Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition: • 15.04.2004
Subject to change without notice • © Hans Turck GmbH & Co.KG 2002 • Edition:
Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264
Inductive sensor
with extended switching distance
Bi2-EG08-AP6X-H1341
●threaded barrel, M8 x 1
●stainless steel, 1.4301
●extended switching distance
●3-wire DC, 10...30 VDC
●normally open pnp output
●connector, M12 x 1
Wiring diagram
Function principles
Inductive proximity switches are designed
for wear-free non-contact detection of me-
tal objects. For this they use a high-fre-
quency electro-magnetic AC field that
interacts with the target. With conventional
inductive sensors, this field is generated by
an LC resonant circuit with a ferrite core
coil.
1 BN
3 BU
4 BK
+
pnp
4 BK
3 BU 1 BN
2
Type Bi2-EG08-AP6X-H1341
Ident-No. 4602060
Rated operating distance Sn 2 mm
Mounting mode flush
Hysteresis (switching distance) 3... 15 %
Min. repeat accuracy ≤ 2 %
Temperature drift ≤ ± 10 %
Operating temperature -25 ...+ 70 °C
Rated operational voltage (DC) UB10... 30 VDC
Max. ripple ≤ 10 % Upp
Rated operational current (DC) Ie≤ 150 mA
No-load current I0≤ 15 mA
Max. OFF-state current ≤ 0,1 mA
Max. switching frequency ≤ 3 kHz
Rated insulation voltage ≤ 0,5 kV
Output function 3-wire, normally open, PNP
Short-circuit protection yes, cyclic
Max. voltage drop at Ie≤ 1,8 V
Wire breakage / reverse polarity protection yes / complete
Housing style threaded barrel; M8 x 1
Dimensions 57 mm
Housing material metal, A2 1.4301 (AISI 304)
Active face plastic, PA12-GF20
Max. fixing torque of coupling nut 10 Nm
Wiring connector, M12 x 1
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 x g (11 ms)
Degree of protection IP67
Switching status indication LED yellow
13/4
40
LED
M8 x 1
M12 x 1
57