TLRMH17T,TLSH17T,TLOH17T,TLYH17T TOSHIBA InGaAP LED TLRMH17T,TLSH17T,TLOH17T,TLYH17T Panel Circuit Indicator Unit: mm * 5 mm package * InGaAP technology * All plastic mold type * Transparent lens * Lineup: 3colors (red, orange, yellow) * High intensity light emission * Excellent low current light output * Applications: traffic signals, safety equipment, backlight * Straight lead type is also available TLRMH17TP, TLSH17TP, TLOH17TP, TLYH17TP Line-up Product Name Color TLRMH17T Red TLSH17T Red TLOH17T Orange TLYH17T Yellow Material InGaAlP JEITA TOSHIBA Weight: 0.31 g Maximum Ratings (Ta = 25C) Product Name JEDEC Forward Current IF (mA) Reverse Voltage VR (V) Power Dissipation PD (mW) Operating Temperature Topr (C) Storage Temperature Tstg (C) 50 4 120 -40~100 -40~120 TLRMH17T TLSH17T TLOH17T TLYH17T 1 2002-01-18 TLRMH17T,TLSH17T,TLOH17T,TLYH17T Electrical and Optical Characteristics (Ta = 25C) Product Name Typ. Emission Wavelength Luminous Intensity IV Forward Voltage VF Reverse Current IR d P IF Min Typ. IF Typ. Max IF Max VR TLRMH17T 626 (636) 13 20 850 3200 20 1.9 2.4 20 50 4 TLSH17T 613 (623) 13 20 1530 4500 20 2.0 2.4 20 50 4 TLOH17T 605 (612) 13 20 1530 5000 20 2.0 2.4 20 50 4 TLYH17T 587 (590) 13 20 1530 4800 20 2.0 2.4 20 50 4 mA A V Unit nm mA mcd mA V Precautions * Please be careful of the following: Soldering temperature: 260C max, soldering time: 3 s max (soldering portion of lead: below the lead stopper) * If the lead is formed, the lead should be formed up to 5 mm from the body of the device without forming stress to the resin. Soldering should be performed after lead forming. * This visible LED lamp also emits some IR light. If a photodetector is located near the LED lamp, please ensure that it will not be affected by this IR light. 2 2002-01-18 TLRMH17T,TLSH17T,TLOH17T,TLYH17T TLRMH17T IF - VF IV - IF 100 10000 (mcd) 30 Luminous intensity IV Forward current IF (mA) Ta = 25C 50 10 5 3 Ta = 25C 5000 3000 1000 500 300 100 50 1 1.6 1.7 1.8 1.9 2.0 Forward voltage 2.1 2.2 30 2.3 1 3 5 10 Forward current VF (V) IV - Tc 30 50 100 IF (mA) Relative luminous intensity - Wavelength 10 1.0 Ta = 25C Relative luminous intensity 5 3 1 0.5 0.3 0.1 -20 0 20 40 Case temperature Tc 60 0.8 0.6 0.4 0.2 0 580 80 600 620 Radiation pattern 10 0 10 30 40 50 50 60 60 70 70 80 80 0 0.2 700 100 120 (nm) (mA) 20 40 90 680 IF - Ta IF 20 660 80 Ta = 25C 30 640 Wavelength (C) Allowable forward current Relative luminous intensity IV IF = 20 mA 0.4 0.6 0.8 90 1.0 60 40 20 0 0 20 40 60 80 Ambient temperature Ta (C) 3 2002-01-18 TLRMH17T,TLSH17T,TLOH17T,TLYH17T TLSH17T IF - VF IV - IF 100 30000 (mcd) 30 Luminous intensity IV Forward current IF (mA) Ta = 25C 50 10 5 3 1 1.6 1.7 1.8 1.9 2.0 Forward voltage 2.1 2.2 Ta = 25C 10000 5000 3000 1000 500 300 100 2.3 1 3 VF (V) 5 10 Forward current IV - Tc 30 50 100 IF (mA) Relative luminous intensity - Wavelength 3 1.0 Relative luminous intensity Ta = 25C 1 0.5 0.3 0.1 -20 0 20 40 Case temperature Tc 60 0.8 0.6 0.4 0.2 0 560 80 580 600 Radiation pattern 10 0 10 30 40 50 50 60 60 70 70 80 80 0 0.2 680 100 120 (nm) (mA) 20 40 90 660 IF - Ta IF 20 640 80 Ta = 25C 30 620 Wavelength (C) Allowable forward current Relative luminous intensity IV IF = 20 mA 0.4 0.6 0.8 90 1.0 60 40 20 0 0 20 40 60 80 Ambient temperature Ta (C) 4 2002-01-18 TLRMH17T,TLSH17T,TLOH17T,TLYH17T TLOH17T IF - VF IV - IF 100 30000 (mcd) 30 Luminous intensity IV Forward current IF (mA) Ta = 25C 50 10 5 3 1 1.6 1.7 1.8 1.9 2.0 Forward voltage 2.1 2.2 Ta = 25C 10000 5000 3000 1000 500 300 100 2.3 1 VF (V) 5 10 Forward current IV - Tc 30 50 100 IF (mA) Relative luminous intensity - Wavelength 3 1.0 IF = 20 mA Relative luminous intensity Ta = 25C 1 0.5 0.3 0.1 -20 0 20 40 Case temperature Tc 60 0.8 0.6 0.4 0.2 0 540 80 560 580 Radiation pattern 10 0 10 30 40 50 50 60 60 70 70 80 80 0 0.2 660 100 120 (nm) (mA) 20 40 90 640 IF - Ta IF 20 620 80 Ta = 25C 30 600 Wavelength (C) Allowable forward current Relative luminous intensity IV 3 0.4 0.6 0.8 90 1.0 60 40 20 0 0 20 40 60 80 Ambient temperature Ta (C) 5 2002-01-18 TLRMH17T,TLSH17T,TLOH17T,TLYH17T TLYH17T IF - VF IV - IF 100 30000 (mcd) 30 Luminous intensity IV Forward current IF (mA) Ta = 25C 50 10 5 3 1 1.6 1.7 1.8 1.9 2.0 Forward voltage 2.1 2.2 Ta = 25C 10000 5000 3000 1000 500 300 100 2.3 1 3 VF (V) 5 10 Forward current IV - Tc 30 50 100 IF (mA) Relative luminous intensity - Wavelength 3 1.0 Relative luminous intensity Ta = 25C 1 0.5 0.3 0.1 -20 0 20 40 Case temperature Tc 60 0.8 0.6 0.4 0.2 0 540 80 560 580 Radiation pattern 10 0 10 30 40 50 50 60 60 70 70 80 80 0 0.2 660 100 120 (nm) (mA) 20 40 90 640 IF - Ta IF 20 620 80 Ta = 25C 30 600 Wavelength (C) Allowable forward current Relative luminous intensity IV IF = 20 mA 0.4 0.6 0.8 90 1.0 60 40 20 0 0 20 40 60 80 Ambient temperature Ta (C) 6 2002-01-18 TLRMH17T,TLSH17T,TLOH17T,TLYH17T RESTRICTIONS ON PRODUCT USE 000707EAC * TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc.. * The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. * Gallium arsenide (GaAs) is a substance used in the products described in this document. GaAs dust and fumes are toxic. Do not break, cut or pulverize the product, or use chemicals to dissolve them. When disposing of the products, follow the appropriate regulations. Do not dispose of the products with other industrial waste or with domestic garbage. * The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or others. * The information contained herein is subject to change without notice. 7 2002-01-18