diagnostic output)
Ambient
temperature range Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)
Ambient
humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature
influence
±15% max. of sensing distance
at 23°C in the temperature range
of 25 to 70°C
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m), Connector Models, or Pre-wired Connector Models (Standard cable length: 0.3 m)
Weight
(pack-
ed
state)
Pre-wired
Models Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Pre-wired
Connector
Models
--- Approx. 40 g Approx. 70 g Approx. 110 g
Connector
Models Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Materi-
als
Case Stainless steel (SUS303) Nickel-plated brass
Sensing sur-
face PBT
Clamping
nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 16 for details.
8
E2E
E2E-X@E@/F@ DC 3-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. When using an M8 Model at an ambient temperature between 70 and 85°C, supply 10 to 30 VDC to the Sensor and make sure that the Sensor has a control output
of 100 mA maximum.
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E
-X1R5E@/F@
E2E
-X2ME@/F@
E2E
-X2E@/F@
E2E
-X5ME@/F@
E2E
-X5E@/F@
E2E
-X10ME@/F@
E2E-X10E@/
F@
E2E
-X18ME@/F@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 13 and 14.)
Standard sensing
object
Iron,
8× 8 × 1mm Iron, 12 × 12 × 1 mm Iron,
15 ×15 × 1mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency
*12 kHz 0.8 kHz 1.5 kHz 0.4 kHz 0.6 kHz 0.2 kHz 0.4 kHz 0.1 kHz
Power supply voltage
(operating voltage
range) *2
12 to 24 VDC (10 to 40 VDC), ripple (p-p): 10% max.
Current consumption 13 mA max.
Control
output
Load
current *2200 mA max.
Residual
voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1 Models: NO
E2 Models: Refer to the timing charts under I/O Circuit Diagrams on page 16 for details.
F1 Models: NO
Protection circuits Load short-circuit protection, Surge suppressor, Reverse polarity protection
Ambient
temperature range *2Operating/Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity
range Operating/Storage: 35% to 95%
Temperature
influence
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Pre-
wired
Models
Approx. 65 g Approx. 75 g Approx. 150 g Approx. 195 g
Connec-
tor
Models
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
surface PBT
Clamp-
ing nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
9
E2E
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
Size 3 dia. 4 dia. M5 5.4 dia.
Shielded Shielded
Item Model E2E-CR6C/B@E2E-CR8C/B@E2E-X1C/B@E2E-C1C/B@
Sensing distance 0.6 mm ±15% 0.8 mm ±15% 1 mm ±15%
Set distance 0 to 0.4 mm 0 to 0.5 mm 0 to 0.7 mm
Differential travel 15% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.)
Standard sensing object Iron, 3 × 3 × 1 mm Iron, 5 × 5 × 1 mm
Response frequency *2 kHz 3 kHz
Power supply voltage
(operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 10 mA max. 17 mA max.
Control
output
Load
current
Open-collector output,
80 mA max. (30 VDC max.) Open-collector output, 100 mA max. (30 VDC max.)
Residual
voltage
1 V max.
(Load current: 80 mA,
Cable length: 2 m)
2 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
C1/B1 Models: NO
C2 Models: NC
Protection circuits Reverse polarity protection, Surge suppressor
Ambient
temperature range Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95%
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence
±5% max. of sensing dis-
tance at rated voltage in the
rated voltage ±10% range
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP66 IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 60 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
surface Heat-resistant ABS
Clamping
nuts Nickel-plated brass (E2E-X1C/B@ only)
Toothed
washer Zinc-plated iron (E2E-X1C/B@ only)
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 17 for details.
10
E2E
E2E-X@Y@ AC 2-Wire Models
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least 25°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of
5 to 200 mA max.
Size M8 M12 M18 M30
Shielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded
Item Model E2E-X1R5Y@E2E-X2MY@E2E-X2Y@E2E-X5MY@E2E-X5Y@E2E-X10MY@E2E-X10Y@E2E-X18MY@
Sensing distance 1.5 mm ±10% 2 mm ±10% 5 mm ±10% 10 mm ±10% 18 mm ±10%
Set distance 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm 0 to 14 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.)
