Auxiliary Function Modules
Prices Subject To Change Ñ We Always Ship At The Lowest Price In Effect ALLIED
c
169
For Complete Product Specifications
c
FAX-ON-DEMAND, Call 888-267-9188 for Instant Specs on Your FAX
c
www.crydom.com Ñ View and Download Specifications
AC Series SST
Soft-Start Modules
10-90 Amp; 120, 240 VAC; AC Output
c
UL Approved
c
FAX-ON-DEMAND Ñ Code: 202
Models SST120 and SST240 auxiliary function modules gradually
apply power to the load when energized by the control voltage. They
must be used with Crydom Series 1 random turn-on solid state relays.
Consult factory about use with 480 VAC loads. For a complete set
(control module and solid state relay) order 10SST120, 25SST120, etc.
Operating Temperature Range: Ð40¡C to 80¡C. Isolation Voltage
(Vrms): 4000.
Stock Mfr.Õs Line Voltage Load Current Control Voltage Surge Current EACH
No. Type Range (VAC) Range (Arms) Range (VDC) 1-Cycle (Apk)
682-0144 SST120* 90-140 * 3.5-10 * 29.49
682-4162 10SST120 90-140 0.04-10 3.5-10 120 58.96
682-4163 25SST120 90-140 0.04-25 3.5-10 250 55.00
682-0146 SST240* 180-280 * 3.5-10 * 29.92
682-4165 25SST240 180-280 0.04-25 3.5-10 250 57.63
682-4166 50SST240 180-280 0.04-40 3.5-10 625 62.45
682-4167 90SST240 180-280 0.04-90 3.5-10 1200 88.25
*Control module only, must be used with -10 (Series 1) DC input relay. All other models come with Series 1, -10 DC input
solid state relay.
AC Series CPV
Phase Control Modules
10-90 Amp; 120, 240 VAC ¥ AC Output
c
0-5 VDC Phase Control
c
FAX-ON-DEMAND Ñ Code: 203
Models CPV120 and CPV240 auxiliary function modules provide
control of the phased turn-on of a solid state relay, in response to the
application of a 0-5 VDC control signal. They must be used with
Crydom Series 1 random turn-on solid state relays. For a complete set
(control module and solid state relay) order 10CPV120, 25CPV120,
etc. Operating Temperature Range: Ð40¡C to 80¡C. Isolation Voltage
(Vrms): 4000.
Stock Mfr.Õs Line Voltage Load Current Control Voltage Surge Current EACH
No. Type Range (VAC) Range (Arms) Range (VDC) 1-Cycle (Apk)
682-4168 CPV120* 90-140 * 3.5-10 * 37.03
682-4169 10CPV120 90-140 0.04-10 3.5-10 120 57.34
682-4170 25CPV120 90-140 0.04-25 3.5-10 250 56.16
682-4171 40CPV120 90-140 0.04-40 3.5-10 625 58.52
682-4172 CPV240* 180-280 * 3.5-10 * 27.03
682-4174 25CPV240 180-280 0.04-25 3.5-10 250 58.30
682-4175 50CPV240 180-280 0.04-40 3.5-10 625 63.13
682-4177 90CPV240 180-280 0.04-90 3.5-10 1200 88.62
*Control module only, must be used with -10 (Series 1) DC input relay. All other models come with Series 1, -10 DC input
solid state relay.
AC Series RPC Solid State
Proportional Controller
15-40 Amp; 120, 240, 480 VAC; AC Output
c
Standard Package, Protective Cover Included
c
Uses Potentiometer for Economical Power Control
c
FAX-ON-DEMAND Ñ Code: 205
The RPC series proportional controllers provide a cost effective method
of controlling power in many applications such as heaters or
incandescent lamps. A customer provided potentiometer is all that is
required for control. Operating Temperature Range: Ð30¡C to 80¡C. Isolation Voltage (Vrms): 2500 (load to base plate
only). Warning: Control to load is not isolated, exercise care in handling this product to avoid the risk of electric shock.
