Product Specification
G64128X01 series
CrystalClearTechnologysdn.bhd.
16JalanTP5—TamanPerindustrianSimeUEP
47600SubangJaya—SelangorDE
Malaysia.T:+60380247099F:+60380247098
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
1
1.0 Table of Contents
Page
1. Table of Contents 1
2. Record of revision 2
3. General specification 3
4. Absolute maximum ratings 4
5. Electrical characteristics 4
6. Environmental requirement 4
7. LCD specification 5 ~ 7
8. Interface 8
9. Functional Description 9 ~ 10
10. Instructions 11
11. Block Diagram and Power Supply 12
12. Quality assurance 13 ~ 14
13. Precautions in use LCM 15 ~ 16
14. Outline drawing 17
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
2
2.0 Record of revision
Rev Date Item Page Comment Originator Checked By
1.0
2.0
15/09/08
17/07/12
Initial Release
Change Vlcd Value
Update backlight lifetime
information
Syam
Azhar
Azhar
Azhar
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
3
3.0 General specification
Display format: Graphics 128 (w) x 64 (h) dots
Dot size: 0.49 (w) x 0.49 (h) mm
Dot pitch: 0.52 (w) x 0.52 (h) mm
View area: 70.7 (w) x 38.8 (h) mm
Active area: 66.53 (w) x 33.25 (h) mm
General dimensions: 93.0 (w) x 70.0 (h) x 13.5 max (t) mm
Controller/Driver: NT7107 and NT7108 or equivalent
Interface: Parallel
Driving method: 1/64 duty, 1/9 bias
00 - STANDARD SPECIFICATION MODEL
REFER TO FACTORY FOR OTHER VERSIONS. TERMS AND CONDITIONS APPLY
W : Wide Temperature ( -20°C to +70°C ), where storage temperature is (-30°C to +80°C)
N : Normal Temperature ( 0°C to +50°C ), where storage temperature is (-20°C to +70°C)
SERIES NUMBER FOR THIS STANDARD SPECIFICATION
SEMI - CUSTOMISE (MINOR CHANGES FROM STANDARD MODEL)
Y : Yellow Green (STN)
G : Grey (STN)
B : Black & White (FSTN)
N : Negative (FSTN) Blue ( Single Retardation )
U : Negative (FSTN) Black/White ( Double Retardation )
S : Negative (STN)
Z : Negative (FSTN) Black/White ( Double Retardation ) TRI-AXIS
MODULE VERSION
LCD MODE
VIEWING ANGLE
OPERATING TEMPERATURE
T : Top view ( 12 O'clock )
B : Bottom view ( 6 O'clock )
SERIES NUMBER FOR THIS STANDARD SPECIFICATION
8
L : Bottom Led Backlight (Yellow Green)
R : Bottom Led Backlight (Red)
W : Side Led Backlight (White)
N : No Backl ight
STD. GRAPHIC : No. of rows followed by no. of column
BACKLIGHT MODE
MODEL NUMBER
G6 21
410 0 0
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
4
4.0 Absolute maximum rating (at Vss = 0V, ambient temperature = 25°C)
NO ITEM SIMBOL MIN MAX UNIT
1. Power Supply Voltage (Logic) VDD - VSS 0 7.0 V
2. Power Supply Voltage (LCD Driver) VDD – V0 - 14.0 V
3. Operating Temperature Top Refer page 3 °C
4. Storage Temperature Tst Refer page 3 °C
5.0 Electrical characteristics
NO ITEM SYMBOL CONDITION MIN TYP MAX UNI
T
1. Power Supply
Voltage (Logic) VDD – VSS - 4.5 5.0 5.5 V
2. Power Supply
Voltage (VLCD) VDD-V0 25°C 11.5±5% V
VIH 0.7VDD - VDD
3. Input Voltage VIL - 0 - 0.3VDD V
4. Current Supply IDD
VDD - VSS =
5V
VDD – V0 =
11.5V
- 15 - mA
5.1 Backlight Options
FORWARD VOLT A GE
(V) F ORWA RD CU R REN T
(mA)
NO COLOR
Min Typ. Max Min Typ. Max
MIN
BRIGHTNESS
(cd/m2) *
1. Yellow Green - 5.0 - - 100 160 40
2. White - 5.0 - - 45 60 200
3. Red - 5.0 - - 110 160 60
*Note: 1. Brightness measured at backlight surface.
