DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 IEC Appliance Inlet C14 with Filter, Line Switch 1- or 2-pole, Front or Rear Side Mounting Screw-on mounting from front side C14 Snap-in version from front side Screw-on mounting from front side, protection class II C18 See below: Approvals and Compliances 70 C 70 C Description - Panel mount : Screw-on version from front or rear side, snap-in version from front side - 3 Functions : Appliance Inlet protection class I or II , Line Switch 1 or 2pole , Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm Unique Selling Proposition - Characteristics - Compact design with optimal shielding Rear side mounting for efficient costsaving assembly - All single elements are already wired - Line switch non-illuminated or illuminated - Universal line filter for standard applications - Ideal for application with high transient loads - Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Other versions on request Compact power entry module Available in white or black Switch for high inrush current V-Lock cord retaining - Solder terminals - Other rocker marking - Capacitance CX1 References Alternative: version without line filter DC11 Substitute for type KFB1;KFB2 Weblinks pdf data sheet, html data sheet, General Product Information, Distributor-Stock-Check, Accessories, Detailed request for product, Landing Page Newly available variants corresponding to V-Lock mating cordset. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temperature Climatic Category IP-Protection Protection Class Terminal Panel Thickness S Material: Housing 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 10 A @ Ta 40 C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -25 C to 85 C 25/085/21 acc. to IEC 60068-1 from front side IP40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw: max 8 mm Mounting screw torque max 0.5 Nm Snap-in: 1 mm to 3 mm Thermoplastic, black / white, UL 94V-0 appliance inlet/-outlet Line Switch Line Filter MTBF C14 / C18 acc. to IEC 60320-1, UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 C, 10 A, Protection Class I or II Rocker switch 1 or 2 pole, non-illuminated or illuminated, acc. to IEC 61058-1 Technical Details Standard and Medical Version, IEC 60939, UL 1283, CSA C22.2 no. 8 Technical Details > 1'900'000 h acc. to MIL-HB-217 F Approvals and Compliances EMC Products 1 DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Detailed information on product approvals, code requirements, usage instructions and detailed test conditions can be looked up in Details about Approvals SCHURTER products are designed for use in industrial environments. They have approvals from independent testing bodies according to national and international standards. Products with specific characteristics and requirements such as required in the automotive sector according to IATF 16949, medical technology according to ISO 13485 or in the aerospace industry can be offered exclusively with customer-specific, individual agreements by SCHURTER. Approvals The approval mark is used by the testing authorities to certify compliance with the safety requirements placed on electronic products. Approval Reference Type: DC12 Approval Logo Certificates Certification Body Description VDE Approvals VDE Certificate Number: 40001522 UL Approvals UL UL File Number: E72928 CQC Approvals CQC CQC Certificate Number: CQC18001188116 Design Standard Description Designed according to IEC 60320-1 Appliance couplers for household and similar general purposes Designed according to IEC 60939 Passive filters for suppressing electromagnetic interference Designed according to IEC 61058-1 Switches for appliances. Part 1. General requirements Designed according to UL 498 Standard for Attachment Plugs and Receptacles Designed according to UL 1283 Electromagnetic interference filters Designed according to CSA C22.2 no. 42 General Use Receptacles, Attachment Plugs, and Similar Wiring Devices Designed according to CSA C22.2 no. 8 Electromagnetic interference (EMI) filters Design Standard Description Designed for applications acc. IEC/UL 60950 IEC 60950-1 includes the basic requirements for the safety of information technology equipment. Designed for applications acc. IEC 60601-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Details Initiator Description CE declaration of conformity SCHURTER AG