Standard sensing
object
Iron,
8× 8 × 1mm Iron, 12 × 12 × 1 mm Iron,
15 × 15 × 1 mm
Iron,
18 × 18 × 1 mm Iron, 30 × 30 × 1 mm Iron,
54 × 54 × 1 mm
Response frequency 25 Hz
Power supply voltage
(operating voltage
range)*1 24 to 240 VAC (20 to 264 VAC), 50/60 Hz
Leakage current 1.7 mA max.
Control
output
Load
current *25 to 100 mA 5 to 200 mA 5 to 300 mA
Residual
voltage Refer to Engineering Data on page 15.
Indicators Operation indicator (red)
Operation mode
(with sensing object
approaching)
Y1 Models: NO
Y2 Models: NC
Protection circuits Surge suppressor
Ambient temperature
range *1*2
Operating/Storage: 25 to 70°C
(with no icing or condensation) Operating/Storage: 40 to 85°C (with no icing or condensation)
Ambient
humidity range Operating/storage: 35% to 95% (with no condensation)
Temperature
influence
±10% max. of sensing distance
at 23°C in the temperature range
of 25 to 70°C
±15% max. of sensing distance at 23°C in the temperature range of 40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC (M8 Models: 2,000 VAC), 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2
10 times each in X, Y, and
Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection Pre-wired Models : IEC 60529 IP67, in-house standards: oil-resistant
Connector Models : IEC 60529 IP67
Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight
Pre-
wired
Models
Model
Approx. 60 g Approx. 70 g Approx. 130 g Approx. 175 g
Connec-
tor
Models
Approx. 15 g Approx. 25 g Approx. 40 g Approx. 90 g
Materials
Case Stainless steel (SUS303) Nickel-plated brass
Sensing
surface PBT
Clamp-
ing nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
Refer to the timing charts under I/O Circuit Diagrams on page 18 for details.
11
E2E
AC/DC 2-Wire Models
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. Power Supply Voltage Waveform:
Use a sine wave for the power supply. Using a rectangular AC power supply may result in faulty reset.
Size M12 M18 M30
Shielded Shielded
Item Model E2E-X3T1 E2E-X7T1 E2E-X10T1
Sensing distance 3 mm ±10% 7 mm ±10% 10 mm ±10%
Set distance 0 to 2.4 mm 0 to 5.6 mm 0 to 8 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 13.)
Standard sensing object Iron, 12 × 12 × 1 mm Iron, 18 × 18 × 1 mm Iron, 30 × 30 × 1 mm
Response
frequency *1
DC 1 kHz 0.5 kHz 0.4 kHz
AC 25 Hz
Power supply voltage
(operating voltage range) *2
24 to 240 VDC (20 to 264 VDC)
48 to 240 VAC (40 to 264 VAC)
Leakage current DC: 1 mA max.
AC: 2 mA max.
Control
output
Load
current 5 to 100 mA
Residual
voltage
DC: 6 V max. (Load current: 100 mA, Cable length: 2 m)
AC: 10 V max. (Load current: 5 mA, Cable length: 2 m)
Indicators Operation indicator (red), Setting indicator (green)
Operation mode
(with sensing object
approaching)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 16 for details.)
Protection circuits Load short-circuit protection (20 to 40 VDC only), Surge suppressor
Ambient temperature range Operating: 25 to 70°C, Storage: 40 to 85°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95%
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 80 g Approx. 140 g Approx. 190 g
Materials
Case Nickel-plated brass
Sensing
surface PBT
Clamping
nuts Nickel-plated brass
Toothed
washer Zinc-plated iron
Accessories Instruction manual
12
E2E
I/O Circuit Diagrams
E2E-X@D@ DC 2-Wire Models
Operation
mode Model Timing Chart Output circuit
Without
self-
diagnostic
output:
NO
E2E-X@D1-N
E2E-X@D1-M1G(J)
E2E-X@D1-(M1TGJ)-U
E2E-X@D1-M3G
E2E-X@D1-M1J-T
Without
self-
diagnostic
output:
NC
E2E-X@D2-N
E2E-X@D2-M1G
E2E-X@D2-(M1TGJ)-U
E2E-X@D2-M3G
With self-
diagnostic
output:
NO
E2E-X@D1S
E2E-X@D1S-M1
(%) 80 0100
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
0 V
+V
4
1
Load
Brown
Blue
Polarity: Yes
Note: The load can be connected to either the
+V or 0 V side.
