1197
Related Information
Selection
Guide
Static
Removers
Cleaning Box
Pulse Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Miniature, ultralight, fast charge removal
A perfect t for installation in other devices.
Adjustable
Includes volume adjuster to change fan blowing to meet
your needs.
Safe design
The LED display and output indicate maintenance timing
and problems with the fan.
Simple maintenance
Assembled and disassembled in a single touch, reducing
steps required to replace parts or clean lters.
Freely mounted: No air hoses necessary
Mountable like a sensor in cell workbenches or inside
devices.
ER-Q SERIES
Spot charge removal without compressed air
Compact Fan Type Ionizer High-frequency AC Method
General terms and conditions ............. F-7 Selection guide ........................... P.1157~
Glossary of terms.......................... P.1497 General precautions ..................... P.1501
http://www.sunx.com
SUNX website
ER-QMS1 MS-AJ1-A
Discharge needle unit
Filter
Conforming to
EMC Directive
panasonic.net/id/pidsx/global
Dimensions: W65 × H60 × D33 mm
W2.559 × H2.362 × D1.299 in
Net weight: 110 g approx.
Charge rem oval Time (± 1,000 V ± 100 V):
1.5 sec approx. (typical)
1198
Compact Fan Type Ionizer ER-Q SERIES
Selection
Guide
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
PRECAUTIONS FOR PROPER USE
Type Appearance Change removal time
(±1,000V→±100V) Ion balance Model No.
Compact fan type 1.5 sec. approx. (Note) ±10 V or less (Note) ER-Q
ORDER GUIDE
Designation Model No. Description
Mounting bracket ER-QMS1 The ER-Q mounting bracket. Adjust the air output direction.
Connector-attached cable
ER-QCC2 Length 2 m 6.562 ft
0.13 mm
2
8-core connector cabtyre cable
Cable outer diameter: ø3.7 mm ø0.146 in
ER-QCC5 Length 5 m 16.404 ft
AC adapter ER-VAPS1
• IN: 100 to 240 V AC, 50 / 60 Hz, 40 VA
• OUT: 24 V DC, 750 mA
• Ambient temperature: 0 to +40 °C +32 to +104 °F
Discharge needle unit ER-QANT Unit with tungsten needles (1 pc.)
Air lter ER-QFX5 Fan intake lter (5 pcs. per set)
Note: Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no lter installed.
OPTIONS
Prevention of part feeder clogging
Removing dust on tape before taping
Prevention of misalignment at crimping
APPLICATIONS
Never use this product in a device for
personnel protection.
In case of using devices for personnel
protection, use products which meet laws
and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in
each region or country.
Do not use this product in places where
there may be a danger of ammable or
combustible items being present.
Refer to p.1501 for general precautions.
Measured using a 150 mm × 150 mm 5.906 in × 5.906 in
CPM (charge plate monitor). (At center of CPM)
0
0
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
-200
-7.874
-150
-5.906
-100
-3.937
-50
-1.969
0
0
50
1.969
100
3.937
150
5.906
200
7.874
Charge removal distance L (mm in)
2 sec.
5 sec.
10 sec.
Charge removal field
(horizontal direction)
(Fan speed MAX., filter is mounted)
Charge removal width W (mm in)
L
W(Horizontal)
CPM
Charge removal width H (mm in)
0
0
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
-200
-7.874
-150
-5.906
-100
-3.937
-50
-1.969
0
0
50
1.969
100
3.937
150
5.906
200
7.874
Charge removal field
(vertical direction)
(Fan speed MAX., filter is mounted)
Charge removal distance L (mm in)
CPM
LH(Vertical)
2 sec.
5 sec.
10 sec.
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
1199
Compact Fan Type Ionizer ER-Q SERIES
Selection
Guide
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Type Compact fan type
Item Model No. ER-Q
Charge removal time (±1,000 V → ±100 V) 1.5 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 2)
Power supply voltage 24 V DC ±10%
Power consumption 200 mA or less
Discharge method High-frequency AC method
Discharge output voltage ±2 kV approx.
Max. fan speed 6.4 m/s (Note 2)
Max. fan volume 0.2 m3/min.
