1197 FIBER SENSORS Compact Fan Type Ionizer ER-Q SERIES Related Information High-frequency AC Method General terms and conditions.............. F-7 Glossary of terms.......................... P.1497 Selection guide............................ P.1157~ General precautions...................... P.1501 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS SUNXpanasonic.net/id/pidsx/global website http://www.sunx.com MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Spot charge removal without compressed air Miniature, ultralight, fast charge removal A perfect fit for installation in other devices. * Dimensions: W65 x H60 x D33 mm W2.559 x H2.362 x D1.299 in * Net weight: 110 g approx. * Charge removal Time ( 1,000 V 100 V): 1.5 sec approx. (typical) Adjustable Includes volume adjuster to change fan blowing to meet your needs. Selection Guide Static Removers Cleaning Box Pulse Air-gun Electrostatic Sensor ER-X ER-TF ER-VS02 Safe design Freely mounted: No air hoses necessary The LED display and output indicate maintenance timing and problems with the fan. Mountable like a sensor in cell workbenches or inside devices. Simple maintenance Assembled and disassembled in a single touch, reducing steps required to replace parts or clean filters. ER-VW ER-Q ER-F ER-QMS1 Discharge needle unit Filter MS-AJ1-A Compact Fan Type Ionizer ER-Q SERIES 1198 APPLICATIONS FIBER SENSORS Removing dust on tape before taping Prevention of part feeder clogging Prevention of misalignment at crimping LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS ORDER GUIDE Type SENSOR OPTIONS Change removal time (1,000V100V) Appearance Ion balance Model No. SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Compact fan type 1.5 sec. approx. (Note) 10 V or less (Note) ER-Q MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS Note: Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed. PLC HUMAN MACHINE INTERFACES OPTIONS ENERGY CONSUMPTION VISUALIZATION COMPONENTS Designation Model No. Description FA COMPONENTS ER-QMS1 The ER-Q mounting bracket. Adjust the air output direction. MACHINE VISION SYSTEMS ER-QCC2 Length 2 m 6.562 ft ER-QCC5 UV CURING SYSTEMS Length 5 m 16.404 ft AC adapter ER-VAPS1 * IN: 100 to 240 V AC, 50 / 60 Hz, 40 VA * OUT: 24 V DC, 750 mA * Ambient temperature: 0 to +40 C +32 to +104 F Discharge needle unit ER-QANT Unit with tungsten needles (1 pc.) Air filter ER-QFX5 Fan intake filter (5 pcs. per set) Mounting bracket Connector-attached cable * 0.13 mm2 8-core connector cabtyre cable * Cable outer diameter: o3.7 mm o0.146 in CHARGE REMOVAL CHARACTERISTICS (TYPICAL) CPM L W(Horizontal) 100 200 300 400 3.937 7.874 11.811 15.748 Charge removal distance L (mm in) Charge removal width H (mm in) Charge removal width W (mm in) Charge removal field Charge removal field (horizontal direction) (vertical direction) (Fan speed MAX., filter is mounted) (Fan speed MAX., filter is mounted) 2 sec. 5 sec. 10 sec. 500 19.685 200 7.874 150 5.906 100 3.937 50 1.969 0 0 -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 0 0 CPM L H(Vertical) 100 200 300 400 3.937 7.874 11.811 15.748 Charge removal distance L (mm in) Static Removers PRECAUTIONS FOR PROPER USE Refer to p.1501 for general precautions. * Measured using a 150 mm x 150 mm 5.906 in x 5.906 in CPM (charge plate monitor). (At center of CPM) 200 7.874 150 5.906 100 3.937 50 1.969 0 0 -50 -1.969 -100 -3.937 -150 -5.906 -200 -7.874 0 0 Selection Guide 2 sec. 5 sec. 10 sec. 500 19.685 * Never use this product in a device for personnel protection. * In case of using devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. * Do not use this product in places where there may be a danger of flammable or combustible items being present. Cleaning Box Pulse Air-gun Electrostatic Sensor ER-X ER-TF ER-VS02 ER-VW ER-Q ER-F 1199 Compact Fan Type Ionizer ER-Q SERIES SPECIFICATIONS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Compact fan type Type Item ER-Q Model No. 1.5 sec. approx. (Note 2) Charge removal time (1,000 V 100 V) 10 V or less (Note 2) Ion balance Power supply voltage 24 V DC 10% Power consumption 200 mA or less High-frequency AC method Discharge method 2 kV approx. Discharge output voltage