2. On LCD surface, brightness is only about 10% to 15% of backlight brightness.
3. Lifetime of backlight: For YG, Red = 50K hrs. For White = 10K hrs
4. Lifetime of backlight is defined as decay time for backlight brightness to become
50% of original brightness.
6.0 Environmental requirements
NO ITEM CONDITION
1. Operating Temperature Refer page 3
2. Storage Temperature Refer page 3
3. Operating Humidity 5% to 95%RH
4. Cycle Test 0 C @ 30 min to 50 C @ 30min for 1 cycle
run for 10 cycles
5. Lifetime 50000 HOURS (excluding backlight)
Note: The background on LCD has the possibility to be changed in different temperature range.
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
5
7.0 LCD specification
7.1 Electro-optical characteristics (at ambient temperature = 25°C)
LCD TYPE
UNIT
NO ITEM SYMBOL CONDITION STN
YG STN
GREY
STN
-VE
BLUE
FSTN
+VE
B/W
FSTN
–VE
BLUE
FSTN -
VE
TRUE
B/W
FSTN
-VE
TRI
AXIS
REF.
1
Operating
Voltage
(Volt)
VLCD θ = 0
Cr = max 11.5 ± 5% 7.1.1
θ x 1 +25 +20 +35 +25 +35 +35 +40
θ x 2 -25 -20 -35 -25 -35 -40 -40
θ y 1 -30 -25 -35 -30 -35 -35 -50
2
Viewing
Angle
(Deg)
θ y 2
CR 2
VLCD =
11.5V +30 +25 +35 +30 +35 +35 +30
7.1.2
3 Contrast
Ratio CR
θ = 00
VLCD
=11.5V
3.0 2.3 6.0 3.0 6.0 20 20 7.1.3
Rise
Time
(Tr)
θ = 00 200
4
Response
Time
(msec) Decay
Time
(Td)
θ = 00 250
7.1.4
Note:
1. Viewing angle data is based on bottom view product by default. Should it be a
top view product, values are then swap.
2. Contrast ratio is based on typical data when using white colour as backlight.
3. Equipment Used Eldim; Ez Contrast 120R , Spot Size = 2mm
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
6
NO CHARACTERISTICS DEFINITIONS
7.1.1
Definition of Operating
Voltage (VLCD)
VLCD
1/F
VLCD : Operating Voltage
F : Frame Frequency
7.1.2
Definition of Viewing
Angle
TOP
θ REAR
LEFT RIGHT
FRONT
BOTTOM
REAR (θy2)
LEFT(θx2) RIGHT(θx1)
FRONT (θy1)
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
7
7.1.3
Definition of Contrast
Ratio
NON-SELECT WAVE
BRIGHTNESS (%)
SELECT WAVE
b
a
OPERATION VOLTAGE
Contrast Ratio = Brightness of non-selected state (b)
Brightness of selected state (a)
Conditions
(a) Operating Voltage: VLCD
(b) Temperature: 25°C
(c) Viewing Angle, θ = 0o
7.1.4
Response Time
Luminance
(%)
90
10
Tr: Measured between 10% and 90% of LCD segment
maximum response with VON.
Td: With voltage switches to zero and the instant LCD
segment reaches 10% of its maximum response.
Td
Tr
Time
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
8
8.0 Interface
8.1 Controller NT7107
8.2 Display Driver NT7108
8.3 Duty Cycle 1/64
8.4 Pin-out Assignments
Pin No Symbol Description
1 VSS Ground terminal of module
2 VDD Supply terminal of module
3 VO Power supply for Liquid Crystal Drive
4 RS Register select signal
5 R/W Read/Write selection:
High = Read
Low = Write
6 E Enable signal
7 to 14 D0 to D7 Bi-directional Data Bus. Data transfer is performed
once, thru D0 to D7, in the case of interface data
length is 8-bits.
