https://www.phoenixcontact.com/us/products/2905909 Uninterruptible power supply - TRIOUPS-2G/1AC/1AC/230V/750VA - 2905909 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) 1AC/1AC/750 VA uninterruptible power supply with integrated energy storage, lead AGM, VRLA technology, 24 V DC, 3.4 Ah for 230 V AC applications. Product Description UPS modules with integrated energy storage are particularly space saving: UPS module and energy storage are combined in one housing. It's just a case of connecting a power supply upstream. The TRIO AC-UPS ensures seamless transition to battery operation thanks to the pure sine curve. Connected industrial PCs can be shut down safely via the integrated USB interface. Why buy this product Smooth transition, thanks to the pure sine curve: the sine generated in battery operation is synchronous with the mains previously used for supply Space saving: UPS module and energy storage combined in one housing Long buffer times with integrated VRLA energy storage, can be extended with additional energy storage USB interface for connection to higher-level controllers such as industrial PCs Startup from energy storage possible, even without mains input Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626007502 Weight per Piece (excluding packing) 6,140.000 g Custom tariff number 85371091 Country of origin Germany Technical data Dimensions 04/14/2017 Page 1 / 6 https://www.phoenixcontact.com/us/products/2905909 Uninterruptible power supply - TRIOUPS-2G/1AC/1AC/230V/750VA - 2905909 Technical data Dimensions Width 210 mm Height 170 mm Depth 136 mm Ambient conditions Degree of protection IP20 Ambient temperature (operation) 0 C ... 40 C Ambient temperature (storage/transport) -15 C ... 40 C (with charged power storage device) Max. permissible relative humidity (operation) 95 % (25C, non-condensing) Noise immunity Noise immunity according to EN 62040-2-2006 Installation height 3000 mm (> 2000 m, observe derating) Input data Nominal input voltage 230 V AC Input voltage range 184 V AC ... 264 V AC AC frequency range 45 Hz ... 55 Hz Input fuse 10 A 400 V gRL Permissible backup fuse B6 B10 B16 Power factor (cos phi) 0.8 Output data Nominal output voltage 230 V AC Nominal output current (IN) 3A Connection in parallel No Connection in series No General Net weight 5.7 kg Memory medium Lead rechargeable battery module Protection class I MTBF (IEC 61709, SN 29500) > 206000 h (40C) Connection data, input Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 04/14/2017 Page 2 / 6 https://www.phoenixcontact.com/us/products/2905909 Uninterruptible power supply - TRIOUPS-2G/1AC/1AC/230V/750VA - 2905909 Technical data Connection data, input Conductor cross section AWG max. 12 Stripping length 10 mm Connection data, output Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 2.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Stripping length 10 mm Connection data for signaling Connection method Push-in connection Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 1.5 mm Conductor cross section flexible min. 0.2 mm Conductor cross section flexible max. 1.5 mm Conductor cross section AWG min. 24 Conductor cross section AWG max. 16 Stripping length 8 mm Charging process Charging time 7h Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU Shock 20g in all directions (EN 60068-2-27) Noise immunity Noise immunity according to EN 62040-2-2006 Standards/regulations EN 61000-4-2 Contact discharge 4 kV (Test Level 2) Standards/regulations EN 61000-4-3 Frequency range 80 MHz ... 1 GHz Test field strength 10 V/m Standards/regulations EN 61000-4-4 Comments Criterion B Standards/regulations EN 61000-4-5 04/14/2017 Page 3 / 6 https://www.phoenixcontact.com/us/products/2905909 Uninterruptible power supply - TRIOUPS-2G/1AC/1AC/230V/750VA - 2905909 Technical data Standards and Regulations Signal 1 kV (Test Level 2 - asymmetrical) Standards/regulations EN 61000-4-6 Frequency range 0.15 MHz ... 80 MHz Voltage 10 V Standards/regulations EN 61000-4-8 Vibration (operation) 5 Hz ... 100 Hz, 0.7g (EN 60068-2-6) Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC Drawings Block diagram L N PE L N Output PE External energy + storage - Alarm Bat.-Mode Ready Remote Bat.-Start SGnd Input " !C 3,4 Ah 12 V 3,4 Ah 12 V Classifications eCl@ss eCl@ss 5.1 27040603 eCl@ss 6.0 27040603 eCl@ss 8.0 27040602 eCl@ss 9.0 27040705 ETIM ETIM 5.0 EC000382 ETIM 6.0 EC000382 UNSPSC UNSPSC 13.2 39121011 04/14/2017 Page 4 / 6 https://www.phoenixcontact.com/us/products/2905909 Uninterruptible power supply - TRIOUPS-2G/1AC/1AC/230V/750VA - 2905909 Approvals Approvals Approvals IECEE CB Scheme Ex Approvals Approval details IECEE CB Scheme http://www.iecee.org/ DK-56005-M1-UL Accessories Accessories Assembly adapter Assembly adapters - UWA 130 - 2901664 2-piece universal wall adapter for securely mounting the power supply in the event of strong vibrations. The profiles that are screwed onto the side of the power supply are screwed directly onto the mounting surface. The universal wall adapter is attached on the left/right. Battery unit Energy storage - QUINT-BAT/24DC/ 3.4AH - 2866349 Energy storage device, lead AGM, VRLA technology, 24 V DC, 3.4 Ah. Connection via pin cable lug, 14 mm. Data cable preassembled 04/14/2017 Page 5 / 6 https://www.phoenixcontact.com/us/products/2905909 Uninterruptible power supply - TRIOUPS-2G/1AC/1AC/230V/750VA - 2905909 Accessories Data cable - MINI-SCREW-USB-DATACABLE - 2908217 Used for communication between an industrial PC and Phoenix Contact devices with USB-Mini-B connection. Fuse Fuse - FUSE 10A/400V GRL - 2908358 Fuse, nominal current: 10 A, length: 31.8 mm, diameter: 6.35 mm Fuse - FUSE 40A/32V ATOF - 2908357 Fuse, nominal current: 40 A, length: 19 mm, width: 5 mm, height: 18.8 mm Phoenix Contact 2017 (c) - all rights reserved http://www.phoenixcontact.com 04/14/2017 Page 6 / 6