57
RoHS
Compliant
Rated voltage 760 VAC 50/60 Hz (ENEC)
600 VAC 50/60 Hz (UL, CSA)
Capacitance range 0.01 – 1.0 µF
Capacitance tolerance ± 20% standard, ± 10% option
Temperature range –40 to +105°C
Climatic category 40/105/56/B
Approvals ENEC, UL, cUL
Dissipation factor Maximum values at +23°C
C 0.1 µF 0.1µF < C 1 µF
1 kHz 0.1% 0.1%
10 kHz 0.2% 0.4%
100 kHz 0.6%
Test voltage between The 100% screening factory test is carried out at 4250
terminals VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
Insulation resistance C 0.33 µF: 30 000 M
C > 0.33 µF: 10 000 s
In DC application Recommended voltage:1500VDC
pHE845
EMI suppressor, class X1, metallized polypropylene
0.01 – 1.0 µF, 760 VAC/600 VAC, +105°C
tYpiCaL appLiCations ConstRuCtion
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
Triple winding of metallized polypropylene.
Encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
EnViRonmEntaL tEst data
Endurance EN/IEC 60384-14:2005 1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration IEC 60068–2–6 3 directions at 2 hours each, No visible damage
Test Fc 10–55 Hz at 0.75 mm or 98 m/s2 No open or short circuit
Bump IEC 60068–2–29 1000 bumps at No visible damage
Test Eb 390 m/s2 No open or short circuit
Change of temperature IEC 60068–2–14 Upper and lower rated No visible damage
Test Na temperature 5 cycles
Active flammability EN/IEC 60384-14:2005
Passive flammability EN/IEC 60384-14:2005 Enclosure material of
UL1414 UL94V–0 flammability class
Humidity IEC 60068-2-3 +40°C and 56 days
Test Ca 90 – 95% R.H.
p d std l max l b
22.5 ± 0.4 0.8 6 30 ±0.4
27.5 ± 0.4 0.8 6 30 ±0.4
37.5 ± 0.5 1.0 6 30 ±0.7
Tolerance in lead length
< 30 mm mm
30 mm mm
+0
–1
+5
–0
L
H
B
pl
d
0.5
b
tECHniCaL data
Not for use in series with the mains.
See www.kemet.com for more information.
aRtiCLE taBLE
LEAD SPACING 22.5 MM
0.010 D13 6.5 14.5 26.0 11 100 PHE845VD5100MR06L2
0.015 D13 6.5 14.5 26.0 9.2 100 PHE845VD5150MR06L2
0.022 D13 6.5 14.5 26.0 7.6 100 PHE845VD5220MR06L2
0.033 D17 7.0 16.5 26.0 6.4 100 PHE845VD5330MR06L2
0.047 D15 9.0 18.5 26.0 5.3 100 PHE845VD5470MR06L2
0.068 D18 10.5 19.0 26.0 4.4 100 PHE845VD5680MR06L2
0.10 D16 11.0 21.5 26.0 3.5 100 PHE845VD6100MR06L2
0.15 D20 13.5 23.0 26.0 3.1 100 PHE845VD6150MR06L2
0.22 D19 15.5 24.5 26.0 2.7 100 PHE845VY6220MR06L2*
LEAD SPACING 27.5 MM
0.10 F11 10.5 20.5 31.5 3.4 100 PHE845VF6100MR06L2
0.15 F12 11.5 22.5 31.5 3.0 100 PHE845VF6150MR06L2
0.22 F03 13.5 23.0 31.5 2.4 100 PHE845VF6220MR06L2
0.33 F15 19.0 29.0 31.5 2.0 100 PHE845VF6330MR06L2
0.47 F16 21.0 30.0 31.5 1.6 100 PHE845VZ6470MR06L2*
LEAD SPACING 37.5 MM
0.47 R04 15.0 26.0 41.0 1.6 100 PHE845VW6470MR06L2*
0.47 R02 16.5 32.0 41.0 1.6 100 PHE845VR6470MR06L2
0.68 R03 19.0 36.0 41.0 1.2 100 PHE845VR6680MR06L2
1.0 R06 21.0 38.0 41.0 1.0 100 PHE845VW7100MR06L2*
* Only ±20%
appRoVaLs
Certification Body Specification
ENEC EN/IEC 60384-14:2005
UL UL 1283 (UR=600 VAC)
cUL recognition C 22.2 No. 8 (UR=600 VAC)
oRdERing inFoRmation
maRKing
RIFA
RIFA article code
Rated capacitance
Capacitance tolerance code
Rated voltage
X1
Approval marks
Manufacturing date code
IEC climatic category
Passive flammability class
PHE845
The article code for the standard part is given in the article table.
For other options, see page 11.
Capaci- Box Max dimensions Max
tance code in mm fO dU/dt Article code
µF B H L MHz V/µs
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute
and we specifically disclaim any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.