Power Relay 430 3 mm 1 pole 16 A, DC- and AC-coil Features * * * * * * * 1 N/O contact Safety mains isolation Contact gap > 3 mm 4 kV / 8 mm coil-contact, protection class II (VDE 0700) PCB mounting or Faston connectors Mounting brackets or snap mounting Version with arc blow magnet for high DC-loads Applications Domestic appliances, industrial appliances, industrial controls F0256-A VZ C Technical data of approved types on request Configuration Type of contact Rated current Rated voltage / max.breaking voltage AC Maximum breaking capacity AC Make current (max. 4 s at duty cycle 10%) Contact material Contact gap Contact ratings Type Load 430x5 16 A, 250 Vac, resistive, 70 C 430x5 10 A, 250 Vac, resistive, 105 C Coil data Nominal voltage Nominal coil power Edition: 07/2003 Operate category DC coil AC coil DC coil AC coil 1 N/O contact single contact 16 A 250 Vac / 400 Vac 4000 VA 25 A AgCdO, AgCu3 >3 mm Operations 1.5x105 1.5x105 6...110 Vdc 6...240 Vac 1W 1.8 VA 2/b Coil versions, DC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vdc Vdc Vdc Vdc c mA 09 12 7.8 0.6 15.6 145+10% 83.0 10 24 15.6 1.2 31.2 580+10% 41.0 11 48 31.2 2.4 62.4 2200+10% 22.0 13 110 71.5 5.5 143.0 13000+10% 9.0 Coil versions, AC coil Coil Nominal Pull-in Release Maximum Coil Coil code voltage voltage voltage voltage resistance current Vac Vac Vac Vac c mA 23 24 18 3.6 27.0 145+10% 75.0 25 60 45 9.0 69.0 950+10% 30.0 26 110 83 16.0 127.0 3100+10% 16.0 28 240 185 36.0 264.0 13000+10% 8.0 All figures are given for coil without preenergization, at ambient temperature +20C Other coil voltages on request Rights to change data / design reserved Contact data Power Relay 430 3 mm 1 pole 16 A, DC- and AC-coil Insulation Dielectric strength coil-contacts open contact circuit Clearance / creepage Insulation to IEC 60664 Voltage rating Pollution degree Overvoltage category Insulation to VDE 0110b (2/79) Insulation category / reference voltage Tracking resistance of relay base 4000 Vrms 2000 Vrms 8 / 8 mm PCB layout / terminal assignment View on solder pins Dimensions in mm 250 V 3 III C / 250 PTI 380H S0448-AE Other data Ambient temperature Mechanical life Max. switching rate at rated- / minimum load Operate- / release time Bounce time Shock resistance (destruction) Category of protection (IEC 61810) Relay weight Packaging unit Dimensions Dimensions in mm -20...+70 C >2.5x105 operations 15 min-1 / 300 min-1 typ. 15 / 8 ms typ. 4 ms 100 g RT I - dust protected 32 g 50 pcs. S0448-AF Snap mounting Edition: 07/2003 Rights to change data / design S0449-AB S0449-AH Power Relay 430 3 mm 1 pole 16 A, DC- and AC-coil Dimensions Dimensions in mm Mounting brackets DIN-rail mount S0449-AK Rights to change data / design reserved Edition: 07/2003 S0449-AD