101
Alpha Wire INDUSTRIAL SERIES
TECHNOLOGICALLY ADVANCED CABLE SYSTEMS FOR
AUTOMOTIVE AND INDUSTRIAL FACTORY AUTOMATION
Alpha Wire continues to offer “Powerful Solutions For Critical
Applications” with the introduction of our new Alpha Wire
INDUSTRIAL SERIES product line.
The Alpha Wire INDUSTRIAL SERIES offers
technologically advanced cable systems for automotive and
industrial factory automation. There is an Alpha Wire
INDUSTRIAL SERIES cable product available to solve
most existing critical and severe-duty application requirements.
When it has to be right, when dependability and quality are
paramount, when safety and security are the primary issue,
the UL Exposed Run (-ER) Compliant Alpha Wire
INDUSTRIAL SERIES provides the total solution and sets
the industry standard for performance, quality and reliability.
Specify Alpha Wire INDUSTRIAL SERIES: SERIES F,
SERIES M, SERIES L, SERIES P, SERIES S and SERIES V for
compliance with the 2005 National Electrical Code for cables
installed in industrial establishments.
All Alpha Wire INDUSTRIAL SERIES products are
designed and manufactured in the United States by Alpha’s
exacting team of engineers. If you don’t nd the cable you require
in this catalog, we’ll work with you to design what you need.
. . . . . . . . . . . . . . . . . . . . . . . .
APPLICATIONS
High Flexibility/High Bend Applications
Factory Equipment Interconnects
Robotics
Machine Tools
Automotive Assembly Equipment
Conveyor Systems
Control Panels
Flex and Static Track
Transfer Shuttles
Automated Pick-and-Place Systems
PLC Controlled Equipment
C-Track or Stationary Applications
Automated Handling Systems
Regulation and Measurement of Motor Speeds
and Positions For Use in Servo Motor Systems
Manufactured In The U.S.A.
103
UL TYPE TC-ER 600 VOLT
UL TYPE PLTC OPEN WIRING 300 VOLT
DIRECT BURIAL, SUNLIGHT RESISTANT
RoHS COMPLIANT, UL STANDARD 66 TYPE TFFN
CSA AWM I/IIA/B: 600 VOLT FT-4
CE - LVD 73/68/EEC, AMEND. 93/68/EEC
AVAILABILITY
In Stock: Bulk, Cut to Length
16 (Black Conductors Only) Cables areMade To Order,
1,000 Ft. Minimum, Non-Cancelable, Non-Returnable
18, 14, 12, 10 and 8 AWG Cables Are Made To Order,
1,000 Ft. Minimum, Non-Cancelable, Non-Returnable.
Call Alpha for details.
RED INSULATION – AC Circuits Operating at Less Than Line Voltage
BLUE INSULATION – DC Circuits Operating at Less Than Line Voltage
BLACK INSULATION – AC Circuits Operating at Less Than Line Voltage
FOR COMPLETE SERIES F PRODUCT PERFORMANCE DATA, SEE PAGE 367.
Alpha Wire INDUSTRIAL SERIES
STATIONARY AUTOMOTIVE CONTROL CABLE
MINIMAL FLEX, OIL/CHEMICAL RESISTANT, MULTICONDUCTOR, UNSHIELDED
CHARACTERISTICS
OPERATING TEMPERATURE:
–25°C to 90°C (75°C Wet)
VOLTAGE RATING:
600 Volt
COLOR DESCRIPTION:
Color Code: Red (RW), Blue (LW) or Black (KW) Alpha-Numeric Conductors
White Striped Neutral (>12 Conductors)
Green/Yellow Ground Conductor
Jacket Color: Gray
PRODUCT DESCRIPTION:
Conductor: Class K Stranded Bare Copper
Insulation: Red, Blue or Black PVC/Nylon
Jacket: Specially Formulated Oil Resistant PVC
SPECIFICATIONS
UL Standard 66, Type TFFN PVC/Nylon Conductors
UL Standard 1277, Type TC-ER , 90°C, 600 Volt
UL Standard13, Type PLTC, 90°C, 300 Volt
UL Sunlight Resistant
UL Open Wiring
UL Direct Burial
CSA C22.2 No. 210.2 AWM I/II A/B 90°C, 600 Volt, FT-4
CE Low Voltage Directive: 73/68/EEC
Amendment 93/68/EEC
RoHS Compliant
CHOOSE
SERIES M
FOR
:
Cables Extending From Cable Tray For An Unlimited
Distance UL Type PLTC or UL Type TC
Improved Cable Life
Abrasion Resistance
Reduced Cable Cost
Jacket Durability
Oil Resistance
SERIES M
APPLICATIONS
:
UL Compliant to NEC Section 725.61 (D) (4) and NEC
Section 336.10 (7) For Extended Runs Exiting The Cable Tray
FactoryEquipment
Stationary Track/Tray
Interconnects
Automotive Assembly Equipment
Robotics
Conveyor Systems
Machine Tools
Control Panels
HIGH PERFORMANCE,
STATIONARY AUTOMOTIVE
CONTROL CABLE
THE ULTIMATE CABLE SOLUTION FOR
STATIONARY/CABLE TRAY AND SOME MINIMAL
FLEXING APPLICATIONS WITH SUPERIOR RESISTANCE
TO OILS AND CHEMICALS
MADE IN U.S.A.
16 AWG (1,32mm2), 26/30 BC,Insulation Thickness 0.016" PVC (0,4mm)/0.005" Nylon (0,1mm)
Red Conductors Blue Conductors Black Conductors No. of Primary O.D. Jacket Thickness Nominal Diameter
Alpha Part No. Alpha Part No. Alpha Part No. Cond. Inches mm Inches mm Inches mm
M16103RWM16103LWM16103KW 30.102 2,6 0.050 1,3 0.325 8,3
M16104RWM16104LWM16104KW 40.102 2,6 0.050 1,3 0.350 8,9
M16105RW M16105LW M16105KW 5 0.102 2,6 0.050 1,3 0.380 9,7
M16107RW M16107LW M16107KW 7 0.102 2,6 0.050 1,3 0.410 10,4
M16112RW M16112LW M16112KW 12 0.102 2,6 0.065 1,7 0.575 14,6
M16117RWM16117LWM16117KW 17 0.102 2,6 0.065 1,7 0.645 16,4
M16119RW M16119LW M16119KW 19 0.102 2,6 0.065 1,7 0.644 16,3
M16122RW M16122LW M16122KW 22 0.102 2,6 0.065 1,7 0.705 17,9
M16125RW M16125LW M16125KW 25 0.102 2,6 0.065 1,7 0.760 19,3
M16133RWM16133LW M16133KW 33 0.102 2,6 0.085 2,2 0.855 21,7
M16142RWM16142LWM16142KW 42 0.102 2,6 0.085 2,2 0.950 24,1
M16149RWM16149LWM16149KW 49 0.102 2,6 0.085 2,2 1.005 25,5
M16165RW M16165LW M16165KW 65 0.102 2,6 0.085 2,2 1.120 28,4
FIT
®TUBING RECOMMENDATION
FIT
®221 General Purpose, Irradiated Polyolefin
(See Pages 114,115 for Product Specifications)
FIT
®-321 Medium Wall, Adhesive Lined, Irradiated Polyolefin
(See Page 121 for Product Specifications)
®
®