Stock Mfr.Õs Line Voltage Load Current Off-State Surge Current EACH
No. Type Range (VAC) Range (Arms) Leakage (mA) 1-Cycle (Apk)
682-3051 RPC1215 90-130 0.07-15 10 150 50.26
682-3052 RPC1225 90-130 0.08-25 10 250 63.16
682-3053 RPC1240 90-130 0.09-40 10 625 88.79
682-3054 RPC2415 200-240 0.07-15 7 150 54.95
682-3055 RPC2425 200-240 0.08-25 7 250 68.08
682-3056 RPC2440 200-240 0.09-40 7 625 94.71
682-3057 RPC4815 400-480 0.07-15 3 150 67.98
682-3058 RPC4825 400-480 0.08-25 3 250 76.89
682-3059 RPC4840 400-480 0.09-40 3 625 103.52
AC Series PCV Analog Input
Power Controller
15-90 Amp; 120/240 VAC; AC Output
c
0-100% Control Range, Operates at 60 and 50 Hz
c
Internal Snubber, Industry Standard Package
c
UL, CSA Approved
c
FAX-ON-DEMAND Ñ Code: 204
The PCV Series proportional controllers are self contained power control
modules integrating a complete phase fired logic control system and a
solid state relay in the same standard package. Typical applications include heaters, vibratory feeders and tungsten lamps.
Operating Temperature Range: Ð30¡C to 80¡C. Isolation Voltage (Vrms): 2500.
Stock Mfr.Õs Line Voltage Load Current Control Voltage Surge Current EACH
No. Type Range (VAC) Range (Arms) Range (VDC) 1-Cycle (Apk)
682-3038 10PCV2415 100-240 0.15-15 2-10 150 66.95
682-3039 10PCV2425 100-240 0.15-25 2-10 250 78.62
682-4178 10PCV2450 100-240 0.15-50 2-10 625 95.82
682-4179 10PCV2475 100-240 0.15-75 2-10 1000 113.93
682-4180 10PCV2490 100-240 0.15-90 2-10 1200 126.58
AC Series LPCV Linear Proportional Load Controller
15-110 Amp; 120/240 VAC; AC Output
c
Back-to-Back SCR Output
c
Precise Proportional Load Controller
c
FAX-ON-DEMAND Ñ Code: 207
The LPCV linear proportional controllers control loads up to 110 amps. Changes in the input signal linearly vary the firing
angle of the thyristor load control device. Control circuitry and power switch are in a single package. Operating
Temperature Range: Ð30¡C to 80¡C. Isolation Voltage (Vrms): 2500.
Stock Mfr.Õs Line Voltage Load Current Control Surge Current EACH
No. Type Range (VAC) Range (Arms) Range 1-Cycle (Apk)
682-3010 5LPCV2425 20-300 0.10-25 0-5 VDC 250 246.25
682-3012 5LPCV2475 20-300 0.15-75 0-5 VDC 1000 290.31
682-3014 10LPCV2415 20-300 0.10-15 0-10 VDC 150 197.40
682-3016 10LPCV2440 20-300 0.10-40 0-10 VDC 625 266.51
682-3017 10LPCV2475 20-300 0.15-75 0-10 VDC 1000 307.76
682-3020 20LPCV2425 20-300 0.10-25 4-20 mA 250 232.26
682-3021 20LPCV2440 20-300 0.10-40 4-20 mA 625 282.56
AC Series PS
120 and 240 V Power Supplies
c
Provides Ideal Supply Voltage for Series LPCV Controllers
682-4183. PS-120. 120 V...................................................................................................................................... EACH 45.32
682-3025. PS-240. 240 V...................................................................................................................................... EACH 42.74
These Òon-operateÓ (pull-in) time-delay solid state relays are housed in a single industry standard package. AC output is
controlled by a DC input and has an externally adjustable time delays. Operating Temperature Range: Ð40¡C to 80¡C.
Isolation Voltage (Vrms): 4000.
Typical Turn-On Delay (For Various Timing Resistances)
0 (Short) 10 K½ Resistor 100 K½ Resistor 470 K½ Resistor 1.0 M½ Resistor
DSD Time 0.10 sec. 0.19 sec. 0.94 sec. 4.0 sec. 8.3 sec.
DLD Time 1.60 sec. 3.10 sec. 15.00 sec. 64.0 sec. 133.0 sec.
Stock Mfr.Õs Line Voltage Load Current Control Voltage Surge Current EACH
No. Type Range (VAC) Range (Arms) Range (VDC) 1-Cycle (Apk)
682-0094 DSD2410 48-280 0.04-10 3.5-15 120 38.83
682-0095 DSD2425 48-280 0.04-25 3.5-15 120 40.10
682-4145 DSD2450 48-280 0.04-50 3.5-15 120 39.20
682-4146 DLD2450 48-280 0.04-50 3.5-15 120 39.20
AC Series DSD/DLD Time Delay Modules
10-90 Amp; 120/240 VAC; AC Output
c
Externally Adjustable Time Delay
c
Industry Standard Package
c
UL Approved
c
FAX-ON-DEMAND Ñ Code: 201
Crydom
Company
4