POWER
LPT60 Series
60 Watts
Total Power: 60 - 80 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Triple
SPECIAL FEATURES
Universal input
3” x 5” footprint
Remote sense on main output
Built-in EMI lter
Low output ripple
Adjustable main output
Overvoltage protection
Overload protection
110 KHz switching frequency
LPX60 enclosure kit available
RoHS compliant
SAFETY
UL: 60950
E132002
cUL : 60950
LR53982C
NEMKO: EN 60950/EMKO-TUE
P95100123 (74-sec) 203
CB: Certicate and report
1518, 1519, 1520
CE: Mark (LVD)
Electrical Specications
Input
Input range 85 - 264 Vac
120 - 300 Vdc
Frequency 47 - 440 Hz
Inrush current <18 A peak @ 115 Vac;
<36 A peak @ 230 Vac, cold start @ 25 °C
Input current 1.5 A max. (RMS) @ 115 Vac
Efficiency 70% typical at full load (60% for LPT61)
EMI FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class
B conducted; VDE 0878 PT3 Class B conducted
Safety ground
leakage current
<0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power 60 W for convection (LPT61, 35 W);
80 W with 30CFW forced air (LPT61, 55 W)
Cross regulation ±2% on output 1; ±5% on outputs 2, 3
Adjustment range -5, +10% minimum
Hold-up time 20 ms @ 40 W load, 115 Vac nominal line
Overload protection Short circuit protection on all outputs. Case overload protected @ 110%
to 145% above peak rating
Overvoltage protection 5.7 to 6.7 Vdc on the main output
LPT41: 3.6 to 4.6 Vdc
Remote sense Compensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
Data Sheet
LPT60 Series Data Sheet
Ordering Information
Model
Number
Output
Voltage
Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air Peak Load1Regulation2Ripple
P/P (PARD)3
LPT61
+3.3 V
+5 V
+12 V
0.7 A
0 A
0 A
5 A
2.5 A
0.5 A
8.5 A
3.0 A
1.0 A
9.5 A
3.3 A
1 A
±2%
±2%
±5%
50 mV
50 mV
120 mV
LPT62
+5 V
+12 V
-12 V
0.7 A
0.3 A
0 A
7 A
3 A
0.7 A
8 A
3.5 A
1 A
10 A
6 A
1.5 A
±2%
±5%
±5%
50 mV
120 mV
120 mV
LPT63
+5 V
+15 V
-15 V
0.7 A
0.3 A
0 A
7 A
2.8 A
0.7 A
8 A
3.3 A
1 A
10 A
4 A
1.5 A
±2%
±5%
±5%
50 mV
150 mV
150 mV
LPT64
+5 V
+12 V
-5 V
0.7 A
0.3 A
0 A
7 A
3 A
0.7 A
8 A
3.5 A
1 A
10 A
6 A
1.5 A
±2%
±5%
±5%
50 mV
120 mV
50 mV
LPT65
+5 V
+24 V
+12 V
0.7 A
0.1 A
0 A
7 A
1.5 A
0.7 A
8 A
2.0 A
1 A
10 A
3 A
1.5 A
±2%
±7%
±5%
50 mV
240 mV
120 mV
Environmental Specications
Operating temperature 0 °C to 50 °C ambient derate each output at 2.5% per degree from 50 to 70 °C, -20 °C startup
Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity Operating; non-condensing 5% to 95%
Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500
Hz, operational
Storage temperature -40 °C to 85 °C
Temperature coefcient ±.04% per °C
MTBF demonstrated >550,000 hours at full load and 25 °C ambient conditions
Power Derating Curve
Output
Power
(Watts)
0°C
20W
40W
60W
80W
10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
0W
Natural
Convection
Cooling
40W
30W
30 CFM Forced Air Cooling
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
5.
This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated
as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
LPT60 Series Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
LPT60 Series-DS 22Mar2016
Mechanical Drawing
3.00"
(76.2)
2.55"
(64.8)
0.22"
(5.6)
0.22"
(5.6)
4.56"
(115.8) 5.00"
(127)
1.69"
(42.9)
0.12"
(3)
SK 1
SK 2
1
2
3
4
5
6
0.15" (4)
DIA (4 places)
GND
3
1
N
L
M1
M2
Remote Sense
Connector
_
+
SK201
Voltage
Adj. Pot
Pin Assignments
Connector LPT61 LPT62 LPT63 LPT64 LPT65
SK1-1 Line Line Line Line Line
SK1-3 Neutral Neutral Neutral Neutral Neutral
SK2-1 5V +12V +15V +12V +24V
SK2-2 3.3V +5V +5V +5V +5V
SK2-3 3.3V +5V +5V +5V +5V
SK2-4 Common Common Common Common Common
SK2-5 Common Common Common Common Common
SK2-6 +12V -12V -15V -5V +12V
SK201-1 +Sense +Sense +Sense +Sense +Sense
SK201-2 -Sense -Sense -Sense -Sense -Sense
Mating Connectors
AC Input
Molex 09-50-8031 (USA)
09-93-0300(UK)
PINS: 08-58-0111
DC Outputs
Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Remote Sense Molex 22-01-2025
PINS: 08-52-0113
Astec Connector Kit #70-841-006, includes all of the above
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02” (±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115
Vac input, 25 °C unless otherwise stated.
6. Warranty: 2 year
7. Weight: 0.75lbs/0.34kg