15 CS1 Select IC U2 (active high)
16 CS2 Select IC U3 (active high)
17 RSTB Reset signal (active low)
18 VOUT* Negative voltage from the LCD Module
19 SLA Backlight power supply
20 SLK Backlight ground
Note:
VOUT*: The module will generate its own negative volt age.
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
9
9.0 Functional Descriptions
9.1 Display Control Timing Waveform and Characteristics
9.2 MPU Timing
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
10
MPU Write Timing
MPU Read Timing
9.3 Timing Diagram (1/64 Duty)
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
11
10. Instruction Set
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
12
11. Block Diagram and Power Supply
LCD PANEL
LED BACKLIGHT
CS2
CS1
D0 t o D7
RS
R/W
E
RSTB
VDD
VS S
V OUT
VO
SLA
SLK
LCD POWER /
CONVE RT E R
UNI T
SE GME NT DR IVER
SEGMENT DRIVER
64 S EG. 64 SEG.
CO MMON
DRIVER
64 CO M.
Block Diagram
5V
10KΩ-20KΩ
5V
Power Supply
LED BACKLIGHT
VDD
VSS
VOUT
Vo
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
13
12.0 Quality Assurance
12.1 ZONE DEFINITION
12.1.1 Black Spot, White Spot and Foreign Material
Defect
Category Defect Description Criterion Drawing Specification
Zone / Acceptable No.
Dimension A B C
D < 0.10mm NC NC NC
0.10<D < 0.20mm 3 3 NC
0.20 < D < 0.30mm 1 2 NC
D > 0.30 mm 0 0 NC
NC: No count
Black Spot,
White Spot
and Foreign
Material
Black Spot, White
Spot and Foreign
Material
D: Mean Diameter of Defect
12.1.2 Line Shape and Scratches
Defect
Category Defect Description Criterion Drawing Specification
Zone /Dimension Acceptable No.
X Y A B C
- <0.01mm
NC NC NC
< 2 mm
< 0.02mm
1 1 NC
<1 mm
< 0.0 2mm
1 2 NC
Line shape
and scratches
Line shape and
scratches
12.1.3 Pin Hole
Defect
Category
Defect Description Criterion Drawing Specification
Pin Hole Pin hole / void at
light up segment D < 0.20mm within 1 part/segment
A
B
D = (A + B)/2
A
B
D = (A + B)/2
EFFECTIVE VIEWING AREA
ZONE A
ZONE B
(Outside Viewing Area)
ZONE C
(Sealing Area)
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
14
12.1.4 Polarizer Bubble/Foreign Material
Defect
Category
Defect Description Criterion Drawing Specification
Zone / Acceptable No.
Dimension A B C
D 0.15mm NC NC NC
0.15 < D 0.30mm 3 5 NC
0.30 < D 0.50mm 2 3 NC
0.50 < D 1.0mm 0 1 NC
NC: No count
D: Mean Diameter of Defect
Polarizer bubble /
Foreign material
Accept - if air bubble at the seal area does
not propagate into effective viewing area
Note: Total defects shall not exceed five
A
B
D = (A + B)/2
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
15
13. Precaution for using LCM
1. Liquid Crystal Display (LCD)
LCD is made up of glass, organic sealant, organic fluid and
polymer based polarizers. The following precautions should
be taken when handling.
b) Keep the temperature within the range of use and
storage. Excessive temperature and humidity
could cause polarization degredation, polarizer
peel off or bubble.
c) Do not contact the exposed polarizer with
anything harder than HB pencil lead. To clean
dust off the display surface, wipe gently with
cotton, chamois or other soft material soaked in
petroleum benzin.
d) Wipe off saliva or water drops immediately.