The CE marking declares that the product complies with the applicable requirements laid down in the harmonisation of Community legislation on its affixing in accordance with EU Regulation 765/2008. RoHS SCHURTER AG Directive RoHS 2011/65/EU, Amendment (EU) 2015/836 China RoHS SCHURTER AG The law SJ / T 11363-2006 (China RoHS) has been in force since 1 March 2007. It is similar to the EU directive RoHS. REACH SCHURTER AG On 1 June 2007, Regulation (EC) No 1907/2006 on the Registration, Evaluation, Authorization and Restriction of Chemicals 1 (abbreviated as "REACH") entered into force. SCHURTER AG V-Lock system are based on a matching plug-dose combination. The connector is equipped with a notch intended for use with the latching cordset. The cord latching system prevents against accidental removal of the cordset. SCHURTER AG Suitable for use in medical equipment according to IEC/UL 60601-1 Product standards Product standards that are referenced Organization Application standards Application standards where the product can be used Organization Compliances The product complies with following Guide Lines Identification Medical Equipment 2 EMC Products DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Dimension [mm] Screw-on mounting from front side 27.2 3 R 2.5 36 0.15 1.6 36 33.1 0.10 3.6/M3 32.70 x28.5 34.4 31.2 R6 3.2 6.3x90 R4 9.5 46 44.3 29.10.10 5 R 3.0 60.5 Screw-On Version from rear side (metal flange) 34.4 3.6 32.6 x28.5 0.10 36 0.15 R4 2.65 9.5 31.2 R4 M3 34 2.2 R5 36.5 27.2 R 2.5 30 9.5 36 4.2 46.8 30.4 0.10 R4 60.5 44.3 Snap-in mounting from front side 3 R 5.5 30 32.5 2.65 32.70 x28.5 9.5 31.2 33.1 0.10 R 2.5 34 27.2 36.5 R4 9.5 46 5 +0.10 29.4 - 0.05 R 3.0 60.5 EMC Products 3 DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Screw-on mounting from front side (protection class II) 27.2 3 R 2.5 36 0.15 1.6 36 8 46 44.3 33.1 0.10 3.6/M3 32.70 x28.5 34.4 31.2 R6 3.2 6.3x90 R4 29.10.10 5 R 3.0 59 Screw-on version from rear side (protection class II) 34.4 3.6 32.6 x28.5 0.10 36 0.15 R4 2.65 9.5 31.2 R4 M3 34 2.2 R5 36.5 27.2 R 2.5 30 8 36 4.2 46.8 30.4 0.10 59 44.3 Snap-in mounting from front side (protection class II) 3 R 5.5 30 2.65 32.70 x28.5 9.5 31.2 33.1 0.10 R 2.5 34 27.2 36.5 R4 46 59 32.5 4 8 EMC Products 5 +0.10 29.4 - 0.05 R 3.0 R4 DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [M] 1 Standard Version 2 x 10 100 2.2 1 2 Standard Version 2x4 100 2.2 1 4 Standard Version 2 x 1.5 100 2.2 1 6 Standard Version 2 x 0.8 100 2.2 1 10 Standard Version 2 x 0.3 100 2.2 1 1 Medical Version (M5) 2 x 10 100 - 1 2 Medical Version (M5) 2x4 100 - 1 4 Medical Version (M5) 2 x 1.5 100 - 1 1 6 Medical Version (M5) 2 x 0.8 100 - 10 Medical Version (M5) 2 x 0.3 100 - 1 1 Medical Version (M80) 2 x 10 100 0.47 1 2 Medical Version (M80) 2x4 100 0.47 1 4 Medical Version (M80) 2 x 1.5 100 0.47 1 6 Medical Version (M80) 2 x 0.8 100 0.47 1 10 Medical Version (M80) 2 x 0.3 100 0.47 1 EMC Products 5 DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Diagrams Standard filter 1-pole Standard filter 2-pole L L' L1 1) PE R Cy Cx L2 Cy N L 2) 1) PE PE' N' 1) Line 2) Load Medical filter 1-pole (M5) Medical filter 2-pole (M5) L L' L1 PE R 1) Line 2) Load Standard filter 2-pole illuminated Medical Filter 2-pole (M5) illuminated L' L1 Cy PE Cx L2 Cy N N' N Medical filter 2-pole (M5) protection class II L' L1 R Cx 2) L2 N' N 1) Line 2) Load 6 EMC Products Cx 2) PE' L2 N' L' L1 1) Line 2) Load L R 1) PE PE' N' L' L 2) 1) Line 2) Load 1) Cy N 1) Line 2) Load L L2 2) PE' L1 PE N' 1) Cx 1) L2 N Cy L 2) PE' Cx R N 1) Line 2) Load 1) L' L1 Cx 2) PE' L2 N' DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Attenuation Loss - - - - 50 differential mode _____ 50 common mode Standard version 1A 2A 4A 6A 2A 4A 6A 10 A Medical version (M5) 1A 10 A All Variants Rated current Filter-Type Panel mounting Mounting side Line Switch Illumination Color Protection V-Lock Order Number 1 Standard Version Snap-in Front Side 1-pole non-illuminated black I l DC12.1102.103 2 Standard Version Snap-in Front Side 1-pole non-illuminated black I l DC12.2102.103 4 Standard Version Snap-in Front Side 1-pole non-illuminated black I l DC12.3102.103 6 Standard Version Snap-in Front Side 1-pole non-illuminated black I l DC12.4102.103 10 Standard Version Snap-in Front Side 1-pole non-illuminated black I l DC12.5102.103 1 Standard Version