Prox-
imity
Sensor
main
circuit
0 V
(+V)
+V
(0 V)
3
4
Load
Prox-
imity
Sensor
main
circuit
Polarity: None
Note 1. The load can be connected to either the +V or
0 V side.
2. The E2E-X@D1-M1J-T has no polarity.
Therefore, terminals 3 and 4 have no polarity.
0
(%) 100
Sensing
object
Rated
sensing
distance
Sensing area
Non-sensing
area
Proximity Sensor
ON
OFF
ON
OFF
Operation
indicator (red)
Control output
0 V
+V
2
1
Load
Brown
Blue
Note: The load can be connected to either the +V
or 0 V side.
Prox-
imity
Sensor
main
circuit
(%) 80 0100
Sensing
object
Rated
sensing
distance
Stable sensing area
Non-sensing
area
Unstable
sensing
area
Set position
Proximity Sensor
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Setting indicator
(green)
Operation
indicator (red)
Control output
Diagnostic output
The diagnostic output is ON when there is a coil
burnout or the sensing object is located in the
unstable sensing area for 0.3 s or longer.
+V
+V
0
Load
Load
Brown (4)
Orange (2)
(diagnostic
output)
Blue (3)
Note: Connect both the loads to the +V side of
the control output and diagnostic output.
Prox-
imity
Sensor
main
circuit
16
E2E
Sensor I/O Connectors
*1. Refer to Connection Diagrams on page 20 for information on Proximity Sensor and I/O Connector connections.
*2. Refer to Introduction to Sensor I/O Connectors for details and for information on Robotics Cables.
Connector Applicable
connector code
Connector model
number
Applicable Proximity Sensor
model number
Connection
diagram No. *1
Screw Appearance Cable
length
M12
2 m
AXS2F-D421-DA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D421-DC0-A E2E-X@D1-M1J-T 3
E2E-X@E/F1-M1 9
CXS2F-D421-DD0 E2E-X@D1-M1 2
DXS2F-D421-D80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
EXS2F-A421-DB0-A E2E-X@Y1-M1 11
FXS2F-A421-D90-A E2E-X@Y2-M1 12
5 m
AXS2F-D421-GA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D421-GC0-A E2E-X@D1-M1J-T 3
E2E-X@E/F1-M1 9
CXS2F-D421-GD0 E2E-X@D1-M1 2
DXS2F-D421-G80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
EXS2F-A421-GB0-A E2E-X@Y1-M1 11
FXS2F-A421-G90-A E2E-X@Y2-M1 12
2 m
AXS2F-D422-DA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D422-DC0-A E2E-X@D1-M1J-T 3
E2E-X@E/F1-M1 9
CXS2F-D422-DD0 E2E-X@D1-M1 2
DXS2F-D422-D80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
EXS2F-A422-DB0-A E2E-X@Y1-M1 11
5 m
AXS2F-D422-GA0-A E2E-X@D1-M1G 1
E2E-X@D1-M1GJ
BXS2F-D422-GC0-A E2E-X@D1-M1J-T 3
E2E-X@E/F1-M1 9
CXS2F-D422-GD0 E2E-X@D1-M1 2
DXS2F-D422-G80-A
E2E-X@D2-M1 7
E2E-X@D2-M1(G) 6
E2E-X@D1S-M1 5
EXS2F-A422-GB0-A E2E-X@Y1-M1 11
2 m
H
XS5F-D421-D80-P
E2E-X@D@-M1TGJ-U 13, 14
5 m XS5F-D421-G80-P
M8
*2
2 m
G
XS3F-M421-402-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E/F1-M3 10
5 m XS3F-M421-405-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E/F1-M3 10
2 m XS3F-M422-402-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E/F1-M3 10
5 m XS3F-M422-405-R
E2E-X@D1-M3G 4
E2E-X@D2-M3G 8
E2E-X@E/F1-M3 10
Straight
L-shape
Smartclick Connector,
Straight
Straight
L-shape
19
E2E
Connections for Sensor I/O Connectors
* Different from Proximity Sensor wire colors.
Connection
diagram No.
