Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6504FE Multi-Conductor - Commercial Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Plenum-CMP, 6-22 AWG stranded bare copper conductors with Flamarrest(R) insulation, Beldfoil(R) shield and Flamarrest(R) jacket with ripcord Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 6 22 7 BC - Bare Copper Total Number of Conductors: 6 Insulation Insulation Material: Insulation Trade Name Insulation Material Flamarrest(R) Wall Thickness (mm) LS PVC - Low Smoke Polyvinyl Chloride 0.229 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 24 Solid Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Trade Name Outer Jacket Material Flamarrest(R) Nom. Wall Thickness (mm) LS PVC - Low Smoke Polyvinyl Chloride 0.381 Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Color Code Chart: Color Black Red White Green Brown Blue Overall Nominal Diameter: 4.445 mm Mechanical Characteristics (Overall) Installation Temperature Range: 0C To +75C Operating Temperature Range: -10C To +75C Bulk Cable Weight: 36.312 Kg/Km Max. Recommended Pulling Tension: 267.337 N Min. Bend Radius/Minor Axis: 45.720 mm Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6504FE Multi-Conductor - Commercial Applications Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: NFPA 262 CSA Flame Test: FT6 Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): Yes Non-Plenum Number: 5504FE Electrical Characteristics (Overall) Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 108.273 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 193.579 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 53.1522 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 50.1993 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Description Current 10C Temperature Rise 2 Amps per conductor @ 25C ambient Put Ups and Colors: Item # Putup Ship Weight Color 6504FE 004U1000 305 MT 11.793 KG YELLOW 6 #22 FLRST FS FLRST 6504FE 0041000 305 MT 11.793 KG YELLOW 6 #22 FLRST FS FLRST 6504FE 0071000 305 MT 11.793 KG VIOLET 6 #22 FLRST FS FLRST 6504FE 877C500 152 MT 5.443 KG NATURAL 6 #22 FLRST FS FLRST Page 2 of 3 Notes Item Desc 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 6504FE Multi-Conductor - Commercial Applications 6504FE 877U1000 305 MT 11.793 KG NATURAL 6 #22 FLRST FS FLRST 6504FE 877U250 76 MT 3.289 KG NATURAL 6 #22 FLRST FS FLRST 6504FE 877U500 152 MT 6.124 KG NATURAL 6504FE 8771000 305 MT 11.793 KG NATURAL C 6 #22 FLRST FS FLRST 6504FE 877500 152 MT 6.124 KG NATURAL C 6 #22 FLRST FS FLRST 6 #22 FLRST FS FLRST Notes: C = CRATE REEL PUT-UP. Revision Number: 2 Revision Date: 08-16-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013