A623308 Series
PRELIMINARY (December, 2002, Version 0.3) 3 AMIC Technology, Corp.
Recommended DC Operating Conditions
(TA = 0°C to +70°C, -25°C to +85°C or -40°C to +85°C)
Symbol Parameter Min. Typ. Max. Unit
VCC Supply Voltage 4.5 5.0 5.5 V
GND Ground 0 0 0 V
VIH Input High Voltage 2.2 3.5 VCC + 0.3 V
VIL Input Low Voltage -0.3 0 +0.8 V
Absolute Maximum Ratings*
VCC to GND . . . . . . . . . . . . . . . . . . . . . -0.5V to +7.0V
IN, IN/OUT Volt to GND . . . . . . . . . -0.5V to VCC + 0.5V
Operating Temperature, Topr . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . 0°C to +70°C or -40°C to +85°C
Storage Temperature, Tstg . . . . . . . . . -55°C to +125°C
Power Dissipation, PT . . . . . . . . . . . . . . . . . . . . . 0.7W
Soldering Temp. & Time . . . . . . . . . . . . . 260°C, 10 sec
*Comments
Stresses above those listed under "Absolute Maximum
Ratings" may cause permanent damage to the device.
These are stress ratings only. Functional operation of this
device at these or any other conditions above those
indicated in the operational sections of this specification
is not implied and exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
DC Electrical Characteristics (TA = 0°C to +70°C, -25°C to +85°C or -40°C to +85°C, VCC = 5.0V ± 10%, GND = 0V)
Symbol Parameter A623308-70S A623308-70SI/SU Unit Conditions
Min. Max. Min. Max.
ILI Input Leakage
Current - 1 - 1 µA VIN = GND to VCC
ILO Output Leakage
Current - 1 - 1 µA CE = VIH or OE = VIH or
WE = VIH
VI/O = GND to VCC
ICC Active Power
Supply Current - 5 - 5 mA CE = VIL, II/O = 0mA
ICC1 Dynamic
Operating Current - 35 - 35 mA Min. Cycle, Duty = 100%
CE = VIL, II/O = 0mA
ICC2 Dynamic
Operating Current
- 5
- 5
mA CE = VIL, VIH = VCC
VIL = 0V, f = 1 MHz
II/O = 0 mA