Proximity Sensor Sensor I/O Connector
model number Connections
Type Operation
mode Model
1DC 2-wire
(IEC pin wiring)
NO
E2E-X@D1-M1G(J)
2
DC 2-wire
(previous pin
wiring)
E2E-X@D1-M1
3DC 2-wire
(no polarity) E2E-X@D1-M1J-T
4DC 2-wire
(M8 connector) E2E-X@D1-M3G
5
DC 2-wire
(diagnostic
type)
E2E-X@D1S-M1
6DC 2-wire
(IEC pin wiring)
NC
E2E-X@D2-M1G
7
DC 2-wire
(previous pin
wiring)
E2E-X@D2-M1
8DC 2-wire
(M8 connector) E2E-X@D2-M3G
XS2F-D42@-@A0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
4
3
2
1
4
3
2
1
XS2FE2E
Main
circuit
Brown (+)
Blue ()
XS2F-D42@-@D0
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
2
4
3
2
1
4
3
1
XS2FE2E
Blue ()
Brown (+)
Main
circuit
XS2F-D42@-@C0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (not connected)
Black () (+)
Main
circuit
Blue (+) ()
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
*
XS3F
4
3
2
1
4
3
2
1
E2E
Brown (+)
White (not connected)
Blue (not connected)
Black ()
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (not connected)
White (diagnostic output) (+)
Blue (0 V)
Black (control output) (+)
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
White ()
Blue (not connected)
Brown (+)
Black (not connected)
Main
circuit
XS2F-D42@-@80-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
White (+)
Blue ()
Brown (not connected)
Black (not connected)
Main
circuit
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
*
XS3F
4
3
2
1
4
3
2
1
E2E
White ()
Blue (not connected)
Brown (+)
Black (not connected)
Main
circuit
20
E2E
* Different from Proximity Sensor wire colors.
Connection
diagram No.
Proximity Sensor Sensor I/O Connector
model number Connections
Type Operation
mode Model
9DC 3-wire
NO
E2E-X@E/F1-M1
10 DC 3-wire
(M8 connector) E2E-X@E/F1-M3
11
AC 2-wire
NO E2E-X@Y1-M1
12 NC E2E-X@Y2-M1
13
DC 2-wire
(Smartclick
connector)
NO E2E-X@D1-
M1TGJ-U
14
DC 2-wire
(Smartclick
connector)
NC E2E-X@D2-
M1TGJ-U
Refer to Introduction to Sensor I/O Connectors for details.
XS2F-D42@-@C0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
XS2F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
Blue (0 V)
Black (output)
Main
circuit
XS3F-M42@-40@-R
1: Straight
2: L-shape
2: 2-m cable
5: 5-m cable
XS3F
4
3
2
1
4
3
2
1
E2E
Brown (+V)
White (not connected)
Blue (0 V)
Black (output)
Main
circuit
XS2F-A42@-@B0-A
1: Straight
2: L-shape
D: 2-m cable
G: 5-m cable
XS2F
4
3
2
1
4
3
2
1
E2E
Brown
Blue
Main
circuit
XS2F-A421-@90-A
D: 2-m cable
G: 5-m cable
*
XS2F
4
3
2
1
4
3
2
1
E2E
Blue (not connected)
Black (not connected)
Brown
White
Main
circuit
XS5F-D421-@80-P
D: 2-m cable
G: 5-m cable
XS5F
4
3
2
1
4
3
2
1
E2E-X@-M1TGJ
Blue (not connected)
Black ()
Brown (+)
White (not connected)
Main
circuit
XS5F-D421-@80-P
D: 2-m cable
G: 5-m cable
XS5F
4
3
2
1
4
3
2
1
E2E-X@-M1TGJ
Blue (not connected)
Black (not connected)
Brown (+)
White ()
Main
circuit
21
E2E
Pre-wired Models
(Shielded)
F
Mounting Hole Dimensions
Dimension M5 M8 M12
F (mm) 5.5 dia. 8.5 dia. 12.5 dia.
+0.5
0+0.5
0+0.5
0
9.7 dia. 17.5
25
15
8
M5 ×0.5 4
*
Operation indicator (red)
Two clamping nuts
Two toothed washers
*2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.14 mm2, Insulator diameter: 0.9 mm), Standard length: 2 m
Robotics Cable Models:
2.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross
section: 0.15 mm2, Insulator diameter: 1.05 mm), Standard length: 2 m
The cable can be extended up to 100 m (separate metal conduit).
