WLP350 Industrial Features l 5 x 3 x 1 Inches Form factor l 350 Watts with Forced Air Cooling & 200 Watts Convection Cooling l l Efficiencies upto 94% -40 to 70 degree operating temperature* l 12V / 0.5A Fan Output, Thermal Shut-Down feature l 2.56m Hours, Telcordia -SR332-issue 3 MTBF l Standby Power < 0.5W l Approved to EN60950-1 2nd Edition Electrical Specifications Input Voltage Input Frequency Input Current No Load Power Inrush Current Leakage Current Efficiency Hold-up Time Power Factor Output Power Output Voltage Adjustability Line Regulation Load Regulation Transient Response Rise Time Set Point Tolerance Over Current Protection Over Voltage Protection Short Circuit Protection Switching Frequency Operating Temperature Storage Temperature Relative Humidity Altitude MTBF Isolation Voltage Cooling 90-264 VAC/390 VDC, Universal (Derate from 100% at 100V AC to 90% at 90V AC) 47-63 Hz 115 VAC: 3.6 A max. 230 VAC: 1.8 A max. less than 0.5W typical 115 VAC - 25 A, 230 VAC - 45 A, 264 VAC - 75 A 300 uA Typical 94%(48V,58V), 93%(24V,30V), 92%(12V,15V) Full Load > 8 ms typical Convection Load > 14 ms typical exceeds 0.95 with Full Load upto 350W with 375 LFM, upto 200W Convection +/-3% +/-0.5% +/-1% 50-100% step load change, at 0.1A/uS slew rate, 50% duty cycle, 50Hz=5% , recovery time < 5 ms 55 ms typical +/-1% >110% ,Hiccup mode / Auto Recovery 110 to 140% , Hiccup mode / Auto Recovery Hiccup mode / Auto Recovery PFC - 70 to 130 KHz ,PWM - 50-80 KHz -40 to +70C, * -40 to 0C startup is guaranteed with spec deviation (ref note 6) -40 to +85C 5% to 95%, noncondensing Operating: 16,000 ft.; Nonoperating: 40,000 ft. 2.56m Hours, Telcordia -SR332-issue 3 Input to Output - 3000V AC for ITE application Input to GND - 1500 VAC 350W with 375 LFM forced air cooling at 100 to 264VAC 200W with natural convection cooling at 100 to 264VAC. 7 4EM-17-174 39-DE60-47150-002 / D5 Model Number Description LFWLP350-1001 with Screw Terminal LFWLP350-13017 with Molex Connector LFWLP350-1002 with Screw Terminal LFWLP350-13027 with Molex Connector LFWLP350-1003 with Screw Terminal LFWLP350-1303 with Molex Connector LFWLP350-1004 with Screw Terminal LFWLP350-1304 with Molex Connector LFWLP350-1005 with Screw Terminal LFWLP350-1305 with Molex Connector LFWLP350-1006 with Screw Terminal LFWLP350-1306 with Molex Connector LFWLP350-CK metal cover kit accessory Max. Load Max. Load (Convection) (375 LFM) Voltage Min. Load Ripple1 12V 15A 25A 0.0A 1% 12V 15A 18.75A 15V 15V 24V 24V 48V 48V 30V 30V 58V 58V 12A 12A 8.33A 8.33A 4.17A 4.17A 6.67A 6.67A 3.45A 3.45A 21.67A 18A 14.60A 14.60A 7.30A 7.30A 11.67A 11.67A 6.04A 6.04A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 0.04 0.0A 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% Connectors J1 J2 Option 1 (Screw Terminal) J2 Option 2 (Molex Connector) J3 Pin 1 Pin 2 Pin 3 Pin 1 Pin 2 Pin 1,2,3,4 Pin 5,6,7,8 Pin 1 Pin 2 AC LINE NOT FITTED AC NEUTRAL V1 +VE V1 -VE V1 +VE V1 -VE FAN +VE FAN -VE Notes 1. Ripple is peak to peak with 20 MHz bandwidth and 10 F (Tantalum capacitor) in parallel with a 0.1 F capacitor at rated line voltage and load ranges. 2. Combined output power of main output, fan supply shall not exceed max. Power rating. 3. Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-10% and Ripple and noise is less than 10%. 4. Specifications are for nominal input voltage, 25C unless otherwise stated. 