Output(CHECK, ALARM)
NPN transistor / open collector
Max sink current: 50 mA
Applied voltage: 30 V DC or less (between output terminal and 0 V)
Residual voltage: 1 V or less (at input current of 50 mA)
Output operation
Check: On when discharge check (Note 3) detected
Off at all other times
Error: Off when discharge error or fan error (Note 3) detected
On at all other times
Short-circuit protection Incorporated
Indicators Discharge (DSC): Green LED, Alarm (ALARM): Red LED
Ozone generation amount 0.02 ppm or less (Note 2)
Ambient temperature 0 to +50 °C +32 to +122 °F (No dew condensation), Storage: –10 to +65 °C +14 to +149 °F
Ambient humidity 35 to 65% RH (No dew condensation), Storage: 35 to 65% RH
Vibration resistance
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z
directions for two hours each
Grounding method C (capacitor) grounding
Material Enclosure: PBT, Discharge needle: Tungsten
Weight Net weight: 110 g approx.
Accessory
Connector for wiring: 1 set
[Manufactured by Molex: Housing (5557-08P), Terminal (5556T)]
SPECIFICATIONS
Terminal
No.
Description Color code
10 V Blue
2COM (–)
3
N.C. (no connection)
4F.G. Green
5+24 V Brown
6COM (+)
7Check output Orange
8Error output Black
(Front view)
5678
1234
(Brown) +24 V
(Orange) Check output
(Blue) 0 V
COM (+)
(Black) Error output
(Green) F.G.
COM ()
Main circuit
ZD1
ZD2
Tr1
D1
Tr2
D3
D2
30 V DC max.
+
Load
Load
1
8
7
6
5
2
4
Color code
Connector terminal No.
50 mA max.
50 mA max.
Internal circuit User’s circuit
24V DC
±10 %
+
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram Connector terminal arrangement
Symbols … D1: Reverse supply polarity protection diode
D2, D3: Input protection diode
ZD1, ZD2, : Surge absorption zener diode
Tr1, Tr2, : NPN output transistor
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no lter installed.
3) Discharge check: Drop in discharging status detected. Discharge error: Abnormal discharge detected. Fan error: Fan operating problem detected.
1200
Compact Fan Type Ionizer ER-Q SERIES
Selection
Guide
Static
Removers
Cleaning
Box
Pulse
Air-gun
Electrostatic
Sensor
ER-X
ER-TF
ER-VS02
ER-VW
ER-Q
ER-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
ELECTRICITY
PREVENTION
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
ER-Q
Fan speed control
Ion air outlet
Discharge needle unit
29
1.142
33
1.299
Filter cover
Alarm indicator (Red)
Discharge indicator
(Green)
Power switch
Connector 5559-08P
manufactured by Molex
2-ø3.5 ø1.378
mounting hole
ø3.7 ø0.146 cable 0.5 m 1.64 ft
3.5
0.138
3.5
0.138
52
2.047
65
2.559
58
2.283
60
2.362
2-M3 screws (depth 10 0.394) (Note)
5.5
0.217
25.4
1.000
19.8
0.780
Fan speed control
Ion air outlet
Discharge needle unit
29
1.142
33
1.299
Filter cover
Alarm indicator (Red)
Discharge indicator
(Green)
Power switch
Connector 5559-08P
manufactured by Molex
2-ø3.5 ø1.378
mounting hole
ø3.7 ø0.146 cable 0.5 m 1.64 ft
3.5
0.138
3.5
0.138
52
2.047
65
2.559
58
2.283
60
2.362
2-M3 screws (depth 10 0.394) (Note)
5.5
0.217
25.4
1.000
19.8
0.780
DIMENSIONS (Unit: mm in)The CAD data in the dimensions can be downloaded from our website.
Note: Screw threads exclusive for mounting
brackets. Do not use them in mounting
with other products.
When mounting this product directly to a
case or such, x it with M3 screws using
2-ø3.5 ø1.378 mounting holes.
Ionizer main unit
ER-QMS1 Mounting bracket (Optional)
2-ø3.3 0.130
4-ø4.5 0.177
50
1.969
60°
48
1.890
54
2.216
19.6
0.772
25.4
1
5.5
0.217
16.5
0.650
60
2.362
83
(
3.268
)
8.6
(
0.339
)
ø46
19
0.748
42
1.654
M4×8 0.315
Airflow direction
adjustment screw
4.2
0.165
56
2.205
40
1.575
50
1.969
72
2.835
t 1.2
t 0.047
48
1.890
16.5
0.650
60
(
2.362
)
34.2
(
1.346
)
30.2
(
1.189
)
83
(
3.268
)
65
(
2.560
)
32.5
(
1.280
)
M4×8 0.315
Airflow direction
adjustment screw
M3×10 0.394
4-ø4.5 0.177
50
1.969
60°
40
1.575
50
1.969
56
2.205
ø46
4.2
0.165