Diagram 4 E2E-X1@Pre-wired Models (Unshielded)
30 7
8
26
3
M8 ×1
13
15 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter:
1.3 mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter:
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm
2
, Insulator diameter:
1.27 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm
2
, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D Models: Operation indicator (red) and setting indicator (green), E/F Models: Operation indicator (red)
Diagram 5 E2E-X2D@
E2E-X1R5E@/F@
30 7
8
26
13 63
15 dia.
M8 ×1
6.1 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate metal conduit).
*2. D Models: Operation indicator (red) and setting indicator (green), E/F Models: Operation indicator (red)
Diagram 6 E2E-X4MD@
E2E-X2ME@/F@
Diagram 7 E2E-X1R5Y@
15 dia.
3
13
36
8
7
40
M8 ×1
*
Toothed
washer
Two clamping nuts
Operation indicator (red)
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Diagram 8 E2E-X2MY@
40 7
8
36
13 63
15 dia.
M8 ×1
6.1 dia.
*
Operation indicator (red)
Two clamping nuts
Toothed
washer
4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
38 9
10
33
17 4
21 dia.
*1
M12 ×1
Indicators * 2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
4-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator
diameter: 1.3 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for
the diagnostic output.
*2. D Models: Operation indicator (red) and setting indicator (green), E/F Models: Operation indicator (red)
15.6
5.9
4
3
2
15
1
Pre-wired e-CON Connector Models
Connector: Product code
37104-3163-000FL (Sumitomo 3M)
Diagram 9 E2E-X3D@
E2E-X2E@/F@
Diagram 10 E2E-X8MD@
E2E-X5ME@/F@
38 9
10
33
17 74
9 dia.
21 dia.
M12 ×1
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.3 mm), Standard length: 2 m
Robotics Cable Models:
4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter:
1.27 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output and up to 100 m for
the diagnostic output.
*2. D Models: Operation indicator (red) and setting indicator (green), E/F Models: Operation indicator (red)
15.6
5.9
4
3
2
15
1
Pre-wired e-CON Connector Models
Connector: Product code
37104-3163-000FL (Sumitomo 3M)
25
E2E
Diagram 11 E2E-X2Y@
43 9
10
38
17 4
21 dia.
M12 ×1
*
Operation indicator (red)
Two clamping nuts
Toothed
washer
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
Diagram 12 E2E-X5MY@
43 9
10
38
17 74
21 dia.
M12 ×1
9 dia.
*
Operation indicator (red)
Two clamping nuts
Toothed
washer
4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m
(separate metal conduit).
Mounting Hole Dimensions
Pre-wired Models (Shielded)
F
Dimension M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0+0.5
0+0.5
0+0.5
0
60 9
10
55
17
21 dia.
4
M12 ×1
*1
Indicators *2
Two clamping nuts
Toothed
washer
*1 4-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
The cable can be extended up to 200 m (separate
metal conduit).
*2 Operation indicator (red), Setting indicator (green)
Diagram 13 E2E-X3T1 Pre-wired Models (Unshielded)
43 12
10
38
4
24
29 dia.
*1
M18 ×1
Indicators *2
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant Cables:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D/T Models: Operation indicator (red), Setting indicator (green)
E/F/Y Models: Operation indicator (red)
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
Diagram 14 E2E-X7D@/E2E-X5E@/F@
E2E-X5Y@/E2E-X7T1
10
43 12
10
38
4
24
29 dia.
M18 ×1
14.8 dia.
*1
*1
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D/T Models: Operation indicator (red), Setting indicator (green)
E/F/Y Models: Operation indicator (red)
Indicators *2
Two clamping nuts
Toothed washer
Diagram 15 E2E-X14MD@/E2E-X10ME@/F@
E2E-X10MY@
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
26
E2E
48 12
10
43
5
36
42 dia.
M30 ×1.5
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
Models with Highly Oil-resistant:
6-dia. polyurethane-insulated round cable with 2 conductors (Conductor cross section:
0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D/T Models: Operation indicator (red), Setting indicator (green)
E/F/Y Models: Operation indicator (red)
Diagram 16 E2E-X10D
@/
E2E-X10E
@/
F
@
E2E-X10Y@/E2E-X10T1
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
48 12
10
13
43
5
36
42 dia.
