48TECHNICAL 48 COOLING DATASHEET FILTER FAN PLUS FPI/FPO 018 | up to 97 m/h (124 x 124 mm) >>New air-flap outlet technology for high airflow >>Easy mounting >>Protection type test/Environmental rating by independent testing institutes (VDE and UL) >>Two systems for optimal airflow (FPI/FPO) >>Standard enclosure cut-out sizes (5 sizes) >>One filter mat Filter fans are used to provide an optimum climate in enclosures and cabinets with electrical/electronic components. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting airflow prevents formation of localised hot pockets in installations and protects electronic components from overheating. The Filter Fan Plus series uses a new air-flap outlet technology for the air outlet and thus reaches a high degree of airflow. A ratchet mechanism is used for mounting and provides high stability and tightness. Depending on the application there are two systems that are available - the FPI or FPO system. The FPI system is a standard installation with a filter fan in the lower part of the enclosure which ensures that fresh air is fed into the enclosure (airflow direction "In"). This system consists of a filter fan and exit filter. Whereas in the FPO system, the filter fan is located in the upper area of the enclosure to avoid heat buildups (airflow direction "Out"). The FPO system is composed of an intake filter and exit filter fan. The Filter Fan Plus series has been designed for indoor use. TECHNICAL DATA warm SYSTEM FPI Axial fan, ball bearing service life L10 at +40 C (+104 F): min. 37,000 h fan body aluminium, rotor metal Connection 2 stranded wires, 300 mm Casing, hood, flaps plastic according to UL94 V-0, light grey; UV light resistant according to UL746C (f1) Enclosure cut-out 124 x 124+1 mm Mounting frame 4 built-in ratchet braces for mounting (6 notches for wall thickness 1 -- 4 mm). Additional use of screws possible if needed1. Filter mat G3 acc. to DIN EN 779, average arrestance Aa 84 % Filter material synthetic fibre with progressive construction, temperature resistant to +100 C, self-extinguishing class F1, moisture resistant to 100 % RH, reusable Operating/Storage temperature -40 to +70 C (-40 to +158 F) Operating/Storage humidity max. 90 % RH (non-condensing) Protection type/Protection class IP54 / I (earthed) Environmental rating UL/NEMA UL TYPE 12 / NEMA 12 Approvals VDE, UL File No. E234324, EAC Note other voltages on request Exit Filter FPI 118 Air-flaps Filter Fan FPI 018 cold Filter mat 1 Drilling marks for screw mounting are indicated on mounting frame. AIRFLOW DIRECTION "IN": FILTER FAN FPI 018 Art. No. Operating voltage Air volume, free flow Air volume with exit filter 01871.0-30 01871.9-30 AC 230 V, 50/60 Hz 52 m/h 42 m/h AC 115 V, 50/60 Hz 62 m/h 51 m/h Current consumption (50/60 Hz) Power consumption Average noise level (DIN EN ISO 4871) Depth in enclosure Weight (approx.) Filter mat 120 mA 19 W 49 db (A) 66 mm 0.8 kg G3 230 mA 18 W 53 db (A) 66 mm 0.8 kg G3 AIRFLOW DIRECTION "IN": EXIT FILTER FPI 118 Art. No. Depth in enclosure Weight (approx.) Air outlet 11871.0-00 35 mm 0.3 kg air-flap outlet technology 19.03.2019 | Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. www.stego.de | www.stego.co.uk | www.stegonorden.se PRODUCT CATALOGUE - STEGO 4949 COOLING www.stego.de | www.stego.co.uk | www.stegonorden.se STEGO - PRODUCT CATALOGUE TECHNICAL DATASHEET warm SYSTEM FPO Filter Fan FPO 018 Air-flaps Intake Filter FPO 118 AIRFLOW DIRECTION "OUT": FILTER FAN FPO 018 Art. No. Operating voltage Air volume, free flow Air volume with intake filter 01881.0-00 AC 230 V, 50/60 Hz 97 m/h 47m/h 01881.9-00 AC 115 V, 50/60 Hz 117 m/h 58 m/h Current consumption (50/60 Hz) Power consumption Average noise level (DIN EN ISO 4871) Depth in enclosure Weight (approx.) Air outlet 120 mA 19 W 49 db (A) 79 mm 0.9 kg air-flaps 230 mA 18 W 52 db (A) 79 mm 0.9 kg air-flaps AIRFLOW DIRECTION "OUT": INTAKE FILTER FPO 118 Art. No. Depth in enclosure Weight (approx.) Filter mat 11881.0-30 22 mm 0.2 kg G3 acc. to DIN EN 779, average arrestance Aa 84 % FILTER MAT FM 086 Filter class 118 x 118 mm Average arrestance Aa 1 packing unit G3 acc. to DIN EN 779 Art. No. 08634.0-00 84 % 5 pieces TECHNICAL DRAWINGS 152 152 35 124 124 124 124 124 FPI 118 +1 0 ENCLOSURE CUT-OUT 25 22 25 124 124 124 FPI 018 79 152 124 124 25 25 22 22 124 66 25 25 25 25 124 124 2525 2525 152 79 79 3535 6666 152152 FPO 018 124 +1 0 ENCLOSURE CUT-OUT FPO 118 19.03.2019 | Specifications are subject to change without notice. Errors and omissions excepted. Suitability of this product for its intended use and any associated risks must be determined by the end customer/buyer in its final application. cold Filter mat