Max. fan speed 6.4 m/s (Note 2) Max. fan volume 0.2 m3/min. NPN transistor / open collector * Max sink current: 50 mA * Applied voltage: 30 V DC or less (between output terminal and 0 V) * Residual voltage: 1 V or less (at input current of 50 mA) Output(CHECK, ALARM) SIMPLE WIRE-SAVING UNITS Check: On when discharge check (Note 3) detected Off at all other times Error: O ff when discharge error or fan error (Note 3) detected On at all other times Output operation WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS Incorporated Short-circuit protection Discharge (DSC): Green LED, Alarm (ALARM): Red LED Indicators 0.02 ppm or less (Note 2) Ozone generation amount 0 to +50 C +32 to +122 F (No dew condensation), Storage: -10 to +65 C +14 to +149 F Ambient temperature 35 to 65% RH (No dew condensation), Storage: 35 to 65% RH Ambient humidity 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Vibration resistance C (capacitor) grounding Grounding method Material Enclosure: PBT, Discharge needle: Tungsten Weight Net weight: 110 g approx. Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08P), Terminal (5556T)] Accessory Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed. 3) Discharge check: Drop in discharging status detected. Discharge error: Abnormal discharge detected. Fan error: Fan operating problem detected. UV CURING SYSTEMS I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Connector terminal No. Selection Guide Static Removers D1 5 Cleaning Box Main circuit ER-X ER-TF D2 Tr1 7 8 7 6 5 (+) 4 3 2 1 D3 Tr2 (Orange) Check output Load (Front view) 50 mA max. ZD1 ZD2 ER-VS02 1 2 ER-Q 4 Internal circuit + (Black) Error output 8 Load 50 mA max. + ER-VW ER-F Color code (Brown) +24 V 6 COM Pulse Air-gun Electrostatic Sensor Connector terminal arrangement (Blue) 0 V - - 30 V DC max. COM (-) (Green) F.G. User's circuit Symbols ... D1: Reverse supply polarity protection diode D2, D3: Input protection diode ZD1, ZD2, : Surge absorption zener diode Tr1, Tr2, : NPN output transistor 24V DC 10 % Terminal No. Description Color code 1 0V Blue 2 COM (-) 3 N.C. (no connection) 4 F.G. Green 5 +24 V Brown 6 COM (+) 7 Check output Orange 8 Error output Black 5 59 8 83 Compact Fan Type Ionizer DIMENSIONS (Unit: mm in) 1200 The CAD data in the dimensions can be downloaded from our website. ER-Q Ionizer main unit 2-o3.5 o1.378 mounting hole AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS Discharge indicator (Green) 60 2.362 PRESSURE / FLOW SENSORS Power switch INDUCTIVE PROXIMITY SENSORS 5.5 Filter cover o3.7 o0.146 cable 0.5 m 1.64 ft 2-o3.5 o1.378 mounting hole Fan speed control PARTICULAR USE SENSORS 29 1.142 33 1.299 Connector 5559-08P manufactured by Molex SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS 2-M3 screws (depth 10 0.394) (Note) WIRE-SAVING SYSTEMS Alarm indicator (Red) Note: S crew threads exclusive for mounting brackets. Do not use them in mounting with other products. When mounting this product directly to a case or such, fix it with M3 screws using 2-o3.5 o1.378 mounting holes. 25.4 1.000 Discharge indicator (Green) Power switch 19.8 0.780 5.5 0.217 over 29 1.142 33 1.299 ER-QMS1 Mounting bracket (Optional) Assembly dimensions 60 2.362 25.4 1 2-o3.3 0.130 5.5 0.217 ( ( 83 3.268 60 2.362 19.6 0.772 16.5 0.650 54 2.216 48 1.890 t 1.2 t 0.047 40 50 56 1.575 1.969 2.205 M4x8 0.315 Airflow direction adjustment screw STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS UV CURING SYSTEMS 48 1.890 4-o4.5 0.177 MEASUREMENT SENSORS MACHINE VISION SYSTEMS 16.5 0.650 M3x10 0.394 32.5 (1.280 ) 50 1.969 60 Selection Guide Static Removers 8.6 (0.339 ) o46 40 50 56 1.575 1.969 2.205 Cleaning Box Pulse Air-gun Electrostatic Sensor 4.2 0.165 o46 65 (2.560 ) M4x8 0.315 Airflow direction adjustment screw 83 (3.268 ) 72 2.835 50 1.969 60 ) ) 34.2 (1.346 ) 30.2 (1.189) 42 1.654 19 0.748 4-o4.5 0.177 LASER SENSORS MICRO PHOTOELECTRIC 2-M3 screws (depth 10 0.394) (Note) SENSORS Fan speed control Alarm indicator (Red) 52 2.047 Discharge needle unit FIBER SENSORS PHOTOELECTRIC SENSORS 65 2.559 58 2.283 3.5 0.138 3.5 0.138 Ion air outlet m 1.64 ft r 5559-08P ured by Molex ER-Q SERIES ER-X ER-TF ER-VS02 ER-VW ER-Q 4.2 0.165 ER-F 0.21