Contact with water over a long period of time
may cause polarizer deformation or colour
fading, while an active LCD with water
condensation on its surface will cause corrosion
of ITO electrodes.
e) Glass can be easily chipped or cracked from
rough handling, especially at corners and edges.
f) Do not drive LCD with DC voltage.
2. Liquid Crystal Display Modules.
2.1 Mechanical Considerations
LCM are assembled and adjusted with a high
degree of precision. Avoid excessive shocks and
do not make any alterations or modification. The
following should be noted.
a) Do not tamper in any way with the tabs
on the metal frame.
b) Do not modify the PCB by drilling
extra holes, changing its outline,
moving its component or modifying its
pattern.
c) Do not touch the elastomer connector,
especially insert a backlight panel (for
example, EL)
d) When mounting a LCM make sure that
the PCB is not under any stress such as
bending or twisting. Elastomer contacts
are very delicate and missing pixels
could result from slight dislocation of
any of the elements.
a) Avoid pressing on the metal bezel,
otherwise the elastomer connector
could be deformed and lose contact,
resulting in missing pixels.
2.2 Static Electricity
LCM contains CMOS LSI’s and the same
precaution for such devices should apply, namely
a) The operator should be grounded whenever
he/she comes into contact with the module.
Never touch any of the conductive parts
such as the LSI pads, the copper leads on the
PCB and the interface terminals with any
parts of the human body.
b) The modules should be kept in antistatic
bags or other containers to static for storage.
c) Only properly grounded soldering irons
should be used.
d) If an electric screwdriver is used, it should
be well grounded and shielded from
commutator spark.
e) The normal static prevention measures
should be observed for work clothes and
working benches, the latter conductive
(rubber) mat is recommended.
f) Since dry air is inductive to statics, a relative
humidity of 50-60% is recommended.
2.3 Soldering
a) Solder only to the I/O terminals.
b) Use only soldering irons with proper
grounding and no leakage.
c) Soldering temperature: 280 °C
d) Soldering time: 3 to 4 sec
e) Use eutectic solder with resin flux fill.
f) If flux is used, the LCD surface should be
covered to avoid flux spatters. Flux residue
should be removed afterwards.
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
16
2.4 Operation
a) The contras can be adjusted by varying the
LCD driving voltage V0
b) Driving voltage should be kept within
specified range, excess voltage shortens
display life.
c) Response time increases with decrease in
temperature.
d) Display may turn black or dark blue at
temperature above its operational range, this
is (however not pressing on the viewing
area) may cause the segments to appear
“fractured”.
e) Mechanical disturbance during operation (
such as pressing on the viewing area) may
cause the segments to appear “fractured”.
2.5 Storage
If any fluid leaks out of the damage glass cell,
wash off any human part that comes into contact
with soap and water. Never swallow the fluid.
The toxicity is extremely low but caution should
be exercised at all the time.
2.6 Limited Warranty
Unless otherwise agreed between Crystal Clear
Technology and customer, Crystal Clear
Technology will replace or repair any of its LCD
and LCM which is found to be defective
electrically and visually when inspected in
accordance with Crystal Clear Technology
acceptance standards, for a period of one year
from date of shipment. Confirmation of such date
shall be based on freight documents. The
warranty liability of Crystal Clear Technology is
limited to repair and/or replacement on the terms
set forth above. Crystal Clear Technology will
not responsible for any subsequent or
consequential events.
CRYSTAL CLEAR TECHNOLOGY SDN. BHD.
Spec. No: G64128x01xxx00 REV 2.0
17
6
H
E
B
5
4
APPROVED
16, JLN TP5, TMN PERINDUSTRIAN SIME UEP,
7
Crystal−Clear Technology
8
NTS
CHECKED
MODEL NAME
9
1
10 11
MATERIAL
DRAWING NUMBER SHEET H
G
F
D
A
0.49
0.52
0.49
0.52
BACKLIGHT
CrystalClearTechnology
16JalanTP5—TamanPerindustrianSimeUEP
47600SubangJaya—SelangorDE
Malaysia