Snap-in Front Side 2-pole non-illuminated black I l DC12.1102.101 2 Standard Version Snap-in Front Side 2-pole non-illuminated black I l DC12.2102.101 4 Standard Version Snap-in Front Side 2-pole non-illuminated black I l DC12.3102.101 6 Standard Version Snap-in Front Side 2-pole non-illuminated black I l DC12.4102.101 10 Standard Version Snap-in Front Side 2-pole non-illuminated black I l DC12.5102.101 1 Standard Version Screw Front Side 1-pole non-illuminated black I l DC12.1102.003 2 Standard Version Screw Front Side 1-pole non-illuminated black I l DC12.2102.003 4 Standard Version Screw Front Side 1-pole non-illuminated black I l DC12.3102.003 EMC Products 7 DC12 Rated current Power Entry Modules with Line Filter https://www.schurter.com /PG06 Filter-Type Panel mounting Mounting side Line Switch Illumination Color Protection V-Lock Order Number 6 Standard Version Screw Front Side 1-pole non-illuminated black I l DC12.4102.003 10 Standard Version Screw Front Side 1-pole non-illuminated black I l DC12.5102.003 1 Standard Version Screw Front Side 2-pole non-illuminated black I l DC12.1102.001 2 Standard Version Screw Front Side 2-pole non-illuminated black I l DC12.2102.001 4 Standard Version Screw Front Side 2-pole non-illuminated black I l DC12.3102.001 6 Standard Version Screw Front Side 2-pole non-illuminated black I l DC12.4102.001 10 Standard Version Screw Front Side 2-pole non-illuminated black I l DC12.5102.001 1 Standard Version Screw Rear Side 1-pole non-illuminated black I l DC12.1102.203 2 Standard Version Screw Rear Side 1-pole non-illuminated black I l DC12.2102.203 4 Standard Version Screw Rear Side 1-pole non-illuminated black I l DC12.3102.203 6 Standard Version Screw Rear Side 1-pole non-illuminated black I l DC12.4102.203 10 Standard Version Screw Rear Side 1-pole non-illuminated black I l DC12.5102.203 1 Standard Version Screw Rear Side 2-pole non-illuminated black I l DC12.1102.201 2 Standard Version Screw Rear Side 2-pole non-illuminated black I l DC12.2102.201 4 Standard Version Screw Rear Side 2-pole non-illuminated black I l DC12.3102.201 6 Standard Version Screw Rear Side 2-pole non-illuminated black I l DC12.4102.201 10 Standard Version Screw Rear Side 2-pole non-illuminated black I l DC12.5102.201 1 Medical Version (M5) Snap-in Front Side 1-pole non-illuminated black I l DC12.1202.103 2 Medical Version (M5) Snap-in Front Side 1-pole non-illuminated black I l DC12.2202.103 4 Medical Version (M5) Snap-in Front Side 1-pole non-illuminated black I l DC12.3202.103 6 Medical Version (M5) Snap-in Front Side 1-pole non-illuminated black I l DC12.4202.103 10 Medical Version (M5) Snap-in Front Side 1-pole non-illuminated black I l DC12.5202.103 DC12.1202.101 1 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black I l 1 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black II l DC12.1202.121 1 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated white II l DC12.1202.131 2 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black I l DC12.2202.101 2 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black II l DC12.2202.121 2 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated white II l DC12.2202.131 4 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black I l DC12.3202.101 4 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black II l DC12.3202.121 4 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated white II l DC12.3202.131 6 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black I l DC12.4202.101 6 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black II l DC12.4202.121 6 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated white II l DC12.4202.131 10 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black I l DC12.5202.101 10 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated black II l DC12.5202.121 10 Medical Version (M5) Snap-in Front Side 2-pole non-illuminated white II l DC12.5202.131 6 Medical Version (M5) Snap-in Front Side 2-pole illuminated green black I l DC12.4232.101 1 Medical Version (M5) Screw Front Side 1-pole non-illuminated black I l DC12.1202.003 2 Medical Version (M5) Screw Front Side 1-pole non-illuminated black I l DC12.2202.003 4 Medical Version (M5) Screw Front Side 1-pole non-illuminated black I l DC12.3202.003 6 Medical Version (M5) Screw Front Side 1-pole non-illuminated black I l