M30 ×1.5
26.8 dia.
*1
Indicators *2
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
Robotics Cable Models:
6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.74 mm), Standard length: 2 m
The cable can be extended (separate metal conduit) up to 200 m for the control output
and up to 100 m for the diagnostic output.
*2. D/T Models: Operation indicator (red), Setting indicator (green)
E/F/Y Models: Operation indicator (red)
Diagram 17 E2E-X20MD
@/
E2E-X18ME
@/
F
@
E2E-X18MY@
5.9
4
3
2
15
1
15.6
Pre-wired e-CON
Connector Models
Connector: Product code
37104-2206-000FL
(Sumitomo 3M)
M8 Connector Models
(Shielded)
M8 Connector Models
(Unshielded)
M8 ×1
39
31
8
26
13 3
15 dia.
M8 ×1Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator
(red), Setting
indicator (green)
E/F Models: Operation indicator
(red)
Diagram 28 E2E-X2D@-M3G/E2E-X1R5E1-M3/F@
M8 ×1
39
31
8
26
13 63
15 dia.
M8 ×1
6.1 dia.
Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator
(red), Setting
indicator (green)
E/F Models: Operation indicator
(red)
Diagram 29 E2E-X4MD@-M3G/E2E-X2ME1-M3/F@
M12 Connector Models
(Shielded)
M12 Connector Models
(Unshielded)
M12 ×1
43
30
8
26
13 3
15 dia.
M8 ×1Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator (red),
Setting indicator (green)
E/F Models: Operation indicator (red)
Diagram 18 E2E-X2D@-M1(G)
E2E-X1R5E1-M1/F@
M12 ×1
43
30
8
26
13 63
6.1 dia.
15 dia.
M8 ×1Indicators*
Two clamping nuts
Toothed washer
* D Models: Operation indicator (red),
Setting indicator (green)
E/F Models: Operation indicator (red)
Diagram 19 E2E-X4MD@-M1(G)
E2E-X2ME1-M1/F@
27
E2E
M12 ×1
48
10
33
17 4
21 dia.
M12 ×1Indicators *
Toothed washer
Two clamping nuts
* D Models: Operation indicator (red),
Setting indicator (green)
E/F Models: Operation indicator (red)
Diagram 20 E2E-X3D
@
-M1
(G)
E2E-X2E1-M1/F@
M12 ×1
48
10
33
17 74
21 dia.
M12 ×1
9 dia.
Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator (red), Setting indicator (green)
E/F Models: Operation indicator (red)
Diagram 21 E2E-X8MD@-M1(G)
E2E-X5ME1-M1/F@
M12 ×1
53
10
38
17 4
21 dia.
M12 ×1Operation indicator (red)
Toothed washer
Two clamping nuts
Diagram 22 E2E-X2Y@-M1
M12 ×1
53
10
38
17 74
21 dia.
M12 ×1
9 dia.
Operation indicator (red)
Toothed washer
Two clamping nuts
Diagram 23 E2E-X5MY@-M1
M12 ×1
53
10
38
24 4
29 dia.
M18 ×1
Indicators*
Two clamping nuts
Toothed washer
* D Models: Operation indicator (red), Setting indicator (green)
E/Y Models: Operation indicator (red)
Diagram 24 E2E-X7D@-M1(G)/E2E-X5E1-M1
E2E-X5Y@-M1
M12 ×1
53
10
38
24 10 4
29 dia.
M18 ×1
14.8 dia.
Indicators*
Toothed washer
Two clamping nuts
* D Models: Operation indicator (red), Setting indicator (green)
E/Y Models: Operation indicator (red)
Diagram 25 E2E-X14MD@-M1(G)/E2E-X10ME1-M1
E2E-X10MY@-M1
58
10
43
36 5
42 dia.
M30 ×1.5
M12 ×1
Indicators*
Two clamping nuts
Toothed washer
* D Models: Operation indicator (red), Setting indicator (green)
E/Y Models: Operation indicator (red)
Diagram 26 E2E-X10D@-M1(G)/E2E-X10E1-M1
E2E-X10Y@-M1
58
10
43
36 13 5
42 dia.
