F-SERIES RFI SUPPRESSION FOR SINGLE PHASE POWER REGULATORS F-RFI X10229 INTRODUCTION Phase-angle power controllers generate Radio Frequency Interference (RFI) during each half-cycle of the mains waveform when the power is switched on. In sensitive applications this interference, or interaction with other equipment, must be suppressed to comply with the Electromagnetic Compatibility Regulations 1992 (SI 1992 No.2372). Appropriate suppression may be achieved by the addition of a series choke and capacitor network incorporated in a filter module. The F-type series filter modules have been manufactured to complement the UAL range of phase angle power controllers. INSTALLATION RoHS Compliant Directive 2002/95/EC CE MARKING This product range is CE marked and may be used as a type filter for CSR, QVR, AVR, FC11AL2, STOM1 and other phase angle applications with appropriate matching current capability, e.g. Stacks and Firing circuits. For classification of type filter refer to products family Declaration of Conformity. The standard filter units comply with the industrial emission levels BS EN 55022 Class A. Max current Choke Induction L1 Order Code Dimensions in MM Terminals 3A 900H F155-3A W44 x L72 x H45 x FC64 1/4 Amp Tag 6A 635H F155-6A W44 x L72 x H45 x FC64 1/4 Amp Tag 10A 330H F155-10A W44 x L72 x H45 x FC64 1/4 Amp Tag 15A 250H F165-15A W62 x L92 x H45 x FC80 M4 stud & nut 25A 200H F175-25A W75 x L105 x H45 x FC64 M4 stud & nut VOLTAGE RANGE 110v TO 230v AC +/- 10% @ 50/60Hz MAXIMUM OPERATING TEMPERATURE 70 c HIGHER CURRENT AND VOLTAGE RATINGS AVAILABLE ON REQUEST UNITED AUTOMATION LIMITED 1Southport Business Park Kew Southport, PR8 4HQ ENGLAND Page No. 1 of 1 Issue 3 Tel: 0044 (0) 1704 516500 Main Tel: 0044 (0) 1704 516516 Sales Fax: 0044 (0) 1704 516501 Enquiry@united-automation.com www.united-automation.com Date 05/11/99 This document was created with Win2PDF available at http://www.daneprairie.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only.