LPF-60D 60W Single Output Switching Power Supply E1/2 E E E E E E E E E E E E E F 110 M M IP67 SELV series Features : Universal AC input / Full range (up to 305VAC) Built-in active PFC function High efficiency up to 90% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Fully isolated plastic case Fully encapsulated with IP67 level (Note.6) Class power unit, no FG Class 2 power unit Built-in 3 in 1 dimming function (1~10Vdc or PWM signal or resistance) Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting Suitable for dry / damp / wet locations 3 years warranty ( for 48V,54V only) ( except for 48V,54V ) SPECIFICATION LPF-60D-12 LPF-60D-15 LPF-60D-20 LPF-60D-24 LPF-60D-30 LPF-60D-36 LPF-60D-42 LPF-60D-48 LPF-60D-54 MODEL 12V DC VOLTAGE CONSTANT CURRENT REGION Note.4 7.2 ~12V OUTPUT 24V 30V 36V 42V 48V 54V 12 ~ 20V 14.4 ~ 24V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V 1.67A 1.43A 1.25A 1.12A RATED CURRENT 5A 4A 3A 2.5A RATED POWER 60W 60W 60W 60W 60W 60.12W 60.06W 60W 60.48W 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p RIPPLE & NOISE (max.) Note.2 150mVp-p VOLTAGE TOLERANCE Note.3 LOAD REGULATION SETUP, RISE TIME VOLTAGE RANGE O4.0% O0.5% O2.0% O4.0% O0.5% O1.5% O4.0% O0.5% O1.0% Note.7 1000ms, 80ms / 115VAC at full load 16ms/230VAC HOLD UP TIME (Typ.) Note.5 90 ~ 305VAC O4.0% O0.5% O0.5% O4.0% O0.5% O0.5% O4.0% O0.5% O0.5% O4.0% O 0.5% O 0.5% 1000ms, 80ms / 230VAC 16ms/115VAC at full load 127 ~ 431VDC POWER FACTOR (Typ.) PF>0.97/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve) EFFICIENCY (Typ.) 86% 88% 87% 0.8A / 115VAC 0.4A / 230VAC COLD START 75A/230VAC OVER CURRENT 90% 89% 0.32A / 277VAC 90% Note.4 OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.6 41 ~ 49V PACKING 54 ~ 63V 59 ~ 66V J O10J (RTH2) 90 Protection type : Shut down o/p voltage, re-power on to recover -40 ~ +70 J (Refer to "Derating Curve") 20 ~ 95% RH non-condensing J, 10 ~ 95% RH O0.03%/J (0 ~ 50J) -40 ~ +80 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.0-08(except for 48V, 54V), EN61347-1, EN61347-2-13 independent, IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN61000-3-2 Class C ( 60% load) ; EN61000-3-3 ISOLATION RESISTANCE 46 ~ 54V Protection type : Shut down and latch off o/p voltage, re-power on to recover EMC DIMENSION 90% Protection type : Constant current limiting, recovers automatically after fault condition is removed Hiccup mode, recovers automatically after fault condition is removed. 34 ~ 40V 15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 35V I/P-O/P:3.75KVAC EMC IMMUNITY MTBF 90% 95 ~ 108% SAFETY & WITHSTAND VOLTAGE EMC EMISSION 90% <0.75mA / 240VAC SHORT CIRCUIT NOTE O4.0% O0.5% O0.5% 47 ~ 63Hz LEAKAGE CURRENT OTHERS O4.0% O0.5% O0.5% FREQUENCY RANGE AC CURRENT (Typ.) INRUSH CURRENT (Typ.) PROTECTION 20V 9 ~ 15V 18 ~ 30V 2A LINE REGULATION INPUT 15V J U Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level(surge 2KV), criteria A 396.7K hrs min. MIL-HDBK-217F (25 ) 162.5*43*32mm (L*W*H) 0.45Kg; 32pcs/15.4Kg/0.93CUFT J J 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. File Name:LPF-60D-SPEC 2012-09-11 LPF-60D 60W Single Output Switching Power Supply Mechanical Specification Case No.LPF-60B series Unit:mm 162.5 3.5 r3. O 300 20 60 N N 13 SJTW 18AWG 2C 43 r 3.5 N 3.6 T case 6 3.5 O 300 20 AC/N(Blue) AC/L(Brown) UL2464 18AWG 2C(+V,-V) UL2464 22AWG 2C(DIM+,DIM-) 3.5 +V(Red) -V(Black) DIM+(Blue) DIM-(White) 32 T case: Max. Case Temperature. Block Diagram Fosc : 100KHz EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING PFC CIRCUIT +V -V DIM+ DIM- O.L.P. O.L.P. DETECTION CIRCUIT PWM & PFC CONTROL O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 230VAC Input only 70 50 LOAD (%) LOAD (%) 60 40 20 -40 -30 0 15 30 40 50 J AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 90 100 125 135 145 155 165 175 180 200 230 305 INPUT VOLTAGE (V) 60Hz File Name:LPF-60D-SPEC 2012-09-11 60W Single Output Switching Power Supply LPF-60D series Power Factor Characteristic PF Constant Current Mode 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 .9 9 .9 8 .9 7 .9 6 .9 5 .9 4 .9 3 .9 2 .9 1 0 .9 .8 9 .8 8 .8 7 .8 6 .8 5 .8 4 277VAC 230VAC 115VAC 50% 60% 70% 80% 90% 100% (60W) LOAD EFFICIENCY vs LOAD (48V Model) EFFICIENCY (%) LPF-60D series possess superior working efficiency that up to 90% can be reached in field applications. 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 277VAC 230VAC 115VAC 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. 100 Vo(%) Constant Current area 60 (max.) Hiccup Protection 50 95 Io (%) Typical LED power supply I-V curve File Name:LPF-60D-SPEC 2012-09-11 LPF-60D 60W Single Output Switching Power Supply series DIMMING OPERATION AC/N(Blue) AC/L(Brown) +V(Red) -V(Black) DIM+(Blue) DIM-(White) LPF-60D Built-in 3 in 1 dimming function, output constant current level can be adjusted through output cable by 1 ~ 10Vdc, 10V PWM signal or resistance between DIM+ and DIM-. Please DO NOT connect "DIM-" to "-V". Reference resistance value for output current adjustment (Typical) Resistance value [ 10K [ 20K 10% Output current 20% [ 30K 30% [ 40K 40% [ 50K [ 60K 50% 60% [ 70K 70% [ 80K 80% [ 90K [ 100K 90% 100% OPEN 95%~108% 1 ~ 10V dimming function for output current adjustment (Typical) Dimming value 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V OPEN Output current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% 10V PWM signal for output current adjustment (Typical): Frequency range :100Hz ~ 3KHz Duty value 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% OPEN Output current 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 95%~108% Using the built-in dimming function on LPF-60D can't turn the lighting fixture totally dark. Please refer to the connection method below to achieve 0% brightness of the lighting fixture connecting to the LED power supply unit. Dimming connection diagram for turning the lighting fixture ON/OFF : N L Switch Relay Adjuster 0~100K Ohms resistance 1~10V DC Voltage 10V PWM Signal Brown Blue AC/L LPF-60D AC/N DIM+ DIMV(-) V(+) Blue White Black Red LED Lighting Fixture Using a switch and relay can turn ON/OFF the lighting fixture. 1.Output constant current level can be adjusted through output cable by connecting a resistor or 1~10Vdc or 10V PWM signal between DIM+ and DIM-. 2.The LED lighting fixture can be turned ON/OFF by the switch. File Name:LPF-60D-SPEC 2012-09-11