5. Thermal shutdown feature : The power supply goes in hiccup mode when the temperature of PCB exceeds 110 C (+/-10 C). 6. Output ripple can be more than 10% of the output voltage. 7. Models LFWLP350-1301 and LFWLP350-1302 do not have CCC approval 8. When used in Cover Kit, de-rate output power to 70 % under all operating conditions 2 Innovations in Power 4EM-17-174 39-DE60-47150-002 / D5 Mechanical Specifications AC Input Connector (J1) Earth (J4) DC Output Connector (J2) Option 1 (Screw Terminal) DC Output Connector (J2) Option 2 (Molex Connector) Aux (Fan) Output(J3) Dimensions Weight Molex: 26-60-4030 Mating: 09-50-3031; Pins: 08-50-0106 Molex: 19705-4301 Mating: 19003-0001 6-32 inches Screw Pan HD Mating: Designed to accept Ring Tongue Terminal AMP : 8-31886-1, wherein one 16 AWG(max) wire can be crimped. Note : One Ring Tongue Terminal with 16 AWG is recommended for current upto 11A only. Use multiple tongue terminals with wire for more current. Molex: 26-60-4080 Mating: 09-50-3081; Pins: 08-50-0106 AMP :640456-2 Mating: 640440-2 5 x 3 x 1 inches (127 x 76.2x 25.4 mm) 300 gm approx EMC Parameter Conducted Emissions Radiated Emissions Conditions/Description EN55032-B, CISPR22-B, FCC PART15-B EN 55032 A Input Current Harmonics Voltage Fluctuation and Flicker ESD Immunity Radiated Field Immunity Electrical Fast Transient Immunity Surge Immunity Conducted Immunity Magnetic Field Immunity Voltage dips, interruptions EN 61000-3-2 EN 61000-3-3 EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 Criteria Pass Pass Level B with external core (King core K5B RC 25x12x15-M in input cable) Class D Pass Level 3, Criterion A Level 3, Criterion A Level 3, Criterion A Level 3, Criterion A Level 3, Criterion A Level 3, Criterion A Criterion A & B Safety CE Mark Complies with LVD Directive Approval Agency Safety Standard(s) Nemko, UL, C-UL, CCC EN60950-1, IEC60950-1 (ed.2) , UL 60950 (ed.2), CSA C22.2 No.60950-1 (ed.2), Class1 SELV , GB4943. 1-2011 ; GB9254-2008 ; GB17625. 1-2012 Class-I : UL: Certificate Number 20150122-E150565,Nemko: Certificate No. P15219422, CB Certificate No.: NO85161 Class-II : Nemko: Certificate No. P15219457,CB Certificate No.: NO85356 Safety File Number(s) 9 4EM-17-174 39-DE60-47150-002 / D5 Derating Curve Convection load: 180W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load : 300W up to 50C De-rate above 50 C @ 2.5% per C Convection load: 180W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load : 325W up to 50C De-rate above 50 C @ 2.5% per C Convection load: 200W up to 50 C De-rate above 50 C @ 2.5% per C Forced air cooled load : 350W up to 50C De-rate above 50 C @ 2.5% per C Derating Curve Note : Between -40 to 0C startup is guaranteed with spec deviation ( ref note 6) 4 Innovations in Power 4EM-17-174 39-DE60-47150-002 / D5 Mechanical Drawing Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following 1. Stand off, used to mount PCB has OD of 5.4 mm max. 2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3. Washer, if used, to have dia of 6.5 mm max. Notes: In case the PCB is mounted in a metal enclosure, using metal hardware ensure the following 1. Stand off, used to mount PCB has OD of 5.4 mm max. 2. Screws, used to fix PCB on stand off, have head dia of 6.0 mm max. 3. Washer, if used, to have dia of 6.5 mm max. 11 4EM-17-174 39-DE60-47150-002 / D5