M30 ×1.5
26.8 dia.
M12 ×1
Indicators*
Two clamping nuts
Toothed washer
* D Models: Operation indicator (red), Setting indicator (green)
E/Y Models: Operation indicator (red)
Diagram 27 E2E-X20MD@-M1(G)/E2E-X18ME1-M1
E2E-X18MY@-M1
Mounting Hole Dimensions
F
Dimensions M8 M12 M18 M30
F (mm) 8.5 dia. 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0+0.5
0+0.5
0+0.5
0
28
E2E
Pre-wired Connector Models (Unshielded)
Dimension M12 M18 M30
F (mm) 12.5 dia. 18.5 dia. 30.5 dia.
+0.5
0+0.5
0+0.5
0
Pre-wired
C
onnector Models
(S
hielded
)
Mounting Hole Dimensions
F
7
30
8
26
3
M8 ×1
*1
M12 ×1
Indicators *2
Toothed washer
Two clamping nuts *1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
*3. The connectors for M1TGJ models
are XS5 Smartclick connectors
15 dia.
13
Diagram 30 E2E-X2D1-M1TGJ-U *3
Diagram 31 E2E-X3D1-M1GJ
E2E-X3D1-M1J-T
E2E-X3D1-M1TGJ-U *3
9
38
10
33
4
M12 ×1
*1
M12 ×1
21 dia.
17
Indicators *2
Toothed washer
Two clamping nuts *1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
*3. The connectors for M1TGJ models
are XS5 Smartclick connectors
Diagram 33 E2E-X7D1-M1GJ
E2E-X7D1-M1J-T
E2E-X7D1-M1TGJ-U *3
12
43
*1
10
38
4
M18 ×1
M12 ×1
29 dia.
24
Indicators *2
Toothed washer
Two clamping nuts *1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting indicator (green)
*3. The connectors for M1TGJ models
are XS5 Smartclick connectors
Diagram 35 E2E-X10D1-M1GJ
E2E-X10D1-M1J-T
E2E-X10D1-M1TGJ-U *3
12
48
10
43
36 5
42 dia.
M30 ×1.5
*1
M12 ×1
Indicators *2
Toothed washer
Two clamping nuts *1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
*3. The connectors for M1TGJ models
are XS5 Smartclick connectors
Diagram 32 E2E-X8MD1-M1GJ 9
38
10
33
17 74
9 dia.
21 dia.
M12 ×1
*1
M12 ×1
Indicators *2
Toothed washer
Two clamping nuts *1. 4-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
29
E2E
Dimensions for Proximity Sensors with Sensor I/O Connectors
Accessories (Order Separately)
Sensor I/O Connectors
Refer to Introduction to Sensor I/O Connectors for details.
Diagram 34 E2E-X14MD1-M1GJ 12
43
10
38
24
10 4
29 dia.
M18 ×1
14.8 dia.
*1
M12 ×1
Indicators*2
Toothed washer
Two clamping nuts *1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
Diagram 36 E2E-X20MD1-M1GJ
12
48
*1
10
43
36 13 5
26.8 dia.
42 dia.
M30 ×1.5
M12 ×1
Indicators*2
Toothed washer
Two clamping nuts *1. 6-dia. vinyl-insulated round cable,
Standard length: 300 mm
*2. Operation indicator (red), Setting
indicator (green)
L1
L2
L1
L2
Straight Connectors
L-shape Connectors
Straight Connectors
L-shape Connectors
Shielded Models Unshielded Models Dimensions with the X
S
2F
C
onnected (Unit: mm)
* The overall length of the Sensor is different between AC and DC
Models for Sensors with diameters of M12. This will change the
dimension when the I/O Connector is connected.
Dimensions with the XS3F Connected (Unit: mm)
Dimension
Sensor diameter L1 L2
M8 Approx. 75 Approx. 62
M12* DC Approx. 80 Approx. 67
AC Approx. 85 Approx. 72
M18 Approx. 85 Approx. 72
M30 Approx. 90 Approx. 77
Dimension
Sensor diameter L1 L2
M8 Approx. 65 Approx. 54
Mounting Brackets
Protective Covers
Sputter Protective Covers
Refer to Y92@ for details.
30