DC12.4202.003 10 Medical Version (M5) Screw Front Side 1-pole non-illuminated black I l DC12.5202.003 1 Medical Version (M5) Screw Front Side 2-pole non-illuminated black I l DC12.1202.001 1 Medical Version (M5) Screw Front Side 2-pole non-illuminated black II l DC12.1202.021 1 Medical Version (M5) Screw Front Side 2-pole non-illuminated white II l DC12.1202.031 2 Medical Version (M5) Screw Front Side 2-pole non-illuminated black I l DC12.2202.001 8 EMC Products DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Rated current Filter-Type Panel mounting Mounting side Line Switch Illumination Color Protection V-Lock Order Number 2 Medical Version (M5) Screw Front Side 2-pole non-illuminated black II l DC12.2202.021 2 Medical Version (M5) Screw Front Side 2-pole non-illuminated white II l DC12.2202.031 4 Medical Version (M5) Screw Front Side 2-pole non-illuminated black I l DC12.3202.001 4 Medical Version (M5) Screw Front Side 2-pole non-illuminated black II l DC12.3202.021 4 Medical Version (M5) Screw Front Side 2-pole non-illuminated white II l DC12.3202.031 6 Medical Version (M5) Screw Front Side 2-pole non-illuminated black I l DC12.4202.001 6 Medical Version (M5) Screw Front Side 2-pole non-illuminated black II l DC12.4202.021 6 Medical Version (M5) Screw Front Side 2-pole non-illuminated white II l DC12.4202.031 10 Medical Version (M5) Screw Front Side 2-pole non-illuminated black I l DC12.5202.001 10 Medical Version (M5) Screw Front Side 2-pole non-illuminated black II l DC12.5202.021 10 Medical Version (M5) Screw Front Side 2-pole non-illuminated white II l DC12.5202.031 1 Medical Version (M5) Screw Rear Side 2-pole non-illuminated black I l DC12.1202.201 2 Medical Version (M5) Screw Rear Side 2-pole non-illuminated black I l DC12.2202.201 DC12.3202.201 4 Medical Version (M5) Screw Rear Side 2-pole non-illuminated black I l 6 Medical Version (M5) Screw Rear Side 2-pole non-illuminated black I l DC12.4202.201 10 Medical Version (M5) Screw Rear Side 2-pole non-illuminated black I l DC12.5202.201 1 Medical Version (M80) Screw Rear Side 2-pole non-illuminated black I l DC12.1602.201 2 Medical Version (M80) Screw Rear Side 2-pole non-illuminated black I l DC12.2602.201 4 Medical Version (M80) Screw Rear Side 2-pole non-illuminated black I l DC12.3602.201 6 Medical Version (M80) Screw Rear Side 2-pole non-illuminated black I l DC12.4602.201 10 Medical Version (M80) Screw Rear Side 2-pole non-illuminated black I l DC12.5602.201 Most Popular. Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 10 Pcs Accessories Description Wire Harness Wire harness for SCHURTER products Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001 Countersunk, B 4700.0002 EMC Products 9 DC12 Power Entry Modules with Line Filter https://www.schurter.com /PG06 Mating Outlets/Connectors Category / Description Connector Overview complete 4782 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4782 4785 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4781 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C15 4781 4784 Mounting: Power Cord, 3 x 1 mm / 3 x 18 AWG, Cable, Connector: IEC C15 4784 Connector further types to DC12 Interconnection Cord Overview complete Cord Sets 10 A, Interconnection, 1.0 m, Connector IEC C13, H05VV-F3G1.0, black 6007.0212 Cord Sets 10 A, Interconnection, 2.0 m, Connector IEC C13, H05VV-F3G1.0, black 6007.0214 Interconnection Cord further types to DC12 Power Supply Cord Overview complete Cord Sets 10 A, Europlug, 2.0 m, Connector IEC C13, H05VV-F3G0.75, black 6004.0114 Cord Sets 10 A, Europlug, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black 6004.0215 Cord Sets 10 A, Europlug, 2.5 m, Connector IEC C13, H05VV-F3G1.0, black 6003.0215 Cord Sets 10 A, Europlug, Black, 2.5 m, H05VV-F 3G1,0mm2, Connector IEC C13, 002500 mm, H05VV-F3G1.0, black 6004.0225 Cord Sets 10 A, diverse, Black, 5.0 m, H05VV-F 3G1,0mm2, Connector IEC C13, 002500 mm, H05VV-F3G1.0, black 6052.0026 Power Supply Cord further types to DC12 ... Mating Outlets/Connectors shuttered Power Cord Overview complete VAC13KS, Overview, V-Lock cord retaining, diverse Connector IEC C13, diverse, black VAC13KS VAC17KS, V-Lock cord retaining, diverse m, Connector IEC C17, diverse, black / grey / white VAC17KS 21.03.2019 Power Cord further types to DC12 10 EMC Products The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.