A-342
ZUP
・All specifications are subject to change without notice.
(*1) Minimum voltage is guaranteed to maximum 0.2% of the rated out-
put voltage.
(*2) Minimum current is guaranteed to maximum 0.4% of the rated out-
put current.
(*3) Time for recovery to within +/-50mV against current change of 50%
to 100%.
(*4) From zero volts to full scale , resistive load and current setting at
maximum.
(*5) From no load to full load , constant input voltage.
(Measure with JEITA RC-9131 probe.)
(*6) From 85~132Vac or 170~265Vac constant load.
(*7) At cold start Ta=25 …C.
(*8) Change in output over 8 hour interval constant line, load and ambi-
ent temperature following 30-minutes warm-up.
(*9) Given for control of the output via the serial communication or via
front panel controls.
(*10) Inverter shut down method, manual reset (OVP will shut down out-
put)
(*11) For cases where conformance to various safety specs. (UL, IEC,
etc.) are required, to be described as 100-240VAC (50/60Hz) on
name plate.
(*12) At 100V/200V and Maximum Output Power.
- When forced air cooling, refer to derating curve.
ITEMS/UNITS
MODEL
ZUP6-33 ZUP6-66
ZUP6-132 ZUP10-20
ZUP10-40
ZUP10-80 ZUP20-10
OUTPUT VOLTAGE (*1) V 0-6 0-10
OUTPUT CURRENT (*2) A 0-33 0-66 0-132 0-20 0-40 0-80 0-10
RATED OUTPUT POWER
W 198 396 792 200 400 800 200
CONSTANT
VOLTAGE
LOAD REGULATION 0.005%+2mV From No load to Full load, constant input voltage.
LINE REGULATION 0.005%+1mV From 85-132VAC or 170-265VAC, constant load.
RMS RIPPLE (5Hz-1MHz Bandwidth)
mV 5 5 8 5 5 8 5
RIPPLE (pk to pk) (20MHz Bandwidth)
mV 50 50 100 50 50 90 50
RECOVERY TIME (*3) mS 1 0.5
TEMPERATURE COEFFICIENT 30ppm/…C from rated voltage following 30-minute warm-up.
TEMPERATURE DRIFT
0.01%+2mV Change in output over 8-hour interval under constant line, load and ambient temp following30-minute warm-up.
UP PROGRAMMING RESPONSE TIME (*4)
mS 50 50 60 50 50 60 50
DOWN PROGRAMMING
FULL LOAD mS 50 50 50 50 50 50 50
RESPONSE TIME NO LOAD mS 250 350
CONSTANT
CURRENT
LOAD REGULATION (*5) 0.01%+5mA 0.01%+5mA 0.07%+10mA 0.01%+5mA 0.01%+5mA 0.07%+10mA 0.01%+5mA
LINE REGULATION (*6) 0.01%+2mA 0.01%+2mA 0.01%+5mA 0.01%+2mA 0.01%+2mA 0.01%+5mA 0.01%+2mA
RMS RIPPLE (5Hz-1MHz Bandwidth)
mA 50 100 200 25 50 100 15
TEMPERATURE COEFICIENT 100ppm/ …C from rated current following 30-minute warm-up.
TEMPERATURE DRIFT (*8) 0.02%+5mA 0.02%+5mA 0.05%+10mA 0.02%+5mA 0.02%+5mA 0.05%+10mA 0.02%+5mA
PROGRAM
MING (*9)
RESOLUTION
Better than 0.028% of rated output voltage
VOLTAGE ACCURACY 0.02%+5mV 0.02%+8mV
RESOLUTION
Better than 0.03% of rated output current
CURRENT ACCURACY 0.4%+40mA
OVERVOLTAGE PROTECTION (*10) V 0-7.5 0-13
HOLD-UP TIME 20mS At 100V/200VAC, rated output voltage and output current.
DISPLAY
VOLTAGE 3 digits ( 6v; 20v; 36v; 60v; 80v); 3.5 digits ( 10v; 120v ) accuracy: 0.2% +/- 2 digits.
CURRENT 3.5 digits (132A); All others 3 digits, accuracy: 0.5% +/- 3 digits.
STATUS CV/CC, Alarm, Fold, Local/Remote, On/Off.
OUTPUT PROTECTIONS Over Voltage, Over Temperature, Foldback.
INPUT
INPUT VOLTAGE (*11) 85-265Vac Continuous, 47-63Hz
INPUT CURRENT (*12) A 3.0/1.5 5.6/2.7 11.2/5.4 2.9/1.4 5.6/2.7 11.2/5.4 2.9/1.4
INRUSH CURRENT ( 100/200V ) A 15/30 (*7) 15 30 15/30 (*7) 15 30 15/30 (*7)
EFFICIENCY ( *12 ) % 69/72 74/77 74/77 73/77 79/82 77/81 74/78
INPUT CURRENT HARMONICS Complies with EN61000-3-2, Class A
POWER FACTOR (TYP) 0.99 at 100/200Vac, 100% load.
ENVIRONMENT
OPERATING TEMPERATURE 0 to 50 …C ; 100% Load.
OPERATING HUMIDITY 30-90% RH ( No dewdrop ).
STORAGE TEMPERATURE -20 to 70 …C
STORAGE HUMIDITY 10 - 95% RH (No dewdrop).
MECHANICAL
VIBRATION 10-55Hz, Amplitude (sweep 1 min ) 2G, X, Y, Z, When mounted with mounting screws.
SHOCK Less than 20G
WEIGHT Kg 2.9 3.2 5.8 2.9 3.2 5.8 2.9
SIZE (W x H x D) mm 200W and 400W units: 70 x 124 x 350. 800W units: 140 x 124 x 350 (Refer to outline drawing)
EXTERNAL
CONTROL
FUNCTIONS
OUTPUT ON/OFF By TTL Signal or Dry Contact (Refer to instruction manual).
OUTPUT GOOD Open collector (Refer to instruction manual).
OUTPUT VOLTAGE PROGRAMMING
By Voltage ( 0-4V ) or by Resistance ( 0-4K ) (Refer to instruction manual).
OUTPUT CURRENT PROGRAMMING
By Voltage ( 0-4V ) or by Resistance ( 0-4K ) (Refer to instruction manual).
REMOTE SENSING Maximum 0.5V drop on each load wire for model up to 60V and 2V for the 80V, 120V models
COMMUNICATION INTERFACE RS232 and RS485 Built-in, IEEE488 Optional.
APPROVALS
SAFETY STANDARDS UL3111-1, EN61010-1
EMC STANDARDS EN61326-1, IEC 61326-1, FCC part 15 (class A).
CONDUCTED EMI EN55022-B, FCC-B, VCCI-2
RADIATED EMI EN55022-A, FCC-A, VCCI-1
SERIES OPERATION Up to 2 units (Refer to instruction manual).
PARALLEL OPERATION Master - Slave method; up to 5 units (Refer to instruction manual).
COOLING Forced air by blower fan (Blower fan is mounted within unit).
WITHSTAND VOLTAGE Input - Chassis...2.0kVAC 1 min, Input - Output...3.0kVac 1 min, Output - GND...500VAC 1 min.
ISOLATION RESISTANCE More than 100MOhm at 25 …C and 70% R.H.
ZUP Specifications
ZUP SERIES