Rights to change data / design reserved
Edition: 07/2003
Power Relay 430 3 mm
1 pole 16 A, DC- and AC-coil
Contact data
Configuration 1 N/O contact
Type of contact single contact
Rated current 16 A
Rated voltage / max.breaking voltage AC 250 Vac / 400 Vac
Maximum breaking capacity AC 4000 VA
Make current (max. 4 s at duty cycle 10%) 25 A
Contact material AgCdO, AgCu3
Contact gap >3 mm
Features
•1 N/O contact
•Safety mains isolation
•Contact gap > 3 mm
•4 kV / 8 mm coil-contact, protection class II (VDE 0700)
•PCB mounting or Faston connectors
•Mounting brackets or snap mounting
•Version with arc blow magnet for high DC-loads
Applications
Domestic appliances, industrial appliances, industrial controls
VZ C
Technical data of approved types on request
Contact ratings
Type Load Operations
430x5 16 A, 250 Vac, resistive, 70 °C 1.5x105
430x5 10 A, 250 Vac, resistive, 105 °C 1.5x105
Coil data
Nominal voltage DC coil 6...110 Vdc
AC coil 6...240 Vac
Nominal coil power DC coil 1 W
AC coil 1.8 VA
Operate category 2 / b
Coil versions, DC coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vdc Vdc Vdc Vdc cmA
09 12 7.8 0.6 15.6 145+10% 83.0
10 24 15.6 1.2 31.2 580+10% 41.0
11 48 31.2 2.4 62.4 2200+10% 22.0
13 110 71.5 5.5 143.0 13000+10% 9.0
Coil versions, AC coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vac Vac Vac Vac cmA
23 24 18 3.6 27.0 145+10% 75.0
25 60 45 9.0 69.0 950+10% 30.0
26 110 83 16.0 127.0 3100+10% 16.0
28 240 185 36.0 264.0 13000+10% 8.0
All figures are given for coil without preenergization, at ambient temperature +20°C
Other coil voltages on request
F0256-A